[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-41":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":665},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,41,50,2974,[13,34,46,58,70,82,100,112,124,136,151,163,175,187,199,211,226,241,251,266,281,293,305,317,332,344,356,371,386,400,412,424,436,450,464,476,490,505,517,532,546,560,572,584,596,604,616,628,640,650],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},936693,1,"单选题","在制定单位的应急预案时应明确单位的应急组织机构组成，下列不属于应急组织机构组成部分的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","协调保障组",true,{"key":24,"text":25,"correct":26},"B","灭火行动组",false,{"key":28,"text":29,"correct":26},"C","疏散引导组",{"key":31,"text":32,"correct":26},"D","通讯联络组","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},936694,"在应急预案演练中，负责编写演练总结报告以及演练文档归档与备案的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"总策划",{"key":24,"text":41,"correct":26},"宣传组",{"key":28,"text":43,"correct":22},"文案组",{"key":31,"text":45,"correct":26},"评估组",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},936695,"采用局部应用方式的开式系统，其喷头布置应能保证细水雾完全包络或覆盖保护对象或部位，喷头与保护对象的距离不宜小于（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":26},"0.2",{"key":24,"text":53,"correct":22},"0.5",{"key":28,"text":55,"correct":26},"0.7",{"key":31,"text":57,"correct":26},"1.5",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},936696,"采用七氟丙烷气体灭火系统的防护区的最低环境温度不应低于（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"-20℃",{"key":24,"text":65,"correct":22},"-10℃",{"key":28,"text":67,"correct":26},"0℃",{"key":31,"text":69,"correct":26},"20℃",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},936697,"采用全淹没应用方式的开式系统，其防护区数量不应大于3个。单个防护区的容积，对于泵组系统不宜超过（ ）m3，对于瓶组系统不宜超过（ ）m3。当超过单个防护区最大容积时，宜将该防护区分成多个分区进行保护。",[74,76,78,80],{"key":20,"text":75,"correct":26},"3600，800",{"key":24,"text":77,"correct":26},"1600，500",{"key":28,"text":79,"correct":22},"3000，260",{"key":31,"text":81,"correct":26},"3600，500",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},936698,2,"多选题","采用消防水泵串联分区供水时，宜采用消防水泵转输水箱串联供水方式，并符合下列规定（ ）。",[88,90,92,94,96],{"key":20,"text":89,"correct":22},"当采用消防水泵转输水箱串联时，转输水箱的有效储水容积不应小于60m3，转输水箱可作为高位消防水箱",{"key":24,"text":91,"correct":22},"串联转输水箱的溢流管宜连接到消防水池",{"key":28,"text":93,"correct":22},"当采用消防水泵直接串联时，应采取确保供水可靠性的措施，且消防水泵从低区到高区应能依次顺序启动",{"key":31,"text":95,"correct":22},"当采用消防水泵直接串联时，应校核系统供水压力，并应在串联消防水泵出水管上设置减压型倒流防止器",{"key":97,"text":98,"correct":26},"E","当采用消防水泵直接串联时，应校核系统供水压力，并应在并联消防水泵出水管上设置增压型倒流防止器","ABCD",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":31,"analysis":33},936699,"测试报警阀密封性，试验压力为额定工作压力为（ ）倍的静水压力，保证时间不小于（ ） min。",[104,106,108,110],{"key":20,"text":105,"correct":26},"1.0，5",{"key":24,"text":107,"correct":26},"1.5，3",{"key":28,"text":109,"correct":26},"2，10",{"key":31,"text":111,"correct":22},"2，5",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":28,"analysis":33},936700,"厂房、仓库消防水枪充实水柱应按（ ）计算。",[116,118,120,122],{"key":20,"text":117,"correct":26},"7m",{"key":24,"text":119,"correct":26},"10m",{"key":28,"text":121,"correct":22},"13m",{"key":31,"text":123,"correct":26},"17m",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":31,"analysis":33},936701,"城市消防远程监控系统竣工后，对工程进行检测时，选择的测试联网用户数量为（ ）个。",[128,130,132,134],{"key":20,"text":129,"correct":26},"10～15",{"key":24,"text":131,"correct":26},"5～15",{"key":28,"text":133,"correct":26},"1～10",{"key":31,"text":135,"correct":22},"5～10",{"id":137,"libraryId":5,"type":84,"typeLabel":85,"stem":138,"options":139,"answer":150,"analysis":33},936702,"对火灾报警系统中，控制类设备在消防控制室内的布置要求正确的有（ ）。",[140,142,144,146,148],{"key":20,"text":141,"correct":26},"在设备面盘前的操作距离，单列布置时不应小于1.2m，双列布置时不应小于1.5m",{"key":24,"text":143,"correct":26},"在值班人员经常工作的一面，设备面盘至墙的距离不应小于2m",{"key":28,"text":145,"correct":26},"设备面盘后的维修距离不宜小于1.2m",{"key":31,"text":147,"correct":22},"设备面盘的排列长度大于4m时，其两端应设置宽度不小于1m的通道",{"key":97,"text":149,"correct":22},"与建筑其他弱电系统合用的消防控制室内，消防设备应集中设置，并应与其它设备间有明显间隔","DE",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":33},936703,"对泡沫灭火系统组件进场检验过程中要求不正确的是（ ）。",[155,157,159,161],{"key":20,"text":156,"correct":26},"泡沫液进场应由监理工程师组织，现场取样留存",{"key":24,"text":158,"correct":22},"所有进场泡沫液均由监理工程师组织现场取样，送至具备相应资质的检测单位进行检测",{"key":28,"text":160,"correct":26},"检查现场取样按现行国家标准《泡沫灭火剂通用技术条件》的规定对发泡性能和灭火性能的检测报告",{"key":31,"text":162,"correct":26},"泡沫产生装置、泡沫比例混合器（装置）、泡沫液压力储罐、消防泵、泡沫消火栓、阀门、压力表、管道过滤器、金属软管等系统组件的规格、性能应符合行业现行产品标准和设计要求",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":28,"analysis":33},936704,"对气体灭火系统操作与控制要求错误的是（ ）。",[167,169,171,173],{"key":20,"text":168,"correct":26},"管网灭火系统应设自动控制、手动控制和机械应急操作三种启动方式。预制灭火系统应设自动控制和手动控制两种启动方式",{"key":24,"text":170,"correct":26},"气体灭火系统的操作与控制，应包括对开口封闭装置、通风机械和防火阀等设备的联动操作与控制",{"key":28,"text":172,"correct":22},"喷放灭火剂前，防护区内所有开口应能自行关闭",{"key":31,"text":174,"correct":26},"采用自动控制启动方式时，根据人员安全撤离防护区的需要，应有不大于30s的可控延迟喷射：对于平时无人工作的防护区，可设置为无延迟的喷射",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":31,"analysis":33},936705,"对气体灭火系统验收要求错误的说法是（ ）。",[179,181,183,185],{"key":20,"text":180,"correct":26},"检查每个防护区内和入口处的声光报警装置、气体喷放指示灯、入口处的安全标志",{"key":24,"text":182,"correct":26},"检查驱动气瓶和选择阀的机械应急手动操作处的永久标志",{"key":28,"text":184,"correct":26},"检查地下存储装置间的应急照明装置、火灾报警控制装置、机械排风装置",{"key":31,"text":186,"correct":22},"检查每个防护区配置的空气呼吸器",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":20,"analysis":33},936706,"对于采用传动管启动水喷雾灭火系统的做法中错误的是（ ）。",[191,193,195,197],{"key":20,"text":192,"correct":22},"雨淋报警阀组通过电动开启",{"key":24,"text":194,"correct":26},"系统利用闭式喷头探测火灾",{"key":28,"text":196,"correct":26},"雨淋报警阀组通过气动开启",{"key":31,"text":198,"correct":26},"雨淋报警阀组通过液动开启",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":24,"analysis":33},936707,"对于干粉灭火系统预制灭火装置的规定，正确的是。",[203,205,207,209],{"key":20,"text":204,"correct":26},"预制灭火装置灭火剂储存量不得大于200kg，管道长度不得大于15m，工作压力不得大于2.5MPa",{"key":24,"text":206,"correct":22},"一个防护区或保护对象宜用一套预制灭火装置保护",{"key":28,"text":208,"correct":26},"一个防护区或保护对象所用预制灭火装置最多不得超过2套，并应同时启动，其动作响应时间差不得大于2s",{"key":31,"text":210,"correct":26},"预制灭火装置应设机械应急操作启动方式",{"id":212,"libraryId":5,"type":84,"typeLabel":85,"stem":213,"options":214,"answer":225,"analysis":33},936708,"对于工程项目泡沫液用量较多的情况，需要将其送至具备相应资质的检测单位进行检测。对属于（ ）情况的泡沫液需要送检。",[215,217,219,221,223],{"key":20,"text":216,"correct":22},"6%型低倍数泡沫液设计用量大于或等于7.0t",{"key":24,"text":218,"correct":26},"6%型低倍数泡沫液设计用量大于或等于3.5t",{"key":28,"text":220,"correct":26},"3%蛋白型中倍数泡沫液最小储备量大于或等于2.5t",{"key":31,"text":222,"correct":22},"6%合成型中倍数泡沫液最小储备量大于或等于2.0t",{"key":97,"text":224,"correct":22},"高倍数泡沫液最小储备量大于或等于1.0t","ADE",{"id":227,"libraryId":5,"type":84,"typeLabel":85,"stem":228,"options":229,"answer":240,"analysis":33},936709,"对于流散B类火灾场所或面积不大于100m的流淌B类火灾场所，一般可能选择以下（ ）形式的泡沫灭火系统。",[230,232,234,236,238],{"key":20,"text":231,"correct":26},"全淹没系统",{"key":24,"text":233,"correct":22},"局部应用系统",{"key":28,"text":235,"correct":22},"移动式系统",{"key":31,"text":237,"correct":26},"固定式系统",{"key":97,"text":239,"correct":26},"半固定式系统","BC",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":28,"analysis":33},936710,"防火门电动开门器的手动控制按钮应设置在防火门内侧墙面上，距门不宜超过（ ）m，底边距地面高度宜为0.9m～1.3m。",[245,246,248,249],{"key":20,"text":57,"correct":26},{"key":24,"text":247,"correct":26},"1",{"key":28,"text":53,"correct":22},{"key":31,"text":250,"correct":26},"0.3",{"id":252,"libraryId":5,"type":84,"typeLabel":85,"stem":253,"options":254,"answer":265,"analysis":33},936711,"符合下列（ ）条件时，消防给水系统应分区供水。",[255,257,259,261,263],{"key":20,"text":256,"correct":22},"系统工作压力大于2.40MPa",{"key":24,"text":258,"correct":26},"消火栓栓口处动压大于1.0MPa",{"key":28,"text":260,"correct":22},"消火栓栓口处静压大于1.0MPa",{"key":31,"text":262,"correct":22},"自动水灭火系统报警阀处的工作压力大于1.60MPa或喷头处的工作压力大于1.20MPa",{"key":97,"text":264,"correct":26},"自动水灭火系统报警阀处的工作压力大于1.0MPa且喷头处的工作压力大于1.0MPa","ACD",{"id":267,"libraryId":5,"type":84,"typeLabel":85,"stem":268,"options":269,"answer":280,"analysis":33},936712,"干粉灭火系统按系统应具有以下几种系统启动方式。",[270,272,274,276,278],{"key":20,"text":271,"correct":22},"自动控制",{"key":24,"text":273,"correct":22},"手动控制",{"key":28,"text":275,"correct":22},"机械应急操作",{"key":31,"text":277,"correct":26},"联动启动",{"key":97,"text":279,"correct":26},"连锁启动","ABC",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":31,"analysis":33},936713,"高层民用建筑室内消火栓给水系统在运行时的最高压力不应超过下列（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":26},"1.2MPa",{"key":24,"text":288,"correct":26},"1.6MPa",{"key":28,"text":290,"correct":26},"2.0MPa",{"key":31,"text":292,"correct":22},"2.4MPa",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},936714,"根据《水喷雾规》GB50219，对水喷雾灭火系统应进行联动试验检查，系统响应时间、工作压力和流量应符合设计要求：当系统为手动控制时，应以手动方式进行至少（ ）检查系统的动作情况及信号反馈情况。",[297,299,301,303],{"key":20,"text":298,"correct":26},"3次",{"key":24,"text":300,"correct":22},"1次",{"key":28,"text":302,"correct":26},"4次",{"key":31,"text":304,"correct":26},"5次",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":24,"analysis":33},936715,"根据《消防给水及消火栓系统技术规范》（GB 50974-2014）的规定，下列关于室内消火栓系统日常维护管理的说法中，正确的是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":26},"每季度应该对消火栓进行一次严密性试验检查，发现有不正常的消火栓应及时更换",{"key":24,"text":312,"correct":22},"每季度应该对消火栓进行一次外观和漏水检查，发现有不正常的消火栓应及时更换",{"key":28,"text":314,"correct":26},"每季度应该对消火栓进行一次出水试验检查，发现有不正常的消火栓应及时更换",{"key":31,"text":316,"correct":26},"每季度应该对消火栓进行一次水压强度试验检查，发现有不正常的消火栓应及时更换",{"id":318,"libraryId":5,"type":84,"typeLabel":85,"stem":319,"options":320,"answer":331,"analysis":33},936716,"根据使用喷头的型式，自动喷水灭火系统可分为（ ）。",[321,323,325,327,329],{"key":20,"text":322,"correct":26},"湿式系统",{"key":24,"text":324,"correct":26},"干式系统",{"key":28,"text":326,"correct":22},"开式系统",{"key":31,"text":328,"correct":22},"闭式系统",{"key":97,"text":330,"correct":26},"预作用系统","CD",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":31,"analysis":33},936717,"关于报警阀及末端试水装置的说法中，错误的是（ ）。",[336,338,340,342],{"key":20,"text":337,"correct":26},"报警阀组控制的喷头只保护不超过防火分区面积的同层场所，可不设水流指示器",{"key":24,"text":339,"correct":26},"末端试水装置测试的内容，包括水流指示器、报警阀、压力开关、水力警铃",{"key":28,"text":341,"correct":26},"安装试水阀是为了在必要时连接末端试水装置",{"key":31,"text":343,"correct":22},"并联设置雨淋阀组的雨淋系统，其雨淋阀控制腔的入口应设置倒流防止器",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},936718,"关于发泡倍数的理解正确的是（ ）。",[348,350,352,354],{"key":20,"text":349,"correct":26},"泡沫体积与形成该泡沫的泡沫液体积的比值",{"key":24,"text":351,"correct":22},"泡沫体积与形成该泡沫的泡沫混合液体积的比值",{"key":28,"text":353,"correct":26},"泡沫液与泡沫混合液在泡沫中所占的体积百分比",{"key":31,"text":355,"correct":26},"泡沫液在泡沫混合液中所占的体积百分比",{"id":357,"libraryId":5,"type":84,"typeLabel":85,"stem":358,"options":359,"answer":370,"analysis":33},936719,"关于火灾警报和消防应急广播系统的联动控制设计，正确的要求是（ ）。",[360,362,364,366,368],{"key":20,"text":361,"correct":22},"火灾自动报警系统应设置火灾声光警报器，并应在确认火灾后启动建筑内的所有火灾声光警报器，消防应急广播系统应同时向全楼进行广播",{"key":24,"text":363,"correct":22},"同一建筑内设置多个火灾声警报器时，火灾自动报警系统应能同时启动和停止所有火灾声警报器工作",{"key":28,"text":365,"correct":22},"火灾声警报器设置带有语音提示功能时，应同时设置语音同步器",{"key":31,"text":367,"correct":26},"区域报警系统、集中报警系统和控制中心报警系统应设置消防应急广播",{"key":97,"text":369,"correct":22},"消防应急广播与普通广播或背景音乐广播合用时，应具有强制切入消防应急广播的功能","ABCE",{"id":372,"libraryId":5,"type":84,"typeLabel":85,"stem":373,"options":374,"answer":385,"analysis":33},936720,"关于火灾自动报警系统供电及接地要求正确的是（ ）。",[375,377,379,381,383],{"key":20,"text":376,"correct":22},"火灾自动报警系统应设置交流电源和蓄电池备用电源",{"key":24,"text":378,"correct":22},"备用电源可采用火灾报警控制器和消防联动控制器自带的蓄电池电源或消防设备应急电源",{"key":28,"text":380,"correct":26},"消防用电设备可以与其他用电设备合用，其配电设备应设有明显标志。其配电线路和控制回路宜按防火分区划分",{"key":31,"text":382,"correct":22},"消防控制室内的电气和电子设备的金属外壳、机柜、机架和金属管、槽等，应采用等电位连接",{"key":97,"text":384,"correct":22},"消防控制室接地板与建筑接地体之间，应采用线芯截面面积不小于25mm2的铜芯绝缘导线连接","ABDE",{"id":387,"libraryId":5,"type":84,"typeLabel":85,"stem":388,"options":389,"answer":99,"analysis":33},936721,"关于室内消火栓的设置，下列说法中不正确的是（ ）。",[390,392,394,396,398],{"key":20,"text":391,"correct":22},"设置室内消火栓的建筑，其中设备层可以不设置消火栓",{"key":24,"text":393,"correct":22},"建筑高度不大于54m的住宅，当设置消火栓时，可采用干式消防竖管",{"key":28,"text":395,"correct":22},"高层建筑、厂房、库房和室内净空高度超过8m的民用建筑等场所，消火栓栓口动压不应小于0.25MPa",{"key":31,"text":397,"correct":22},"消火栓应采用同一型号规格。应采用DN65室内消火栓；应配置公称直径65有内衬里的消防水带，长度不宜超过30m。",{"key":97,"text":399,"correct":26},"高层汽车库和地下汽车库、半地下汽车库室内消火栓的间距不应大于30m",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":31,"analysis":33},936722,"关于室外消火栓进出口口径检查，错误的设置是（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":26},"室外地上式消火栓进水口口径为DN100，出水口口径为一个DN100、两个DN65",{"key":24,"text":407,"correct":26},"室外地上式消火栓进水口口径为DN150，出水口口径为一个DN150、两个DN65",{"key":28,"text":409,"correct":26},"室外地下式消火栓进水口口径为DN100，出水口口径为一个DN100、一个DN65",{"key":31,"text":411,"correct":22},"室外地下式消火栓进水口口径为DN150，出水口口径为一个DN150、一个DN65",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":20,"analysis":33},936723,"关于水流指示器的设置不正确的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"湿式系统必须设置水流指示器",{"key":24,"text":419,"correct":26},"设置水流指示器时应按防火分区及楼层设置",{"key":28,"text":421,"correct":26},"仓库内顶板下喷头与货架内喷头应分别设置水流指示器",{"key":31,"text":423,"correct":26},"当水流指示器入口前设置控制阀时，应采用信号阀",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},936724,"关于自动喷水灭火系统相关阀门的开闭状态描述中正确的是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":22},"湿式系统的湿式报警阀平时常闭，火灾自动开启",{"key":24,"text":431,"correct":26},"湿式系统的信号蝶阀平时常闭，火灾开启",{"key":28,"text":433,"correct":26},"干式系统的干式报警阀平时常开，火灾自动开启",{"key":31,"text":435,"correct":26},"雨淋系统的雨淋报警阀平时常开，火灾自动开启",{"id":437,"libraryId":5,"type":84,"typeLabel":85,"stem":438,"options":439,"answer":370,"analysis":33},936725,"管径为DN150mm的消防给水管道架空安装时，应按规定设置防晃支架，下列相关要求中，正确的有（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"配水管宜在中点设一个防晃支架",{"key":24,"text":443,"correct":22},"配水干管及配水管，配水支管的长度超过15m，每15m长度内应至少设1个防晃支架",{"key":28,"text":445,"correct":22},"管道拐弯、三通及四通位置处应设1个防晃支架",{"key":31,"text":447,"correct":26},"架空管道每段管道设置的防晃支架不应少于2个",{"key":97,"text":449,"correct":22},"立管应在其始端和终端设防晃支架或采用管卡固定",{"id":451,"libraryId":5,"type":84,"typeLabel":85,"stem":452,"options":453,"answer":370,"analysis":33},936726,"过滤器是细水雾灭火系统的关键部件之一，安装过滤器可以防止水中杂质损坏设备和堵塞喷头，由于喷头一般均自带过滤网，因此，首先要在供水水源和供水管网上设置过滤器进行初级过滤。过滤器应符合下列规定。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"在储水箱进水口处应设置过滤器",{"key":24,"text":457,"correct":22},"出水口或控制阀前应设置过滤器",{"key":28,"text":459,"correct":22},"过滤器的网孔孔径不应大于喷头最小喷孔孔径的80%",{"key":31,"text":461,"correct":26},"在细水雾灭火系统中常用的过滤器是盘式过滤器",{"key":97,"text":463,"correct":22},"过滤器的材质应为不锈钢、铜合金，或其他耐腐蚀性能不低于不锈钢、铜合金的材料",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":33},936727,"火灾报警控制器调试使控制器与探测器之间的连线断路和短路，控制器应在（ ）s内发出故障信号。",[468,470,472,474],{"key":20,"text":469,"correct":26},"50",{"key":24,"text":471,"correct":22},"100",{"key":28,"text":473,"correct":26},"150",{"key":31,"text":475,"correct":26},"200",{"id":477,"libraryId":5,"type":84,"typeLabel":85,"stem":478,"options":479,"answer":385,"analysis":33},936728,"火灾自动报警系统包括（ ）。",[480,482,484,486,488],{"key":20,"text":481,"correct":22},"火灾探测报警系统",{"key":24,"text":483,"correct":22},"消防联动控制系统",{"key":28,"text":485,"correct":26},"疏散诱导系统",{"key":31,"text":487,"correct":22},"可燃气体探测报警系统",{"key":97,"text":489,"correct":22},"电气火灾监控系统",{"id":491,"libraryId":5,"type":84,"typeLabel":85,"stem":492,"options":493,"answer":504,"analysis":33},936729,"火灾自动报警系统的控制器类设备在消防控制室内的正确布置是（ ）。",[494,496,498,500,502],{"key":20,"text":495,"correct":22},"设备面盘前的操作距离，单列布置时不应小于1.5m，双列布置时不应小于2m",{"key":24,"text":497,"correct":22},"在值班人员经常工作的一面，设备面盘至墙的距离不应小于3m",{"key":28,"text":499,"correct":26},"设备面盘后的维修距离不宜小于2m",{"key":31,"text":501,"correct":26},"设备面盘的排列长度大于3m时，其两端应设置宽度不小于1m的通道",{"key":97,"text":503,"correct":22},"与建筑其他弱电系统合用的消防控制室内，消防设备应集中设置，并应与其他设备间有明显间隔","ABE",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":33},936730,"火灾自动报警系统对火灾声光警报器进行调试，逐一将火灾声光警报器与火灾报警控制器相连，接通电源。操作火灾报警控制器使火灾声光警报器启动，火灾光警报器的光信号在100～500lx环境光线下，（ ）m处应清晰可见。",[509,511,513,515],{"key":20,"text":510,"correct":26},"15",{"key":24,"text":512,"correct":22},"25",{"key":28,"text":514,"correct":26},"35",{"key":31,"text":516,"correct":26},"45",{"id":518,"libraryId":5,"type":84,"typeLabel":85,"stem":519,"options":520,"answer":531,"analysis":33},936731,"火灾自动报警系统竣工后，建设单位对该系统进行系统检测，下列做法错误的有（ ）。",[521,523,525,527,529],{"key":20,"text":522,"correct":22},"抽验了10台火灾报警控制器中的5台",{"key":24,"text":524,"correct":22},"抽验了30只火灾探测器中的10只",{"key":28,"text":526,"correct":26},"在消防控制室内操作室内消火栓泵启停3次",{"key":31,"text":528,"correct":22},"压力开关、电动阀、电磁阀检查了安装数量的一半",{"key":97,"text":530,"correct":26},"对所有广播分区进行选区广播，对共用扬声器进行强行切换","ABD",{"id":533,"libraryId":5,"type":84,"typeLabel":85,"stem":534,"options":535,"answer":385,"analysis":33},936732,"火灾自动报警系统竣工后，建设单位应负责组织施工、设计、监理等单位进行检测，检测不合格不得投入使用，系统检测时，施工单位应提供的资料包括（ ）。",[536,538,540,542,544],{"key":20,"text":537,"correct":22},"竣工检测申请报告、设计变更通知书、竣工图",{"key":24,"text":539,"correct":22},"工程质量事故处理报告，施工现场质量管理检查记录",{"key":28,"text":541,"correct":26},"施工许可证",{"key":31,"text":543,"correct":22},"火灾自动报警系统施工过程质量管理检查记录",{"key":97,"text":545,"correct":22},"火灾自动报警系统内各设备的检查报告、合格证及相关材料",{"id":547,"libraryId":5,"type":84,"typeLabel":85,"stem":548,"options":549,"answer":99,"analysis":33},936733,"基于水喷雾灭火系统的灭火原理，下列场所中，水喷雾灭火系统适用于扑救的是（ ）。",[550,552,554,556,558],{"key":20,"text":551,"correct":22},"固体物质火灾",{"key":24,"text":553,"correct":22},"燃油锅炉",{"key":28,"text":555,"correct":22},"电缆隧道",{"key":31,"text":557,"correct":22},"油浸式电力变压器",{"key":97,"text":559,"correct":26},"碳化钙库房",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":28,"analysis":33},936734,"建筑高度120米的住宅的消防水箱最小有效容积（ ）和最不利点处的静水压力为（ ）",[564,566,568,570],{"key":20,"text":565,"correct":26},"18m3，0.07MPa",{"key":24,"text":567,"correct":26},"18m3，0.10MPa",{"key":28,"text":569,"correct":22},"36m3，0.07MPa",{"key":31,"text":571,"correct":26},"36m3，0.10MPa",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":20,"analysis":33},936735,"建筑高度为48m的16层住宅建筑，一梯三户，每户建筑面积120m2，每个单元设置一座防烟楼梯间，一部消防电梯和一部客梯。该建筑每个单元需设置的室内消火栓总数量不应少于（ ）个。",[576,578,580,582],{"key":20,"text":577,"correct":22},"16",{"key":24,"text":579,"correct":26},"8",{"key":28,"text":581,"correct":26},"32",{"key":31,"text":583,"correct":26},"48",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":24,"analysis":33},936736,"建筑内疏散照明的地面最低水平照度应符合相关规定，其中人员密集场所疏散照明的地面最低水平照度为（ ）。",[588,590,592,594],{"key":20,"text":589,"correct":26},"1.0lx",{"key":24,"text":591,"correct":22},"3.0lx",{"key":28,"text":593,"correct":26},"5.0lx",{"key":31,"text":595,"correct":26},"10.0lx",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":31,"analysis":33},936737,"建筑内疏散照明的地面最低水平照度应符合相关规定，其中手术部的避难间疏散照明的地面最低水平照度为（ ）。",[600,601,602,603],{"key":20,"text":589,"correct":26},{"key":24,"text":591,"correct":26},{"key":28,"text":593,"correct":26},{"key":31,"text":595,"correct":22},{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":24,"analysis":33},936738,"开式系统的设计响应时间不应大于（ ）。采用全淹没应用方式的开式系统，当采用瓶组系统且在同一防护区内使用多组瓶组时，各瓶组应能同时启动，其动作响应时差不应大于（ ）。",[608,610,612,614],{"key":20,"text":609,"correct":26},"15s，2s",{"key":24,"text":611,"correct":22},"30s，2s",{"key":28,"text":613,"correct":26},"30s，5s",{"key":31,"text":615,"correct":26},"15s，5s",{"id":617,"libraryId":5,"type":15,"typeLabel":16,"stem":618,"options":619,"answer":28,"analysis":33},936739,"控制器类设备的安装符合要求的是（ ）。",[620,622,624,626],{"key":20,"text":621,"correct":26},"采用壁挂方式安装时，其主显示屏高度宜为1.3~1.5m",{"key":24,"text":623,"correct":26},"采用壁挂方式安装时，正面操作距离不应小于1.8m",{"key":28,"text":625,"correct":22},"采用壁挂方式安装时，其靠近门轴的侧面距墙不应小于0.5m",{"key":31,"text":627,"correct":26},"落地安装时，其底边宜高出地（楼）面0.5~0.8m",{"id":629,"libraryId":5,"type":15,"typeLabel":16,"stem":630,"options":631,"answer":28,"analysis":33},936740,"某2层地上商店建筑，每层建筑面积为6000m2，所设置的自动喷水灭火系统应至少设置（ ）个水流指示器。",[632,634,636,638],{"key":20,"text":633,"correct":26},"2",{"key":24,"text":635,"correct":26},"3",{"key":28,"text":637,"correct":22},"4",{"key":31,"text":639,"correct":26},"5",{"id":641,"libraryId":5,"type":15,"typeLabel":16,"stem":642,"options":643,"answer":31,"analysis":33},936741,"某5层数据计算机房，层高5m，每层有1200m2的大空间计算机用房，设置IG541组合分配气体灭火系统保护。该建筑的气体灭火系统防护区最少应划分为（ ）个。",[644,645,647,648],{"key":20,"text":639,"correct":26},{"key":24,"text":646,"correct":26},"6",{"key":28,"text":579,"correct":26},{"key":31,"text":649,"correct":22},"10",{"id":651,"libraryId":5,"type":84,"typeLabel":85,"stem":652,"options":653,"answer":664,"analysis":33},936742,"某办公楼每层为一个防火分区，设有火灾自动报警系统、室内消火栓系统和防烟排烟系统等消防设施。当正压送风机控制柜处于自动状态时，检测风机的启动情况，下列操作中，能够启动正压送风机的有（ ）。",[654,656,658,660,662],{"key":20,"text":655,"correct":22},"使消防联动控制器处于自动状态，使用发烟器分别对十层的楼梯间前室及内走道的各一只感烟探测器进行模拟火灾报警测试，两只探测器先后发出火灾报警信号",{"key":24,"text":657,"correct":26},"使消防联动控制器处于手动状态，使用发烟器对一楼大厅的一只感烟探测器进行模拟火灾报警测试，探测器发出火灾报警信号，再按下一只手动火灾报警按钮发出火灾报警信号",{"key":28,"text":659,"correct":22},"在消防控制室内的消防联动控制器上手动按下正压送风机的启动按钮",{"key":31,"text":661,"correct":26},"使消防联动控制器处于手动状态，使用发烟器分别对八层的两间办公室内的各一只感烟探测器进行模拟火灾报警测试，两只探测器先后发出火灾报警信号",{"key":97,"text":663,"correct":22},"使消防联动控制器处于自动状态，手动开启设在六层防烟楼梯间的送风口","ACE",[666,669,672,675,678,681],{"id":15,"name":667,"category":7,"favorite":668},"领导干部任职前廉政法规知识测试题",92,{"id":670,"name":671,"category":7,"favorite":15},595,"建筑结构与设备",{"id":673,"name":674,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":676,"name":677,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":679,"name":680,"category":7,"favorite":8},534,"BIM工程师",{"id":682,"name":680,"category":7,"favorite":8},535]