[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-36":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,36,50,2974,[13,34,46,56,68,78,90,99,111,123,135,144,156,168,180,192,204,216,234,249,264,279,294,306,318,330,345,357,365,377,387,399,408,423,435,450,462,470,479,491,506,518,530,541,551,563,575,587,597,609],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},936442,1,"单选题","消防联动控制器设置在消防控制室内时，设备面盘后的维修距离不宜小于（ ）m。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1",true,{"key":24,"text":25,"correct":26},"B","1．5",false,{"key":28,"text":29,"correct":26},"C","2",{"key":31,"text":32,"correct":26},"D","3","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},936443,"对探测器施加浓度为探测器报警设定值的可燃气体标准样气，探测器的报警确认灯应在（ ）s内点亮并保持。",[38,40,42,44],{"key":20,"text":39,"correct":26},"60",{"key":24,"text":41,"correct":26},"50",{"key":28,"text":43,"correct":22},"30",{"key":31,"text":45,"correct":26},"40",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},936444,"火灾报警系统各类管路暗敷时，应敷设在不燃结构内，且保护层厚度不应小于（ ）mm。",[50,52,54,55],{"key":20,"text":51,"correct":26},"10",{"key":24,"text":53,"correct":26},"20",{"key":28,"text":41,"correct":26},{"key":31,"text":43,"correct":22},{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":24,"analysis":33},936445,"某检测机构对施工完毕的火灾自动报警系统进行检测，下列关于检测的结果中，不符合相关规定的是（ ）。",[60,62,64,66],{"key":20,"text":61,"correct":26},"使消防电话分机与总机之间的连接线断路，消防电话主机在90s后发出故障信号",{"key":24,"text":63,"correct":22},"使扬声器与消防应急广播控制设备之问的广播信息传输线路断路，消防应急广播控制设备在110s后发出故障信号",{"key":28,"text":65,"correct":26},"用于分隔防火分区的防火卷帘在接收到防火分区内的火灾报警信号后，控制防火卷帘下降至楼板面",{"key":31,"text":67,"correct":26},"手动操作防火卷帘控制器的按钮，防火卷帘能够启、闭",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":20,"analysis":33},936446,"某消防检测机构对建筑内施工结束的火灾自动报警系统进行验收，建筑内共设区域显示器20台，根据《火灾自动报警系统设计规范》（GB 50116—2019）的要求，应至少抽取（ ）台进行功能检验。",[72,73,75,76],{"key":20,"text":53,"correct":22},{"key":24,"text":74,"correct":26},"9",{"key":28,"text":51,"correct":26},{"key":31,"text":77,"correct":26},"4",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":28,"analysis":33},936447,"引入火灾报警控制器的电缆或导线，应留有不小于（ ）mm的余量。",[82,84,86,88],{"key":20,"text":83,"correct":26},"100",{"key":24,"text":85,"correct":26},"150",{"key":28,"text":87,"correct":22},"200",{"key":31,"text":89,"correct":26},"250",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":20,"analysis":33},936448,"某商城火灾自动报警系统安装完毕后，施工人员对系统主要部件进行调试。其中，区域显示器应在（ ）s内正确接收和显示火灾报警控制器发出的火灾报警信号。",[94,95,97,98],{"key":20,"text":32,"correct":22},{"key":24,"text":96,"correct":26},"5",{"key":28,"text":51,"correct":26},{"key":31,"text":53,"correct":26},{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":24,"analysis":33},936449,"下列关于引入火灾自动报警控制器的电缆和导线安装要求的说法中，错误的是（ ）。",[103,105,107,109],{"key":20,"text":104,"correct":26},"控制器内端子板的每个接线端接线不能超过2根",{"key":24,"text":106,"correct":22},"控制器的主电源严禁与消防电源直接相连",{"key":28,"text":108,"correct":26},"接到端子板的电缆芯线和导线，应留有不小于200mm的余量",{"key":31,"text":110,"correct":26},"导线穿管、线槽后，应将管口、槽口封堵",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":31,"analysis":33},936450,"当敷设在顶棚下方的线型差温火灾探测器至顶棚距离宜为（ ）m,相邻探测器之间的水平距离不宜大于（ ）m。",[115,117,119,121],{"key":20,"text":116,"correct":26},"0.5，1",{"key":24,"text":118,"correct":26},"0.1，2",{"key":28,"text":120,"correct":26},"1，5",{"key":31,"text":122,"correct":22},"0.1，5",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":28,"analysis":33},936451,"消防技术检测服务机构对某建筑内火灾探测器的安装质量进行检查，结果如下，其中不符合规范规定的是（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":26},"安装在宽度为2．5m的内走道顶棚上的点型感烟探测器的间距为12m",{"key":24,"text":130,"correct":26},"安装在顶棚上的点型感烟探测器距多孔送风顶棚孔口的水平距离为1．2m",{"key":28,"text":132,"correct":22},"安装在办公室的点型感烟火灾探测器距梁边的距离为0．4m",{"key":31,"text":134,"correct":26},"安装在办公室的点型感烟火灾探测器至空调送风口边的水平距离为1.6m",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":20,"analysis":33},936452,"对可燃气体报警控制器进行调试，使控制器与探测器之间的连线断路，控制器应在（ ）s内发出故障信号。",[139,140,142,143],{"key":20,"text":83,"correct":22},{"key":24,"text":141,"correct":26},"120",{"key":28,"text":39,"correct":26},{"key":31,"text":43,"correct":26},{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":28,"analysis":33},936453,"消防联动控制器应具有发出联动控制信号强制（ ）停于首层或电梯转换层的功能。",[148,150,152,154],{"key":20,"text":149,"correct":26},"消防电梯",{"key":24,"text":151,"correct":26},"靠近着火防火分区的一侧的消防电梯",{"key":28,"text":153,"correct":22},"所有电梯",{"key":31,"text":155,"correct":26},"靠近着火防火分区的一侧的电梯",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":31,"analysis":33},936454,"下列关于火灾自动报警系统中组件安装的说法，错误的是（ ）。",[160,162,164,166],{"key":20,"text":161,"correct":26},"点型探测器倾斜安装时，倾斜角度不应大于45°",{"key":24,"text":163,"correct":26},"同一报警区域内的模块应集中安装在金属箱内",{"key":28,"text":165,"correct":26},"手动火灾报警按钮的连接导线应留有不小于150mm的余量",{"key":31,"text":167,"correct":22},"光警报器与疏散指示标志安装在同一面墙上时，距离不应小于1．5m",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":20,"analysis":33},936455,"在对火灾自动报警系统工程质量进行验收时,下列情形中,可判定为 A 类不合格的是（ ）。",[172,174,176,178],{"key":20,"text":173,"correct":22},"感烟火灾探测器规格型号与设计不符",{"key":24,"text":175,"correct":26},"检测资料不符合相关要",{"key":28,"text":177,"correct":26},"施工现场质量管理检查记录不完整",{"key":31,"text":179,"correct":26},"火灾自动报警系统施工过程质量管理检查记录不完整",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":31,"analysis":33},936456,"对火灾报警系统中,控制类设备在消防控制室内的布置要求正确的有（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":26},"在设备面盘前的操作距离,单列布置时不应小于 1.2m,双列布置时不应小于 1.5m",{"key":24,"text":187,"correct":26},"在值班人员经常工作的一面,设备面盘至墙的距离不应小于 2m",{"key":28,"text":189,"correct":26},"设备面盘后的维修距离不宜小于 1.2m",{"key":31,"text":191,"correct":22},"设备面盘的排列长度大于 4m 时,其两端应设置宽度不小于 1m 的通道",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":24,"analysis":33},936457,"外浮顶油罐宜采用（ ）火灾探测器，每只探测器能保护（ ）个油罐",[196,198,200,202],{"key":20,"text":197,"correct":26},"火焰，1",{"key":24,"text":199,"correct":22},"线型光纤，1",{"key":28,"text":201,"correct":26},"火焰，2",{"key":31,"text":203,"correct":26},"线型光纤，2",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":33},936459,"由于报警总线开路使火灾报警控制器发出故障报警，故障指示灯亮，则排除该故障的方法是（ ）。",[208,210,212,214],{"key":20,"text":209,"correct":26},"重新压接总线，使之与底座有良好接触",{"key":24,"text":211,"correct":22},"查出有故障的总线位置，予以更换",{"key":28,"text":213,"correct":26},"维修或更换接口板",{"key":31,"text":215,"correct":26},"更换探测器",{"id":217,"libraryId":5,"type":218,"typeLabel":219,"stem":220,"options":221,"answer":233,"analysis":33},936460,2,"多选题","火灾自动报警系统调试结束后应编写调试报告，施工单位、设备制造企业应向建设单位提交（ ）。",[222,224,226,228,230],{"key":20,"text":223,"correct":22},"系统竣工图",{"key":24,"text":225,"correct":22},"材料设备及配件进场检查记录",{"key":28,"text":227,"correct":22},"安装质量检查记录",{"key":31,"text":229,"correct":26},"系统设施维护记录表",{"key":231,"text":232,"correct":26},"E","施工现场质量管理检查记录","ABC",{"id":235,"libraryId":5,"type":218,"typeLabel":219,"stem":236,"options":237,"answer":248,"analysis":33},936461,"某建筑进入火灾自动报警系统调试阶段，根据现行《火灾自动报警系统施工及验收标准》，触发某报警区域内的一只感烟火灾探测器和一只手报按钮，下列系统中可以动作的是（ ）",[238,240,242,244,246],{"key":20,"text":239,"correct":26},"用于防火分隔中的雨淋阀组",{"key":24,"text":241,"correct":26},"消火栓系统中的消防水泵",{"key":28,"text":243,"correct":22},"全楼疏散通道的应急照明和疏散指示系统",{"key":31,"text":245,"correct":22},"该报警区域内所有常开防火门",{"key":231,"text":247,"correct":26},"全楼所有的声光警报器同时启动，且与应急广播交替循环","CD",{"id":250,"libraryId":5,"type":218,"typeLabel":219,"stem":251,"options":252,"answer":263,"analysis":33},936462,"在对某民用建筑内设置的机械加压送风系统进行检测时，应检测系统的联动控制功能，根据《火灾自动报警系统设计规范》GB 50116—2013，下列能够联动开启加压送风口的有（ ）。",[253,255,257,259,261],{"key":20,"text":254,"correct":22},"加压送风口所在防火分区内的两只独立的火灾探测器的动作信号",{"key":24,"text":256,"correct":26},"加压送风口所在防火分区内一只火灾探测器与相邻防火分区的一只手动火灾报警按钮的动作信号",{"key":28,"text":258,"correct":26},"加压送风口所在防火分区内的两只独立的手动火灾报警按钮的动作信号",{"key":31,"text":260,"correct":22},"加压送风口所在防火分区内一只火灾探测器与一只手动火灾报警按钮的动作信号",{"key":231,"text":262,"correct":26},"加压送风口所在防烟分区内一只火灾探测器与相邻防烟分区的一只手动火灾报警按钮的动作信号","AD",{"id":265,"libraryId":5,"type":218,"typeLabel":219,"stem":266,"options":267,"answer":278,"analysis":33},936463,"根据《火灾自动报警系统施工及验收规范》GB 50166—2007的要求，下列关于火灾自动报警系统周期性维护保养的说法中，正确的是（ ）。",[268,270,272,274,276],{"key":20,"text":269,"correct":22},"每年检查消防电梯的联动控制功能",{"key":24,"text":271,"correct":26},"每年检查风机控制柜手动控制功能",{"key":28,"text":273,"correct":26},"每季度检查火灾警报器的报警功能",{"key":31,"text":275,"correct":26},"每月应检查火灾报警控制器的功能",{"key":231,"text":277,"correct":22},"每年对消防应急广播功能试验","AE",{"id":280,"libraryId":5,"type":218,"typeLabel":219,"stem":281,"options":282,"answer":293,"analysis":33},936464,"对某公共建筑火灾自动报警系统的消防联动控制器进行功能检测，下列检测结果中，符合现行国家消防技术标准的要求的是（ ）。",[283,285,287,289,291],{"key":20,"text":284,"correct":22},"切断消防联动控制器与各模块之间的连线， 消防联动控制器在90s秒时发出故障信号",{"key":24,"text":286,"correct":26},"切断消防联动控制器与备用电源之间的连线，消防联动控制器在115s时发出故障信号",{"key":28,"text":288,"correct":26},"使总线隔离器保护范围内的一个模块短路，消防联动控制器显示该模块故障",{"key":31,"text":290,"correct":22},"使55个模块同时处于动作状态，消防联动控制器能正常接收信号并发出联动信号",{"key":231,"text":292,"correct":22},"对消防联动控制器发出的故障报警声响，可以消音","ADE",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},936465,"城市消防远程监控系统中用户信息传输装置应每（ ）进行自检功能检查。",[298,300,302,304],{"key":20,"text":299,"correct":22},"日",{"key":24,"text":301,"correct":26},"周",{"key":28,"text":303,"correct":26},"月",{"key":31,"text":305,"correct":26},"年",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":28,"analysis":33},936466,"2018 年某城市的消防远程监控系统正式建成,在其投入使用前需要对系统及系统组件进行调试。系统在各项功能调试后进行试运行,试运行时间不少于（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":26},"15 天",{"key":24,"text":313,"correct":26},"20 天",{"key":28,"text":315,"correct":22},"30 天",{"key":31,"text":317,"correct":26},"40 天",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":31,"analysis":33},936467,"下列关于城市消防远程监控系统中用户服务系统软件的使用与检查要求的叙述中，错误的是（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":26},"与监控中心的通信测试为1次／日",{"key":24,"text":325,"correct":26},"与监控中心的时钟检查为1次／日",{"key":28,"text":327,"correct":26},"每月进行用户服务系统软件运行日志整理",{"key":31,"text":329,"correct":22},"与监控中心的通信测试为2次／日",{"id":331,"libraryId":5,"type":218,"typeLabel":219,"stem":332,"options":333,"answer":344,"analysis":33},936468,"城市消防远程监控施工安装过程中出现的下列现象中，正确的是（ ）。",[334,336,338,340,342],{"key":20,"text":335,"correct":22},"将远程监控总线金属管直接穿到安装盒中，并在盒外侧加锁母",{"key":24,"text":337,"correct":26},"将不小心弄断的远程监控总线重新剥线，烫锡后铰接，用胶布缠好后再穿管",{"key":28,"text":339,"correct":22},"用户信息传输装置相连接的不同电压等级、不同电流类别的线路，布置在不同管路内",{"key":31,"text":341,"correct":26},"接线过程中，如只剩下一种颜色的导线，将其中一根导线分别打个结，以区分电源极性",{"key":231,"text":343,"correct":22},"施工人员在看起来很干净、干燥的工作环境施工后，还特意将穿管与接线盒的接口处做了封闭处理","ACE",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},936469,"下列关于城市消防远程监控系统组件安装的做法中，正确的是（ ）。",[349,351,353,355],{"key":20,"text":350,"correct":26},"用户信息传输装置在墙上安装时，底边距地面高度为1．2m",{"key":24,"text":352,"correct":22},"引入用户信息传输装置的导线的每个接线端，接线不超过2根",{"key":28,"text":354,"correct":26},"引入用户信息传输装置的导线留有不小于150mm的余量",{"key":31,"text":356,"correct":26},"用户信息传输装置落地安装时，底边高出地面0．5m",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},936470,"在对用户传输装置进行调试时，用户信息传输装置应能在（ ）s内将手动报警信息传送至监控中心。",[361,362,363,364],{"key":20,"text":96,"correct":26},{"key":24,"text":51,"correct":22},{"key":28,"text":53,"correct":26},{"key":31,"text":83,"correct":26},{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":31,"analysis":33},936471,"城市消防远程监控系统竣工后，由建设单位负责组织相关单位进行工程检测，下列选择的测试联网用户数量符合规定的是（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":26},"2个联网用户",{"key":24,"text":372,"correct":26},"3个联网用户",{"key":28,"text":374,"correct":26},"4个联网用户",{"key":31,"text":376,"correct":22},"6个联网用户",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":24,"analysis":33},936472,"对用户信息传输装置的主电源和备用电源进行切换试验，应每（ ）不少于1次。",[381,382,384,386],{"key":20,"text":303,"correct":26},{"key":24,"text":383,"correct":22},"半年",{"key":28,"text":385,"correct":26},"季度",{"key":31,"text":305,"correct":26},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":28,"analysis":33},936473,"城市消防远程监控系统投入运行满1年后，每半年应检查的内容是（ ）。",[391,393,395,397],{"key":20,"text":392,"correct":26},"系统运行及维护记录等文件是否完备",{"key":24,"text":394,"correct":26},"系统网络安全性",{"key":28,"text":396,"correct":22},"录音文件的保存情况",{"key":31,"text":398,"correct":26},"监控系统日志",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":31,"analysis":33},936474,"在对用户传输装置进行调试时，用户信息传输装置在传输建筑消防设施运行状态信息期间，应发出指示信息传输的光信号或信息提示，该光信号应在信息传输成功后至少保持（ ）s。",[403,404,405,406],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":26},{"key":28,"text":87,"correct":26},{"key":31,"text":407,"correct":22},"300",{"id":409,"libraryId":5,"type":218,"typeLabel":219,"stem":410,"options":411,"answer":422,"analysis":33},936475,"监控中心日常应做好技术文件的记录，并及时归档，妥善保管，下列属于监控中心日常文件的是（ ）。",[412,414,416,418,420],{"key":20,"text":413,"correct":22},"值班日志",{"key":24,"text":415,"correct":22},"接处警登记表",{"key":28,"text":417,"correct":26},"系统产品的检验报告、合格证及相关材料",{"key":31,"text":419,"correct":22},"交接班登记表",{"key":231,"text":421,"correct":22},"设备运行、巡检及故障记录","ABDE",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":24,"analysis":33},936476,"自动喷水灭火系统工程的施工，应按照批准的工程设计文件和施工技术标准进行施工。施工中要注意施工过程质量控制，下列说法不符合规范要求的是（ ）。",[427,429,431,433],{"key":20,"text":428,"correct":26},"各工序应按施工技术标准进行质量控制，每道工序完成后，应进行检查，检查合格后方可进行下道工序",{"key":24,"text":430,"correct":22},"相关各专业工种之间应进行交接检验，并经技术工程师签字后方可进行下道工序",{"key":28,"text":432,"correct":26},"施完工后，施工单位应向建设单位提供质量控制资料和各类施工过程质量检查记录",{"key":31,"text":434,"correct":26},"施工过程质量检查组织应由监理工程师组织施工单位人员组成",{"id":436,"libraryId":5,"type":218,"typeLabel":219,"stem":437,"options":438,"answer":449,"analysis":33},936477,"下列关于城市消防远程监控系统用户信息传输装置调试要求的说法中，错误的有（ ）。",[439,441,443,445,447],{"key":20,"text":440,"correct":26},"使用手动报警，传输装置应能在10s内将手动报警信息传输至监控中心",{"key":24,"text":442,"correct":22},"模拟火灾报警，传输装置应能完整接收火灾报警信息，并在15s内将信息传输至监控中心",{"key":28,"text":444,"correct":26},"模拟与监控中心间的报警传输网络故障，传输装置应在100s内发出故障信号",{"key":31,"text":446,"correct":22},"模拟建筑消防设施的各种状态，传输装置应能完整接收状态信息，并在15s内将信息传输至监控中心",{"key":231,"text":448,"correct":22},"使传输装置与备用电源之间的连线断路和短路，传输装置应在120s内发出故障信号","BDE",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},936478,"城市消防远程监控系统中，（ ）是城市消防远程监控系统的核心，是对远程监控系统中的各类信息进行集中管理的节点。",[454,456,458,460],{"key":20,"text":455,"correct":22},"监控中心",{"key":24,"text":457,"correct":26},"火警信息终端",{"key":28,"text":459,"correct":26},"用户信息传输装置",{"key":31,"text":461,"correct":26},"报警传输网络",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":33},936479,"从接线盒、线槽等处引到用户信息传输装置的线路，当采用金属软管保护时，其长度不应大于（ ）m。",[466,467,468,469],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":26},{"key":28,"text":29,"correct":22},{"key":31,"text":32,"correct":26},{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":28,"analysis":33},936480,"城市消防远程监控系统能够对联网用户的火灾报警信息、建筑消防设施运行状态信息进行接收、处理和查询，向城市消防通信指挥中心或其他接处警中心发送经确认的火灾报警信息，城市消防远程监控系统的构成部分不包括（ ）。",[474,475,476,478],{"key":20,"text":459,"correct":26},{"key":24,"text":461,"correct":26},{"key":28,"text":477,"correct":22},"建筑消防设施",{"key":31,"text":457,"correct":26},{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":20,"analysis":33},936481,"城市消防远程监控系统正式投入使用前，对系统及系统组件进行调试。系统在各项功能调试后进行试运行，试运行时间不少于（ ）月。",[483,485,487,489],{"key":20,"text":484,"correct":22},"1个",{"key":24,"text":486,"correct":26},"2个",{"key":28,"text":488,"correct":26},"3个",{"key":31,"text":490,"correct":26},"4个",{"id":492,"libraryId":5,"type":218,"typeLabel":219,"stem":493,"options":494,"answer":505,"analysis":33},936482,"下列关于城市消防远程监控系统通信服务器软件定期检查与测试的说法中，正确的有（ ）。",[495,497,499,501,503],{"key":20,"text":496,"correct":22},"每月检查系统数据库使用情况，必要时对硬盘进行扩充",{"key":24,"text":498,"correct":22},"与监控中心报警受理系统的通信测试1次／日",{"key":28,"text":500,"correct":26},"通信服务器软件如因故障维修等原因需要暂时停用的，如停用时间不长可暂不通知各联网用户单位消防安全负责人",{"key":31,"text":502,"correct":26},"与报警受理系统、火警信息终端、用户信息传输装置等其他终端之间时钟检查2次／日",{"key":231,"text":504,"correct":22},"每月进行通信服务器软件运行日志整理","ABE",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":28,"analysis":33},936483,"消防站的布局一般应以接到出动指令后5min内可以到达辖区边缘为原则确定，设在近郊区的普通站不应大于（ ）km2，设在城市的消防，一级站不宜大于（ ）km2。",[510,512,514,516],{"key":20,"text":511,"correct":26},"7，5",{"key":24,"text":513,"correct":26},"5，7",{"key":28,"text":515,"correct":22},"15，7",{"key":31,"text":517,"correct":26},"7，15",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":20,"analysis":33},936484,"区域火灾风险评估是分析区域安全状况、降低区域火灾风险的有效手段，其中一级指标一般包括火灾危险源、区域基础信息、消防力量和（ ）等。",[522,524,526,528],{"key":20,"text":523,"correct":22},"社会面防控能力",{"key":24,"text":525,"correct":26},"消防管理",{"key":28,"text":527,"correct":26},"消防宣传教育",{"key":31,"text":529,"correct":26},"灾害抵御能力",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":24,"analysis":33},936485,"对某区域进行火灾风险评估，建立评估指标体系时，不属于一级指标的是（ ）。",[534,536,538,539],{"key":20,"text":535,"correct":26},"火灾危险源",{"key":24,"text":537,"correct":22},"城市公共消防基础设施",{"key":28,"text":523,"correct":26},{"key":31,"text":540,"correct":26},"消防力量",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":24,"analysis":33},936486,"下列不属于区域火灾风险评估中的一级指标的内容的是（ ）。",[545,546,547,549],{"key":20,"text":535,"correct":26},{"key":24,"text":525,"correct":22},{"key":28,"text":548,"correct":26},"区域基础信息",{"key":31,"text":550,"correct":26},"消防救援力量",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":31,"analysis":33},936487,"年度内火灾死亡人数与常住人口的比值是（ ）。",[555,557,559,561],{"key":20,"text":556,"correct":26},"万人火灾发生率",{"key":24,"text":558,"correct":26},"万人火灾死亡率",{"key":28,"text":560,"correct":26},"十万人火灾发生率",{"key":31,"text":562,"correct":22},"十万人火灾死亡率",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":28,"analysis":33},936488,"造成8人死亡，10人重伤，直接财产损失800万元的火灾，属于（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":26},"特别重大火灾",{"key":24,"text":570,"correct":26},"重大火灾",{"key":28,"text":572,"correct":22},"较大火灾",{"key":31,"text":574,"correct":26},"一般火灾",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":24,"analysis":33},936489,"根据公安部2007年下发的《关于调整火灾等级标准的通知》中的火灾事故等级分级标准，将火灾风险等级分为极高风险、高风险和中风险、低风险。火灾事故导致2人死亡、40人重伤、900万元的直接经济损失，则该次事故火灾风险等级应划分为（ ）。",[579,581,583,585],{"key":20,"text":580,"correct":26},"极高风险",{"key":24,"text":582,"correct":22},"高风险",{"key":28,"text":584,"correct":26},"中风险",{"key":31,"text":586,"correct":26},"低风险",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":24,"analysis":33},936490,"在火灾防控水平计算时，为反映火灾防控水平与人口数量的关系需用到的系数是（ ）。",[591,593,594,595],{"key":20,"text":592,"correct":26},"千人火灾死亡率",{"key":24,"text":556,"correct":22},{"key":28,"text":562,"correct":26},{"key":31,"text":596,"correct":26},"亿元GDP火灾损失率",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":24,"analysis":33},936491,"下列不属于火灾危险源评估单元分类的是（ ）。",[601,603,605,607],{"key":20,"text":602,"correct":26},"客观因素",{"key":24,"text":604,"correct":22},"环境因素",{"key":28,"text":606,"correct":26},"人为因素",{"key":31,"text":608,"correct":26},"气象因素",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":24,"analysis":33},936492,"开展消防评估的原则不包括（ ）。",[613,615,617,619],{"key":20,"text":614,"correct":26},"系统性原则",{"key":24,"text":616,"correct":22},"科学性原则",{"key":28,"text":618,"correct":26},"实用性原则",{"key":31,"text":620,"correct":26},"可操作性原则",[622,625,628,631,634,637],{"id":15,"name":623,"category":7,"favorite":624},"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":15},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]