[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-35":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":646},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,35,50,2974,[13,34,46,64,79,91,103,115,127,138,150,159,171,183,195,205,217,229,241,252,263,275,287,299,311,326,341,355,370,382,392,404,419,433,448,462,477,491,503,517,529,544,556,568,583,591,599,609,624,634],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},936392,1,"单选题","某建筑高度为105m的民用建筑，主楼为办公楼，附设裙房，裙房的使用功能为商场。消防技术服务机构对该建筑的应急疏散照明设施进行检查，检查结果如下，其中不符合现行国家工程建设消防技术标准的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","主楼防烟楼梯间的地面最低水平照度为3lx",true,{"key":24,"text":25,"correct":26},"B","主楼疏散走道的地面最低水平照度为1．5lx",false,{"key":28,"text":29,"correct":26},"C","商场营业厅的地面最低水平照度为3lx",{"key":31,"text":32,"correct":26},"D","主楼避难层的地面最低水平照度为3．5lx","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},936393,"下列有关消防应急照明和疏散指示系统供配电的说法中,不正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"多个防火分区共用一个应急照明配电箱的主电源只应取自应急电源干线",{"key":24,"text":41,"correct":26},"大于 2000m2的防火分区应单独设置应急照明配电箱或应急照明分配电装置",{"key":28,"text":43,"correct":26},"小于 2000 ㎡的防火分区可采用专用应急照明回路",{"key":31,"text":45,"correct":26},"应急照明回路沿电缆管井垂直敷设时,公共建筑应急照明配电箱供电范围不宜超过 8 层",{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":63,"analysis":33},936394,2,"多选题","下列关于消防应急灯具电线电缆选择与线路敷设的说法中，正确的是（ ）。",[52,54,56,58,60],{"key":20,"text":53,"correct":26},"系统的配电支线应采用多股铜芯导线，控制线路应采用铜芯导线",{"key":24,"text":55,"correct":22},"不同电压等级的线缆不应穿入同一根保护管内，当合用同一线槽时，线槽内应有金属隔板分隔",{"key":28,"text":57,"correct":22},"灯具的供电线路和控制线路敷设在潮湿场所时，均应选择耐腐蚀的橡胶电缆",{"key":31,"text":59,"correct":22},"应急照明分配电装置的输出线路为B1级电线电缆时，应穿金属管保护",{"key":61,"text":62,"correct":22},"E","集中控制型系统的控制线路选择燃烧性能为A级的电线电缆时，可明敷","BCDE",{"id":65,"libraryId":5,"type":48,"typeLabel":49,"stem":66,"options":67,"answer":78,"analysis":33},936395,"火灾自动报警系统进行布线时，当管路超过一定长度，应在便于接线处装设接线盒。下列部位应设置接线盒的是（ ）。",[68,70,72,74,76],{"key":20,"text":69,"correct":22},"管子长度32m，无弯曲",{"key":24,"text":71,"correct":26},"管子长度6m，有2个弯曲时",{"key":28,"text":73,"correct":22},"管子长度21m，有1个弯曲时",{"key":31,"text":75,"correct":26},"管子长度15m，有1个弯曲",{"key":61,"text":77,"correct":22},"管子长度9m，有3个弯曲","ACE",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":28,"analysis":33},936396,"某消防技术服务机构对施工完毕的火灾自动报警系统进行检查，检查结果符合规范要求的是（ ）。",[83,85,87,89],{"key":20,"text":84,"correct":26},"点型感烟火灾探测器距离墙壁的水平距离为0．3m",{"key":24,"text":86,"correct":26},"安装在顶棚上的点型感烟火灾探测器距离空调送风口的水平距离为0．5m",{"key":28,"text":88,"correct":22},"在宽度小于3m的内走道顶棚上安装探测器时、宜居中安装，点型感温火灾探测器的安装间距不应超过10m，点型感烟火灾探测器的安装间距不应超过15m，探测器至端墙的距离不应大于安装间距的一半。",{"key":31,"text":90,"correct":26},"每个报警区域的模块集中设置在配电箱内",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":31,"analysis":33},936397,"下列关于手动报警按钮安装的说法中，错误的是（ ）。",[95,97,99,101],{"key":20,"text":96,"correct":26},"手动火灾报警按钮应安装牢固，不应倾斜",{"key":24,"text":98,"correct":26},"手动火灾报警按钮的连接导线应留有不小于150mm的余量，且在其端部应有明显标志",{"key":28,"text":100,"correct":26},"手动火灾报警按钮应安装在明显和便于操作的部位",{"key":31,"text":102,"correct":22},"手动火灾报警按钮安装在墙上时，其底边距地（楼）面高度宜为1．5～1．8m",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":31,"analysis":33},936398,"检查各类管路明敷时，应采用单独的卡具吊装或支撑物固定，吊杆直径不应小（ ）mm",[107,109,111,113],{"key":20,"text":108,"correct":26},"2",{"key":24,"text":110,"correct":26},"5",{"key":28,"text":112,"correct":26},"8",{"key":31,"text":114,"correct":22},"6",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":31,"analysis":33},936399,"消防技术服务机构对某建筑内管路采样吸气式感烟火灾探测器进行功能检查。下列检查结果中，不符合现行国家消防技术标准要求的有（ ）。",[119,121,123,125],{"key":20,"text":120,"correct":26},"高灵敏度吸气式感烟火灾探测器当设置为高灵敏度时，可安装在天棚高度大于16m的场所，并应保证至少有两个采样孔低于16m",{"key":24,"text":122,"correct":26},"非高灵敏度的吸气式感烟火灾探测器不宜安装在天棚高度大于16m的场所",{"key":28,"text":124,"correct":26},"采样管应牢固安装在过梁、空间支架等建筑结构上",{"key":31,"text":126,"correct":22},"当采样管道采用毛细管布置方式时，毛细管长度不宜超过5m",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":24,"analysis":33},936400,"消防联动控制系统控制与显示类设备的引入线缆端子板的每个接线端接线不应超过（ ）根。",[131,133,134,136],{"key":20,"text":132,"correct":26},"1",{"key":24,"text":108,"correct":22},{"key":28,"text":135,"correct":26},"3",{"key":31,"text":137,"correct":26},"4",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},936401,"点型感烟火灾探测器，探测器至空调送风口最近边的水平距离不应小于（ ）m,至多孔送风顶棚孔口的水平距离不应小于（ ）m。",[142,144,146,148],{"key":20,"text":143,"correct":22},"1.5,0.5",{"key":24,"text":145,"correct":26},"1.2,0.5",{"key":28,"text":147,"correct":26},"1.5,1",{"key":31,"text":149,"correct":26},"1.2,1",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},936402,"某公共建筑设有8台火灾报警控制器，在竣工验收时，应抽取（ ）台进行功能检验。",[154,155,156,158],{"key":20,"text":110,"correct":26},{"key":24,"text":112,"correct":22},{"key":28,"text":157,"correct":26},"10",{"key":31,"text":114,"correct":26},{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":28,"analysis":33},936403,"根据火灾自动报警系统工程质量检测判定标准，下列可判定为B类不合格的是（ ）。",[163,165,167,169],{"key":20,"text":164,"correct":26},"某手动报警按钮无法发出报警信号",{"key":24,"text":166,"correct":26},"某探测器无法发出报警信号",{"key":28,"text":168,"correct":22},"火灾自动报警系统施工过程质量管理检查记录不全",{"key":31,"text":170,"correct":26},"某消防电话分机无法与消防控制室通话",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":31,"analysis":33},936404,"某建筑采用火灾自动报警系统保护，设有点型感烟火灾探测器1500只，点型感温火灾探测器400只，则关于该建筑火灾探测器备用量的说法，正确的是（ ）。",[175,177,179,181],{"key":20,"text":176,"correct":26},"感烟探测器备用量不少于150只，感温探测器备用量不少于40只",{"key":24,"text":178,"correct":26},"探测器备用量不少于190只",{"key":28,"text":180,"correct":26},"感烟探测器备用量不少于50只，感温探测器备用量不少于50只",{"key":31,"text":182,"correct":22},"感烟探测器备用量不少于15只，感温探测器备用量不少于4只",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":31,"analysis":33},936405,"某消防设施检测机构的人员对建筑物内安装的火灾自动报警系统进行检查，下列检查结果中，符合现行国家消防技术标准要求的有（ ）。",[187,189,191,193],{"key":20,"text":188,"correct":26},"可燃气体报警控制器在墙上安装时，底边距地面高度为1．2m",{"key":24,"text":190,"correct":26},"手动火灾报警按钮安装在墙上时，底边距地面高度为1．6m",{"key":28,"text":192,"correct":26},"手动火灾报警按钮的连接导线余量为100mm",{"key":31,"text":194,"correct":22},"消防电话在墙面上安装时，底边距地面高度宜为1．4m",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":31,"analysis":33},936406,"消防电源监控系统由消防电源监控器、电压传感器、电流传感器等设备组成，对消防设备电源进行（ ）小时监测。",[199,201,202,203],{"key":20,"text":200,"correct":26},"12",{"key":24,"text":157,"correct":26},{"key":28,"text":112,"correct":26},{"key":31,"text":204,"correct":22},"24",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":33},936407,"对某建筑内安装的火灾自动报警系统进行检查时，发现部分模块的连接导线余量不够，根据现行国家消防技术标准，关于模块的连接导线余量应留有不小于（ ）mm的余量。",[209,211,213,215],{"key":20,"text":210,"correct":26},"100",{"key":24,"text":212,"correct":22},"150",{"key":28,"text":214,"correct":26},"200",{"key":31,"text":216,"correct":26},"250",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":31,"analysis":33},936408,"物业公司对某建筑内安装的火灾自动报警系统进行检测维护，根据《火灾自动报警系统施工及验收规范》GB 50116—2007，应每（ ）试验消防应急广播系统进行一次功能检查。",[221,223,225,227],{"key":20,"text":222,"correct":26},"日",{"key":24,"text":224,"correct":26},"月",{"key":28,"text":226,"correct":26},"季度",{"key":31,"text":228,"correct":22},"年",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},936409,"某建筑物内设有火灾自动报警系统，下列关于火灾探测器的安装质量检查结果中，不符合安装要求的是（ ）。",[233,235,237,239],{"key":20,"text":234,"correct":26},"安装在顶棚上的点型感烟探测器距多孔送风顶棚孔口的水平距离为1 m",{"key":24,"text":236,"correct":22},"安装在宽度为2 m的内走道顶棚上的点型感温探测器的间距为12 m",{"key":28,"text":238,"correct":26},"在净高度为12 m的中庭安装的一对红外光束感烟探测器距地面的垂直距离为11 m，且在这一高度上没有任何遮挡物",{"key":31,"text":240,"correct":26},"会议室内感烟探测器的报警确认灯朝向会议室的门口",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":31,"analysis":33},936410,"火灾光警报装置,采用壁挂方式安装时，底边距地面高度应大于（ ）m。",[245,247,248,250],{"key":20,"text":246,"correct":26},"1.8",{"key":24,"text":108,"correct":26},{"key":28,"text":249,"correct":26},"1.6",{"key":31,"text":251,"correct":22},"2.2",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":28,"analysis":33},936411,"对火灾报警控制器进行调试，使控制器与探测器之间的连线断路和短路，控制器应在（ ）s内发出火灾报警信号。",[256,258,260,261],{"key":20,"text":257,"correct":26},"60",{"key":24,"text":259,"correct":26},"30",{"key":28,"text":210,"correct":22},{"key":31,"text":262,"correct":26},"120",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":20,"analysis":33},936412,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，消防控制室内单列布置时不应小于（ ）m,，双列布置时 不应小于（ ）m。",[267,269,271,273],{"key":20,"text":268,"correct":22},"1.5, 2",{"key":24,"text":270,"correct":26},"1, 1.5",{"key":28,"text":272,"correct":26},"1.2,1.5",{"key":31,"text":274,"correct":26},"1，3",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":28,"analysis":33},936413,"某消防技术服务机构对某场所安装的线型光束感烟火灾探测器进行了检测，下列测试结果符合要求的是（ ）。",[279,281,283,285],{"key":20,"text":280,"correct":26},"用减光率为0．9dB的减光片遮挡光路，探测器发出报警信号",{"key":24,"text":282,"correct":26},"用减光率为10dB的减光片遮挡光路，探测器发出故障信号",{"key":28,"text":284,"correct":22},"用减光率为5dB的减光片遮挡光路，探测器发出报警信号",{"key":31,"text":286,"correct":26},"用减光率为11．5dB的减光片长时间遮挡光路，探测器未发出任何信号",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":28,"analysis":33},936414,"管路采样式吸气感烟火灾探测器在调试时，需在采样管的（ ）采样孔加入试验烟，采用秒表测量探测器的报警响应时间。",[291,293,295,297],{"key":20,"text":292,"correct":26},"首端",{"key":24,"text":294,"correct":26},"中端",{"key":28,"text":296,"correct":22},"末端",{"key":31,"text":298,"correct":26},"任一",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":20,"analysis":33},936415,"火灾自动报警系统控制器规格型号与设计不符，定为（ ）不合格。",[303,305,307,309],{"key":20,"text":304,"correct":22},"A类",{"key":24,"text":306,"correct":26},"B类",{"key":28,"text":308,"correct":26},"C类",{"key":31,"text":310,"correct":26},"D类",{"id":312,"libraryId":5,"type":48,"typeLabel":49,"stem":313,"options":314,"answer":325,"analysis":33},936416,"火灾自动报警系统布线中的线槽敷设时，设置吊点或支点说法正确的是（ ）。",[315,317,319,321,323],{"key":20,"text":316,"correct":22},"线槽始端、终端及接头处",{"key":24,"text":318,"correct":22},"吊杆直径不应小于6mm:",{"key":28,"text":320,"correct":26},"距接线盒0．5m处",{"key":31,"text":322,"correct":22},"线槽转角或分支处",{"key":61,"text":324,"correct":22},"直线段不大于3m处","ABDE",{"id":327,"libraryId":5,"type":48,"typeLabel":49,"stem":328,"options":329,"answer":340,"analysis":33},936417,"可燃气体探测报警系统是火灾自动报警系统的独立子系统，属于火灾预警系统，下列组件属于可燃气体探测报警装置组成部分的是（ ）。",[330,332,334,336,338],{"key":20,"text":331,"correct":22},"火灾声光警报器",{"key":24,"text":333,"correct":26},"消火栓按钮",{"key":28,"text":335,"correct":22},"可燃气体探测器",{"key":31,"text":337,"correct":22},"可燃气体报警控制器",{"key":61,"text":339,"correct":26},"火灾报警控制器","ACD",{"id":342,"libraryId":5,"type":48,"typeLabel":49,"stem":343,"options":344,"answer":340,"analysis":33},936418,"某消防技术服务机构对建筑内安装的火灾自动报警系统进行检查，下列关于线路安装质量的检查结果中，不符合现行国家消防技术标准要求的有（ ）。",[345,347,349,351,353],{"key":20,"text":346,"correct":22},"部分端子板上接了4根导线",{"key":24,"text":348,"correct":26},"报警总线采用阻燃耐火电线电缆",{"key":28,"text":350,"correct":22},"控制器的主电源使用电源插头与消防电源连接",{"key":31,"text":352,"correct":22},"引入控制器内的导线留有150mm的余量",{"key":61,"text":354,"correct":26},"系统供电线路采用耐火铜芯电线电缆",{"id":356,"libraryId":5,"type":48,"typeLabel":49,"stem":357,"options":358,"answer":369,"analysis":33},936419,"某消防技术服务单位对一大型工业企业内设置的火灾报警系统进行检查，发现如下内容，其中符合国家消防技术标准的是（ ）。",[359,361,363,365,367],{"key":20,"text":360,"correct":22},"火灾报警控制器与总线采用端子板进行连接，有个别接线端接有2根导线",{"key":24,"text":362,"correct":22},"消防控制室内火灾报警控制器采用落地安装方式，底部高出地面20cm",{"key":28,"text":364,"correct":22},"电缆桥架内敷设的缆式线型感温火灾探测器采用专用接线盒连接",{"key":31,"text":366,"correct":26},"电缆桥架内敷设的缆式线型感温火灾探测器弯曲半径为0．1m",{"key":61,"text":368,"correct":26},"模块箱内安装的模块，个别留有120mm余量的导线","ABC",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":33},936420,"区域显示器应设置在出入口等明显和便于操作的部位。当采用壁挂方式安装时，其底边距地高度宜为（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"1.3m～1.5m",{"key":24,"text":377,"correct":26},"1.1m～1.3m",{"key":28,"text":379,"correct":26},"1.5m～1.8m",{"key":31,"text":381,"correct":26},"1.2m～1.5m",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":31,"analysis":33},936421,"下列组件中，不属于探测报警系统的是（ ）。",[386,387,388,390],{"key":20,"text":339,"correct":26},{"key":24,"text":331,"correct":26},{"key":28,"text":389,"correct":26},"感烟火灾探测器",{"key":31,"text":391,"correct":22},"消防电话",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":20,"analysis":33},936422,"下列关于剩余电流式电气火灾监控探测器设置的要求说法中不正确的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"剩余电流式电气火灾监控探测器宜设置在最末一级级配电柜（箱）的出线端",{"key":24,"text":399,"correct":26},"剩余电流式电气火灾监控探测器不宜设置在 IT 系统的配电线路和消防配线路中",{"key":28,"text":401,"correct":26},"选择剩余电流式电气火灾监控探测器时,探测器报警值宜为 300mA~500mA",{"key":31,"text":403,"correct":26},"具有探测线路故障电弧功能的电气火灾监控探测器,其保护线路的长度不宜大于 100m",{"id":405,"libraryId":5,"type":48,"typeLabel":49,"stem":406,"options":407,"answer":418,"analysis":33},936423,"某场所净空高度为18m，设有线型光束感烟火灾探测器，对该探测器安装情况的检查结果如下，其中符合现行国家消防技术标准要求的是（ ）。",[408,410,412,414,416],{"key":20,"text":409,"correct":22},"光束轴线距顶棚的垂直距离为0．5m",{"key":24,"text":411,"correct":22},"发射器和接收器之间的探测区域长度为50m",{"key":28,"text":413,"correct":26},"相邻两组探测器的水平距离为15m",{"key":31,"text":415,"correct":22},"探测器至侧墙水平距离最大距离为5m",{"key":61,"text":417,"correct":26},"探测器至侧墙水平距离最小距离为0．2m","ABD",{"id":420,"libraryId":5,"type":48,"typeLabel":49,"stem":421,"options":422,"answer":369,"analysis":33},936424,"对某建筑内安装的火灾自动报警系统进行检测验收，检测结果如下，其中判定结果为A类不合格的是（ ）。",[423,425,427,429,431],{"key":20,"text":424,"correct":22},"系统内某一探测器无法发出报警信号",{"key":24,"text":426,"correct":22},"系统内两处报警控制器无法发出报警信号",{"key":28,"text":428,"correct":22},"探测器规格、型号与设计不符",{"key":31,"text":430,"correct":26},"工程质量事故处理报告不全",{"key":61,"text":432,"correct":26},"探测器备用量不足",{"id":434,"libraryId":5,"type":48,"typeLabel":49,"stem":435,"options":436,"answer":447,"analysis":33},936425,"在对建筑中由火灾自动报警系统联动启动的雨淋喷水灭火系统进行检测时，应检测雨淋阀组联动控制功能，根据现行国家消防技术标准的规定，下列关于开启雨淋阀组的联动触发信号的说法中，正确的有（ ）。",[437,439,441,443,445],{"key":20,"text":438,"correct":22},"同一报警区域内两个及以上独立的感温火灾探测器的报警信号",{"key":24,"text":440,"correct":26},"同一报警区域内两个及以上独立的感烟火灾探测器的报警信号",{"key":28,"text":442,"correct":26},"同一报警区域内一个感烟火灾探测器与一个手动火灾报警按钮的报警信号",{"key":31,"text":444,"correct":26},"同一报警区域内一个感烟火灾探测器与一个感温火灾探测器的报警信号",{"key":61,"text":446,"correct":22},"同一报警区域内一个感温火灾探测器与一个手动火灾报警按钮的报警信号","AE",{"id":449,"libraryId":5,"type":48,"typeLabel":49,"stem":450,"options":451,"answer":418,"analysis":33},936426,"某商场消防设施维护保养人员发现，该商场地下车库的个别点型感烟探测器经常发出误报。下列故障可能发生原因分析的说法中，正确的有（ ）。",[452,454,456,458,460],{"key":20,"text":453,"correct":22},"探测器稳定性差",{"key":24,"text":455,"correct":22},"探测器设置高度过低",{"key":28,"text":457,"correct":26},"探测器距离高温光源过近",{"key":31,"text":459,"correct":22},"探测器的灵敏度过高",{"key":61,"text":461,"correct":26},"周边气流影响过大",{"id":463,"libraryId":5,"type":48,"typeLabel":49,"stem":464,"options":465,"answer":476,"analysis":33},936427,"消防设施检测机构对某商场设置的防火卷帘系统进行检测，在检测联动控制功能时，根据现行国家消防技术标准，下列关于设置在疏散通道上的防火卷帘联动控制的说法中，正确的有（ ）。",[466,468,470,472,474],{"key":20,"text":467,"correct":22},"防火分区内任两只独立的感烟火灾探测器的报警信号应联动控制防火卷帘下降至距楼板面1.8m处",{"key":24,"text":469,"correct":22},"防火分区内任一只专门用于联动防火卷帘的感烟火灾探测器的报警信号应联动控制防火卷帘下降至距楼板面1.8m处",{"key":28,"text":471,"correct":22},"任一只专门用于联动防火卷帘的感温火灾探测器的报警信号应联动控制防火卷帘下降到楼板面",{"key":31,"text":473,"correct":26},"任一只防火卷帘附近的手动报警按钮的报警信号应联动控制防火卷帘下降到楼板面",{"key":61,"text":475,"correct":22},"专门用于联动某个防火卷帘的感温火灾探测器不应少于2只","ABCE",{"id":478,"libraryId":5,"type":48,"typeLabel":49,"stem":479,"options":480,"answer":325,"analysis":33},936428,"对火灾自动报警系统实施检测维护，每年度应开展一次检查和试验的项目有（ ）。",[481,483,485,487,489],{"key":20,"text":482,"correct":22},"火灾报警控制器报警功能",{"key":24,"text":484,"correct":22},"防火门监控器故障报警功能",{"key":28,"text":486,"correct":26},"风机控制柜手动控制功能",{"key":31,"text":488,"correct":22},"非消防电源联动控制功能",{"key":61,"text":490,"correct":22},"火灾显示盘报警显示功能",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":28,"analysis":33},936429,"下列关于火灾自动报警系统的布线说法，符合现行国家工程建设消防技术标准的是（ ）。",[495,497,499,501],{"key":20,"text":496,"correct":26},"从线槽引到控制设备的导线采用金属软管保护时，导线的长度不应大于1m",{"key":24,"text":498,"correct":26},"火灾自动报警系统内不同电压等级、不同电流类别的线路，应布在同一管内或线槽的同一槽孔内",{"key":28,"text":500,"correct":22},"导线在管内或线槽内，不应有接头或扭结，导线的接头，应在接线盒内采用焊接、压接、接线端子可靠连接。",{"key":31,"text":502,"correct":26},"在管内或槽盒内的布线，应在建筑抹灰及地面工程结束前进行，管内或槽盒内不应有积水及杂物。",{"id":504,"libraryId":5,"type":48,"typeLabel":49,"stem":505,"options":506,"answer":325,"analysis":33},936430,"根据国家标准《建筑消防设施的维护管理》GB 25201，对火灾自动报警系统消防联动控制器的检测内容，主要包括（ ）。",[507,509,511,513,515],{"key":20,"text":508,"correct":22},"控制器显示功能",{"key":24,"text":510,"correct":22},"备用电源充、放电功能",{"key":28,"text":512,"correct":26},"自检功能",{"key":31,"text":514,"correct":22},"消防联动控制器手、自动联动控制功能",{"key":61,"text":516,"correct":22},"主、备电切换功能",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},936431,"对某建筑的消防应急广播进行联动控制检查的结果如下，其中检查方法与结果不符合规范要求的是（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":26},"使消防应急广播控制设备与扬声器间的广播信息传输线路断路，消防应急广播控制设备在80s内发出故障信号，并显示出故障部位",{"key":24,"text":524,"correct":22},"消防应急广播系统与普通广播或背景音乐广播系统合用时，消防应急广播控制装置应正常广播",{"key":28,"text":526,"correct":26},"每个回路任意抽取一个扬声器，使其处于断路状态，其他扬声器的工作状态不应受影响",{"key":31,"text":528,"correct":26},"消防应急广播的单次语音播放时间为20s，与火灾声警报器分时交替工作",{"id":530,"libraryId":5,"type":48,"typeLabel":49,"stem":531,"options":532,"answer":543,"analysis":33},936432,"根据《火灾自动报警系统设计规范》（GB50116-2013）的规定，可以作为排烟风机联动触发信号的有（ ）。",[533,535,537,539,541],{"key":20,"text":534,"correct":26},"同一防烟分区内两只感烟探测器",{"key":24,"text":536,"correct":26},"同一防烟分区内一只感烟探测器和一只感温探测器",{"key":28,"text":538,"correct":22},"排烟口开启的动作信号",{"key":31,"text":540,"correct":22},"排烟窗开启的动作信号",{"key":61,"text":542,"correct":22},"排烟阀开启的动作信号","CDE",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":28,"analysis":33},936433,"下列关于某建筑的火灾自动报警系统中火灾探测器的检查结果，符合规范要求的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":26},"感烟、感温火灾探测器倾斜安装，且倾角为50°",{"key":24,"text":551,"correct":26},"感烟、感温火灾探测器底座连接导线留有100mm的余量",{"key":28,"text":553,"correct":22},"感烟、感温火灾探测器至墙壁的水平距离0．7m",{"key":31,"text":555,"correct":26},"感烟火灾探测器设置在镂空面积与总面积的比例为15％格栅吊顶场所时，设置在吊顶上方",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":20,"analysis":33},936434,"对某竣工的火灾自动报警系统进行验收时发现一个火灾探测器无法发出报警信号，则关于该火灾自动报警系统工程质量是否合格的说法，正确的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"不合格",{"key":24,"text":563,"correct":26},"合格",{"key":28,"text":565,"correct":26},"有可能不合格",{"key":31,"text":567,"correct":26},"无法判定",{"id":569,"libraryId":5,"type":48,"typeLabel":49,"stem":570,"options":571,"answer":582,"analysis":33},936435,"下列关于气体灭火系统的联动控制检查，符合规范要求的是（ ）。",[572,574,576,578,580],{"key":20,"text":573,"correct":22},"气体灭火控制器由防护区内两个独立的感烟火灾探测器自动控制",{"key":24,"text":575,"correct":22},"气体灭火控制器由防护区内一个独立的感烟火灾探测器和一个独立的感温火灾探测器自动控制",{"key":28,"text":577,"correct":26},"气体灭火控制器在接收到符合逻辑关系的两个联动触发信号后，启动该防护区内的声光报警器",{"key":31,"text":579,"correct":26},"启动气体灭火装置之后，启动设置在防护区入口处表示气体喷洒的火灾声光警报器",{"key":61,"text":581,"correct":22},"平时无人工作的防护区设置为无延迟的喷射","ABE",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":24,"analysis":33},936436,"某场所安装了相同规格型号的离子感烟火灾探测器300只，在使用维护阶段应至少储备（ ）只相同规格型号的探测器作为备用。",[587,588,589,590],{"key":20,"text":259,"correct":26},{"key":24,"text":135,"correct":22},{"key":28,"text":210,"correct":26},{"key":31,"text":157,"correct":26},{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":31,"analysis":33},936437,"消防联动控制系统中消防电话插孔，实际数量10只，抽验（ ）只。",[595,596,597,598],{"key":20,"text":112,"correct":26},{"key":24,"text":135,"correct":26},{"key":28,"text":137,"correct":26},{"key":31,"text":110,"correct":22},{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":20,"analysis":33},936438,"某建筑内部共安装了80只独立式感烟火灾探测器，在对该建筑火灾报警系统进行检测验收时，应至少抽取（ ）只独立式感烟火灾探测器进行模拟火灾响应和故障信号检验。",[603,605,607,608],{"key":20,"text":604,"correct":22},"80",{"key":24,"text":606,"correct":26},"20",{"key":28,"text":112,"correct":26},{"key":31,"text":204,"correct":26},{"id":610,"libraryId":5,"type":48,"typeLabel":49,"stem":611,"options":612,"answer":623,"analysis":33},936439,"消防技术服务机构对某建筑设置的临时高压消防给水系统进行检查，打开试验管放水，消防水泵出水干管上的低压压力开关动作，消防联动控制器上显示低压压力开关动作，但消防水泵没有启动，对此现象原因进行分析，下列说法正确的是（ ）。",[613,615,617,619,621],{"key":20,"text":614,"correct":26},"低压压力开关损坏",{"key":24,"text":616,"correct":22},"低压压力开关至消防水泵控制柜之间的线路断路",{"key":28,"text":618,"correct":22},"消防水泵控制柜处于手动控制状态",{"key":31,"text":620,"correct":26},"消防联动控制器处于手动控制状态",{"key":61,"text":622,"correct":22},"消防水泵损坏","BCE",{"id":625,"libraryId":5,"type":15,"typeLabel":16,"stem":626,"options":627,"answer":28,"analysis":33},936440,"下列组件中，不属于消防联动控制系统组成部件的是（ ）。",[628,629,631,633],{"key":20,"text":333,"correct":26},{"key":24,"text":630,"correct":26},"消防联动控制器",{"key":28,"text":632,"correct":22},"火灾探测器",{"key":31,"text":391,"correct":26},{"id":635,"libraryId":5,"type":15,"typeLabel":16,"stem":636,"options":637,"answer":24,"analysis":33},936441,"可燃气体报警控制器落地安装时，其底边宜高出地面（ ）m。",[638,640,642,644],{"key":20,"text":639,"correct":26},"0.3-0.4",{"key":24,"text":641,"correct":22},"0.1-0.2",{"key":28,"text":643,"correct":26},"0.2-0.3",{"key":31,"text":645,"correct":26},"0.4-0.5",[647,650,653,656,659,662],{"id":15,"name":648,"category":7,"favorite":649},"领导干部任职前廉政法规知识测试题",92,{"id":651,"name":652,"category":7,"favorite":15},595,"建筑结构与设备",{"id":654,"name":655,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":657,"name":658,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":660,"name":661,"category":7,"favorite":8},534,"BIM工程师",{"id":663,"name":661,"category":7,"favorite":8},535]