[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-33":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":646},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,33,50,2974,[13,38,53,67,81,93,105,117,128,140,152,164,176,188,200,215,230,245,257,269,281,293,301,313,324,333,348,362,377,389,401,413,425,437,449,461,473,484,496,507,518,530,542,554,566,580,595,610,622,634],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},936290,2,"多选题","每具经维修出厂检验合格的灭火器应加贴维修合格证，下列属于维修合格证内容的是（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","灭火器型号",false,{"key":24,"text":25,"correct":26},"B","总质量",true,{"key":28,"text":29,"correct":26},"C","维修编号",{"key":31,"text":32,"correct":26},"D","维修日期",{"key":34,"text":35,"correct":22},"E","灭火器保护距离","BCD","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},936291,"下列关于建筑灭火器配置验收时检查数量的说法，正确的是（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"灭火器类型、规格、灭火级别、配置数量检查，随机抽查20％的配置单元，且不少于3个，少于3个配置单元的全数检查",{"key":24,"text":45,"correct":26},"灭火器的保护距离检查，随机抽查20％的配置单元，少于3个配置单元的全数检查",{"key":28,"text":47,"correct":22},"灭火器的位置标识检查，随机抽查20％的配置单元，且不少于3个",{"key":31,"text":49,"correct":22},"同一灭火器配置单元内灭火器的相容性检查，随机抽查30％",{"key":34,"text":51,"correct":26},"灭火器的合格手续检查，全数检查","ABE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":36,"analysis":37},936292,"灭火器日常检查中，发现灭火器达到维修条件或维修期限时，建筑使用管理单位应及时按照规定程序送修，以下应及时送修的有（ ）的灭火器。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"未曾使用过但出厂期刚满2年",{"key":24,"text":60,"correct":26},"机械损伤",{"key":28,"text":62,"correct":26},"筒体明显锈蚀",{"key":31,"text":64,"correct":26},"灭火剂泄漏",{"key":34,"text":66,"correct":22},"再次维修以后刚满2年",{"id":68,"libraryId":5,"type":69,"typeLabel":70,"stem":71,"options":72,"answer":31,"analysis":37},936293,1,"单选题","下列关于风机安装的说法中，错误的是（ ）。",[73,75,77,79],{"key":20,"text":74,"correct":22},"风机外壳至墙壁的距离应不小于600mm",{"key":24,"text":76,"correct":22},"排烟系统与通风空调系统共用风机且需要设置减振装置时，不应使用橡胶减振装置",{"key":28,"text":78,"correct":22},"吊装风机的支架、吊架应焊接牢固、安装可靠",{"key":31,"text":80,"correct":26},"风机驱动装置设置在机房内时，外露部位可不设防护罩",{"id":82,"libraryId":5,"type":69,"typeLabel":70,"stem":83,"options":84,"answer":20,"analysis":37},936294,"下列设备需每季进行检查的是（ ）。",[85,87,89,91],{"key":20,"text":86,"correct":26},"防烟排烟风机",{"key":24,"text":88,"correct":22},"送风口",{"key":28,"text":90,"correct":22},"排烟防火阀",{"key":31,"text":92,"correct":22},"排烟口",{"id":94,"libraryId":5,"type":69,"typeLabel":70,"stem":95,"options":96,"answer":24,"analysis":37},936295,"对某建筑内设置的排烟口进行检查，下列检查结果中，符合现行国家消防技术标准的是（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"建筑内设有自动喷水灭火系统，排烟口与该排烟口所在防烟分区内最远点的水平距离为37．5m",{"key":24,"text":100,"correct":26},"测试排烟口的风速为8m／s",{"key":28,"text":102,"correct":22},"设置在走道侧墙上的排烟口距离防烟楼梯间的门的距离为0．5m",{"key":31,"text":104,"correct":22},"房间的吊顶采用难燃材料制作，排烟口设置在吊顶内并通过吊顶上部空间进行排烟",{"id":106,"libraryId":5,"type":69,"typeLabel":70,"stem":107,"options":108,"answer":28,"analysis":37},936296,"活动挡烟垂壁的调试检查方法不包括（ ）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"动作检查",{"key":24,"text":112,"correct":22},"观察",{"key":28,"text":114,"correct":26},"测定",{"key":31,"text":116,"correct":22},"记录",{"id":118,"libraryId":5,"type":69,"typeLabel":70,"stem":119,"options":120,"answer":20,"analysis":37},936297,"下列建筑防烟排烟系统周期性检查维护项目中，不属于季度检查项目的是（ ）。",[121,123,124,126],{"key":20,"text":122,"correct":26},"风机流量压力性能测试",{"key":24,"text":86,"correct":22},{"key":28,"text":125,"correct":22},"活动挡烟垂壁",{"key":31,"text":127,"correct":22},"自动排烟窗",{"id":129,"libraryId":5,"type":69,"typeLabel":70,"stem":130,"options":131,"answer":28,"analysis":37},936298,"对某建筑防烟排烟系统进行检查时，符合现行国家工程消防技术标准要求的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":22},"加压送风管道采用难燃材料制作",{"key":24,"text":135,"correct":22},"安装排烟管道时，应采取隔热防火措施或与可燃物保持不小于100 mm的距离",{"key":28,"text":137,"correct":26},"排烟风机应保证在280℃的环境条件下能连续工作不少于30 min",{"key":31,"text":139,"correct":22},"固定式挡烟垂壁可采用隔墙、楼板下不小于100 mm的梁或吊顶下凸出不小于100 mm的不燃烧体",{"id":141,"libraryId":5,"type":69,"typeLabel":70,"stem":142,"options":143,"answer":28,"analysis":37},936299,"某高层写字楼，建筑高度为105m，避难层的地面面积为1100m2，采用自然通风的方式，在不同朝向均设置了可开启外窗。各外窗的有效面积之和最小为（ ）m2。",[144,146,148,150],{"key":20,"text":145,"correct":22},"10",{"key":24,"text":147,"correct":22},"11",{"key":28,"text":149,"correct":26},"22",{"key":31,"text":151,"correct":22},"25",{"id":153,"libraryId":5,"type":69,"typeLabel":70,"stem":154,"options":155,"answer":31,"analysis":37},936300,"在对建筑进行防烟分区检查时，应注意检查挡烟垂壁的安装是否满足现行国家消防技术标准的要求。下列关于活动挡烟垂壁安装的说法中，正确的是（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":22},"活动挡烟垂壁与建筑结构墙面的缝隙不应大于70mm",{"key":24,"text":159,"correct":22},"两块或两块以上的挡烟垂帘组成的连续性挡烟垂壁，各块之间的缝隙不应大于20mm",{"key":28,"text":161,"correct":22},"活动挡烟垂壁与建筑结构墙面的缝隙不应大于80mm",{"key":31,"text":163,"correct":26},"两块或两块以上的挡烟垂帘组成的连续性挡烟垂壁，各块之间不应有缝隙，搭接宽度不应小于100mm",{"id":165,"libraryId":5,"type":69,"typeLabel":70,"stem":166,"options":167,"answer":28,"analysis":37},936301,"建筑内排烟口的设置宜使烟气方向与人员疏散方向（ ），排烟口与附近安全出口相邻边缘之间的水平距离不应小于（ ）m。",[168,170,172,174],{"key":20,"text":169,"correct":22},"相同，1．5",{"key":24,"text":171,"correct":22},"相反，2．0",{"key":28,"text":173,"correct":26},"相反，1．5",{"key":31,"text":175,"correct":22},"相同，2．0",{"id":177,"libraryId":5,"type":69,"typeLabel":70,"stem":178,"options":179,"answer":31,"analysis":37},936302,"对某厂区的两栋工业建筑内防排烟系统的设置情况进行检查，其中焦炭厂房的建筑高度为50m，焦煤仓库的建筑高度为24m，仓库占地面积为1500m2，下列检查结果中，不符合现行国家技术标准要求的是（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":22},"焦炭厂房采用自然通风系统",{"key":24,"text":183,"correct":22},"地上二层的厂房内面积为300m2的办公室未设置排烟设施",{"key":28,"text":185,"correct":22},"焦煤仓库采用机械排烟系统",{"key":31,"text":187,"correct":26},"焦炭厂房内长度为40m的疏散走道未设置排烟设施",{"id":189,"libraryId":5,"type":69,"typeLabel":70,"stem":190,"options":191,"answer":28,"analysis":37},936303,"下列不属于防排烟系统中活动挡烟垂壁的调试的是（ ）。",[192,194,196,198],{"key":20,"text":193,"correct":22},"手动操作挡烟垂壁按钮进行开启、复位试验，挡烟垂壁应灵敏、可靠地启动与到位后停止，下降高度符合设计要求",{"key":24,"text":195,"correct":22},"模拟火灾，相应区域火灾报警后，同一防烟区域内挡烟垂壁应联动下降到设计高度",{"key":28,"text":197,"correct":26},"活动挡烟垂壁关闭后应能联动相应的风机停止",{"key":31,"text":199,"correct":22},"挡烟垂壁下降到设计高度后应能将状态信号反馈到消防控制室",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":214,"analysis":37},936304,"在对某高度为60m的办公楼设置的防烟排烟系统检查时获取的下列信息中，符合现行国家技术标准的有（ ）。",[204,206,208,210,212],{"key":20,"text":205,"correct":22},"防烟楼梯间内采用直灌式加压送风系统",{"key":24,"text":207,"correct":26},"防烟楼梯间前室内设置常闭式送风口",{"key":28,"text":209,"correct":26},"机械加压送风管道井壁上的检修门为乙级防火门",{"key":31,"text":211,"correct":22},"送风机与排烟风机合用机房，机房内设置自动喷水灭火系统",{"key":34,"text":213,"correct":22},"一个排烟系统负担多个防烟分区，只在排烟风机入口总管上设置了排烟防火阀","BC",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":229,"analysis":37},936305,"防烟系统是防止火灾烟气在楼梯间、前室、避难层筹空间聚集的系统，下列关于建筑物防烟方式的选择，设计方案不正确的有（ ）",[219,221,223,225,227],{"key":20,"text":220,"correct":26},"某一类高层住宅楼，楼梯间采用自然通风，项部未设置开口，合用前室采用机械加压送风，风口设置在顶部",{"key":24,"text":222,"correct":26},"某公寓楼60m,合用前室采用敞开的阳台，楼梯间未设置防烟设施",{"key":28,"text":224,"correct":26},"某住宅楼80m,采用剪刀楼梯间，共用前室与消防电梯前室合用，剪刀楼梯间与合用前室均采用自然通风",{"key":31,"text":226,"correct":26},"某地下商业场所划分若干防火分区，其避难走道仅服务一个防火分区且仅设置一个安全出口，仅在前室设置了机械加压送风系统",{"key":34,"text":228,"correct":22},"某超高层酒店，避难层四周设置可开启外窗，未设置机械加压送风系统","ABCD",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":244,"analysis":37},936306,"对某公共建筑内的防烟排烟系统调试，根据《建筑防烟排烟系统技术标准》GB 51251—2017的相关要求，下列关于调试的要求做法中，正确的是（ ）。",[234,236,238,240,242],{"key":20,"text":235,"correct":26},"当任何一个常闭送风口开启时，相应的送风机均应能联动启动",{"key":24,"text":237,"correct":22},"手动开启风机，风机应正常运转3．0h，叶轮旋转方向应正确、运转平稳",{"key":28,"text":239,"correct":26},"对楼梯间和前室的机械加压送风系统调试应单独分别进行，且互不影响",{"key":31,"text":241,"correct":26},"有补风要求的机械排烟场所，当火灾确认后，补风系统应启动",{"key":34,"text":243,"correct":26},"当任何一个常闭排烟阀或排烟口开启时，排烟风机均应能联动启动","ACDE",{"id":246,"libraryId":5,"type":69,"typeLabel":70,"stem":247,"options":248,"answer":31,"analysis":37},936307,"对防烟排烟系统组件进行现场检查，下列检查结果不符合规范要求的是（ ）。",[249,251,253,255],{"key":20,"text":250,"correct":22},"排烟防火阀规格、型号符合设计要求，手动开启灵活、关闭可靠严密",{"key":24,"text":252,"correct":22},"防火阀动作可靠，在最大工作压力下工作正常",{"key":28,"text":254,"correct":22},"送风口其规格、型号应符合设计要求，手动开启灵活、关闭可靠严密",{"key":31,"text":256,"correct":26},"柔性短管制作材料的燃烧性能为B1级",{"id":258,"libraryId":5,"type":69,"typeLabel":70,"stem":259,"options":260,"answer":31,"analysis":37},936308,"某消防检测机构对建筑防烟排烟系统设置情况进行检查。下列检查结果中，符合现行国家消防技术标准要求的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":22},"教学建筑内长度为25m的疏散走道未设置排烟设施",{"key":24,"text":264,"correct":22},"地下一层1个50m2的KTV房间内未设置排烟设施",{"key":28,"text":266,"correct":22},"四层1个150m2的办公室内未设置排烟设施",{"key":31,"text":268,"correct":26},"三层1个50m2的游戏室内未设置排烟设施",{"id":270,"libraryId":5,"type":69,"typeLabel":70,"stem":271,"options":272,"answer":24,"analysis":37},936309,"排烟口的安装位置应符合设计要求，与可燃物或可燃构件的距离不应小于（ ）mm。",[273,275,277,279],{"key":20,"text":274,"correct":22},"1000",{"key":24,"text":276,"correct":26},"1500",{"key":28,"text":278,"correct":22},"2000",{"key":31,"text":280,"correct":22},"2500",{"id":282,"libraryId":5,"type":69,"typeLabel":70,"stem":283,"options":284,"answer":24,"analysis":37},936310,"根据《建筑防烟排烟系统技术标准》GB 51251—2017的要求，挡烟垂壁应（ ）进行一次功能检测启动试验及供电线路检查。",[285,287,289,291],{"key":20,"text":286,"correct":22},"月",{"key":24,"text":288,"correct":26},"季度",{"key":28,"text":290,"correct":22},"半年",{"key":31,"text":292,"correct":22},"年",{"id":294,"libraryId":5,"type":69,"typeLabel":70,"stem":295,"options":296,"answer":31,"analysis":37},936312,"某场所设置的防烟排烟系统采用无机玻璃钢风管，按照规范规定，每（ ）应对该风管进行质量检查。",[297,298,299,300],{"key":20,"text":286,"correct":22},{"key":24,"text":288,"correct":22},{"key":28,"text":290,"correct":22},{"key":31,"text":292,"correct":26},{"id":302,"libraryId":5,"type":69,"typeLabel":70,"stem":303,"options":304,"answer":20,"analysis":37},936313,"在防烟排烟系统中，系统组件在正常工作状态下的启闭状态是不同的，关于防烟排烟系统组件启闭状态的说法中，正确的是（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":26},"加压送风口既有常开式，也有常闭式",{"key":24,"text":308,"correct":22},"排烟防火阀及排烟阀平时均呈开启状态",{"key":28,"text":310,"correct":22},"排烟防火阀及排烟阀平时均呈关闭状态",{"key":31,"text":312,"correct":22},"自垂百叶式加压送风口平时呈开启状态",{"id":314,"libraryId":5,"type":69,"typeLabel":70,"stem":315,"options":316,"answer":31,"analysis":37},936314,"对建筑防烟排烟系统的运行进行周期性维护管理时，下列项目中不属于每半年检查项目的是（ ）。",[317,319,320,322],{"key":20,"text":318,"correct":22},"防火阀",{"key":24,"text":92,"correct":22},{"key":28,"text":321,"correct":22},"送风口（阀）",{"key":31,"text":323,"correct":26},"联动功能",{"id":325,"libraryId":5,"type":69,"typeLabel":70,"stem":326,"options":327,"answer":20,"analysis":37},936315,"对建筑防烟排烟系统进行周期性维护管理，下列检查项目中，不属于每季度检查项目的是（ ）。",[328,329,330,332],{"key":20,"text":92,"correct":26},{"key":24,"text":125,"correct":22},{"key":28,"text":331,"correct":22},"排烟风机",{"key":31,"text":127,"correct":22},{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":347,"analysis":37},936316,"某消防技术服务机构对已完工的防烟排烟系统进行检查，下列有关排烟防火阀设置位置的检查结果中，符合规范要求的有（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":22},"排烟风机的出口处设置了排烟防火阀",{"key":24,"text":340,"correct":26},"垂直风管与每层水平风管交接处的水平管段上设置了排烟防火阀",{"key":28,"text":342,"correct":22},"送风机的入口处设置了排烟防火阀",{"key":31,"text":344,"correct":26},"穿越防火分区处设置了排烟防火阀",{"key":34,"text":346,"correct":26},"一个排烟系统中负担多个防烟分区的排烟支管上","BDE",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":244,"analysis":37},936317,"防烟排烟系统调试在系统施工完成及与工程有关的火灾自动报警系统及联动控制设备调试合格后进行，对排烟防火阀的调试要求包括（ ）。",[352,354,356,358,360],{"key":20,"text":353,"correct":26},"进行手动关闭、复位试验，阀门动作应灵敏、可靠，关闭应严密",{"key":24,"text":355,"correct":22},"模拟火灾，相应区域火灾报警后，相邻防火分区内排烟管道上的其他阀门应联动关闭",{"key":28,"text":357,"correct":26},"阀门关闭后的状态信号应能反馈到消防控制室",{"key":31,"text":359,"correct":26},"阀门关闭后应能联动相应的风机停止",{"key":34,"text":361,"correct":26},"排烟防火阀的调试数量应为全数调试",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":376,"analysis":37},936318,"消防设施检测机构对某商场的防排烟系统进行检测验收，检测记录的下列结果中，不符合现行国家消防技术标准要求的是（ ）。",[366,368,370,372,374],{"key":20,"text":367,"correct":22},"手动打开某防烟分区内的排烟阀，对应的排烟风机能联动启动",{"key":24,"text":369,"correct":22},"模拟火灾，发出报警信号后，相关部位的送风口和送风机启动",{"key":28,"text":371,"correct":22},"手动关闭排烟风机入口处的排烟防火阀，排烟风机停止运转",{"key":31,"text":373,"correct":26},"在挡烟垂壁附近的一只感烟探测器附近模拟烟气，挡烟垂壁降落",{"key":34,"text":375,"correct":26},"经测量，加压送风口处的风速为8.5m\u002Fs","DE",{"id":378,"libraryId":5,"type":69,"typeLabel":70,"stem":379,"options":380,"answer":20,"analysis":37},936319,"下列关于防排烟系统风管的安装与检测描述不正确的是（）。",[381,383,385,387],{"key":20,"text":382,"correct":26},"风管与砖、混凝土风道的连接接口，应逆着气流方向插入，并应采取密封措施",{"key":24,"text":384,"correct":22},"风管与风机的连接宜采用法兰连接，或采用不燃材料的柔性短管连接。若风机仅用于防烟、排烟时，则不宜采用柔性连接",{"key":28,"text":386,"correct":22},"风管与风机连接若有转弯处宜加装导流叶片，保证气流顺畅",{"key":31,"text":388,"correct":22},"风管穿越隔墙或楼板时，风管与隔墙之间的空隙，应采用水泥砂浆等不燃材料严密填塞",{"id":390,"libraryId":5,"type":69,"typeLabel":70,"stem":391,"options":392,"answer":24,"analysis":37},936321,"下列对某建筑的防排烟系统的联动控制的检测结果中，符合规范要求的是（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"将防烟系统设置在自动状态，通过消防控制室内的手动开关，不能启动加压送风机和开启送风口",{"key":24,"text":396,"correct":26},"将防烟系统设置在自动状态，某防火分区内一只火灾探测器探测到火灾信号，现场人员按动手动报警按钮，送风口启动，联动加压送风机启动",{"key":28,"text":398,"correct":22},"将防烟系统设置在自动状态，A和B防火分区内各有一只火灾探测器探测到火灾，送风口启动，联动加压送风机启动",{"key":31,"text":400,"correct":22},"将防烟系统设置在手动状态，某防火分区内两只感烟火灾探测器探测到火灾信号，送风口启动，联动加压送风机启动",{"id":402,"libraryId":5,"type":69,"typeLabel":70,"stem":403,"options":404,"answer":24,"analysis":37},936322,"某消防检测维保机构对某建筑的防排烟系统进行维保检测，以下不符合规范要求的是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"设置在房间吊顶内的排烟管道，耐火极限为0．5h",{"key":24,"text":408,"correct":26},"常闭送风口的手动驱动装置距离楼地面1．2m",{"key":28,"text":410,"correct":22},"排烟口设置在靠近顶棚的墙面上",{"key":31,"text":412,"correct":22},"排烟机房中排烟风机距离墙壁0．7m",{"id":414,"libraryId":5,"type":69,"typeLabel":70,"stem":415,"options":416,"answer":20,"analysis":37},936323,"排烟风机应保证在280℃的环境条件下能连续工作不少于（）min。",[417,419,421,423],{"key":20,"text":418,"correct":26},"30",{"key":24,"text":420,"correct":22},"40",{"key":28,"text":422,"correct":22},"60",{"key":31,"text":424,"correct":22},"120",{"id":426,"libraryId":5,"type":69,"typeLabel":70,"stem":427,"options":428,"answer":31,"analysis":37},936324,"下列关于机械加压送风的防烟设施的说法，错误的是（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":22},"加压送风机宜采用中、低压离心风机或轴流风机",{"key":24,"text":432,"correct":22},"常闭式送风口采用手动或电动开启，常用于前室或合用前室",{"key":28,"text":434,"correct":22},"自垂百叶式送风口平时靠百叶重力自行关闭，加压时自行开启，常用于防烟楼梯间",{"key":31,"text":436,"correct":26},"机械加压送风的防烟设施包括加压送风机、加压送风管道、加压送风口、挡烟垂壁等",{"id":438,"libraryId":5,"type":69,"typeLabel":70,"stem":439,"options":440,"answer":24,"analysis":37},936325,"排烟风机与加压送风机的不同在于，排烟风机应保证在（ ）℃的环境条件下能连续工作不少于（ ）min。",[441,443,445,447],{"key":20,"text":442,"correct":22},"70，30",{"key":24,"text":444,"correct":26},"280，30",{"key":28,"text":446,"correct":22},"280，70",{"key":31,"text":448,"correct":22},"70，70",{"id":450,"libraryId":5,"type":69,"typeLabel":70,"stem":451,"options":452,"answer":31,"analysis":37},936326,"在对排烟风机进行调试时，手动开启风机，风机应正常运转（ ）h，叶轮旋转方向应正确、运转平稳、无异常振动与声响。",[453,455,457,459],{"key":20,"text":454,"correct":22},"0．5",{"key":24,"text":456,"correct":22},"1．0",{"key":28,"text":458,"correct":22},"1．5",{"key":31,"text":460,"correct":26},"2．0",{"id":462,"libraryId":5,"type":69,"typeLabel":70,"stem":463,"options":464,"answer":20,"analysis":37},936327,"对某商场设置的防烟排烟系统进行验收，发现活动的挡烟垂壁不能手动开启，下列关于该工程是否合格的说法中，正确的是（ ）。",[465,467,469,471],{"key":20,"text":466,"correct":26},"挡烟垂壁不能手动开启属于A类不合格，该工程不合格",{"key":24,"text":468,"correct":22},"挡烟垂壁不能手动开启属于B类不合格，该工程不合格",{"key":28,"text":470,"correct":22},"挡烟垂壁不能手动开启属于C类不合格，该工程不合格",{"key":31,"text":472,"correct":22},"信息不全，无法判断",{"id":474,"libraryId":5,"type":69,"typeLabel":70,"stem":475,"options":476,"answer":31,"analysis":37},936328,"对防烟排烟系统进行调试，模拟火灾发生后，火灾自动报警系统应在（ ）内自动关闭相应防烟分区内与排烟无关的通风、空调系统。",[477,479,481,483],{"key":20,"text":478,"correct":22},"3",{"key":24,"text":480,"correct":22},"5",{"key":28,"text":482,"correct":22},"15",{"key":31,"text":418,"correct":26},{"id":485,"libraryId":5,"type":69,"typeLabel":70,"stem":486,"options":487,"answer":28,"analysis":37},936329,"对防烟排烟系统进行周期性检查时，要求排烟窗的温控释放装置、排烟防火阀的易熔片应有（ ）的备用件，且不少于（ ）只。",[488,490,492,494],{"key":20,"text":489,"correct":22},"5％，5",{"key":24,"text":491,"correct":22},"8％，8",{"key":28,"text":493,"correct":26},"10％，10",{"key":31,"text":495,"correct":22},"12％，12",{"id":497,"libraryId":5,"type":69,"typeLabel":70,"stem":498,"options":499,"answer":28,"analysis":37},936330,"防烟排烟系统施工安装前需对风管部件进行现场检查，下列检查项目中，不属于风管部件检查项目的是（ ）。",[500,502,503,505],{"key":20,"text":501,"correct":22},"电动防火阀",{"key":24,"text":88,"correct":22},{"key":28,"text":504,"correct":26},"正压送风机",{"key":31,"text":506,"correct":22},"柔性短管",{"id":508,"libraryId":5,"type":69,"typeLabel":70,"stem":509,"options":510,"answer":31,"analysis":37},936331,"下列关于防烟排烟系统组件平时状态的说法中，正确的是（ ）。",[511,513,515,516],{"key":20,"text":512,"correct":22},"设置在排烟风机入口处总管上的排烟防火阀平时呈关闭状态",{"key":24,"text":514,"correct":22},"前室内的送风口平时呈开启状态",{"key":28,"text":312,"correct":22},{"key":31,"text":517,"correct":26},"排烟阀平时呈关闭状态",{"id":519,"libraryId":5,"type":69,"typeLabel":70,"stem":520,"options":521,"answer":28,"analysis":37},936332,"防排烟系统组件、材料、设备到场后，对其外观、规格型号、基本性能、严密性等进行检查。下列关于防排烟系统风管及风管部件的现场检查结果，不符合规范要求的是（ ）。",[522,524,526,528],{"key":20,"text":523,"correct":22},"风管的材料品种、规格、厚度等应符合设计要求和国家现行标准的规定",{"key":24,"text":525,"correct":22},"有耐火极限要求的风管的本体、框架与固定材料、密封垫料等必须为不燃材料",{"key":28,"text":527,"correct":26},"电动防火阀、送风口和排烟阀（口）的驱动装置，动作应可靠，在额定工作压力下工作正常",{"key":31,"text":529,"correct":22},"防烟排烟系统柔性短管的制作材料必须为不燃材料，不能使用难燃材料制作",{"id":531,"libraryId":5,"type":69,"typeLabel":70,"stem":532,"options":533,"answer":24,"analysis":37},936333,"机械排烟系统安装时，采用金属材质的排烟风管应设置隔热层保护，下列做法中，正确的是（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":22},"采用硅酸铝材料制作的20mm隔热层",{"key":24,"text":537,"correct":26},"采用矿棉材料制作的40mm隔热层",{"key":28,"text":539,"correct":22},"采用岩棉材料制作的35mm隔热层",{"key":31,"text":541,"correct":22},"采用石棉材料制作的35mm隔热层",{"id":543,"libraryId":5,"type":69,"typeLabel":70,"stem":544,"options":545,"answer":20,"analysis":37},936334,"防烟排烟系统的单机调试项目中包括送风机、排烟风机的调试，下列关于风机调试的说法中，错误的是（ ）。",[546,548,550,552],{"key":20,"text":547,"correct":26},"手动开启风机，风机应正常运转1.0h，叶轮旋转方向应正确、运转平稳、无异常振动与声响",{"key":24,"text":549,"correct":22},"测定风机的风量、风压、电流和电压，其结果应与设计相符",{"key":28,"text":551,"correct":22},"在消防控制室手动启动风机，风机的启动状态信号应能反馈到消防控制室",{"key":31,"text":553,"correct":22},"在消防控制室手动停止风机，风机的停止状态信号应能反馈到消防控制室",{"id":555,"libraryId":5,"type":69,"typeLabel":70,"stem":556,"options":557,"answer":28,"analysis":37},936335,"对某公共建筑内的防排烟系统进行安装检查，根据《建筑防烟排烟系统技术标准》GB51251—2017的相关要求，下列关于风管安装要求的做法中，不正确的是（ ）。",[558,560,562,564],{"key":20,"text":559,"correct":22},"金属风管采用法兰连接时，其螺栓孔的间距不得大于150mm",{"key":24,"text":561,"correct":22},"非金属风管采用法兰连接时，其螺栓孔的间距不得大于120mm",{"key":28,"text":563,"correct":26},"金属风管应以板材连接的密封为主，可辅以密封胶嵌缝或其他方法密封，密封面宜设在风管的负压侧",{"key":31,"text":565,"correct":22},"金属排烟风管的隔热层应采用厚度不小于40mm的不燃绝热材料",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":52,"analysis":37},936336,"系统周期性检查是指建筑使用、管理单位按照国家工程消防技术标准的要求，对已经投入使用的防烟排烟系统的组件、零部件等按照规定检查周期进行的检查、测试。下列属于每季检查的项目的是（ ）。",[570,572,574,576,578],{"key":20,"text":571,"correct":26},"对防烟、排烟风机进行手动或自动启动试运转，检查有无锈蚀、螺钉松动",{"key":24,"text":573,"correct":26},"对挡烟垂壁进行手动或自动启动、复位试验，检查有无升降障碍",{"key":28,"text":575,"correct":22},"对防火阀进行手动或自动启动、复位试验，检查有无变形、锈蚀，并检查弹簧性能，确认性能可靠",{"key":31,"text":577,"correct":22},"对送风阀（口）进行手动或自动启动、复位试验，检查有无变形、锈蚀，并检查弹簧性能，确认性能可靠",{"key":34,"text":579,"correct":26},"对排烟窗进行手动或自动启动、复位试验，检查有无开关障碍",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":594,"analysis":37},936337,"现对某建筑内设置的防排烟系统进行检查验收，下列检查结果中符合规范要求的是（ ）。",[584,586,588,590,592],{"key":20,"text":585,"correct":26},"送风机设置在专用机房内，该房间采用耐火极限不低于2．00h的隔墙和1．50h的楼板及甲级防火门与其他部位隔开",{"key":24,"text":587,"correct":26},"送风管道采用镀锌钢板，测量管道风速为15m／s",{"key":28,"text":589,"correct":22},"建筑每层前室设一个常开式加压送风口",{"key":31,"text":591,"correct":22},"排烟管道采用土建风道，测量管道风速为15m／s",{"key":34,"text":593,"correct":22},"测量排烟口至该防烟分区最远点的水平距离为35m","AB",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":609,"analysis":37},936338,"下列厂房或生产部位应设置排烟设施的是（ ）。",[599,601,603,605,607],{"key":20,"text":600,"correct":26},"木器厂内建筑面积大于 300 ㎡且经常有人停留或可燃物较多的地上房间",{"key":24,"text":602,"correct":26},"建筑面积 6000 ㎡的丁类生产车间",{"key":28,"text":604,"correct":26},"建筑高度大于 32m 的服装加工厂房内长度大于 20m 的疏散走道",{"key":31,"text":606,"correct":22},"建筑面积大于 6000 ㎡的电动车库",{"key":34,"text":608,"correct":22},"人员或可燃物较多的乙类生产场所","ABC",{"id":611,"libraryId":5,"type":69,"typeLabel":70,"stem":612,"options":613,"answer":20,"analysis":37},936339,"下列消防应急照明和疏散指示系统施工安装检查中，不正确的是（ ）。",[614,616,618,620],{"key":20,"text":615,"correct":26},"应急照明控制器与消防电源之间可以使用插头连接",{"key":24,"text":617,"correct":22},"带有疏散方向指示箭头的消防应急标志灯具在安装时应保证箭头指示的疏散方向与疏散方向相同",{"key":28,"text":619,"correct":22},"消防应急照明灯具安装时，在正面迎向人员疏散方向，应有防止造成眩光的措施",{"key":31,"text":621,"correct":22},"消防应急灯具宜安装在不燃烧墙体和不燃烧装修材料上",{"id":623,"libraryId":5,"type":69,"typeLabel":70,"stem":624,"options":625,"answer":24,"analysis":37},936340,"对配电线路穿越的孔洞进行防火封堵是防止火灾通过配电线路蔓延的重要措施。下列防火封堵做法不符合要求的是（ ）。",[626,628,630,632],{"key":20,"text":627,"correct":22},"电缆坚井采用矿棉板加膨胀型防火堵料组合成的膨胀型防火封堵系统封堵",{"key":24,"text":629,"correct":26},"电器柜孔防火封堵系统与电缆之间防火密封胶厚度凸出防火封堵系统面10mm",{"key":28,"text":631,"correct":22},"在垂直段竖井封堵处上方使用容重为170k／m3的矿棉板",{"key":31,"text":633,"correct":22},"电缆隧道防火封堵系统两侧电缆采用电缆涂料涂刷",{"id":635,"libraryId":5,"type":69,"typeLabel":70,"stem":636,"options":637,"answer":24,"analysis":37},936341,"对建筑物进行防火检查时，应注意检查建筑物的消防用电负荷的合理性。下列建筑中，消防用电应按一级负荷供电的是（ ）。",[638,640,642,644],{"key":20,"text":639,"correct":22},"每层建筑面积均为3500m2的商店建筑",{"key":24,"text":641,"correct":26},"建筑高度为25m的医院病房楼",{"key":28,"text":643,"correct":22},"建筑高度为45m的办公楼",{"key":31,"text":645,"correct":22},"省（市）级及以上的广播电视中心建筑",[647,650,653,656,659,662],{"id":69,"name":648,"category":7,"favorite":649},"领导干部任职前廉政法规知识测试题",92,{"id":651,"name":652,"category":7,"favorite":69},595,"建筑结构与设备",{"id":654,"name":655,"category":7,"favorite":69},715,"招标采购专业知识与法律法规",{"id":657,"name":658,"category":7,"favorite":69},848,"市政方向-通用基础",{"id":660,"name":661,"category":7,"favorite":8},534,"BIM工程师",{"id":663,"name":661,"category":7,"favorite":8},535]