[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":633},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,32,50,2974,[13,34,46,58,70,82,94,106,124,136,148,160,172,181,193,205,217,227,239,251,260,272,284,299,314,327,342,357,369,383,398,413,428,442,454,466,477,485,497,509,519,531,543,555,563,571,583,595,607,619],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},936239,1,"单选题","某单层宴会厅作为一个灭火器配置单元设置了规格类型完全相同的20具灭火器，在灭火器送修时为避免采取相应的替代措施，则一次送修灭火器的数量最多不应超过（ ）具。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","3",false,{"key":24,"text":25,"correct":22},"B","4",{"key":27,"text":28,"correct":29},"C","5",true,{"key":31,"text":32,"correct":22},"D","6","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},936240,"关于灭火器现场质量检查的说法，不正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"二氧化碳灭火器可不设置压力表，但应设置超压保护装置",{"key":24,"text":41,"correct":29},"MF／ABC2灭火器应配置喷射软管，长度不得小于400mm",{"key":27,"text":43,"correct":22},"手提式灭火器应安装间歇喷射机构",{"key":31,"text":45,"correct":22},"干粉灭火器压力指示器表盘的灭火剂适用标志为F",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},936241,"灭火器维修人员对手提式干粉灭火器进行维修，维修过程中不可更换的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":29},"灭火器的筒体",{"key":24,"text":53,"correct":22},"灭火器的器头",{"key":27,"text":55,"correct":22},"压力指示器",{"key":31,"text":57,"correct":22},"喷射软管",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},936242,"灭火器存在的下列情况中， 要予以报废处理的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"水基型灭火器出厂期满 5 年",{"key":24,"text":65,"correct":29},"干粉灭火器出厂期满 10 年",{"key":27,"text":67,"correct":22},"二氧化碳灭火器出厂期满 11 年",{"key":31,"text":69,"correct":22},"洁净气体灭火器出厂期满 8 年",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},936243,"灭火器 MFT\u002FABC20 代表的含义为（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":29},"20kgABC 干粉推车式灭火器",{"key":24,"text":77,"correct":22},"20kgABC 干粉手提式灭火器",{"key":27,"text":79,"correct":22},"20LABC 干粉推车式灭火器",{"key":31,"text":81,"correct":22},"20LABC 干粉手提式灭火器",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},936244,"建筑灭火器配置验收合格的判定条件是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":29},"A=0，且B≤1，且B+C≤4",{"key":24,"text":89,"correct":22},"A=0，且B≤2，且B+C≤5",{"key":27,"text":91,"correct":22},"A=1，且B≤1，且B+C≤4",{"key":31,"text":93,"correct":22},"A=1，且B≤2，且B+C≤5",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},936245,"水压试验时，二氧化碳灭火器钢瓶的残余变形率不得大于（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"2％",{"key":24,"text":101,"correct":29},"3％",{"key":27,"text":103,"correct":22},"5％",{"key":31,"text":105,"correct":22},"8％",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},936246,2,"多选题","下列有关建筑灭火器配置验收检查结果中，属于严重缺陷项的是（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":29},"灭火器的产品质量不符合国家有关产品标准的要求",{"key":24,"text":115,"correct":22},"灭火器摆放稳固，灭火器的铭牌朝内，灭火器的器头向上",{"key":27,"text":117,"correct":29},"同一灭火器配置单元内的不同类型灭火器，其灭火剂不相容",{"key":31,"text":119,"correct":22},"灭火器箱上锁",{"key":121,"text":122,"correct":29},"E","灭火器的保护距离不符合规定，不能保证配置场所的任一点都在灭火器设置点的保护范围内","ACE",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":24,"analysis":33},936247,"推车式灭火器整体最低位置（轮子除外）与地面之间的间距不应小于（ ）mm。",[128,130,132,134],{"key":20,"text":129,"correct":22},"50",{"key":24,"text":131,"correct":29},"100",{"key":27,"text":133,"correct":22},"150",{"key":31,"text":135,"correct":22},"200",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":27,"analysis":33},936248,"根据《建筑灭火器验收及检查规范》GB 50444-2008的规定，对某建筑灭火器配置验收的结果如下，其中合格的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"A=0，且B=1，且C=6",{"key":24,"text":143,"correct":22},"A=0，且B=0，且C=5",{"key":27,"text":145,"correct":29},"A=0，且B=1，且C=2",{"key":31,"text":147,"correct":22},"A=1，且B=1，且C=1",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":27,"analysis":33},936249,"灭火器进行日常维修时，每次送修的灭火器数量不得超过计算单元配置灭火器总数量的（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":22},"1／2",{"key":24,"text":155,"correct":22},"1／3",{"key":27,"text":157,"correct":29},"1／4",{"key":31,"text":159,"correct":22},"1／5",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":33},936250,"某网吧设有手提式干粉灭火器，应每（ ）对灭火器的配置和外观进行全面检查。",[164,166,168,170],{"key":20,"text":165,"correct":22},"月",{"key":24,"text":167,"correct":29},"半月",{"key":27,"text":169,"correct":22},"周",{"key":31,"text":171,"correct":22},"季度",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":27,"analysis":33},936251,"灭火器挂钩、托架安装后，能够承受（ ）倍的手提式灭火器的静载荷（当总试验荷载小于45kg时，按45kg计），承载5min后，不出现松动、脱落、断裂和明显变形等现象。",[176,178,179,180],{"key":20,"text":177,"correct":22},"2",{"key":24,"text":21,"correct":22},{"key":27,"text":28,"correct":29},{"key":31,"text":32,"correct":22},{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":20,"analysis":33},936252,"生产企业附送的灭火器维修手册，用于指导社会单位、维修企业的灭火器报修、维修工作，下列不属于维修手册主要内容的是（ ）。",[185,187,189,191],{"key":20,"text":186,"correct":29},"灭火器生产企业具备的条件",{"key":24,"text":188,"correct":22},"灭火器易损零部件的名称、数量",{"key":27,"text":190,"correct":22},"关键零部件说明",{"key":31,"text":192,"correct":22},"必要的说明、警告和提示",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":31,"analysis":33},936253,"灭火器出厂时间达到或者超过一定的期限，均予以报废处理。下列关于灭火器报废期限的说法中，正确的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"手提式水基型灭火器出厂满7年",{"key":24,"text":200,"correct":22},"干粉灭火器出厂期满12年",{"key":27,"text":202,"correct":22},"洁净气体灭火器出厂期满12年",{"key":31,"text":204,"correct":29},"二氧化碳灭火器出厂期满12年",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":33},936254,"灭火器箱的正面右下角应设置耐久性铭牌，下列不属于铭牌上的内容的是（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"生产日期",{"key":24,"text":212,"correct":29},"维修标志",{"key":27,"text":214,"correct":22},"型号规格",{"key":31,"text":216,"correct":22},"注册商标",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":27,"analysis":33},936255,"在对灭火器维修和再充装前，应对灭火器进行水压试验，其中二氧化碳灭火器钢瓶的残余变形率不得大于（ ）。",[221,223,224,225],{"key":20,"text":222,"correct":22},"1％",{"key":24,"text":99,"correct":22},{"key":27,"text":101,"correct":29},{"key":31,"text":226,"correct":22},"4％",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":27,"analysis":33},936256,"根据《灭火器维修》CA 95—2015的相关规定，在对灭火器进行维修时，更换的零部件应与原灭火器生产企业提供的零部件的（ ）。",[231,233,235,237],{"key":20,"text":232,"correct":22},"型号保持一致",{"key":24,"text":234,"correct":22},"批次保持一致",{"key":27,"text":236,"correct":29},"特性保持一致",{"key":31,"text":238,"correct":22},"品牌保持一致",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":27,"analysis":33},936257,"根据《灭火器维修》（GA 95），下列零部件和灭火剂中，无须在每次维修灭火器时都更换的是（ ）。",[243,245,247,249],{"key":20,"text":244,"correct":22},"密封垫",{"key":24,"text":246,"correct":22},"二氧化碳灭火器的超压安全膜片",{"key":27,"text":248,"correct":29},"水基型灭火器的滤网",{"key":31,"text":250,"correct":22},"水基型灭火剂",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":33},936258,"某灭火器型号为MF6，正常情况下该灭火器首次维修以后每满（ ）年应进行维修。",[255,257,258,259],{"key":20,"text":256,"correct":22},"1",{"key":24,"text":177,"correct":29},{"key":27,"text":21,"correct":22},{"key":31,"text":28,"correct":22},{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":20,"analysis":33},936259,"某单位拟更换灭火器箱，委托某消防技术服务机构对新购进的单体类灭火器箱进行检查。在进行外观标志检查时，测得“灭火器”中文字体的尺寸如下，其中不合格的是（ ）。",[264,266,268,270],{"key":20,"text":265,"correct":29},"高度58mm，宽度30mm",{"key":24,"text":267,"correct":22},"高度60mm，宽度30mm",{"key":27,"text":269,"correct":22},"高度60mm，宽度32mm",{"key":31,"text":271,"correct":22},"高度62mm，宽度30mm",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":27,"analysis":33},936260,"某地公安消防部门对辖区内一新增企业的4座建筑内的灭火器进行配置验收，结果如下，其中合格的是（ ）。",[276,278,280,282],{"key":20,"text":277,"correct":22},"A=0，B=1，C=4",{"key":24,"text":279,"correct":22},"A=0，B=2，C=2",{"key":27,"text":281,"correct":29},"A=0，B=1，C=2",{"key":31,"text":283,"correct":22},"A=1，B=0，C=1",{"id":285,"libraryId":5,"type":108,"typeLabel":109,"stem":286,"options":287,"answer":298,"analysis":33},936261,"对已列入国家颁布的淘汰目录的灭火器，一经发现均予以报废处理，下列灭火器需做报废处理的是（ ）。",[288,290,292,294,296],{"key":20,"text":289,"correct":29},"化学泡沫型灭火器",{"key":24,"text":291,"correct":29},"倒置使用型灭火器",{"key":27,"text":293,"correct":22},"清水泡沫灭火器",{"key":31,"text":295,"correct":29},"四氯化碳灭火器",{"key":121,"text":297,"correct":29},"1211灭火器","ABDE",{"id":300,"libraryId":5,"type":108,"typeLabel":109,"stem":301,"options":302,"answer":313,"analysis":33},936262,"在对建筑灭火器进行日常检查时，发现如下情况的灭火器，按规定需要送去及时维修的是（ ）。",[303,305,307,309,311],{"key":20,"text":304,"correct":29},"有轻微损伤的灭火器",{"key":24,"text":306,"correct":22},"筒体锈蚀面积大于简体总面积1／3的灭火器",{"key":27,"text":308,"correct":29},"被开启使用过的灭火器",{"key":31,"text":310,"correct":22},"被火烧过的灭火器",{"key":121,"text":312,"correct":22},"筒体明显变形的灭火器","AC",{"id":315,"libraryId":5,"type":108,"typeLabel":109,"stem":316,"options":317,"answer":326,"analysis":33},936264,"灭火器维修机构应按原灭火器生产企业的灭火器装配图样和可更换零部件明细表进行部件更换。下列组件中，每次维修时，应作更换的是（ ）。",[318,319,321,323,325],{"key":20,"text":246,"correct":29},{"key":24,"text":320,"correct":29},"密封片",{"key":27,"text":322,"correct":22},"筒体",{"key":31,"text":324,"correct":22},"虹吸管",{"key":121,"text":244,"correct":29},"ABE",{"id":328,"libraryId":5,"type":108,"typeLabel":109,"stem":329,"options":330,"answer":341,"analysis":33},936265,"某网吧建筑面积为500m2，设置在某建筑的第三层，在对该网吧进行检查时，发现下列情况，其中符合相应规范要求的有（ ）。",[331,333,335,337,339],{"key":20,"text":332,"correct":22},"网吧内设置了类型规格为MF／ABC4灭火器",{"key":24,"text":334,"correct":22},"设置在挂钩上的灭火器，底部与地面之间的距离为0．05m",{"key":27,"text":336,"correct":22},"从灭火器的检查记录表上发现外观检查每月进行一次",{"key":31,"text":338,"correct":29},"翻盖型灭火器箱的翻盖开启角度为105°。",{"key":121,"text":340,"correct":29},"灭火器箱的箱体正面设置了指示灭火器位置的发光标志","DE",{"id":343,"libraryId":5,"type":108,"typeLabel":109,"stem":344,"options":345,"answer":356,"analysis":33},936266,"在对某大型商业综合体内配置的灭火器进行验收时发现以下缺陷项，其中属于重缺陷项的是（ ）。",[346,348,350,352,354],{"key":20,"text":347,"correct":22},"地下一层超市配置了规格型号为MF／ABC2灭火器",{"key":24,"text":349,"correct":29},"部分灭火器箱被上锁",{"key":27,"text":351,"correct":22},"五层电影院区域灭火器设置数量不足",{"key":31,"text":353,"correct":29},"有视线障碍的设置点，未设置指示灭火器位置的发光标志",{"key":121,"text":355,"correct":22},"地下配电室内设置在托架上的灭火器距地高度1．6m","BD",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":31,"analysis":33},936267,"对灭火器箱体结构及箱门开启性能实施检查，箱门开启操作，翻盖型箱门的开启角度不得小于（）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"155°",{"key":24,"text":364,"correct":22},"165°",{"key":27,"text":366,"correct":22},"170°",{"key":31,"text":368,"correct":29},"100°",{"id":370,"libraryId":5,"type":108,"typeLabel":109,"stem":371,"options":372,"answer":382,"analysis":33},936268,"下列灭火器予以报废处理的是（）。",[373,374,376,378,380],{"key":20,"text":204,"correct":29},{"key":24,"text":375,"correct":22},"筒体锈蚀",{"key":27,"text":377,"correct":29},"筒体明显变形，机械损伤严重的",{"key":31,"text":379,"correct":29},"没有生产厂名称和出厂年月的",{"key":121,"text":381,"correct":29},"被火烧过的","ACDE",{"id":384,"libraryId":5,"type":108,"typeLabel":109,"stem":385,"options":386,"answer":397,"analysis":33},936269,"灭火器报废分为（）。",[387,389,391,393,395],{"key":20,"text":388,"correct":29},"列入国家颁布的淘汰目录的灭火器",{"key":24,"text":390,"correct":29},"达到报废年限的灭火器",{"key":27,"text":392,"correct":29},"使用中出现严重损伤或者重大缺陷的灭火器",{"key":31,"text":394,"correct":29},"维修时发现存在严重损伤、缺陷的灭火器",{"key":121,"text":396,"correct":22},"缺少标识的灭火器","ABCD",{"id":399,"libraryId":5,"type":108,"typeLabel":109,"stem":400,"options":401,"answer":412,"analysis":33},936270,"对某建筑面积为3000 m2的图书馆，设置手提式干粉灭火器进行竣工验收时的检查记录如下，其中符合规范要求的是（ ）。",[402,404,406,408,410],{"key":20,"text":403,"correct":29},"测量灭火器箱底部与地面的距离为0．1m",{"key":24,"text":405,"correct":29},"两个灭火器配置点的最远距离为20m",{"key":27,"text":407,"correct":22},"每个灭火器配置点设置3具MF／ABC4的灭火器",{"key":31,"text":409,"correct":29},"灭火器箱正面的零部件凸出箱门外表面高度10mm",{"key":121,"text":411,"correct":22},"用直尺测量灭火器箱的表面字体尺寸为30mm×50mm（宽X高）","ABD",{"id":414,"libraryId":5,"type":108,"typeLabel":109,"stem":415,"options":416,"answer":427,"analysis":33},936271,"灭火器日常检查中，发现灭火器达到报废条件时要及时报废处理。在灭火器检查中发现如下情况，应及时报废的有（ ）。",[417,419,421,423,425],{"key":20,"text":418,"correct":29},"酸碱型灭火器",{"key":24,"text":420,"correct":22},"MS／AR3灭火器出厂期满5年",{"key":27,"text":422,"correct":29},"MF／ABC3灭火器出厂期满12年",{"key":31,"text":424,"correct":29},"铭牌脱落的灭火器",{"key":121,"text":426,"correct":22},"筒体锈蚀面积为筒体总面积的1／5","ACD",{"id":429,"libraryId":5,"type":108,"typeLabel":109,"stem":430,"options":431,"answer":412,"analysis":33},936272,"某办公楼物业公司对建筑内配置的灭火器进行检查时发现如下情况，应进行送修处理的有（ ）。",[432,434,436,438,440],{"key":20,"text":433,"correct":29},"楼道内压力表指针指向红区的干粉灭火器",{"key":24,"text":435,"correct":29},"电子计算机房内出厂期刚满7年的二氧化碳灭火器",{"key":27,"text":437,"correct":22},"筒体严重变形的灭火器",{"key":31,"text":439,"correct":29},"开启使用过的灭火器",{"key":121,"text":441,"correct":22},"楼道内出厂期刚满4年的干粉灭火器",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":27,"analysis":33},936273,"下列关于灭火器进场检查的说法，错误的是（ ）。",[446,448,450,452],{"key":20,"text":447,"correct":22},"灭火器的铭牌、生产日期和维修日期等标志应齐全",{"key":24,"text":449,"correct":22},"灭火器筒体应无明显缺陷和机械损伤",{"key":27,"text":451,"correct":29},"灭火器压力指示器的指针应在黄区范围内",{"key":31,"text":453,"correct":22},"灭火器的保险装置应完好",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":27,"analysis":33},936274,"灭火器箱进场应进行检查，下列不属于灭火器箱进场检查内容的是（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":22},"出厂合格证",{"key":24,"text":461,"correct":22},"型式检验报告",{"key":27,"text":463,"correct":29},"材料质地",{"key":31,"text":465,"correct":22},"外观",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":27,"analysis":33},936275,"某场所新到一批型号为MF／ABC4的灭火器，在对其进行现场结构检查时，该灭火器喷射软管的长度不得小于（ ）mm。",[470,471,473,475],{"key":20,"text":135,"correct":22},{"key":24,"text":472,"correct":22},"300",{"key":27,"text":474,"correct":29},"400",{"key":31,"text":476,"correct":22},"500",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":31,"analysis":33},936276,"根据规定，推车式干粉灭火器出厂满（ ）年，应进行维修。",[481,482,483,484],{"key":20,"text":177,"correct":22},{"key":24,"text":21,"correct":22},{"key":27,"text":25,"correct":22},{"key":31,"text":28,"correct":29},{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},936277,"手提式二氧化碳灭火器在结构上与其他手提式灭火器相比，不同在于（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"取消了安全阀，增加了压力表",{"key":24,"text":492,"correct":29},"取消了压力表，增加了安全阀",{"key":27,"text":494,"correct":22},"取消了压力表，增加了泄压阀",{"key":31,"text":496,"correct":22},"取消了安全阀，增加了泄压阀",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":20,"analysis":33},936278,"在同一灭火器配置单元内配置不同类型灭火器时，应选用（ ）的灭火剂。",[501,503,505,507],{"key":20,"text":502,"correct":29},"能相容",{"key":24,"text":504,"correct":22},"不相容",{"key":27,"text":506,"correct":22},"质量相同",{"key":31,"text":508,"correct":22},"体积相同",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":24,"analysis":33},936279,"水基型灭火器出厂期满（ ）年，均予以报废处理。",[513,514,515,517],{"key":20,"text":28,"correct":22},{"key":24,"text":32,"correct":29},{"key":27,"text":516,"correct":22},"10",{"key":31,"text":518,"correct":22},"12",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},936280,"消防安全检查中，灭火器出厂期满3年需要进行维修的是（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":22},"推车式干粉灭火器",{"key":24,"text":526,"correct":29},"推车式水基型灭火器",{"key":27,"text":528,"correct":22},"洁净气体灭火器",{"key":31,"text":530,"correct":22},"二氧化碳灭火器",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":20,"analysis":33},936281,"某学校宿舍长度为40 m，宽度为13 m，建筑层数6层，建筑高度21 m，设有室内消火栓系统。宿舍楼每层设置15间宿舍，每间宿舍学生人数为4人。每层中间沿长度方向设2 m宽的走道。该楼每层灭火器布置做法中，符合《建筑灭火器配置设计规范》（GB50140）要求的是（ ）。",[535,537,539,541],{"key":20,"text":536,"correct":29},"从距走道端部5 m处开始每10 m布置1具MF／ABC5灭火器",{"key":24,"text":538,"correct":22},"在走道尽端各5 m处分别布置2具MF／ABC4灭火器",{"key":27,"text":540,"correct":22},"在走道尽端各5 m处分别布置2具MF／ABC5灭火器",{"key":31,"text":542,"correct":22},"从距走道端部5 m处开始每隔10 m布置1具MS／Q6灭火器",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":27,"analysis":33},936282,"在对某写字楼建筑灭火器进行配置验收时，应核查灭火器的类型、规格、灭火级别和配置数量是否符合建筑灭火器配置设计要求，按照灭火器配置单元的总数，随机抽查（ ），并不得少于（ ）个。",[547,549,551,553],{"key":20,"text":548,"correct":22},"10％，3",{"key":24,"text":550,"correct":22},"10％，5",{"key":27,"text":552,"correct":29},"20％，3",{"key":31,"text":554,"correct":22},"20％，5",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":20,"analysis":33},936283,"某单位配置了一批型号为MSQ6的灭火器，配置之后一直都未被启用过。根据规范要求，该批灭火器出厂时间满（ ）年后应进行维修。",[559,560,561,562],{"key":20,"text":21,"correct":29},{"key":24,"text":28,"correct":22},{"key":27,"text":32,"correct":22},{"key":31,"text":516,"correct":22},{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":24,"analysis":33},936284,"某场所配置的手提式二氧化碳灭火器出厂时间为2013年9月，于2018年9月进行了首次维修，则灭火器在达到报废年限之前至少还应进行（ ）次维修。",[567,568,569,570],{"key":20,"text":177,"correct":22},{"key":24,"text":21,"correct":29},{"key":27,"text":25,"correct":22},{"key":31,"text":28,"correct":22},{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":24,"analysis":33},936285,"某单独建造的3层歌舞厅建筑，建筑高度15m，长宽为52×13m，在每层居中部位沿建筑长度方向设3m宽的内走道，该建筑按国家消防技术标准设置了消防设施。每层为一个灭火器配置单元，则关于该建筑每层灭火器配置的做法，错误的是（ ）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"选用规格型号为MF／ABC5的灭火器",{"key":24,"text":578,"correct":29},"距走道尽端各10m处设置2个手提式灭火器配置点",{"key":27,"text":580,"correct":22},"每层配置的灭火器灭火级别为9A",{"key":31,"text":582,"correct":22},"灭火器挂墙设置，器头距地高1．5m",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":27,"analysis":33},936286,"维保单位对以下场所的灭火器进行检查，下列做法正确的是（ ）：",[587,589,591,593],{"key":20,"text":588,"correct":22},"对某电影院每个月检查一次",{"key":24,"text":590,"correct":22},"对某住宅建筑内的地下室每月检查一次",{"key":27,"text":592,"correct":29},"对某歌舞厅每半月检查一次",{"key":31,"text":594,"correct":22},"对某住宅建筑建筑内的锅炉房每月检查一次",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":24,"analysis":33},936287,"按照相关消防设计规范要求对建筑物进行灭火器配置验收， 项目缺陷划分为严重缺陷项 （A）、 重缺陷项 （B） 和轻缺陷项 （C）。 下列灭火器配置验收合格的是（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"A=0， B=l， C=4",{"key":24,"text":602,"correct":29},"A=0， B=1， C=3",{"key":27,"text":604,"correct":22},"A=0， B=2， C=2",{"key":31,"text":606,"correct":22},"A=0， B=2， C=3",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":31,"analysis":33},936288,"灭火器挂钩、托架安装后，应能够承受（ ）的手提式灭火器（当5倍的手提式灭火器质量小于45kg时，按45kg计）的静载荷，承载5min后，不出现松动、脱落、断裂和明显变形等现象。",[611,613,615,617],{"key":20,"text":612,"correct":22},"2倍",{"key":24,"text":614,"correct":22},"3倍",{"key":27,"text":616,"correct":22},"4倍",{"key":31,"text":618,"correct":29},"5倍",{"id":620,"libraryId":5,"type":108,"typeLabel":109,"stem":621,"options":622,"answer":123,"analysis":33},936289,"消防技术服务机构对某建筑内设置的灭火器进行检查，检查结果如下，其中不符合现行国家消防技术标准的是（ ）。",[623,625,627,629,631],{"key":20,"text":624,"correct":29},"灭火器配置点的温度大于灭火器使用温度",{"key":24,"text":626,"correct":22},"嵌墙式灭火器箱的安装高度为1．6m，箱内手提式灭火器顶部距地面的高度为1．4m",{"key":27,"text":628,"correct":29},"同一场所内配置了BC类干粉灭火器和ABC类灭火器",{"key":31,"text":630,"correct":22},"A类严重危险等级场所设置了单具最小灭火级别为4A的灭火器",{"key":121,"text":632,"correct":29},"灭火器配置场所内无法保证任何一点都在灭火器的保护范围之内",[634,637,640,643,646,649],{"id":15,"name":635,"category":7,"favorite":636},"领导干部任职前廉政法规知识测试题",92,{"id":638,"name":639,"category":7,"favorite":15},595,"建筑结构与设备",{"id":641,"name":642,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":644,"name":645,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":647,"name":648,"category":7,"favorite":8},534,"BIM工程师",{"id":650,"name":648,"category":7,"favorite":8},535]