[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":648},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,30,50,2974,[13,34,46,58,70,82,94,106,118,136,151,166,181,196,208,219,231,243,255,267,279,291,303,318,333,345,357,366,378,390,402,413,425,437,449,461,472,487,502,517,529,541,552,564,576,588,600,612,624,636],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},936138,1,"单选题","某施工单位安装二氧化碳灭火系统时，采用防晃支架对系统管道固定，按照规定，支架与末端喷嘴间的距离不应大于（ ）mm。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","300",false,{"key":24,"text":25,"correct":22},"B","400",{"key":27,"text":28,"correct":29},"C","500",true,{"key":31,"text":32,"correct":22},"D","600","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},936139,"气体灭火系统灭火剂输送管道的外表面宜涂红色油漆。吊顶内、活动地板下等隐蔽场所内的管道，可涂红色油漆色环，色环宽度不应小于（ ）mm。每个防护区或保护对象的色环宽度要一致，间距应均匀。",[38,40,42,44],{"key":20,"text":39,"correct":22},"15",{"key":24,"text":41,"correct":22},"30",{"key":27,"text":43,"correct":29},"50",{"key":31,"text":45,"correct":22},"100",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},936140,"消防服务机构对某单位的电子信息机房设置的无管网七氟丙烷气体灭火系统进行检测，检测结果如下，其中不符合现行国家消防技术标准要求的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"防护区内设置8台预制灭火装置",{"key":24,"text":53,"correct":29},"储存容器的充装压力为2．8MPa",{"key":27,"text":55,"correct":22},"系统仅设置自动控制、手动控制两种启动方式",{"key":31,"text":57,"correct":22},"启动时动作响应时差为2s",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},936141,"某电信大楼中的计算机主机房、通讯设备间内设置了组合分配式七氟丙烷气体灭火系统。下列关于该系统设计的说法中，错误的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"同一集流管上的储存容器，其规格、充压压力和充装量应相同",{"key":24,"text":65,"correct":29},"同一防护区，当设计两套及以上管网时，系统启动装置可以分别设置，但集流管必须共用",{"key":27,"text":67,"correct":22},"管网上不应采用四通管件进行分流",{"key":31,"text":69,"correct":22},"喷头宜贴近防护区顶面安装，距顶面的最大距离不宜大于0.5m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},936142,"气动驱动装置的管道安装后,要进行气压严密性试验。在试验时,下列操作方法错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"逐步缓慢增加压力至试验压力的 50%时,观察是否出现异状或泄漏",{"key":24,"text":77,"correct":29},"试验压力的 50%无泄漏,继续按试验压力的 5%逐级升压,至试验压力值",{"key":27,"text":79,"correct":22},"每级升压后,应稳压 3min,观察是否出现异状或泄漏",{"key":31,"text":81,"correct":22},"试验过程中管道各处无变形,无泄漏则为合格",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},936143,"关于气体灭火系统中的组件安装,以下说法不正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"启动驱动管道水平段上每隔 0.6m 应设置管卡,转弯处增设管卡",{"key":24,"text":89,"correct":29},"重力式驱动装置下落行程不应小于 20mm",{"key":27,"text":91,"correct":22},"管道末端于喷嘴的距离不应大于 0.5m",{"key":31,"text":93,"correct":22},"选择阀操作手柄距地高度超过 1.7m 时,应采取便于操作的措施",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},936144,"关于气体灭火系统组件安装前的检查,说法错误的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":29},"气动驱动装置储存容器内气体压力不应大于设计压力的 6%",{"key":24,"text":101,"correct":22},"机械驱动装置应转动灵活、无卡阻",{"key":27,"text":103,"correct":22},"灭火剂储瓶高差不应超过 20mm",{"key":31,"text":105,"correct":22},"驱动气瓶高差不应超过 10mm",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},936145,"气体灭火剂输送管道已防腐处理的无缝钢管不宜采用（ ）连接。",[110,112,114,116],{"key":20,"text":111,"correct":22},"螺纹",{"key":24,"text":113,"correct":29},"焊接",{"key":27,"text":115,"correct":22},"法兰",{"key":31,"text":117,"correct":22},"承插",{"id":119,"libraryId":5,"type":120,"typeLabel":121,"stem":122,"options":123,"answer":135,"analysis":33},936146,2,"多选题","下列关于气体灭火系统模拟喷气试验的说法中，正确的是（ ）。",[124,126,128,130,132],{"key":20,"text":125,"correct":29},"IG541混合气体灭火系统试验采用的储存容器数应为选定试验的防护区或保护对象设计用量所需容器总数的5％，且不少于1个",{"key":24,"text":127,"correct":22},"高压二氧化碳灭火系统试验采用的储存容器数应为选定试验的防护区或保护对象设计用量所需容器总数的10％，且不少于1个",{"key":27,"text":129,"correct":22},"卤代烷灭火系统模拟喷气试验宜采用卤代烷灭火剂、氮气或压缩空气进行",{"key":31,"text":131,"correct":29},"低压二氧化碳灭火系统采用二氧化碳灭火剂进行模拟喷气试验，试验要选定输送管道最长的防护区或保护对象进行，喷放量不小于设计用量的10％",{"key":133,"text":134,"correct":29},"E","卤代烷灭火系统模拟喷气试验为氮气时，氮气储存容器数不应少于灭火剂储存容器数的20％，且不少于1个","ADE",{"id":137,"libraryId":5,"type":120,"typeLabel":121,"stem":138,"options":139,"answer":150,"analysis":33},936147,"某消防检测机构对气体灭火系统进行模拟喷气试验，试验结果如下，其中符合规定要求的是（ ）。",[140,142,144,146,148],{"key":20,"text":141,"correct":22},"延迟时间大于设计时间",{"key":24,"text":143,"correct":29},"有关控制阀门工作正常",{"key":27,"text":145,"correct":29},"储存容器间内的设备和对应防护区或保护对象的灭火剂输送管道无明显晃动和机械性损坏",{"key":31,"text":147,"correct":22},"信号反馈装置动作后气体防护区门外的气体喷放指示灯未亮",{"key":133,"text":149,"correct":29},"有关声、光报警信号正确","BCE",{"id":152,"libraryId":5,"type":120,"typeLabel":121,"stem":153,"options":154,"answer":165,"analysis":33},936148,"我国常用的气体灭火系统包括（ ）。",[155,157,159,161,163],{"key":20,"text":156,"correct":29},"二氧化碳灭火系统",{"key":24,"text":158,"correct":22},"氮气灭火系统",{"key":27,"text":160,"correct":29},"七氟丙烷灭火系统",{"key":31,"text":162,"correct":29},"IG541灭火系统",{"key":133,"text":164,"correct":29},"热气溶胶预制灭火系统","ACDE",{"id":167,"libraryId":5,"type":120,"typeLabel":121,"stem":168,"options":169,"answer":180,"analysis":33},936149,"某学校电子计算机房共十个防护区，层高为4．5m，其中有两个防护区有地板层，地板层高度为300mm，采用组合分配式七氟丙烷气体灭火系统，下列检查结果，不符合规范要求的是（ ）。",[170,172,174,176,178],{"key":20,"text":171,"correct":29},"共设置两套组合分配系统，集流管分别设置，其中一个集流管上的所用90L钢瓶10组，120L钢瓶2组",{"key":24,"text":173,"correct":29},"地板下设置喷头的保护半径为5m",{"key":27,"text":175,"correct":22},"防护区的泄压口高度均在距地3．5m处",{"key":31,"text":177,"correct":29},"灭火剂输送DN25管道的管道支架间距为2．5m",{"key":133,"text":179,"correct":29},"防护区入口处的手自动转换开关，安装高度距地1．7m","ABDE",{"id":182,"libraryId":5,"type":120,"typeLabel":121,"stem":183,"options":184,"answer":195,"analysis":33},936150,"采用气体灭火系统灭火后的防护区应通风换气，下列关于通风换气的相关设置或设施的说法符合规定的有（ ）",[185,187,189,191,193],{"key":20,"text":186,"correct":29},"地下防护区和无窗的地上防护区应设置机械排风装置",{"key":24,"text":188,"correct":29},"电子计算机房的通风换气次数应不小于每小时5次",{"key":27,"text":190,"correct":22},"排风口宜设在防护区的上部并应直通室外",{"key":31,"text":192,"correct":22},"通信机房的通风换气次数应不小于每小时4次",{"key":133,"text":194,"correct":22},"设固定窗扇的地上防护区可不设机械排风装置","AB",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":20,"analysis":33},936151,"泡沫混合液立管上设置的控制阀，其安装高度一般在（ ）m之间，并需要设置明显的启闭标志；当控制阀的安装高度大于1．8m时，需要设置操作平台或操作凳。",[200,202,204,206],{"key":20,"text":201,"correct":29},"1．1～1．5",{"key":24,"text":203,"correct":22},"1．1～1．6",{"key":27,"text":205,"correct":22},"1．2～1．5",{"key":31,"text":207,"correct":22},"1．2～1．8",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},936152,"低倍数泡沫系统进行喷泡沫试验时，喷射泡沫的时间不宜小于（ ）s。",[212,213,215,217],{"key":20,"text":41,"correct":22},{"key":24,"text":214,"correct":29},"60",{"key":27,"text":216,"correct":22},"90",{"key":31,"text":218,"correct":22},"120",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":24,"analysis":33},936153,"某施工单位承接了一项泡沫灭火系统的安装工程，下列关于泡沫灭火系统管网安装及冲洗、试压的说法中，错误的是（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":22},"水平管道安装时要注意留有管道坡度，在防火堤内要以3‰的坡度坡向防火堤",{"key":24,"text":226,"correct":29},"管道穿过防火堤时要需要安装套管，套管的长度应大于防火堤厚度50mm",{"key":27,"text":228,"correct":22},"立管要用管卡固定在支架上，管卡间距不能大于3m",{"key":31,"text":230,"correct":22},"半固定式系统的泡沫管道，在防火堤外设置的高背压泡沫产生器快装接口要水平安装",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":33},936154,"泡沫灭火系统的阀门应采用清水进行强度和严密性试验，其中下列试验压力的选取符合规范要求的是（ ）。",[235,237,239,241],{"key":20,"text":236,"correct":22},"强度试验压力为公称压力的1．1倍；严密性试验压力为公称压力的1．5倍",{"key":24,"text":238,"correct":29},"强度试验压力为公称压力的1．5倍；严密性试验压力为公称压力的1．1倍",{"key":27,"text":240,"correct":22},"强度试验压力为公称压力的1．1倍；严密性试验压力为公称压力的1．1倍",{"key":31,"text":242,"correct":22},"强度试验压力为公称压力的1．5倍；严密性试验压力为公称压力的1．5倍",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":33},936155,"某中型石油库的外浮顶储罐设置了低倍数泡沫灭火系统，采用液上喷射方式，消防设施检测机构对该系统进行检测，下列检测结果中，不符合现行国家消防技术标准规定的是（ ）。",[247,249,251,253],{"key":20,"text":248,"correct":22},"泡沫混合液供给强度为15L／（min·m2）",{"key":24,"text":250,"correct":29},"泡沫混合液的连续供给时间为25min",{"key":27,"text":252,"correct":22},"泡沫混合液的发泡倍数为8",{"key":31,"text":254,"correct":22},"该系统采用成膜氟蛋白泡沫液",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":27,"analysis":33},936156,"泡沫一水喷雾联用系统，在火灾发生时（ ）。",[259,261,263,265],{"key":20,"text":260,"correct":22},"先喷水雾再喷泡沫",{"key":24,"text":262,"correct":22},"先喷水雾再喷泡沫最后喷水雾",{"key":27,"text":264,"correct":29},"先喷泡沫再喷水雾",{"key":31,"text":266,"correct":22},"先喷泡沫再喷水雾最后喷泡沫",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":24,"analysis":33},936157,"某油罐设置了中倍数泡沫灭火系统,采用 6%蛋白型中倍数泡沫液。下列情况中应将泡沫液送至具备相应资质的检测单位进行检测的是（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":22},"泡沫液最小储备量 2.0t",{"key":24,"text":274,"correct":29},"泡沫液最小储备量 2.5t",{"key":27,"text":276,"correct":22},"泡沫液设计用量 2.5t",{"key":31,"text":278,"correct":22},"泡沫液设计用量 3.5t",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":31,"analysis":33},936158,"泡沫液储罐主要是用来储存泡沫灭大系统中的各种类型的泡沫液,对此安装需要符合一定的要求,下列关于泡沫液储罐的说法不正确的是（ ）。",[283,285,287,289],{"key":20,"text":284,"correct":22},"安装泡沫液储罐的时候,要考虑为日后操作、更换和维修泡沫液储罐等提供便利,泡沫液储罐周围要留有满足检修需要的通道,其宽度不能小于 0.7m 且操作面不能小于 1.5m",{"key":24,"text":286,"correct":22},"现场制作的常压钢质泡沫液储罐需要进行严密性试验,试验压力为储罐装满水后的静压力,试验时间不能小于 30min",{"key":27,"text":288,"correct":22},"现场制作的常压钢质泡沫液储罐,泡沫液管道出液口不应高于泡沫液储罐最低液面 1m",{"key":31,"text":290,"correct":29},"泡沫液管道吸液口距泡沫液储罐底面不小于 0.3m 且宜做成喇叭形",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":20,"analysis":33},936159,"（ ）泡沫比例混合器适用于建有独立泡沫消防泵站的场所,尤其适用于储罐规格较单一的甲、乙、丙类液体储罐区。",[295,297,299,301],{"key":20,"text":296,"correct":29},"环泵式",{"key":24,"text":298,"correct":22},"压力式",{"key":27,"text":300,"correct":22},"平衡式",{"key":31,"text":302,"correct":22},"管线式",{"id":304,"libraryId":5,"type":120,"typeLabel":121,"stem":305,"options":306,"answer":317,"analysis":33},936160,"某消防检测技术服务人员在对某储罐区泡沫灭火系统进行调试时，发现泡沫产生器无法发泡，下列关于无法发泡原因的分析，正确的是（ ）。",[307,309,311,313,315],{"key":20,"text":308,"correct":29},"泡沫产生器损坏",{"key":24,"text":310,"correct":29},"泡沫液失效",{"key":27,"text":312,"correct":29},"泡沫产生器吸气口被异物堵塞",{"key":31,"text":314,"correct":22},"高位消防水箱压力不足",{"key":133,"text":316,"correct":22},"消防水池的容积过大","ABC",{"id":319,"libraryId":5,"type":120,"typeLabel":121,"stem":320,"options":321,"answer":332,"analysis":33},936161,"某化工企业的立式固定顶乙醇储罐采用低倍数泡沫灭火系统，某消防设施检测机构对该系统进行检查和检测，下列检测结果中，不符合现行国家消防技术标准要求的是（ ）。",[322,324,326,328,330],{"key":20,"text":323,"correct":29},"泡沫混合液供给强度为6L／（min·m2）",{"key":24,"text":325,"correct":29},"泡沫泵启动后6min泡沫产生器喷出泡沫",{"key":27,"text":327,"correct":22},"连续供给时间为28min",{"key":31,"text":329,"correct":29},"泡沫液选用成膜氟蛋白泡沫液",{"key":133,"text":331,"correct":22},"采用半液下喷射方式","ABD",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":31,"analysis":33},936162,"下列关于泡沫灭火系统管道、阀门安装的说法，正确的是（ ）。",[337,339,341,343],{"key":20,"text":338,"correct":22},"埋地管道采用焊接时，焊缝部位应在防腐处理后进行试压",{"key":24,"text":340,"correct":22},"泡沫混合液管道上连接泡沫产生装置的控制阀应安装在防火堤内",{"key":27,"text":342,"correct":22},"泡沫混合液管道上设置的自动排气阀应在系统试压、冲洗合格后水平安装",{"key":31,"text":344,"correct":29},"管道安装检测数量，应干管抽查1条、支管抽查2条、分支管抽查10％，且不得少于1条",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":20,"analysis":33},936163,"根据《泡沫灭火系统施工及验收规范》GB 50281—2006规定，在系统调试时，泡沫灭火系统的动力源和备用动力应进行切换试验，动力源和备用动力及电气设备运行应正常，当为自动控制方式时，最少应进行（ ）次试验。",[349,351,353,355],{"key":20,"text":350,"correct":29},"2",{"key":24,"text":352,"correct":22},"3",{"key":27,"text":354,"correct":22},"4",{"key":31,"text":356,"correct":22},"5",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},936164,"现场制作的常压钢质泡沫液储罐需要进行严密性试验，试验压力为储罐装满水后的静压力，试验时间不应小于（ ）min。",[361,363,364,365],{"key":20,"text":362,"correct":22},"10",{"key":24,"text":41,"correct":29},{"key":27,"text":214,"correct":22},{"key":31,"text":218,"correct":22},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":24,"analysis":33},936165,"泡沫灭火系统应定期实施系统检查和试验，下列属于月度检查测试内容的是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"储罐上低倍数泡沫混合液立管冲洗",{"key":24,"text":373,"correct":29},"泡沫液储罐进行外观检查",{"key":27,"text":375,"correct":22},"消防泵和备用动力启动测试",{"key":31,"text":377,"correct":22},"喷泡沫试验",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":20,"analysis":33},936166,"常压泡沫液储罐的安装过程中，不符合要求的做法是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":29},"现场制作的常压钢质泡沫液储罐，泡沫液管道出液口高于泡沫液储罐最低液面1．20m",{"key":24,"text":385,"correct":22},"泡沫液管道吸液口为喇叭形，距泡沫液储罐底面0．20 m",{"key":27,"text":387,"correct":22},"现场制作的常压钢质泡沫液储罐需要进行严密性试验，试验压力为储罐装满水后的静压力，试验时间为40min",{"key":31,"text":389,"correct":22},"现场制作的常压钢质泡沫液储罐内、外表面需要按设计要求进行防腐处理",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},936167,"泡沫比例混合器调试时，其混合比应符合设计要求，下列关于泡沫混合液的混合比测量方法中，错误的是（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":29},"氟蛋白泡沫液采用手持导电度测量仪测量",{"key":24,"text":397,"correct":22},"抗溶水成膜泡沫液采用手持导电度测量仪测量",{"key":27,"text":399,"correct":22},"折射指数高的泡沫液采用手持折射仪测量",{"key":31,"text":401,"correct":22},"蛋白泡沫液采用手持折射仪测量",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":33},936168,"现场制作的常压钢质泡沫液储罐，泡沫液管道出液口不应高于泡沫液储罐最低液面（ ）m。",[406,408,410,412],{"key":20,"text":407,"correct":22},"0．5",{"key":24,"text":409,"correct":29},"1",{"key":27,"text":411,"correct":22},"1．5",{"key":31,"text":350,"correct":22},{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":27,"analysis":33},936169,"下列关于低倍数泡沫产生器安装的说法，正确的是（ ）。",[417,419,421,423],{"key":20,"text":418,"correct":22},"液下喷射的高背压泡沫产生器应水平安装在防火堤内的泡沫混合液管道上",{"key":24,"text":420,"correct":22},"半液下喷射的高背压泡沫产生器应竖直安装在防火堤外的泡沫混合液管道上",{"key":27,"text":422,"correct":29},"液上喷射泡沫产生器沿罐周均匀布置时，其间距偏差不宜大于100mm",{"key":31,"text":424,"correct":22},"液上喷射的泡沫产生器安装后检查，数量应按安装总数的20％抽查，且不得少于1个",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":27,"analysis":33},936170,"一般情况下，泡沫液进场后，需要现场取样留存，以待日后需要时送检。下述内容中，不属于送检泡沫液需要检测的是（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":22},"发泡倍数",{"key":24,"text":432,"correct":22},"析液时间",{"key":27,"text":434,"correct":29},"浸渍时间",{"key":31,"text":436,"correct":22},"抗烧时间",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":27,"analysis":33},936171,"某罐区安装的泡沫灭火系统使用管线式比例混合器，施工安装时应使其吸液口与泡沫液储罐或泡沫液桶最低液面的高度不大于（ ）m。",[441,443,445,447],{"key":20,"text":442,"correct":22},"0.5",{"key":24,"text":444,"correct":22},"0.8",{"key":27,"text":446,"correct":29},"1.0",{"key":31,"text":448,"correct":22},"1.5",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":33},936172,"泡沫比例混合器调试时,应与系统喷泡沫试验同时进行,对于（ ）泡沫液,可用手持导电度测量仪测量混合比",[453,455,457,459],{"key":20,"text":454,"correct":29},"抗溶水成膜",{"key":24,"text":456,"correct":22},"蛋白",{"key":27,"text":458,"correct":22},"氟蛋白",{"key":31,"text":460,"correct":22},"折射指数高的泡沫液",{"id":462,"libraryId":5,"type":120,"typeLabel":121,"stem":463,"options":464,"answer":165,"analysis":33},936173,"对于需要送检的泡沫液，按现行国家标准《泡沫灭火剂》GB 15308的规定对相关参数进行检测，下列属于检测内容的是（ ）。",[465,466,468,470,471],{"key":20,"text":430,"correct":29},{"key":24,"text":467,"correct":22},"喷射时间",{"key":27,"text":469,"correct":29},"灭火时间",{"key":31,"text":432,"correct":29},{"key":133,"text":436,"correct":29},{"id":473,"libraryId":5,"type":120,"typeLabel":121,"stem":474,"options":475,"answer":486,"analysis":33},936174,"泡沫液是泡沫灭火系统的关键材料，直接影响系统的灭火效果，泡沫液用量较多的情况，需要将其送至具备相应资质的检测单位进行检测。下列情形中需要送检的是（ ）。",[476,478,480,482,484],{"key":20,"text":477,"correct":22},"6％型低倍数泡沫液设计用量6.0t",{"key":24,"text":479,"correct":29},"3％型低倍数泡沫液设计用量为4.0t",{"key":27,"text":481,"correct":29},"6％合成型中倍数泡沫液最小储备量为2t",{"key":31,"text":483,"correct":29},"6％蛋白型中倍数泡沫液最小储备量为3t",{"key":133,"text":485,"correct":22},"6％型低倍数泡沫液设计用量5.0t","BCD",{"id":488,"libraryId":5,"type":120,"typeLabel":121,"stem":489,"options":490,"answer":501,"analysis":33},936175,"下列关于泡沫比例混合器（装置）的说法中，正确的是（ ）。",[491,493,495,497,499],{"key":20,"text":492,"correct":29},"泡沫比例混合器（装置）的标注方向应与液流方向一致",{"key":24,"text":494,"correct":22},"管线式比例混合器其吸液口与泡沫液储罐或泡沫液桶最低液面的高度不得小于1．0m",{"key":27,"text":496,"correct":29},"环泵式比例混合器吸液口不应高于泡沫液储罐最低液面1 m",{"key":31,"text":498,"correct":22},"压力式比例混合装置泡沫液储罐的单罐容积不应大于5m3",{"key":133,"text":500,"correct":29},"平衡式比例混合装置平衡阀的泡沫液进口压力应大于水进口压力，且其压差应满足产品的使用要求","ACE",{"id":503,"libraryId":5,"type":120,"typeLabel":121,"stem":504,"options":505,"answer":516,"analysis":33},936176,"泡沫炮系统是一种以泡沫炮为泡沫产生与喷射装置的低倍数泡沫系统，有固定式与移动式之分，其适用场所包括（ ）。",[506,508,510,512,514],{"key":20,"text":507,"correct":29},"直径小于18 m的非水溶性液体固定顶储罐",{"key":24,"text":509,"correct":29},"围堰内的甲、乙、丙类液体流淌火灾",{"key":27,"text":511,"correct":29},"甲、乙、丙类液体汽车槽车栈台或火车槽车栈台",{"key":31,"text":513,"correct":29},"飞机库",{"key":133,"text":515,"correct":22},"汽车库","ABCD",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},936177,"泡沫灭火系统使用的常压钢质泡沫液储罐通常采用现场制作的方式。下列关于现场制作要求的说法中，正确的是（）。",[521,523,525,527],{"key":20,"text":522,"correct":22},"泡沫液管道吸液口应紧贴常压钢质泡沫液储罐底面",{"key":24,"text":524,"correct":29},"现场制作的常压钢质泡沫液储罐应进行严密性试验，试验时间应在30min以上，目测不能泄漏",{"key":27,"text":526,"correct":22},"现场制作的常压钢质泡沫液储罐，仅需对内表面进行防腐处理",{"key":31,"text":528,"correct":22},"现场制作的常压钢质泡沫液储罐的防腐处理应在严密性试验前进行",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":31,"analysis":33},936178,"主要用于移动式泡沫系统的比例混合装置是（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":22},"环泵式比例混合器",{"key":24,"text":536,"correct":22},"压力式比例混合装置",{"key":27,"text":538,"correct":22},"平衡式比例混合装置",{"key":31,"text":540,"correct":29},"管线式比例混合器",{"id":542,"libraryId":5,"type":120,"typeLabel":121,"stem":543,"options":544,"answer":150,"analysis":33},936179,"泡沫炮系统作为主要灭火设施或辅助灭火设施适用于下列场所（ ）。",[545,547,548,549,551],{"key":20,"text":546,"correct":22},"直径小于15m的非水溶性液体固定顶储罐",{"key":24,"text":509,"correct":29},{"key":27,"text":511,"correct":29},{"key":31,"text":550,"correct":22},"室外丁类液体流淌火灾",{"key":133,"text":513,"correct":29},{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":27,"analysis":33},936180,"在泡沫比例混合器进场检验时，下列项目不属于检查内容的是（ ）。",[556,558,560,562],{"key":20,"text":557,"correct":22},"泡沫比例混合器规格",{"key":24,"text":559,"correct":22},"泡沫比例混合器型号",{"key":27,"text":561,"correct":29},"泡沫比例混合器材质",{"key":31,"text":563,"correct":22},"泡沫比例混合器性能",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":24,"analysis":33},936181,"泡沫液储罐的安装位置和高度应符合设计要求，下列关于泡沫液储罐安装的说法，错误的是（ ）。",[568,570,572,574],{"key":20,"text":569,"correct":22},"泡沫液储罐周围应留有满足检修需要的通道其宽度不宜小于0．7m，且操作面不宜小于1．5m",{"key":24,"text":571,"correct":29},"当泡沫液储罐上的控制阀距地面高度大于1．2m时，应在操作面处设置操作平台或操作凳",{"key":27,"text":573,"correct":22},"储罐的安全阀出口不应朝向操作面",{"key":31,"text":575,"correct":22},"泡沫液储罐安装时，支架应与基础牢固固定，且不应拆卸和损坏配管、附件",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":27,"analysis":33},936182,"泡沫灭火系统管道安装完毕应进行水压试验，下列说法不符合规范要求的是（ ）。",[580,582,584,586],{"key":20,"text":581,"correct":22},"试验宜采用清水进行，试验时，环境温度不应低于5℃",{"key":24,"text":583,"correct":22},"试验压力应为设计压力的1．5倍",{"key":27,"text":585,"correct":29},"试验前应将泡沫产生装置、泡沫比例混合器（装置）安装调试合格后，一并参加试验",{"key":31,"text":587,"correct":22},"当环境温度低于5℃时，应采取防冻措施",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":20,"analysis":33},936183,"6％蛋白型中倍数泡沫液最小储备量大于或等于（ ）t时，应由监理工程师组织现场取样，送至具备相应资质的检测单位进行检测。",[592,594,596,598],{"key":20,"text":593,"correct":29},"2．5",{"key":24,"text":595,"correct":22},"2．0",{"key":27,"text":597,"correct":22},"3．5",{"key":31,"text":599,"correct":22},"1．0",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":31,"analysis":33},936184,"某固定顶储罐的低倍数液上喷射泡沫灭火系统，每（ ）应对除储罐上泡沫混合液立管外的其余管道全部进行冲洗，清除锈渣。",[604,606,608,610],{"key":20,"text":605,"correct":22},"月",{"key":24,"text":607,"correct":22},"季度",{"key":27,"text":609,"correct":22},"二年",{"key":31,"text":611,"correct":29},"半年",{"id":613,"libraryId":5,"type":15,"typeLabel":16,"stem":614,"options":615,"answer":20,"analysis":33},936185,"在泡沫喷淋管道安装过程中，不符合相关规范的做法是（ ）。",[616,618,620,622],{"key":20,"text":617,"correct":29},"泡沫喷淋管道支吊架与泡沫喷头之间的距离为0．2 m",{"key":24,"text":619,"correct":22},"泡沫喷淋管道支吊架与末端泡沫喷头之间的距离为0．4 m",{"key":27,"text":621,"correct":22},"泡沫喷淋分支管上每一直管段、相邻两泡沫喷头之间的管段设置的支吊架均不少于1个，且支吊架的间距为3．6m",{"key":31,"text":623,"correct":22},"当泡沫喷头的设置高度大于10 m时，支吊架的间距为3．2 m",{"id":625,"libraryId":5,"type":15,"typeLabel":16,"stem":626,"options":627,"answer":20,"analysis":33},936186,"泡沫灭火系统对阀门的质量要求较高，需要对阀门的强度和严密性进行试验，强度和严密性试验要采用（ ）进行。",[628,630,632,634],{"key":20,"text":629,"correct":29},"清水",{"key":24,"text":631,"correct":22},"氮气",{"key":27,"text":633,"correct":22},"压缩空气",{"key":31,"text":635,"correct":22},"二氧化碳",{"id":637,"libraryId":5,"type":15,"typeLabel":16,"stem":638,"options":639,"answer":31,"analysis":33},936187,"消防技术服务机构在对某单位泡沫灭火系统进行检测时，发现泡沫产生器发泡不正常。下列故障原因分析的说法中，正确的是（ ）。",[640,642,644,646],{"key":20,"text":641,"correct":22},"平衡阀的橡胶膜片由于承压过大被损坏",{"key":24,"text":643,"correct":22},"比例混合装置中的胶囊因老化、承压降低导致系统运行时发生破裂",{"key":27,"text":645,"correct":22},"泡沫液长期腐蚀混合器致使锈死",{"key":31,"text":647,"correct":29},"泡沫混合液不满足要求",[649,652,655,658,661,664],{"id":15,"name":650,"category":7,"favorite":651},"领导干部任职前廉政法规知识测试题",92,{"id":653,"name":654,"category":7,"favorite":15},595,"建筑结构与设备",{"id":656,"name":657,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":659,"name":660,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":662,"name":663,"category":7,"favorite":8},534,"BIM工程师",{"id":665,"name":663,"category":7,"favorite":8},535]