[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":648},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,3,50,2974,[13,34,46,58,70,82,94,106,118,130,148,160,172,187,199,211,223,235,247,259,274,286,298,310,322,337,352,364,376,388,400,411,426,438,450,465,477,489,501,513,525,537,549,561,573,585,599,609,624,636],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},934721,1,"单选题","(2015年真题) 对于建筑内的防烟分区设置情况进行防火检查，不应检查的是（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","防烟分区的面积",false,{"key":24,"text":25,"correct":22},"B","挡烟垂壁",{"key":27,"text":28,"correct":29},"C","送风口风速",true,{"key":31,"text":32,"correct":22},"D","防烟分区的划分","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},934723,"(2015年真题) 下列关于防火分区的做法，错误的是（）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"建筑局部设有自动灭火系统，防火分区的增加面积按该局部面积增加0.5倍计算",{"key":24,"text":41,"correct":22},"建筑第一至三层设置自动扶梯，防火分区的建筑面积按连通3个楼层的建筑面积叠加计算，并按照规范规定划分防火分区",{"key":27,"text":43,"correct":22},"叠加计算错层式汽车库上下连通层的建筑面积，防火分区的最大允许建筑面积可按规范增加1倍",{"key":31,"text":45,"correct":22},"人防工程中的水泵房、污水泵房、水池、厕所等无可燃物的房间面积可不计入防火分区面积",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},934725,"(2015年真题) 某建筑的一层至三层为商场，四层至十七层为办公，地下一层为商场，地下二层部分为商场。其余部分为设备区。室内装修及消防设施设备均符合相关规定。下列关于该建筑地下商场及设备区防火分区建筑面积，正确的是（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"商场营业厅3000㎡；设备区2000㎡",{"key":24,"text":53,"correct":22},"商场营业厅4000㎡；设备区1000㎡",{"key":27,"text":55,"correct":22},"商场营业厅4000㎡；设备区2000㎡",{"key":31,"text":57,"correct":29},"商场营业厅2000㎡；设备区2000㎡",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},934727,"(2016年真题) 对防火门进行检查时，应注意检查防火门的门扇与下框或地面的活动间隙，根据现行国家消防技术标准的规定，该间隙不应大于（）mm。",[62,64,66,68],{"key":20,"text":63,"correct":22},"3",{"key":24,"text":65,"correct":22},"6",{"key":27,"text":67,"correct":29},"9",{"key":31,"text":69,"correct":22},"12",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},934729,"（2019年真题）某10层办公楼，建筑高度为36m，标准层建筑面积为3000㎡，设置有自动喷水灭火系统，外墙采用玻璃幕墙。对该办公楼的下列防火检查结果中，不符合现行国家标准要求的是（）。",[74,76,78,80],{"key":20,"text":75,"correct":29},"九层、十层外墙上、下层开口之间防火玻璃墙的耐火极限为0.50h",{"key":24,"text":77,"correct":22},"一至四层外墙上、下层开口之间采用高度为0.80m的实体墙分隔",{"key":27,"text":79,"correct":22},"五至八层外墙上、下层开口之间采用高度为1.20m的实体墙分隔",{"key":31,"text":81,"correct":22},"标准层采用大空间办公，每层为1个防火分区",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},934731,"（2019年真题）对防火门的检验项目包括:(1)检查是否提供出厂合格证明文件;(2)检查耐火性能是否符合设计要求;(3)检查是否在防火门上明显部位设置永久性标牌;(4)检查防火门的配件是否存在机械损伤。根据现行国家标准《防火卷帘、防火门、防火窗施工及验收规范》(GB50877)，上述检验项目中属于防火门进场检验项目的共有（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"1项",{"key":24,"text":89,"correct":22},"2项",{"key":27,"text":91,"correct":22},"3项",{"key":31,"text":93,"correct":29},"4项",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},934733,"（2019年真题）某图书馆是“L”型布置，防火墙设置在内转角，两侧墙上的窗口之间的距离为3m。对该图书馆的下列防火检查结果中，不符合现行国家标准要求的是（）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"外墙上所设防火窗的耐火极限为1.00h",{"key":24,"text":101,"correct":29},"温控释放装置动作后，窗扇在70s时关闭",{"key":27,"text":103,"correct":22},"模拟火灾，可开启窗扇自动关闭",{"key":31,"text":105,"correct":22},"窗框与墙体采用预埋钢件连接",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},934735,"（2019年真题）某总建筑面积为33000㎡的地下商场,分隔为两个建筑面积不大于2000㎡的区域,区域之间采用防火隔间进行连通。对防火隔间的下列检查结果中,符合现行国家标准要求的是（）",[110,112,114,116],{"key":20,"text":111,"correct":22},"防火隔间的围护构件采用耐火极限为2.00h的防火隔墙",{"key":24,"text":113,"correct":22},"防火隔间呈长方形布置，长边为3m，短边为2m",{"key":27,"text":115,"correct":22},"通向防火隔间的门作为疏散门",{"key":31,"text":117,"correct":29},"防火隔间门的耐火极限为1.50h",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},934739,"(2017年真题) 某5层宾馆， 中部有一个贯通各层的中庭， 在二至五层的中庭四周 采用防火卷帘与其他部位分隔，首层中庭未设置防火分隔措施：其他区域划分为若干防火分区， 防火分区面积符合规范要求。 下列检查结果中， 不符合现行国家消防技术标准的是（??）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"中庭区域火灾报警信号确认后， 中庭四周的防火卷帘直接下降到楼板面",{"key":24,"text":125,"correct":29},"二层D两个防火分区之间防火分隔部位的长度为40m，使用防火墙和15m宽的防火卷帘作为防火分隔物",{"key":27,"text":127,"correct":22},"一层B两个防火分区之间防火分隔部位的长度为25m，使用防火墙和10m宽的防火卷帘作为防火分隔物",{"key":31,"text":129,"correct":22},"各分区之间的防火卷帘在切断电源后能依靠其自重下降， 但不能自动上升",{"id":131,"libraryId":5,"type":132,"typeLabel":133,"stem":134,"options":135,"answer":147,"analysis":33},934741,2,"多选题","(2017年真题) 下列防火分隔措施的检查结果中， 不符合现行国家消防技术标准的有（）",[136,138,140,142,144],{"key":20,"text":137,"correct":29},"铝合金轮载抛光厂房采用3.00h耐火极限的防火墙划分防火分区",{"key":24,"text":139,"correct":29},"电石仓库采用3.00h耐火极限的防火墙划分防火分区",{"key":27,"text":141,"correct":22},"高层宾馆防火墙两侧的窗采用乙级防火窗， 窗洞之间最近边缘的水平距离为1.0m",{"key":31,"text":143,"correct":29},"烟草成品库采用3.00h耐火极限的防火墙划分防火分区",{"key":145,"text":146,"correct":22},"E","通风机房开向建筑内的门采用甲级防火门， 消防控制室开向建筑内的门采用乙级防火门","ABD",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":33},934743,"(2018年真题) 对某高层办公楼进行防火检查，设在走道上的常开式钢制防火门的下列检查中，不符合现行国家标准要求的是（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":29},"门框内充填石棉材料",{"key":24,"text":155,"correct":22},"消防控制室手动发出关闭指令，防火门联动关闭",{"key":27,"text":157,"correct":22},"双扇防火门的门扇之间间隙为 3mm",{"key":31,"text":159,"correct":22},"防火门门扇的开启为 80N",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":27,"analysis":33},934745,"(2016年真题) 在对层高位3.5m的地下车库进行防烟分区检查时，应注意检查挡烟垂壁的材料和挡烟垂壁的高度是否满足现行国家消防技术标准的要求，下列挡烟垂壁的做法中，错误的有（??）",[164,166,168,170],{"key":20,"text":165,"correct":22},"挡烟垂壁的最下端低于机械排烟口",{"key":24,"text":167,"correct":22},"挡烟垂壁突出顶棚500mm",{"key":27,"text":169,"correct":29},"制作挡烟垂壁的材料为5mm厚的普通玻璃",{"key":31,"text":171,"correct":22},"在挡烟垂壁明显位置设置永久性标志铭牌",{"id":173,"libraryId":5,"type":132,"typeLabel":133,"stem":174,"options":175,"answer":186,"analysis":33},934747,"(2016年真题)某消防服务机构对建筑面积为30000m2的大型地下商场进行安全评估，在对防火隔间进行检查时发现，防火分区通向防火隔间的门为乙级防火门，两个乙级防火门的间距为4米，隔间的装修为轻钢龙骨石膏板吊顶，阻燃壁纸装饰墙面，隔间内有几位顾客坐在座椅上休息。根据现行国家消防技术标准，该防火隔间不符合现行国家消防技术标准规定的有（??）。",[176,178,180,182,184],{"key":20,"text":177,"correct":29},"防火隔间的门为乙级防火门",{"key":24,"text":179,"correct":22},"采用轻钢龙骨石膏板吊顶",{"key":27,"text":181,"correct":29},"设置供人员休息用的座椅",{"key":31,"text":183,"correct":22},"不同防火分区开向防火隔间门的距离为4m",{"key":145,"text":185,"correct":29},"采用阻燃壁纸装饰墙面","ACE",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":31,"analysis":33},934750,"(2017年真题)某三层内廊式办公楼，建筑高度12.5m，三级耐火等级，设置自动喷水灭火系统，每层建筑面积均为1400m2，有2部采用双向弹簧门的封闭式楼梯间。该办公楼每层一个防火分区的最大建筑面积为（??）m2",[191,193,195,197],{"key":20,"text":192,"correct":22},"1200",{"key":24,"text":194,"correct":22},"2400",{"key":27,"text":196,"correct":22},"2800",{"key":31,"text":198,"correct":29},"1400",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":31,"analysis":33},934752,"(2017年真题)某单层平屋面多功能厅，建筑面积 600m2 ，屋面板底距室内地面7.0m，结构梁从顶板 下突出0.6m，吊顶采用楼空轻钢格栅， 吊顶下表面距离内地面5.5m，该多功能厅设有自动喷水灭火系统、火灾自动报警系统和机械排烟系统。 下列关于该多功能厅防烟分区划分的说法中，正确的是（??）。",[203,205,207,209],{"key":20,"text":204,"correct":22},"该多功能厅应采用屋面板底下垂高度不小于0.5m的挡烟垂壁划分为2个防烟分区",{"key":24,"text":206,"correct":22},"该多功能厅应利用室内结构梁划分为2个防烟分区",{"key":27,"text":208,"correct":22},"该多功能厅应采用自吊顶底下垂高度不小于0.5m的活动挡烟垂壁划分为2个防烟分区",{"key":31,"text":210,"correct":29},"该多功能厅可不划分防烟分区",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":33},934754,"(2017年真题)在对某办公楼进行检查时，查阅图纸资料得知，该楼为钢筋混凝土框架结构，柱、梁、楼板的设计耐火极限分别为3.00h、2.00h、1.50h，每层划分为2个防火分区。下列检查结果中，不符合现行国家消防技术标准的是（??）。",[215,217,219,221],{"key":20,"text":216,"correct":22},"将内走廊上原设计的常闭式甲级防火门改为常开式甲级防火门",{"key":24,"text":218,"correct":29},"将二层原设计的防火墙移至一层餐厅中部的次梁对应位置上，防火分区面积仍然符合规范要求",{"key":27,"text":220,"correct":22},"将其中一个防火分区原设计活动式防火窗改为常闭式防火窗",{"key":31,"text":222,"correct":22},"排烟防火阀处于开启状态，但能与火灾报警系统联动和现场手动关闭",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":31,"analysis":33},934756,"(2017年真题)某单层白酒仓库，占地面积900m2。库房内为进行防火分隔，未设置自动灭火和火灾自动报警设施 ，储存陶坛装酒精度为38°及以上的白酒。防火检查时提出的下列防火分区的处理措施中， 正确的是（??）",[227,229,231,233],{"key":20,"text":228,"correct":22},"将该仓库作为一个防火分区， 同时设置自动灭火系统和火灾自动报警系统",{"key":24,"text":230,"correct":22},"将该仓库用耐火极限为4.00h的防火墙平均分成 4个防火分区，并设置火灾自动报警系统",{"key":27,"text":232,"correct":22},"将该仓库用耐火极限为3.00h且满足耐火完整性和耐火隔热性判定条件的防火卷帘划分5个防火分区， 最大防火分区面积不超过200m2",{"key":31,"text":234,"correct":29},"将该仓库用耐火极限为4.00h的防火墙平均分成2个防火分区， 并设置火灾自动灭火系统",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":27,"analysis":33},934758,"(2018年真题)对某建筑进行防火检查，变形缝的下列检查结果中，不符合现行国家标准要求的是( )",[239,241,243,245],{"key":20,"text":240,"correct":22},"变形缝的填充材料采用防火枕",{"key":24,"text":242,"correct":22},"空调系统的风管穿越防火分隔处的变形缝时，变形缝两侧风管设置公称动作温度为70℃的防火阀",{"key":27,"text":244,"correct":29},"在可燃气体管道穿越变形缝处加设了阻燃PVC套管",{"key":31,"text":246,"correct":22},"变形缝的构造基层采用镀锌钢板",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},934760,"(2018年真题)某大型城市综合体的餐饮、商店等商业设施通过有顶棚的步行街连接，且需利用步行街进行安全疏散。对该步行街进行防火检查，下列检查结果中，不符合现行国家标准要求的是（）",[251,253,255,257],{"key":20,"text":252,"correct":22},"步行街的顶棚为玻璃顶",{"key":24,"text":254,"correct":29},"步行街的顶棚距地面的高度为5.8m",{"key":27,"text":256,"correct":22},"步行街顶棚承重结构采用经防火保护的钢构件，耐火极限为1.50h",{"key":31,"text":258,"correct":22},"步行街两侧建筑之间的最近距离为13m",{"id":260,"libraryId":5,"type":132,"typeLabel":133,"stem":261,"options":262,"answer":273,"analysis":33},934762,"(2018年真题)某大型地下商业建筑，占地面积30000㎡。下列对该建筑防火分隔措施的检查结果中，不符合现行国家标准要求的有( )。",[263,265,267,269,271],{"key":20,"text":264,"correct":22},"消防控制室房间门采用乙级防火门",{"key":24,"text":266,"correct":29},"空调机房房间门采用乙级防火门",{"key":27,"text":268,"correct":22},"气体灭火系统储瓶间房间门采用乙级防火门",{"key":31,"text":270,"correct":29},"变配电室房间门采用乙级防火门",{"key":145,"text":272,"correct":29},"通风机房房间门采用乙级防火门","BDE",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},934764,"(2018年真题)某建筑面积为 44000 ㎡的地下商场，采用防火分隔措施将商场分隔为多个建筑面积不大于 20000㎡的区域。该商场对区域之间局部需要联通的部位采取的防火分隔措施中，符合现行国家标准《建筑设计防火规范》 (GB 50016)的是（??）",[278,280,282,284],{"key":20,"text":279,"correct":22},"采用耐火极限为 3.00h 的防火墙分隔，墙上设置了甲级防火门",{"key":24,"text":281,"correct":29},"采用防烟楼梯间分隔，楼梯间门为甲级防火门",{"key":27,"text":283,"correct":22},"采用防火隔间分隔，墙体采用耐火极限为 2.00h 的防火隔墙",{"key":31,"text":285,"correct":22},"采用避难走道分隔，避难走道防火隔墙的耐火极限为 2.00h",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},934766,"(2018年真题)商场的防火分区釆用防火墙和防火卷帘进行分隔。对该建筑防火卷帘的检查测试结果中，不符合现行国家标准要求的是( )",[290,292,294,296],{"key":20,"text":291,"correct":22},"垂直卷帘电动启、闭的运行速度为7m\u002Fmin",{"key":24,"text":293,"correct":29},"防火卷帘装配温控释放装置，当释放装置的感温元件周围温度达到79℃时，释放装置动作卷帘依自重下降关闭",{"key":27,"text":295,"correct":22},"疏散通道上的防火卷帘的控制器在接收到专门用于联动防火卷帘的感烟火灾探测器的报警信号后下降至距楼板面1.8m处",{"key":31,"text":297,"correct":22},"防火卷帘的控制器及手动按钮盒安装在底边距地面高度为1.5m的位置",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":31,"analysis":33},934768,"(2016年真题)关于防火阀和排烟防火阀在建筑通风和排烟系统中的设置要求，下列说法中，错误的是（??）",[302,304,306,308],{"key":20,"text":303,"correct":22},"排烟防火阀开启和关闭的动作信号应反馈至消防联动控制器",{"key":24,"text":305,"correct":22},"防火阀和排烟防火阀应具备温感器控制方式",{"key":27,"text":307,"correct":22},"安装在排烟风机入口总管处的排烟防火阀关闭后，应直接联动控制排烟风机停止运转",{"key":31,"text":309,"correct":29},"当建筑内每个防火分区的通风、空调系统均独立设置时，水平风管与竖向总管的交接处应设置防火阀",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},934770,"(2016年真题) 对防火分区进行检查时，应该检查防火分区的建筑面积。根据现行国家消防技术标准的规定，下列因素中，不影响防火分区的建筑面积划分的是（??）",[314,316,318,320],{"key":20,"text":315,"correct":22},"使用性质",{"key":24,"text":317,"correct":29},"防火间距",{"key":27,"text":319,"correct":22},"耐火等级",{"key":31,"text":321,"correct":22},"建筑高度",{"id":323,"libraryId":5,"type":132,"typeLabel":133,"stem":324,"options":325,"answer":336,"analysis":33},934772,"（2020年真题）某公共建筑，建筑高度为34m，总建筑面积为83000m2。地上7层，使用功能为商场;地下2层，使用功能为机械式汽车库。建筑商业营业厅采用不燃材料装修，一至三层设有中庭，建筑内设有火灾自动报警系统和自动灭火系统。对该建筑进行防火检查，下列检查结果中，符合现行国家标准要求的有（ ）。",[326,328,330,332,334],{"key":20,"text":327,"correct":22},"汽车库最大防火分区建筑面积为3650m2",{"key":24,"text":329,"correct":29},"商场最大防火分区建筑面积为3850m2",{"key":27,"text":331,"correct":22},"与中庭相连通的门为乙级防火门",{"key":31,"text":333,"correct":22},"汽车库采用防火墙和耐火极限为1.50h的不燃性楼板与其他部位分隔",{"key":145,"text":335,"correct":29},"中庭与周围连通空间采用耐火极限为1.00h的防火隔墙分隔","BE",{"id":338,"libraryId":5,"type":132,"typeLabel":133,"stem":339,"options":340,"answer":351,"analysis":33},934774,"（2020年真题）某消防技术服务机构对某高层建筑进行消防安全评估，下列检查结果中符合现行国家标准要求的有（ ）。",[341,343,345,347,349],{"key":20,"text":342,"correct":22},"油浸变压器室开向建筑内的门采用乙级防火门",{"key":24,"text":344,"correct":22},"开向相邻防火分区的门采用乙级防火门",{"key":27,"text":346,"correct":22},"避难层内设备间开向避难层区的门采用乙级防火门",{"key":31,"text":348,"correct":29},"电梯候梯厅通往地下汽车库的出口采用乙级防火门",{"key":145,"text":350,"correct":29},"消防控制室开向建筑内的门采用乙级防火门","DE",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":24,"analysis":33},934776,"（2020年真题）对某建筑内设置的防火门进行检查，其中一樘防火门型号为MFM-1221-d681.00-2。关于该防火门的说法，错误的是（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"该门为木质防火门",{"key":24,"text":359,"correct":29},"该门为单扇防火门",{"key":27,"text":361,"correct":22},"该防火门耐火完整性的时间不小于1.00h",{"key":31,"text":363,"correct":22},"该防火门耐火隔热性的时间不小于0.50h",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":24,"analysis":33},934778,"（2020年真题）某大型商业综合体，地下一层各餐饮场所的建筑面积均小于150m2，每家可容纳人数均少于70人。下列检查结果中，不符合《大型商业综合体消防管理规则（试行）》（应急消（2019）314号）的是（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":22},"餐饮场所集中设置在西北侧",{"key":24,"text":371,"correct":29},"厨房区域采用60mm厚的增强石膏轻质板墙与其他部位分隔",{"key":27,"text":373,"correct":22},"开放式食品加工区使用电磁炉进行食品加工",{"key":31,"text":375,"correct":22},"餐饮场所采用管道天然气供气进行食品加工",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":31,"analysis":33},934780,"（2020年真题）下列防火卷维护管理的做法中，不符合现行国家标准《防火窗施工及验收规范》（GB 50877）的是（ ）。",[380,382,384,386],{"key":20,"text":381,"correct":22},"每周手动启动防火卷帘内外两侧控制器上的控制按钮，检查下降、停止功能",{"key":24,"text":383,"correct":22},"每月手动操作防火卷帘手动速放装置，检查防火卷帘依靠自",{"key":27,"text":385,"correct":22},"每季度手动操作防火卷帘的手动拉链，检查防火卷帘的手动升降",{"key":31,"text":387,"correct":29},"每周检查防火卷帘下部是否存在影响下降的障碍物",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":27,"analysis":33},934782,"(2016年真题) 高层医疗建筑采用双面布房的疏散走道,其净宽度根据疏散人数计算确定,并应满足不小于()m的要求。",[392,394,396,398],{"key":20,"text":393,"correct":22},"1.1",{"key":24,"text":395,"correct":22},"1.2",{"key":27,"text":397,"correct":29},"1.5",{"key":31,"text":399,"correct":22},"1.4",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":24,"analysis":33},934784,"(2015年真题) 设置剪刀楼梯是当相邻两个安全出口的间距难以满足不应小于5m时的变通措施，对底部数层为商场和步行购物街、上部为塔楼的建筑进行防火监察时，检查人员应注意核对设置剪刀楼梯的合理性，任一门户或疏散门至最近疏散楼梯间入口的距离不应大于（）m。",[404,406,408,410],{"key":20,"text":405,"correct":22},"5",{"key":24,"text":407,"correct":29},"10",{"key":27,"text":409,"correct":22},"7",{"key":31,"text":69,"correct":22},{"id":412,"libraryId":5,"type":132,"typeLabel":133,"stem":413,"options":414,"answer":425,"analysis":33},934786,"(2015年真题) 某纺织厂房，地上3层，耐火等级为2级，建筑高度18m，建筑面积16800㎡，设置4部疏散楼梯间。下列关于疏散楼梯间的做法，正确的有（）。",[415,417,419,421,423],{"key":20,"text":416,"correct":29},"厂房的3部疏散楼梯间靠外墙布置，并具备天然采光和自然通风条件，设置为封闭楼梯间。",{"key":24,"text":418,"correct":22},"厂房的1部疏散楼梯间不能自然通风采光，因厂房的建筑高度小于32m，防烟楼梯间可不设置前室。",{"key":27,"text":420,"correct":29},"厂房的1部疏散楼梯间不能自然通风采光，将其改为防烟楼梯间。",{"key":31,"text":422,"correct":29},"封闭楼梯间，防烟楼梯间的顶棚，墙面和地面的装饰材料均采用不燃烧材料。",{"key":145,"text":424,"correct":22},"其中1部封闭楼梯间开设防火门有困难，采用防火卷帘代替。","ACD",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":20,"analysis":33},934788,"(2016年真题) 下列关于建筑中疏散门宽度的说法中，错误的是（）。",[430,432,434,436],{"key":20,"text":431,"correct":29},"电影院观众厅的疏散门，其净宽度不应小于1.2m",{"key":24,"text":433,"correct":22},"多层办公建筑内的疏散门，其净宽度不应小于0.9m",{"key":27,"text":435,"correct":22},"地下歌舞娱乐场所的疏散门，其净宽度应根据疏散人数按每100人不小于1.0m计算",{"key":31,"text":437,"correct":22},"住宅建筑的户门，其净宽度不应小于0.9m",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},934790,"(2015年真题) 某购物中心，地下2层，建筑面积65000㎡，设置南、北2个开敞的下沉式广场。下列做法正确的是（）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"分隔后的购物中心不同区域通向北下沉式广场开口最近边缘的水平距离宜为12m",{"key":24,"text":445,"correct":29},"南、北下沉式广场各设置1部直通室外地面并满足疏散宽度指标的疏散通道",{"key":27,"text":447,"correct":22},"南下沉式广场上方设雨篷，其开口面积为该空间地面面积20%",{"key":31,"text":449,"correct":22},"下沉式广场设置商业零售点，但不影响人员疏散",{"id":451,"libraryId":5,"type":132,"typeLabel":133,"stem":452,"options":453,"answer":464,"analysis":33},934792,"(2015年真题) 消防技术人员对某工业区进行安全检查，下列仅设置一个安全出口的生产场所中，符合安全出口设置要求的场所有（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"某甲类厂房，每层建筑面积120㎡，同一时间作业人数3人",{"key":24,"text":457,"correct":29},"某戊类厂房，每层建筑面积300㎡，同一时间作业人数24人",{"key":27,"text":459,"correct":29},"某丁类厂房，每层建筑面积350㎡，同一时间作业人数20人",{"key":31,"text":461,"correct":22},"某乙类厂房，每层建筑面积180㎡，同一时间作业人数8人",{"key":145,"text":463,"correct":22},"某丙类厂房，每层建筑面积260㎡，同一时间作业人数18人","BC",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":20,"analysis":33},934794,"(2015年真题) 某地下商场，地下1层，建筑面积接近40000㎡，通过设置避难走道划分为建筑面积小于20000㎡的两个区域，下列关于避难走道的做法，错误的是()。",[469,471,473,475],{"key":20,"text":470,"correct":29},"商场至避难走道入口处设防烟前室，商场开向前室的门采用乙级防火门",{"key":24,"text":472,"correct":22},"避难走道在2个不同疏散方向上分别设置1个直通室外地面的出口",{"key":27,"text":474,"correct":22},"避难走道入口处防烟前室的使用面积为6.0㎡",{"key":31,"text":476,"correct":22},"避难走道的吊顶、墙面和地面采用不燃烧装修材料",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":27,"analysis":33},934796,"(2015年真题) 某超高层办公建筑，建筑高度为180m,共设置有3个避难层。投入使用前对避难层进行检查，下列检查结果中，正确的是（）。",[481,483,485,487],{"key":20,"text":482,"correct":22},"设置了独立的机械排烟设施",{"key":24,"text":484,"correct":22},"第一个避难层的楼地面与灭火救援地地面的高差为55m",{"key":27,"text":486,"correct":29},"通向避难层的疏散楼梯在避难层进行了分隔",{"key":31,"text":488,"correct":22},"避难层兼作设备层，避难区域与设备管道采用耐火极限1.0h的防火墙分隔",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":31,"analysis":33},934798,"(2016年真题) 某大型地下商场，建筑面积为4000㎡，采用兼做人员疏散的下沉式广场进行防火分隔，下列关于下沉式广场的做法中，正确的是（）。",[493,495,497,499],{"key":20,"text":494,"correct":22},"用于疏散的净面积为125㎡",{"key":24,"text":496,"correct":22},"设置防风雨棚，四周开口高度为0.5m",{"key":27,"text":498,"correct":22},"中间区域通向下沉式广场的开口之间，最大水平距离为10m",{"key":31,"text":500,"correct":29},"有一部满足疏散宽度要求的直通地面的疏散楼梯",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":27,"analysis":33},934800,"（2019年真题）某建筑高度为39m的住宅，共2个单元，地上一至二层为商业服务网点，对该住宅楼的下列防火检查结果中，不符合现行国家标准要求的是（）",[505,507,509,511],{"key":20,"text":506,"correct":22},"每个单元设1部疏散楼梯并通过屋面连通",{"key":24,"text":508,"correct":22},"消防电梯在商业服务网点不开口",{"key":27,"text":510,"correct":29},"户门为乙级防火门，疏散楼梯间采用封闭楼梯间",{"key":31,"text":512,"correct":22},"户门的净宽度均为0.9m",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":31,"analysis":33},934802,"（2019年真题）某12层病房楼,设有火灾自动报警系统和自动喷水灭火系统。该建筑每层有3个护理单元,洁净手术部设置在第十二层,在二层以上的楼层设置了避难间。对该病房楼的下列防火检查结果中,不符合现行国家标准要求的是（）",[517,519,521,523],{"key":20,"text":518,"correct":22},"每层设置了2个避难间",{"key":24,"text":520,"correct":22},"在走道及避难间均设置了消防专线电话和应急广播",{"key":27,"text":522,"correct":22},"每个避难间均设有可开启的乙级防火窗",{"key":31,"text":524,"correct":29},"每层避难间的总净面积为50㎡",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":24,"analysis":33},934804,"（2019年真题）某建筑髙度为30m的写字楼,标准层建筑面积为800㎡，人均使用面积为6㎡,采用剪刀楼梯间。对该写字楼的下列防火检查结果中,符合现行国家标准要求的是（）",[529,531,533,535],{"key":20,"text":530,"correct":22},"楼梯间共用一套机械加压送风系统",{"key":24,"text":532,"correct":29},"梯段之间隔墙的耐火极限为2.00h",{"key":27,"text":534,"correct":22},"其中一间办公室门至最近安全出口的距离为15m",{"key":31,"text":536,"correct":22},"梯段的净宽度为1.1m",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":31,"analysis":33},934806,"（2019年真题）某博物馆附属的地下2层丙类仓库，每层建筑面积为900㎡，每层划分为2个防火分区，设有自动喷水灭火系统，对该仓库的下列防火检查结果中，不符合现行国家标准要求的是（）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"仓库通向疏散走道的门采用乙级防火门",{"key":24,"text":544,"correct":22},"仓库通向疏散楼梯间的门采用乙级防火门",{"key":27,"text":546,"correct":22},"地下二层1个防火分区的两个安全出口中的1个安全出口借用相邻防火分区疏散",{"key":31,"text":548,"correct":29},"地下二层建筑面积为300㎡的防火分区，设1个安全出口",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},934808,"（2019年真题）某病房楼，共6层，建筑高度为28m，每层建筑面积为3000㎡，划分为2个护理单元，对该病房楼的下列防火检查结果中，符合现行国家标准要求的是（）",[553,555,557,559],{"key":20,"text":554,"correct":22},"疏散楼梯间为封闭楼梯间",{"key":24,"text":556,"correct":29},"每层设1个避难间",{"key":27,"text":558,"correct":22},"四层为单面布房，走道净宽度为1.30m",{"key":31,"text":560,"correct":22},"位于袋形走道尽端的病房门至最近安全出囗的直线距离为18m",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":31,"analysis":33},934810,"（2019年真题）某造纸厂干燥车间，耐火等级为二级，地上2层，每层划分4个防火分区，地下局部1层，划分为2个防火分区。该车间采用自动化生产工艺，平时只有巡检人员。对该车间的下列防火检查结果中，不符合现行国家标准要求的是（）。",[565,567,569,571],{"key":20,"text":566,"correct":22},"首层的最大疏散距离为60m",{"key":24,"text":568,"correct":22},"地下一层1个防火分区的其中1个安全出口借用相邻防火分区疏散",{"key":27,"text":570,"correct":22},"首层外门的净宽度为1.2m",{"key":31,"text":572,"correct":29},"地上二层1个防火分区的其中1个安全出口借用相邻防火分区疏散",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},934812,"（2019年真题）某电子元件生产厂房首层2个防火分区有疏散门通向避难走道，其中，防火分区一设置1个门通向该避难走道门的净宽为1.20m，防火分区二有2个净宽均为1.20m的门通向避难走道。对该厂房的下列防火检查结果中，不符合现行国家标淮要求的是（）。",[577,579,581,583],{"key":20,"text":578,"correct":29},"避难走道设1个直通室外的出口",{"key":24,"text":580,"correct":22},"避难走道的净宽度为2.40m",{"key":27,"text":582,"correct":22},"避难走道入口处前室的使用面积为6.0㎡",{"key":31,"text":584,"correct":22},"进入避难走道前室的门为甲级防火门",{"id":586,"libraryId":5,"type":132,"typeLabel":133,"stem":587,"options":588,"answer":336,"analysis":33},934814,"（2019年真题）某二级耐火等级的服装加工厂房，地上5层，建筑高度为30m，每层建筑面积为6000㎡。该厂房首层、二层的人数均为600人，三至五层的人数均为300人。对该厂房的下列防火检查结果中，不符合现行国家标准要求的有（）",[589,591,593,595,597],{"key":20,"text":590,"correct":22},"疏散楼梯采用封闭楼梯间",{"key":24,"text":592,"correct":29},"第四层最大的疏散距离为60m",{"key":27,"text":594,"correct":22},"楼梯间的门采用常开乙级防火门",{"key":31,"text":596,"correct":22},"办公室与车间连通的门采用乙级防火门",{"key":145,"text":598,"correct":29},"首层外门的总净宽度为3.6m",{"id":600,"libraryId":5,"type":132,"typeLabel":133,"stem":601,"options":602,"answer":608,"analysis":33},934816,"（2019年真题）某二级耐火等级的服装加工厂房，地上5层，建筑高度为30m，每层建筑面积为6000㎡，该厂房首层、二层的人数均为600人，三至五层的人数均为300人，对该厂房的下列防火检查结果中，不符合现行国家标准要求的有（）",[603,604,605,606,607],{"key":20,"text":592,"correct":29},{"key":24,"text":598,"correct":29},{"key":27,"text":590,"correct":22},{"key":31,"text":594,"correct":22},{"key":145,"text":596,"correct":22},"AB",{"id":610,"libraryId":5,"type":132,"typeLabel":133,"stem":611,"options":612,"answer":623,"analysis":33},934818,"（2019年真题）某建材商场，地下3层，地上5层，建筑高度为30m，地上每层建筑面积为8000㎡，划分为2个防火分区。对该商场的下列防火检查结果中不符合现行国家标准要求的有（）",[613,615,617,619,621],{"key":20,"text":614,"correct":22},"空调通风管道穿越楼梯间，采用金属风管",{"key":24,"text":616,"correct":22},"第四层营业厅的最大疏散距离为35m",{"key":27,"text":618,"correct":29},"因搬运大件货物需要，有1部疏散楼梯入口处采用防火卷帘分隔",{"key":31,"text":620,"correct":29},"水暖管道井的检修门开向楼梯间，采用甲级防火门",{"key":145,"text":622,"correct":22},"地上第三层人员密度为0.13人\u002F㎡，该疏散楼梯的总净宽度为11m","CD",{"id":625,"libraryId":5,"type":15,"typeLabel":16,"stem":626,"options":627,"answer":27,"analysis":33},934820,"(2017年真题) 下列一、二级耐火等级建筑的疏散走道和安全出口的检查结果中，不符合现行国家消防技术标准的是（??）",[628,630,632,634],{"key":20,"text":629,"correct":22},"容纳4500人的单层体育馆，其室外疏散通道的净宽度为3.50m",{"key":24,"text":631,"correct":22},"一座2层老年人公寓中，位于袋形走道两侧的房间疏散门至最近疏散楼梯间的直线距离为18m",{"key":27,"text":633,"correct":29},"单元式住宅中公共疏散走道净宽度为1.05m",{"key":31,"text":635,"correct":22},"采用敞开式外廊的多层办公楼中，从袋形走道尽端的疏散门至最近封闭楼梯间的直线距离为27m",{"id":637,"libraryId":5,"type":15,"typeLabel":16,"stem":638,"options":639,"answer":24,"analysis":33},934822,"(2017年真题) 对大型地下商业建筑进行防火检查时，发现下沉式广场防风雨棚的做法中，错误的是（）",[640,642,644,646],{"key":20,"text":641,"correct":22},"防风雨棚四周开口部位均匀布置",{"key":24,"text":643,"correct":29},"防风雨棚开口高度为0.8m",{"key":27,"text":645,"correct":22},"防风雨棚开口的面积为改空间地面面积的25%",{"key":31,"text":647,"correct":22},"防风雨棚开口位置设置百叶， 其有效排烟 面积为开口面积的60%",[649,652,655,658,661,664],{"id":15,"name":650,"category":7,"favorite":651},"领导干部任职前廉政法规知识测试题",92,{"id":653,"name":654,"category":7,"favorite":15},595,"建筑结构与设备",{"id":656,"name":657,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":659,"name":660,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":662,"name":663,"category":7,"favorite":8},534,"BIM工程师",{"id":665,"name":663,"category":7,"favorite":8},535]