[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":628},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,29,50,2974,[13,38,52,64,76,88,100,111,123,135,150,162,173,185,197,208,220,232,244,256,268,280,292,307,322,336,348,360,372,380,392,402,414,426,438,450,462,473,484,499,514,529,540,549,559,571,583,595,607,616],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},936088,2,"多选题","细水雾灭火系统是一种灭火效能高、环保、使用范围较广的灭火系统。在对细水雾灭火系统的管网试压试验中，以下试验条件或操作符合规范要求的有（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","水压试验环境温度应不低于0℃，当低于0℃时，应采取防冻措施",false,{"key":24,"text":25,"correct":26},"B","试验压力为系统工作压力的1．5倍",true,{"key":28,"text":29,"correct":26},"C","试验用水的水质与管道的冲洗水一致，水中氯离子含量不超过25 mg／kg",{"key":31,"text":32,"correct":22},"D","试验的测试点设在系统管网的最高点",{"key":34,"text":35,"correct":22},"E","当压力升至试验压力后，稳压5 min，管道无损坏、变形，再将试验压力降至设计压力，稳压90min","BC","",{"id":39,"libraryId":5,"type":40,"typeLabel":41,"stem":42,"options":43,"answer":24,"analysis":37},936089,1,"单选题","下列场所，宜选用全淹没应用方式的开式细水雾灭火系统的是（ ）。",[44,46,48,50],{"key":20,"text":45,"correct":22},"油浸变压器室",{"key":24,"text":47,"correct":26},"液压站",{"key":28,"text":49,"correct":22},"柴油发电机房",{"key":31,"text":51,"correct":22},"燃油锅炉房",{"id":53,"libraryId":5,"type":40,"typeLabel":41,"stem":54,"options":55,"answer":28,"analysis":37},936090,"下列关于瓶组式细水雾灭火系统的说法中，错误的是（ ）。",[56,58,60,62],{"key":20,"text":57,"correct":22},"系统采用储气瓶组和储水瓶组中的储气容器和储水容器分别贮存高压氮气和水",{"key":24,"text":59,"correct":22},"系统启动时高压气体释放出来驱动水形成细水雾",{"key":28,"text":61,"correct":26},"系统在备用状态下，储水容器处于高压状态，储气容器处于常压状态",{"key":31,"text":63,"correct":22},"系统由细水雾喷头、储水瓶组、储气瓶组、分区控制阀、驱动装置、气体单向阀、安全泄放装置等部件组成",{"id":65,"libraryId":5,"type":40,"typeLabel":41,"stem":66,"options":67,"answer":31,"analysis":37},936091,"下列不属于泵组式细水雾灭火系统组件的是（ ）。",[68,70,72,74],{"key":20,"text":69,"correct":22},"分区控制阀",{"key":24,"text":71,"correct":22},"泄压调压阀",{"key":28,"text":73,"correct":22},"信号反馈装置",{"key":31,"text":75,"correct":26},"储气瓶组",{"id":77,"libraryId":5,"type":40,"typeLabel":41,"stem":78,"options":79,"answer":31,"analysis":37},936092,"根据现行国家标准《细水雾灭火系统技术规范》GB 50898—2013的规定，喷头与管道的连接宜采用（ ）。",[80,82,84,86],{"key":20,"text":81,"correct":22},"粘结剂",{"key":24,"text":83,"correct":22},"聚四氟乙烯",{"key":28,"text":85,"correct":22},"麻丝",{"key":31,"text":87,"correct":26},"端面密封",{"id":89,"libraryId":5,"type":40,"typeLabel":41,"stem":90,"options":91,"answer":20,"analysis":37},936093,"细水雾灭火系统管道穿越楼板时应加设套管，套管的长度应高出楼地面（ ）mm。",[92,94,96,98],{"key":20,"text":93,"correct":26},"50",{"key":24,"text":95,"correct":22},"70",{"key":28,"text":97,"correct":22},"100",{"key":31,"text":99,"correct":22},"120",{"id":101,"libraryId":5,"type":40,"typeLabel":41,"stem":102,"options":103,"answer":31,"analysis":37},936094,"下列细水雾灭火系统阀门组件中，属于开式系统特有的是（ ）。",[104,105,107,109],{"key":20,"text":69,"correct":22},{"key":24,"text":106,"correct":22},"试水阀",{"key":28,"text":108,"correct":22},"手动排气阀",{"key":31,"text":110,"correct":26},"泄放试验阀",{"id":112,"libraryId":5,"type":40,"typeLabel":41,"stem":113,"options":114,"answer":31,"analysis":37},936095,"细水雾灭火系统采用特殊喷头在压力作用下喷洒细水雾进行灭火或控火，是一种灭火效能较高、环保、适用范围较广的灭火系统，具有广泛的工程应用前景。根据《细水雾灭火系统技术规范》（GB50898—2013），下列说法不符合规范要求的是（ ）。",[115,117,119,121],{"key":20,"text":116,"correct":22},"开式细水雾系统的自动控制应能在接收到两个独立的火灾报警信号后自动启动",{"key":24,"text":118,"correct":22},"闭式细水雾系统的自动控制应能在喷头动作后，由动作信号反馈装置直接联锁自动启动",{"key":28,"text":120,"correct":22},"手动启动装置和机械应急操作装置应能在一处完成系统启动的全部操作，并应采取防止误操作的措施",{"key":31,"text":122,"correct":26},"瓶组式系统应具有自动、手动和机械应急操作控制方式，其机械应急操作应能在消防控制室内直接手动启动系统",{"id":124,"libraryId":5,"type":40,"typeLabel":41,"stem":125,"options":126,"answer":28,"analysis":37},936096,"细水雾灭火系统出现泵组连接处有渗漏的故障，其原因分析不正确的是（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":22},"连接件松动",{"key":24,"text":130,"correct":22},"连接处O形密封圈或密封垫损坏",{"key":28,"text":132,"correct":26},"泵组测试阀未关闭",{"key":31,"text":134,"correct":22},"连接件损坏",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":149,"analysis":37},936097,"消防技术服务机构对某电信机房安装的瓶组式细水雾灭火系统进行验收前的检测工作，在检验有关产品质量合格证明文件时，发现该灭火系统使用的储水瓶、储气瓶均不具备《气瓶安全技术监察规程》规定的合格证明文件，但产品有某国家级消防产品检验中心出具的型式试验合格报告。下列结论中，正确的有（ ）。",[139,141,143,145,147],{"key":20,"text":140,"correct":22},"该灭火系统具有合格的型式试验报告，可以使用",{"key":24,"text":142,"correct":26},"该灭火系统不符合《消防产品监督管理规定》及有关安全法规的要求，不能使用",{"key":28,"text":144,"correct":26},"储水瓶、储气瓶应取得《气瓶安全技术监察规程》规定的合格证明文件",{"key":31,"text":146,"correct":22},"该灭火系统可暂时使用，应在产品保修期内更换储水瓶、储气瓶",{"key":34,"text":148,"correct":26},"型式试验合格报告不能证明使用于该工程的储水瓶、储气瓶符合特种设备安全监察管理规定","BCE",{"id":151,"libraryId":5,"type":40,"typeLabel":41,"stem":152,"options":153,"answer":24,"analysis":37},936098,"下列关于气体灭火系统灭火剂输送管道安装的说法中，错误的是（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"已经防腐处理的无缝钢管不宜采用焊接连接",{"key":24,"text":157,"correct":26},"采用螺纹连接时，管材宜采用气焊气割",{"key":28,"text":159,"correct":22},"采用法兰连接时，衬垫不得凸入管内",{"key":31,"text":161,"correct":22},"灭火剂输送管道与选择阀等个别连接部位需采用法兰焊接连接时，应对被焊接损坏的防腐层进行二次防腐处理",{"id":163,"libraryId":5,"type":40,"typeLabel":41,"stem":164,"options":165,"answer":31,"analysis":37},936099,"气体灭火系统灭火剂输送管道设置在室内活动地板下时，可涂红色油漆色环，色环宽度不应小于（ ）mm。",[166,168,170,172],{"key":20,"text":167,"correct":22},"20",{"key":24,"text":169,"correct":22},"30",{"key":28,"text":171,"correct":22},"40",{"key":31,"text":93,"correct":26},{"id":174,"libraryId":5,"type":40,"typeLabel":41,"stem":175,"options":176,"answer":24,"analysis":37},936100,"某书库划分为一个防护区，采用预制七氟丙烷气体灭火系统保护，系统调试完毕后某消防设施检测机构的工作人员对其进行检测。下列检测结果中，不符合现行国家技术标准的是（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":22},"系统内设置了5台预制灭火装置，5台预制灭火装置同时启动时，动作响应时差为1s",{"key":24,"text":180,"correct":26},"灭火剂释放后，防护区内的通风口自动关闭",{"key":28,"text":182,"correct":22},"防护区的门采用B1．00防火门",{"key":31,"text":184,"correct":22},"系统设有自动控制和手动控制方式，未设置机械应急操作控制方式",{"id":186,"libraryId":5,"type":40,"typeLabel":41,"stem":187,"options":188,"answer":28,"analysis":37},936101,"气体灭火系统的（ ）是在组合分配系统中，用于控制灭火剂经管网释放到预定防护区或保护对象的阀门。",[189,191,193,195],{"key":20,"text":190,"correct":22},"排气阀",{"key":24,"text":192,"correct":22},"减压阀",{"key":28,"text":194,"correct":26},"选择阀",{"key":31,"text":196,"correct":22},"单向阀",{"id":198,"libraryId":5,"type":40,"typeLabel":41,"stem":199,"options":200,"answer":20,"analysis":37},936102,"气体灭火系统中将多个灭火剂瓶组的灭火剂汇集在一起，再分配到各防护区的部件是（ ）。",[201,203,205,207],{"key":20,"text":202,"correct":26},"集流管",{"key":24,"text":204,"correct":22},"连接管",{"key":28,"text":206,"correct":22},"虹吸管",{"key":31,"text":194,"correct":22},{"id":209,"libraryId":5,"type":40,"typeLabel":41,"stem":210,"options":211,"answer":28,"analysis":37},936103,"消防检查机构对某大楼内设备用房设置的管网式气体灭火系统进行检测，检测结果如下，其中不符合现行国家消防技术标准要求的是（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":22},"一套系统同时保护4个防护区",{"key":24,"text":215,"correct":22},"系统灭火剂的储量能满足最大的防护区的防护需要",{"key":28,"text":217,"correct":26},"手动与自动转换装置设在防护区内，中心点距地面高度为1．5m",{"key":31,"text":219,"correct":22},"手动控制装置设置在防护区外，中心点距地面高度为1．5m",{"id":221,"libraryId":5,"type":40,"typeLabel":41,"stem":222,"options":223,"answer":31,"analysis":37},936104,"某防护区采用高压二氧化碳气体灭火系统进行保护，该防护区灭火剂输送管道采用气压强度试验代替水压强度试验时，最小试验压力应为（ ）MPa。",[224,226,228,230],{"key":20,"text":225,"correct":22},"4",{"key":24,"text":227,"correct":22},"3．2",{"key":28,"text":229,"correct":22},"15",{"key":31,"text":231,"correct":26},"12",{"id":233,"libraryId":5,"type":40,"typeLabel":41,"stem":234,"options":235,"answer":20,"analysis":37},936105,"下列关于低压二氧化碳灭火系统中各组件设置,说法错误的是（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":26},"低压系统制冷装置的供电采用消防电源,采用手动控制",{"key":24,"text":239,"correct":22},"在容器阀和集流管之间的管道上设液流单向阀,方向与灭火剂输送方向应一致",{"key":28,"text":241,"correct":22},"在储存容器的容器阀和组合分配系统的集流管上设安全泄压装置",{"key":31,"text":243,"correct":22},"低压二氧化碳灭火系统的安全阀通过专用泄压管接到室外",{"id":245,"libraryId":5,"type":40,"typeLabel":41,"stem":246,"options":247,"answer":24,"analysis":37},936106,"对气体灭火系统进行模拟喷气试验,下列做法错误的是（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"IG541 混合气体灭火系统采用 IG541 混合气体,试验采用的储存容器数为防护区设计用量所需容器总数的 5%,且不少于 1 个",{"key":24,"text":251,"correct":26},"高压二氧化碳灭火系统,采用氮气进行模拟喷气试验,喷放量不小于设计用量的 5%",{"key":28,"text":253,"correct":22},"卤代烷灭火系统采用氮气,氮气储存容器数不少于灭火剂储存容器数的 20%,且不少于 1 个",{"key":31,"text":255,"correct":22},"采用自动启动方式,对所有防护区或保护对象进行模拟喷气试验",{"id":257,"libraryId":5,"type":40,"typeLabel":41,"stem":258,"options":259,"answer":28,"analysis":37},936107,"检漏装置用于检测瓶组内介质的压力或质量损失,对于低压二氧化碳气体灭火系统来说,灭火剂是否泄漏通常采用（ ）检查。",[260,262,264,266],{"key":20,"text":261,"correct":22},"压力计显示器",{"key":24,"text":263,"correct":22},"称重装置",{"key":28,"text":265,"correct":26},"液位测量装置",{"key":31,"text":267,"correct":22},"气体检漏仪",{"id":269,"libraryId":5,"type":40,"typeLabel":41,"stem":270,"options":271,"answer":24,"analysis":37},936108,"气体灭火系统中，五年后的维护保养工作是（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":22},"预制气溶胶灭火装置、自动干粉灭火装置有效期限检查",{"key":24,"text":275,"correct":26},"对释放过灭火剂的储瓶、相关阀门等部件进行一次水压强度和气体密封性试验",{"key":28,"text":277,"correct":22},"对每个防护区进行一次模拟自动喷气试验",{"key":31,"text":279,"correct":22},"连接管应无变形、裂纹及老化",{"id":281,"libraryId":5,"type":40,"typeLabel":41,"stem":282,"options":283,"answer":20,"analysis":37},936109,"下列关于气体灭火系统季度检查项目的叙述中，错误的是（ ）。",[284,286,288,290],{"key":20,"text":285,"correct":26},"气体灭火系统组件的安装位置不得有其他物件阻挡或妨碍其正常工作",{"key":24,"text":287,"correct":22},"可燃物的种类、分布情况，防护区的开口情况，应符合设计规定",{"key":28,"text":289,"correct":22},"储存装置间的设备、灭火剂输送管道和支架、吊架的固定，应无松动",{"key":31,"text":291,"correct":22},"各喷嘴孔口应无堵塞",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":306,"analysis":37},936110,"某场所设置在地下一层，平时无人，墙上设有可开启的外窗，场所内安装组合分配式二氧化碳气体灭火系统保护，并设有专用的储存容器间。下面是对该系统安装情况的检查结果，其中不符合规范要求的是（ ）。",[296,298,300,302,304],{"key":20,"text":297,"correct":22},"系统设有设置机械应急操作装置",{"key":24,"text":299,"correct":26},"每个防护区内安装一个选择阀",{"key":28,"text":301,"correct":22},"储存容器和集流管之间采用不锈钢软管连接",{"key":31,"text":303,"correct":26},"防护区的门能向疏散方向开启，并需要手动将门关闭",{"key":34,"text":305,"correct":26},"防护区内未设置机械排风装置","BDE",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":321,"analysis":37},936111,"某单位设安装的气体灭火系统安装调试完毕后，委托消防设施检测机构进行技术检测。关于气体灭火系统检测的下列说法中，错误的有（ ）。",[311,313,315,317,319],{"key":20,"text":312,"correct":26},"储存容器的规格和效量应符合设计文件要求，且同一系统的储存容器的规格、尺寸要一致，其高度差不应超过10mm",{"key":24,"text":314,"correct":22},"储存容器必须固定在支架上，操作面距墙或操作面之间的距离应不小于1.0m，且不小于储存容器外径的1.5倍",{"key":28,"text":316,"correct":26},"灭火剂储存容器的充装量和储存压力应符合设计文件，且不超过设计充装量的3%",{"key":31,"text":318,"correct":26},"容器阀和集流管之间采用刚性连接",{"key":34,"text":320,"correct":26},"储存容器中充装的二氧化碳质量损失大于15%时，二氧化碳灭火系统的检漏装置应正确报警","ACDE",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":321,"analysis":37},936112,"某防护区采用低压二氧化碳气体灭火系统进行保护，对该防护区灭火剂输送管道进行强度试压和气密性实验时，下列做法，符合规范要求的是（ ）。",[326,328,330,332,334],{"key":20,"text":327,"correct":26},"气压强度试验压力取3．2 MPa",{"key":24,"text":329,"correct":22},"气压强度试验时，按试验压力的5％逐级升压，每级稳压1min，直至试验压力",{"key":28,"text":331,"correct":26},"水压强度试验条件不具备，采用气压强度试验代替",{"key":31,"text":333,"correct":26},"气压强度试验前，用加压介质进行预试验，预试验压力取0．2MPa",{"key":34,"text":335,"correct":26},"气压强度试验合格后管道未拆卸过，可不进行气密性试验",{"id":337,"libraryId":5,"type":40,"typeLabel":41,"stem":338,"options":339,"answer":24,"analysis":37},936113,"根据现行国家标准《气体灭火系统施工及验收规范》GB 50263—2007，气动驱动装置储存容器内气体压力不应低于设计压力，且不得超过设计压力的（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"2％",{"key":24,"text":343,"correct":26},"5％",{"key":28,"text":345,"correct":22},"10％",{"key":31,"text":347,"correct":22},"12％",{"id":349,"libraryId":5,"type":40,"typeLabel":41,"stem":350,"options":351,"answer":28,"analysis":37},936114,"在组合分配式气体灭火系统中，当选择阀安装高度超过（ ）m时应采取便于操作的措施。",[352,354,356,358],{"key":20,"text":353,"correct":22},"1．2",{"key":24,"text":355,"correct":22},"1．5",{"key":28,"text":357,"correct":26},"1．7",{"key":31,"text":359,"correct":22},"2．2",{"id":361,"libraryId":5,"type":40,"typeLabel":41,"stem":362,"options":363,"answer":24,"analysis":37},936115,"下列关于气体灭火系统中气动驱动装置管道安装的说法，错误的是（ ）。",[364,366,368,370],{"key":20,"text":365,"correct":22},"气动驱动装置水平管道应采用管卡固定",{"key":24,"text":367,"correct":26},"气动驱动装置水平管道管卡的间距不宜大于0．8m",{"key":28,"text":369,"correct":22},"气动驱动装置竖直管道应在其始端和终端设防晃支架或采用管卡固定",{"key":31,"text":371,"correct":22},"气动驱动装置水平管道转弯处应增设1个管卡",{"id":373,"libraryId":5,"type":40,"typeLabel":41,"stem":374,"options":375,"answer":24,"analysis":37},936116,"IG541气体灭火系统通常采用（ ）检查灭火剂是否泄漏。",[376,377,378,379],{"key":20,"text":263,"correct":22},{"key":24,"text":261,"correct":26},{"key":28,"text":267,"correct":22},{"key":31,"text":265,"correct":22},{"id":381,"libraryId":5,"type":40,"typeLabel":41,"stem":382,"options":383,"answer":28,"analysis":37},936117,"消防技术服务机构对某文物资料库设置的气体灭火系统维护管理，下列选项中，属于年度检查项目的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":22},"喷嘴孔口有无堵塞",{"key":24,"text":387,"correct":22},"连接管有无变形",{"key":28,"text":389,"correct":26},"模拟启动试验",{"key":31,"text":391,"correct":22},"灭火器储存容器的内的压力",{"id":393,"libraryId":5,"type":40,"typeLabel":41,"stem":394,"options":395,"answer":20,"analysis":37},936118,"根据规定，储存容器中充装的二氧化碳质量损失大于（ ）时，二氧化碳灭火系统的检漏装置应正确报警。",[396,397,398,400],{"key":20,"text":345,"correct":26},{"key":24,"text":347,"correct":22},{"key":28,"text":399,"correct":22},"15％",{"key":31,"text":401,"correct":22},"20％",{"id":403,"libraryId":5,"type":40,"typeLabel":41,"stem":404,"options":405,"answer":24,"analysis":37},936119,"根据《气体灭火系统施工及验收规范》（GB 50263），安装气体灭火系统气动驱动装置的管道时，水平管道应采用管卡固定，管卡的间距不宜大于（ ）m，转弯处应增设1个管卡。",[406,408,410,412],{"key":20,"text":407,"correct":22},"0．5",{"key":24,"text":409,"correct":26},"0．6",{"key":28,"text":411,"correct":22},"0．7",{"key":31,"text":413,"correct":22},"0．8",{"id":415,"libraryId":5,"type":40,"typeLabel":41,"stem":416,"options":417,"answer":31,"analysis":37},936120,"开展七氟丙烷灭火系统模拟喷气试验时，宜采用（ ）进行试验。",[418,420,422,424],{"key":20,"text":419,"correct":22},"七氟丙烷",{"key":24,"text":421,"correct":22},"二氧化碳",{"key":28,"text":423,"correct":22},"氦气",{"key":31,"text":425,"correct":26},"氮气",{"id":427,"libraryId":5,"type":40,"typeLabel":41,"stem":428,"options":429,"answer":24,"analysis":37},936121,"对气体灭火系统的外观检查中，不符合要求的是（ ）。",[430,432,434,436],{"key":20,"text":431,"correct":22},"同一规格的灭火剂储存容器，其高度差为15 mm",{"key":24,"text":433,"correct":26},"同一规格的驱动气体储存容器，其高度差为15 mm",{"key":28,"text":435,"correct":22},"球阀或蝶阀结构的总控阀标有阀位指示标志（“开”和“关”或者“OPEN”和“CLOSE”），指示标志清晰易见",{"key":31,"text":437,"correct":22},"组件所有外露接口均设有防护堵盖，且封闭良好，接口螺纹和法兰密封面无损伤",{"id":439,"libraryId":5,"type":40,"typeLabel":41,"stem":440,"options":441,"answer":31,"analysis":37},936122,"某施工单位对新到场气体灭火系统灭火剂储存容器进行进场前检查，按照规定，检查的数量应为（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"到场数量的10％",{"key":24,"text":445,"correct":22},"到场数量的20％",{"key":28,"text":447,"correct":22},"到场数量的30％",{"key":31,"text":449,"correct":26},"全部",{"id":451,"libraryId":5,"type":40,"typeLabel":41,"stem":452,"options":453,"answer":20,"analysis":37},936123,"在对气体灭火系统阀驱动装置检查时，气动驱动装置储存容器内气体压力不应低于设计压力，且不得超过设计压力的（ ）。",[454,456,458,460],{"key":20,"text":455,"correct":26},"5%",{"key":24,"text":457,"correct":22},"7%",{"key":28,"text":459,"correct":22},"9%",{"key":31,"text":461,"correct":22},"10%",{"id":463,"libraryId":5,"type":40,"typeLabel":41,"stem":464,"options":465,"answer":24,"analysis":37},936124,"根据《气体灭火系统施工及验收规范》（GB 50263-2007），灭火剂输送管道穿越墙壁、楼板处要安装套管，套管公称直径比管道公称直径至少大（ ）级。",[466,468,470,472],{"key":20,"text":467,"correct":22},"1",{"key":24,"text":469,"correct":26},"2",{"key":28,"text":471,"correct":22},"3",{"key":31,"text":225,"correct":22},{"id":474,"libraryId":5,"type":40,"typeLabel":41,"stem":475,"options":476,"answer":28,"analysis":37},936125,"气体灭火系统的调试应在系统安装完毕，并宜在相关的火灾报警系统和开口自动关闭装置、通风机械和防火阀等联动设备的调试完成后进行，调试的项目不包括（ ）。",[477,478,480,482],{"key":20,"text":389,"correct":22},{"key":24,"text":479,"correct":22},"模拟喷气试验",{"key":28,"text":481,"correct":26},"模拟泄放试验",{"key":31,"text":483,"correct":22},"模拟切换操作试验",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":498,"analysis":37},936126,"下列关于气体灭火系统设备与输送管道验收的说法中，正确的是（ ）。",[488,490,492,494,496],{"key":20,"text":489,"correct":26},"灭火剂储存容器的数量、型号和规格应全数检查",{"key":24,"text":491,"correct":22},"称重检查按储存容器应全数检查",{"key":28,"text":493,"correct":22},"储存压力检查按储存容器按全数的20％检查",{"key":31,"text":495,"correct":26},"低压二氧化碳储存容器按全数检查",{"key":34,"text":497,"correct":26},"选择阀及信号反馈装置的数量、型号、规格、位置、标志及其安装质量应全数检查","ADE",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":513,"analysis":37},936127,"对气体灭火系统进行维护管理，下列属于气体灭火系统每月检查内容的是（ ）。",[503,505,507,509,511],{"key":20,"text":504,"correct":26},"高压二氧化碳灭火剂储存容器应无碰撞变形及其他机械性损伤",{"key":24,"text":506,"correct":26},"七氟丙烷管网灭火系统减压装置等全部系统组件应无碰撞变形及其他机械性损伤",{"key":28,"text":508,"correct":26},"高压二氧化碳灭火系统灭火剂和驱动气体储存容器内的压力，不得小于设计储存压力的90％",{"key":31,"text":510,"correct":22},"可燃物的种类、分布情况，防护区的开口情况检查",{"key":34,"text":512,"correct":22},"低压二氧化碳储存装置的运行情况、储存装置间的设备状态进行检查","ABC",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":528,"analysis":37},936128,"消防技术服务机构对某电视发射塔安装的IG541混合气体灭火系统进行验收前检测，在模拟启动试验环节，正确的检测方法有（ ）。",[518,520,522,524,526],{"key":20,"text":519,"correct":26},"手动模拟启动试验时，按下手动启动按钮，观察相关声光报警系统及启动输出端负载的动作信号、联动设备动作是否正常",{"key":24,"text":521,"correct":26},"手动模拟启动试验时，使压力信号反馈装置动作，观察相关防护区门外的气体喷放指示灯动作是否正常",{"key":28,"text":523,"correct":26},"自动模拟启动试验时，用人工模拟火警使防护区内的任意一个火灾探测器动作，观察单一火警信号输出后，相关报警设备动作是否正常；再用人工模拟火警使防护区内的另一火灾探测器动作，观察复合火警信号输出后，相关动作信号、联动设备动作是否正常",{"key":31,"text":525,"correct":26},"可用一个与灭火系统驱动装置启动电压、电流相同的负载代替灭火系统驱动装置进行模拟启动试验",{"key":34,"text":527,"correct":22},"手动模拟启动试验与自动模拟启动试验任选一项即可","ABCD",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":513,"analysis":37},936129,"气体灭火系统中应进行季度检查的项目包括（）。",[533,534,536,537,539],{"key":20,"text":287,"correct":26},{"key":24,"text":535,"correct":26},"储存装置间的设备、灭火剂输送管道和支、吊架的固定，应无松动",{"key":28,"text":291,"correct":26},{"key":31,"text":538,"correct":22},"驱动控制盘面板上的指示灯应正常，各开关位置应正确，各连线应无松动现象",{"key":34,"text":285,"correct":22},{"id":541,"libraryId":5,"type":40,"typeLabel":41,"stem":542,"options":543,"answer":24,"analysis":37},936130,"下列气体灭火系统的维护管理，属于季检项目的是（ ）。",[544,545,546,548],{"key":20,"text":285,"correct":22},{"key":24,"text":287,"correct":26},{"key":28,"text":547,"correct":22},"火灾探测器表面应保持清洁，应无任何会干扰或影响火灾探测器探测性能的擦伤、油渍及油漆",{"key":31,"text":538,"correct":22},{"id":550,"libraryId":5,"type":40,"typeLabel":41,"stem":551,"options":552,"answer":28,"analysis":37},936131,"在气体灭火系统中，高压储存装置的贮存容器必须固定在支架上，支架与建筑构件固定，要牢固可靠，并做防腐处理；操作面距墙或操作面之间的距离不宜小于1．0m，且不小于贮存容器外径的（ ）倍。",[553,555,556,557],{"key":20,"text":554,"correct":22},"1．0",{"key":24,"text":353,"correct":22},{"key":28,"text":355,"correct":26},{"key":31,"text":558,"correct":22},"1．8",{"id":560,"libraryId":5,"type":40,"typeLabel":41,"stem":561,"options":562,"answer":28,"analysis":37},936132,"消防技术服务机构的人员对某计算机房设置的组合分配式七氟丙烷气体灭火系统进行检查，检查结果如下，其中不符合现行国家消防技术标准的是（ ）。",[563,565,567,569],{"key":20,"text":564,"correct":22},"泄压口设置在防护区净高的3／4位置",{"key":24,"text":566,"correct":22},"系统采用氮气增压输送",{"key":28,"text":568,"correct":26},"气体驱动装置储存容器内的气体压力为设计压力的95％",{"key":31,"text":570,"correct":22},"储存容器的正面标有灭火剂的名称和容器的编号",{"id":572,"libraryId":5,"type":40,"typeLabel":41,"stem":573,"options":574,"answer":28,"analysis":37},936133,"下列关于气体灭火系统组件的说法中，正确的是（ ）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"灭火剂流通管路单向阀装于启动管路上，用来控制气体流动方向，启动特定的阀门",{"key":24,"text":578,"correct":22},"同一规格的灭火剂储存容器，其高度差不宜超过10mm",{"key":28,"text":580,"correct":26},"信号反馈装置可以将灭火剂的压力或流量信号转换为电信号，并反馈到控制中心",{"key":31,"text":582,"correct":22},"输送启动气体的管道宜采用不锈钢管",{"id":584,"libraryId":5,"type":40,"typeLabel":41,"stem":585,"options":586,"answer":20,"analysis":37},936134,"某档案室划分为4个防护区，设置组合式七氟丙烷气体灭火系统，系统施工结束后调试人员对该系统进行调试。下列有关调试的说法，正确的是（ ）。",[587,589,591,593],{"key":20,"text":588,"correct":26},"4个防护区都应进行模拟启动试验，并合格",{"key":24,"text":590,"correct":22},"只需随机选择一个防护区进行模拟启动试验，并合格",{"key":28,"text":592,"correct":22},"模拟启动试验可选择手动、自动或机械应急方式",{"key":31,"text":594,"correct":22},"模拟喷气试验宜采用手动启动方式",{"id":596,"libraryId":5,"type":40,"typeLabel":41,"stem":597,"options":598,"answer":24,"analysis":37},936135,"对安装完毕的气体灭火系统进行检查，检查结果如下，其中不符合相应规范要求的是（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"管道末端的防晃支架与末端喷嘴间的距离为30cm",{"key":24,"text":602,"correct":26},"穿楼板套管的长度高出楼板30mm",{"key":28,"text":604,"correct":22},"选择阀上有标明保护对象的永久性标志牌，并便于观察",{"key":31,"text":606,"correct":22},"气体喷放指示灯安装在防护区入口的正上方",{"id":608,"libraryId":5,"type":40,"typeLabel":41,"stem":609,"options":610,"answer":31,"analysis":37},936136,"某气体灭火系统储罐瓶内设有6只150L七氟丙烷灭火剂储存容器，根据《气体灭火系统施工及验收规范》（GB 50263），各储存容器的高度差最大不宜超过（ ）mm。",[611,613,614,615],{"key":20,"text":612,"correct":22},"10",{"key":24,"text":169,"correct":22},{"key":28,"text":93,"correct":22},{"key":31,"text":167,"correct":26},{"id":617,"libraryId":5,"type":40,"typeLabel":41,"stem":618,"options":619,"answer":20,"analysis":37},936137,"消防设施检查机构的人员对某通信机房内安装的组合分配式IG541气体灭火系统进行检查时发现下列问题，其中符合现行国家消防技术标准的是（ ）。",[620,622,624,626],{"key":20,"text":621,"correct":26},"储存容器瓶采用无缝容器",{"key":24,"text":623,"correct":22},"喷头安装在梁下，距顶板的距离为0．8m",{"key":28,"text":625,"correct":22},"为了使喷头喷洒的均应，在防护区内采用了四通管道进行分流",{"key":31,"text":627,"correct":22},"机械应急装置设置在防护区内靠近保护对象的地方",[629,632,635,638,641,644],{"id":40,"name":630,"category":7,"favorite":631},"领导干部任职前廉政法规知识测试题",92,{"id":633,"name":634,"category":7,"favorite":40},595,"建筑结构与设备",{"id":636,"name":637,"category":7,"favorite":40},715,"招标采购专业知识与法律法规",{"id":639,"name":640,"category":7,"favorite":40},848,"市政方向-通用基础",{"id":642,"name":643,"category":7,"favorite":8},534,"BIM工程师",{"id":645,"name":643,"category":7,"favorite":8},535]