[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":645},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,28,50,2974,[13,34,46,58,76,90,105,120,135,147,159,171,183,195,207,219,231,243,255,267,282,297,311,322,334,346,361,372,384,396,406,418,430,445,460,469,477,489,498,513,523,535,544,556,568,580,592,604,616,631],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},936038,1,"单选题","下列属于扩大覆盖面积洒水喷头的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","流量系数K=80的直立型喷头，保护面积为15m2",false,{"key":24,"text":25,"correct":26},"B","流量系数K=80的下垂型喷头，保护面积为22m2",true,{"key":28,"text":29,"correct":22},"C","流量系数K=115的边墙型喷头，保护面积为18m2",{"key":31,"text":32,"correct":22},"D","流量系数K=115的直立型喷头，保护面积为37m2","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},936039,"下列关于水泵接合器的说法中，不正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"建筑高度为 32m 的公共建筑应设置水泵接合器",{"key":24,"text":41,"correct":22},"建筑高度为 33m 的住宅建筑应设置水泵接合器",{"key":28,"text":43,"correct":26},"建筑层数为 4 层层高为 5m 的丁类厂房应设置水泵接合器",{"key":31,"text":45,"correct":22},"建筑层数为 5 层层高为 5m 的丙类厂房应设置水泵接合器",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},936040,"环境温度低于 4℃的北方城市经常采用干式系统作为扑救初期火灾的有效措施。下列关于干式报警阀组的安装,不符合要求的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"在靠近报警阀的位置安装加速器,设有防止水流进入加速器的措施",{"key":24,"text":53,"correct":22},"报警阀组充气一侧设有压力表、安全排气阀",{"key":28,"text":55,"correct":26},"充气连接管路的接口安装在报警阀气室充注水位以下部位,充气连接管道采用直径 15mm,设有止回阀、截止阀",{"key":31,"text":57,"correct":22},"报警阀组安装完成后,向气室注入高度为 50~100mm 的清水",{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":75,"analysis":33},936041,2,"多选题","下列符合干式报警阀组安装要求的是（）。",[64,66,68,70,72],{"key":20,"text":65,"correct":26},"安装在不发生冰冻的场所",{"key":24,"text":67,"correct":26},"安装完成后，向报警阀气室注入高度为50～100mm的清水",{"key":28,"text":69,"correct":22},"止回阀、截止阀安装在排气连接管路上",{"key":31,"text":71,"correct":26},"安全排气阀安装在气源与报警阀组之间，靠近报警阀组一侧",{"key":73,"text":74,"correct":26},"E","加速器安装在靠近报警阀的位置，设有防止水流进入加速器的措施","ABDE",{"id":77,"libraryId":5,"type":60,"typeLabel":61,"stem":78,"options":79,"answer":75,"analysis":33},936042,"自动喷水灭火系统竣工后，建设单位组织实施工程竣工验收。下列属于系统验收时，施工单位应提供的资料有（ ）。",[80,82,84,86,88],{"key":20,"text":81,"correct":26},"施工现场质量管理检查记录",{"key":24,"text":83,"correct":26},"工程质量事故处理报告",{"key":28,"text":85,"correct":22},"立项批准文件",{"key":31,"text":87,"correct":26},"质量控制检查资料",{"key":73,"text":89,"correct":26},"施工过程质量管理检查记录",{"id":91,"libraryId":5,"type":60,"typeLabel":61,"stem":92,"options":93,"answer":104,"analysis":33},936043,"对自动喷水灭火系统实施检查维护，下列项目中，属于每月检查内容的有（ ）。",[94,96,98,100,102],{"key":20,"text":95,"correct":26},"报警阀启动性能测试",{"key":24,"text":97,"correct":26},"消防水泵接合器完好性检查",{"key":28,"text":99,"correct":26},"喷头的完好状况、备用量",{"key":31,"text":101,"correct":22},"水源供水能力测试",{"key":73,"text":103,"correct":22},"报警阀旁的放水试验阀进行测试","ABC",{"id":106,"libraryId":5,"type":60,"typeLabel":61,"stem":107,"options":108,"answer":119,"analysis":33},936044,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，对自动喷水灭火系统的报警阀组进行验收，下列报警阀组动作的说法，正确的是（ ）。",[109,111,113,115,117],{"key":20,"text":110,"correct":26},"雨淋报警阀动作后15s内压力开关应动作",{"key":24,"text":112,"correct":22},"雨淋报警阀动作后60s内压力开关应动作",{"key":28,"text":114,"correct":22},"打开末端试（放）水装置，当流量达到报警阀动作流量时，湿式报警阀和压力开关应及时动作，不带延迟器的报警阀应在60s内压力开关动作",{"key":31,"text":116,"correct":26},"测试水力警铃时，水力警铃喷嘴处压力不应小于0．05MPa",{"key":73,"text":118,"correct":26},"打开末端试（放）水装置，当流量达到报警阀动作流量时，湿式报警阀不带延迟器的报警阀应在15 s内压力开关动作","ADE",{"id":121,"libraryId":5,"type":60,"typeLabel":61,"stem":122,"options":123,"answer":134,"analysis":33},936045,"对自动喷水灭火系统的报警阀组进行检查，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于报警阀组的安装要求的说法中，正确的是（ ）。",[124,126,128,130,132],{"key":20,"text":125,"correct":22},"干式报警阀的安全排气阀应安装在气源与报警阀之间，且应靠近气源",{"key":24,"text":127,"correct":26},"湿式报警阀报警水流通路上的过滤器应安装在延迟器前，且便于排渣操作的位置",{"key":28,"text":129,"correct":26},"干式报警阀安装完成后，应向报警阀气室注入高度为50mm～100mm的清水",{"key":31,"text":131,"correct":26},"水源控制阀安装应便于操作，且应有明显开闭标志和可靠的锁定设施",{"key":73,"text":133,"correct":22},"干式报警阀的低气压预报警装置应安装在供水干管一侧","BCD",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":28,"analysis":33},936046,"消防水源的维护管理要求，应（ ）对消防水池、高位消防水池、高位消防水箱等消防水源设施的水位进行一次检测。",[139,141,143,145],{"key":20,"text":140,"correct":22},"每日",{"key":24,"text":142,"correct":22},"每周",{"key":28,"text":144,"correct":26},"每月",{"key":31,"text":146,"correct":22},"每季度",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":31,"analysis":33},936047,"水喷雾灭火系统运行周期性维护管理中，下列检查项目中属于每月检查项目的是（ ）。",[151,153,155,157],{"key":20,"text":152,"correct":22},"消防水泵和备用动力进行启动试验",{"key":24,"text":154,"correct":22},"检查系统启动、报警功能以及出水情况是否正常",{"key":28,"text":156,"correct":22},"室外阀门井中进水管上的控制阀门，核实其处于全开启状态",{"key":31,"text":158,"correct":26},"检查保证消防用水不作他用的技术措施，发现故障应及时进行处理",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":28,"analysis":33},936048,"某消防工程施工单位以自动方式对水喷雾灭火系统进行联动试验。下列试验次数最少且符合现行国家标准要求的是（ ）。",[163,165,167,169],{"key":20,"text":164,"correct":22},"自动1次、手动2次",{"key":24,"text":166,"correct":22},"自动2次、手动2次",{"key":28,"text":168,"correct":26},"自动1次、手动1次",{"key":31,"text":170,"correct":22},"自动2次、手动3次",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":31,"analysis":33},936049,"下列关于水喷雾灭火系统冲洗时排水管道设计的说法中，正确的是（ ）。",[175,177,179,181],{"key":20,"text":176,"correct":22},"排水管道的管径不得小于被冲洗管道管径的60％",{"key":24,"text":178,"correct":22},"排水管道的管径不得小于被冲洗管道管径",{"key":28,"text":180,"correct":22},"排水管道的截面面积不得小于被冲洗管道截面面积",{"key":31,"text":182,"correct":26},"排水管道的截面面积不得小于被冲洗管道截面面积的60％",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":20,"analysis":33},936050,"水喷雾灭火系统检测验收时，按照规定，应检查报警阀安装地点的常年温度不小于（ ）℃。",[187,189,191,193],{"key":20,"text":188,"correct":26},"4",{"key":24,"text":190,"correct":22},"5",{"key":28,"text":192,"correct":22},"7",{"key":31,"text":194,"correct":22},"9",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":28,"analysis":33},936051,"水喷雾灭火系统管道安装完毕后应进行水压试验，试验压力应为设计压力的1．5倍，稳压（ ）min，管道无损坏、变形，再将试验压力降至设计压力，稳压（ ）min。",[199,201,203,205],{"key":20,"text":200,"correct":22},"5，10",{"key":24,"text":202,"correct":22},"10，20",{"key":28,"text":204,"correct":26},"10，30",{"key":31,"text":206,"correct":22},"5，30",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":28,"analysis":33},936052,"水喷雾灭火系统工程质量缺陷分为严重缺陷项 （A）、重要缺陷项 （B）和轻微缺陷项 （C），对某工程质量验收的结果如下，其中合格的是（ ）。",[211,213,215,217],{"key":20,"text":212,"correct":22},"A=1．且B=3，且C=4",{"key":24,"text":214,"correct":22},"A=1，且B=0，且C=1",{"key":28,"text":216,"correct":26},"A=0，且B=1，且C=4",{"key":31,"text":218,"correct":22},"A=0，且B=3，且C=2",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":31,"analysis":33},936053,"下列关于水喷雾灭火系统喷头安装的说法中，错误的是（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":22},"喷头的规格、型号应符合设计要求，并应在系统试压、冲洗、吹扫合格后进行安装",{"key":24,"text":226,"correct":22},"喷头应安装牢固、规整，安装时不得拆卸或损坏喷头上的附件",{"key":28,"text":228,"correct":22},"侧向安装的喷头应安装在被保护物体的侧面并应对准被保护物体，其距离偏差不应大于20mm",{"key":31,"text":230,"correct":26},"顶部设置的喷头应安装在被保护物的上部，室外安装坐标偏差不应大于10mm，室内安装坐标偏差不应大于20mm",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":31,"analysis":33},936054,"某建设单位对建筑内水喷雾灭火系统报警阀组进行竣工验收，水力警铃喷嘴处压力大于0．05MPa时，在距水力警铃3m处检测警铃声强，测得的水力警铃声强级符合规定的是（ ）。",[235,237,239,241],{"key":20,"text":236,"correct":22},"50dB",{"key":24,"text":238,"correct":22},"60dB",{"key":28,"text":240,"correct":22},"65dB",{"key":31,"text":242,"correct":26},"75dB",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":28,"analysis":33},936055,"在水喷雾灭火系统报警阀组的安装过程中，不符合国家工程消防技术标准的做法是（ ）。",[247,249,251,253],{"key":20,"text":248,"correct":22},"安装位置靠近保护对象附近，并便于操作",{"key":24,"text":250,"correct":22},"距室内地面高度为1．2 m，两侧与墙的距离为0．6 m，正面与墙的距离为1．2m",{"key":28,"text":252,"correct":26},"报警阀组凸出部位之间的距离为0．4 m",{"key":31,"text":254,"correct":22},"安装报警阀组的室内地面设有排水设施",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":28,"analysis":33},936056,"水喷雾灭火系统管道试压合格后，宜用清水冲洗，流速不低于（ ）m／s。",[259,261,263,265],{"key":20,"text":260,"correct":22},"1",{"key":24,"text":262,"correct":22},"2",{"key":28,"text":264,"correct":26},"1．5",{"key":31,"text":266,"correct":22},"2．5",{"id":268,"libraryId":5,"type":60,"typeLabel":61,"stem":269,"options":270,"answer":281,"analysis":33},936057,"下列关于水喷雾灭火系统管网冲洗的说法中，正确的有（ ）。",[271,273,275,277,279],{"key":20,"text":272,"correct":22},"管网冲洗的水流流速、流量应小于系统设计的水流流速、流量",{"key":24,"text":274,"correct":26},"水平管网冲洗时，其排水管位置应低于配水支管",{"key":28,"text":276,"correct":22},"管网冲洗的水流方向应与灭火时管网的水流相反",{"key":31,"text":278,"correct":26},"管网冲洗应连续进行，当出口处水的颜色、透明度与入口处水的颜色、透明度基本一致时，冲洗方可结束",{"key":73,"text":280,"correct":22},"管网冲洗结束后，应将管网内的水排除干净，必要时可采用二氧化碳吹干","BD",{"id":283,"libraryId":5,"type":60,"typeLabel":61,"stem":284,"options":285,"answer":296,"analysis":33},936058,"下列关于水喷雾灭火系统维护管理的说法中，正确的有（ ）。",[286,288,290,292,294],{"key":20,"text":287,"correct":26},"维护管理人员应经过消防专业培训",{"key":24,"text":289,"correct":26},"每周应对消防水泵和备用动力进行一次启动试验",{"key":28,"text":291,"correct":22},"钢板消防水箱的玻璃水位计两端的角阀平时应保持开启状态",{"key":31,"text":293,"correct":22},"每季度应对系统水源的供水能力进行一次测定",{"key":73,"text":295,"correct":22},"系统发生故障时可以直接停水进行维修","AB",{"id":298,"libraryId":5,"type":60,"typeLabel":61,"stem":299,"options":300,"answer":281,"analysis":33},936059,"下列关于水喷雾灭火系统中减压阀安装的说法中，错误的是（ ）。",[301,303,305,307,309],{"key":20,"text":302,"correct":22},"减压阀的安装应在供水管网试压、冲洗合格后进行",{"key":24,"text":304,"correct":26},"可调式减压阀宜水平安装，阀盖应朝向侧面",{"key":28,"text":306,"correct":22},"比例式减压阀宜垂直安装",{"key":31,"text":308,"correct":26},"应在减压阀出水侧安装过滤器",{"key":73,"text":310,"correct":22},"安装自身不带压力表的减压阀时，应在其前后相邻部位安装压力表",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":28,"analysis":33},936060,"某公共建筑内设置的水喷雾灭火系统实际安装了500只喷头，系统安装的喷头均为同一种型号，对系统的喷头进行验收，其喷头的备用量不应少于（ ）只。",[315,317,319,320],{"key":20,"text":316,"correct":22},"50",{"key":24,"text":318,"correct":22},"10",{"key":28,"text":190,"correct":26},{"key":31,"text":321,"correct":22},"40",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},936061,"某消防技术服务机构应某企业要求，对企业所在大楼安装自动喷水灭火系统。下列有关报警阀组的安装顺序，描述正确的是（）。",[326,328,330,332],{"key":20,"text":327,"correct":26},"先安装水源控制阀、报警阀，然后进行报警阀辅助管道的连接，水源控制阀、报警阀与配水干管的连接",{"key":24,"text":329,"correct":22},"先进行报警阀辅助管道的连接，水源控制阀、报警阀与配水干管的连接，然后安装水源控制阀、报警阀",{"key":28,"text":331,"correct":22},"先安装水源控制阀，然后进行报警阀辅助管道的连接，再安装报警阀，最后进行水源控制阀、报警阀与配水干管的连接",{"key":31,"text":333,"correct":22},"先进行水源控制阀、报警阀与配水干管的连接，再安装水源控制阀、报警阀，最后再进行报警阀辅助管道的连接",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},936062,"下列关于水喷雾灭火系统的说法，不符合规范要求的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":22},"《水喷雾灭火系统技术规范》（GB50219—2014）不适用于移动式水喷雾灭火装置或交通运输工具中设置的水喷雾灭火系统",{"key":24,"text":341,"correct":26},"用于扑灭饮料酒火灾水喷雾灭火系统的响应时间不应大于40s",{"key":28,"text":343,"correct":22},"用于柴油储罐的防护冷却时，水喷雾喷头的工作压力不应小于0．15MPa",{"key":31,"text":345,"correct":22},"水喷雾灭火系统用于保护液化烃储罐上环管支架之间的距离宜为3～3．5m",{"id":347,"libraryId":5,"type":60,"typeLabel":61,"stem":348,"options":349,"answer":360,"analysis":33},936063,"下列关于水喷雾灭火系统喷头外观检查的说法，正确的是（ ）。",[350,352,354,356,358],{"key":20,"text":351,"correct":26},"商标、型号、制造厂及生产日期等标志齐全",{"key":24,"text":353,"correct":26},"喷头的型号、规格等符合设计要求",{"key":28,"text":355,"correct":26},"喷头外观无加工缺陷和机械损伤",{"key":31,"text":357,"correct":26},"喷头螺纹密封面应无伤痕、飞边、缺丝或断丝现象",{"key":73,"text":359,"correct":22},"应有水流方向的永久性标志","ABCD",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},936064,"下列关于喷头安装前检查的说法中，错误的是（ ）。",[365,367,368,370],{"key":20,"text":366,"correct":22},"喷头商标、型号、制造厂及生产日期等标志齐全",{"key":24,"text":353,"correct":22},{"key":28,"text":369,"correct":26},"喷头外观可以适当有加工缺陷和机械损伤",{"key":31,"text":371,"correct":22},"喷头螺纹密封面应无伤痕、毛刺、缺丝或断丝现象",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":31,"analysis":33},936065,"水喷雾灭火系统的阀门在进场检验时应进行强度和严密性试验，其中强度试验压力应为公称压力的（ ）倍，严密性试验压力应为公称压力的（ ）倍。",[376,378,380,382],{"key":20,"text":377,"correct":22},"1．2，1．1",{"key":24,"text":379,"correct":22},"1．5，1．2",{"key":28,"text":381,"correct":22},"1．2，1．0",{"key":31,"text":383,"correct":26},"1．5，1．1",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":20,"analysis":33},936066,"水喷雾灭火系统管道安装时，管道支、吊架与水雾喷头之间的距离不应小于（ ）m。",[388,390,392,394],{"key":20,"text":389,"correct":26},"0．3",{"key":24,"text":391,"correct":22},"0．5",{"key":28,"text":393,"correct":22},"0．8",{"key":31,"text":395,"correct":22},"1．2",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":24,"analysis":33},936067,"根据现行国家标准《水喷雾灭火系统技术规范》GB 50219—2014，对水喷雾灭火系统进行验收时，应在现场对喷头安装间距进行抽查，应抽查设计喷头数量的（ ）％，总数不少于（ ）个。",[400,401,403,404],{"key":20,"text":200,"correct":22},{"key":24,"text":402,"correct":26},"5，20",{"key":28,"text":202,"correct":22},{"key":31,"text":405,"correct":22},"10，40",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},936068,"下列关于水喷雾灭火系统联动试验的说法，错误的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"采用模拟火灾信号启动系统，相应的分区雨淋报警阀（或电动控制阀、气动控制阀）、压力开关和消防水泵及其他联动设备均应能及时动作并发出相应的信号",{"key":24,"text":413,"correct":26},"当为手动控制时，以手动方式进行1次一2次试验，当为自动控制时，以自动方式进行1次～2次试验",{"key":28,"text":415,"correct":22},"采用传动管启动的系统，启动1只喷头，相应的分区雨淋报警阀、压力开关和消防水泵及其他联动设备均应能及时动作并发出相应的信号",{"key":31,"text":417,"correct":22},"系统的响应时间、工作压力和流量应符合设计要求",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":28,"analysis":33},936069,"下列关于自动喷水灭火系统报警阀组安装要求的说法中，不符合现行国家消防技术标准的是（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":22},"报警阀组的安装应在供水管网试压、冲洗合格后进行",{"key":24,"text":425,"correct":22},"报警阀组的安装顺序应为水源控制阀、报警阀、报警阀辅助管道",{"key":28,"text":427,"correct":26},"当设计无要求时，报警阀组应安装在便于操作的明显位置，距室内地面高度宜为0.7m",{"key":31,"text":429,"correct":22},"安装报警阀组的室内地面应有排水设施",{"id":431,"libraryId":5,"type":60,"typeLabel":61,"stem":432,"options":433,"answer":444,"analysis":33},936070,"下列关于水喷雾灭火系统调试方法的说法中，正确的有（ ）。",[434,436,438,440,442],{"key":20,"text":435,"correct":22},"报警阀调试应采用工作管道进行",{"key":24,"text":437,"correct":22},"自动和手动方式启动的雨淋阀，应在30s之内启动",{"key":28,"text":439,"correct":26},"公称直径大于200mm的报警阀调试时，应在60s之内启动",{"key":31,"text":441,"correct":26},"报警阀调试时，当报警水压为0．05MPa，水力警铃应发出报警铃声",{"key":73,"text":443,"correct":26},"调试过程中，系统排出的水应通过排水设施全部排走","CDE",{"id":446,"libraryId":5,"type":60,"typeLabel":61,"stem":447,"options":448,"answer":459,"analysis":33},936071,"下列属于水喷雾灭火系统月度检查项目的有（ ）。",[449,451,453,455,457],{"key":20,"text":450,"correct":26},"电磁阀的启动测试",{"key":24,"text":452,"correct":22},"消防水泵自动控制启动测试",{"key":28,"text":454,"correct":22},"水源控制阀外观检查",{"key":31,"text":456,"correct":26},"手动控制阀门的铅封、锁链检查",{"key":73,"text":458,"correct":22},"系统放水测试","AD",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},936072,"某细水雾灭火系统施工工地新到一批细水雾喷头，数量共计180只，按照规范要求，施工单位应至少抽取（ ）只进行检查。",[464,465,466,467],{"key":20,"text":262,"correct":22},{"key":24,"text":190,"correct":26},{"key":28,"text":318,"correct":22},{"key":31,"text":468,"correct":22},"18",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":33},936073,"施工单位对某批型号规格相同的320只的细水雾喷头做进场检验，根据现行国家标准《细水雾灭火系统技术规范》GB 50898，该批喷头应至少抽查（ ）只。",[473,474,475,476],{"key":20,"text":188,"correct":22},{"key":24,"text":190,"correct":26},{"key":28,"text":192,"correct":22},{"key":31,"text":318,"correct":22},{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":24,"analysis":33},936074,"下列关于泵组式供细水雾灭火系统水装置的说法，不正确的是（ ）。",[481,483,485,487],{"key":20,"text":482,"correct":22},"泵组系统的供水装置宜由储水箱、水泵、水泵控制柜（盘）、安全阀等部件组成",{"key":24,"text":484,"correct":26},"水泵控制柜（盘）的防护等级不应低于IP55",{"key":28,"text":486,"correct":22},"安全阀的动作压力应为系统最大工作压力的1．15倍",{"key":31,"text":488,"correct":22},"水泵应具有自动和手动启动功能以及巡检功能",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":24,"analysis":33},936075,"某一层建筑，建筑面积 2000 ㎡，高 4m，采用全淹没应用方式的开式细水雾灭火系统，设置泵组系统供水，该建筑宜设置（ ）个防护区。",[493,494,496,497],{"key":20,"text":262,"correct":22},{"key":24,"text":495,"correct":26},"3",{"key":28,"text":188,"correct":22},{"key":31,"text":190,"correct":22},{"id":499,"libraryId":5,"type":60,"typeLabel":61,"stem":500,"options":501,"answer":512,"analysis":33},936076,"细水雾灭火系统泵组常见故障有（ ）。",[502,504,506,508,510],{"key":20,"text":503,"correct":26},"泵组连接处有渗漏",{"key":24,"text":505,"correct":26},"泵组出口压力低",{"key":28,"text":507,"correct":26},"泵组不启动",{"key":31,"text":509,"correct":22},"稳压泵不能频繁启动",{"key":73,"text":511,"correct":26},"稳压泵规定时间内不能恢复压力","ABCE",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":31,"analysis":33},936077,"根据现行国家标准《细水雾灭火系统技术规范》GB 50898—2013的规定，对细水雾灭火系统管网进行吹扫时，流速不宜小于（ ）m／s。",[517,518,519,521],{"key":20,"text":190,"correct":22},{"key":24,"text":318,"correct":22},{"key":28,"text":520,"correct":22},"15",{"key":31,"text":522,"correct":26},"20",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":28,"analysis":33},936078,"细水雾灭火系统管道冲洗合格后，应进行压力试验，按照规范，下列说法正确的是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"当压力升至试验压力后，稳压2min，管道无损坏、变形，再将试验压力降至设计压力，稳压60min",{"key":24,"text":530,"correct":22},"当压力升至试验压力后，稳压2min，管道无损坏、变形，再将试验压力降至设计压力，稳压120min",{"key":28,"text":532,"correct":26},"当压力升至试验压力后，稳压5min，管道无损坏、变形，再将试验压力降至设计压力，稳压120min",{"key":31,"text":534,"correct":22},"当压力升至试验压力后，稳压5min，管道无损坏、变形，再将试验压力降至设计压力，稳压60min",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":28,"analysis":33},936079,"某施工单位对工地800只同型号细水雾喷头进行安装前检查，按照规范要求，最少抽取（ ）只进行检查。",[539,540,541,543],{"key":20,"text":495,"correct":22},{"key":24,"text":190,"correct":22},{"key":28,"text":542,"correct":26},"8",{"key":31,"text":318,"correct":22},{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":28,"analysis":33},936080,"下列关于细水雾灭火系统泵组安装的说法中，错误的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"泵组的安装应符合现行国家标准《机械设备安装工程施工及验收通用规范》GB 50231的有关规定",{"key":24,"text":551,"correct":22},"泵组的安装除应符合现行国家标准《风机、压缩机、泵安装工程施工及验收规范》GB 50275的有关规定",{"key":28,"text":553,"correct":26},"系统采用柱塞泵时，泵组安装前应充装润滑油并检查油位",{"key":31,"text":555,"correct":22},"泵组吸水管上的变径处应采用偏心大小头连接",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":28,"analysis":33},936081,"双流体细水雾灭火系统气体管道的试验压力为水压强度试验压力的（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"20％",{"key":24,"text":563,"correct":22},"60％",{"key":28,"text":565,"correct":26},"80％",{"key":31,"text":567,"correct":22},"90％",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":28,"analysis":33},936082,"下列关于细水雾灭火系统维护管理的说法中，错误的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"系统的维护管理应由经过培训的人员承担",{"key":24,"text":575,"correct":22},"维护管理人员应熟悉系统的工作原理和操作维护方法与要求",{"key":28,"text":577,"correct":26},"系统发生故障并需停用进行维修时，应经消防管理人批准后进行",{"key":31,"text":579,"correct":22},"当改变建筑物的用途或几何特征或可燃物特性等可能影响系统的灭火有效性时，应对系统进行校核或重新设计",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":24,"analysis":33},936083,"对细水雾灭火系统进行水压试验时，不符合要求的做法是（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"环境温度不低于5℃，当低于5℃时，采取防冻措施，以确保水压试验正常进行",{"key":24,"text":587,"correct":26},"试验压力为系统工作压力的1．2倍",{"key":28,"text":589,"correct":22},"试验用水的水质与管道的冲洗水一致",{"key":31,"text":591,"correct":22},"试验用水中氯离子含量不超过25 mg／kg",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":20,"analysis":33},936084,"下列有关细水雾灭火系统分区控制阀安装要求的说法，不正确的是（ ）。",[596,598,600,602],{"key":20,"text":597,"correct":26},"分区控制阀的安装高度宜为0．8m～1．2m",{"key":24,"text":599,"correct":22},"分区控制阀应有明显启闭标志和可靠的锁定设施",{"key":28,"text":601,"correct":22},"分区控制阀应具有启闭状态的信号反馈功能",{"key":31,"text":603,"correct":22},"分区控制阀操作面与墙的距离不应小于0．8m",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":20,"analysis":33},936085,"某消防检测服务机构对图书库内细水雾灭火系统进行日常维护管理，根据《细水雾灭火系统技术规范》GB 50898—2013，下列属于季度检查项目的是（ ）。",[608,610,612,614],{"key":20,"text":609,"correct":26},"瓶组系统的控制阀动作检查",{"key":24,"text":611,"correct":22},"系统模拟联动功能试验",{"key":28,"text":613,"correct":22},"手动操作装置的保护罩完好情况检查",{"key":31,"text":615,"correct":22},"系统的主备电源接通情况检查",{"id":617,"libraryId":5,"type":60,"typeLabel":61,"stem":618,"options":619,"answer":630,"analysis":33},936086,"细水雾灭火系统压力试验合格后，系统管道宜采用（ ）进行吹扫。",[620,622,624,626,628],{"key":20,"text":621,"correct":22},"水",{"key":24,"text":623,"correct":22},"二氧化碳",{"key":28,"text":625,"correct":26},"压缩空气",{"key":31,"text":627,"correct":26},"氮气",{"key":73,"text":629,"correct":22},"氩气","CD",{"id":632,"libraryId":5,"type":60,"typeLabel":61,"stem":633,"options":634,"answer":296,"analysis":33},936087,"细水雾灭火系统进行维护管理时，下列属于月度检查项目的是（ ）。",[635,637,639,641,643],{"key":20,"text":636,"correct":26},"系统外观检查",{"key":24,"text":638,"correct":26},"喷头的备用数量",{"key":28,"text":640,"correct":22},"通过泄放试验阀对泵组系统进行放水测试",{"key":31,"text":642,"correct":22},"水泵控制柜的控制面板及显示信号状态",{"key":73,"text":644,"correct":22},"控制阀等各种阀门的外观检查",[646,649,652,655,658,661],{"id":15,"name":647,"category":7,"favorite":648},"领导干部任职前廉政法规知识测试题",92,{"id":650,"name":651,"category":7,"favorite":15},595,"建筑结构与设备",{"id":653,"name":654,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":656,"name":657,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":659,"name":660,"category":7,"favorite":8},534,"BIM工程师",{"id":662,"name":660,"category":7,"favorite":8},535]