[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":642},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,27,50,2974,[13,34,46,58,70,82,94,106,118,130,142,160,175,189,203,217,232,247,262,277,289,301,313,325,340,352,365,376,388,400,412,424,436,448,460,470,482,492,504,516,525,537,549,561,573,585,597,609,618,630],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},935987,1,"单选题","某单位自动喷水系统竣工后，建设单位进行工程验收，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017要求，系统管网组件验收时，需要全数检查的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","水流指示器",false,{"key":24,"text":25,"correct":22},"B","信号阀",{"key":27,"text":28,"correct":29},"C","减压阀",true,{"key":31,"text":32,"correct":22},"D","减压孔板","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},935988,"某消防技术服务机构对某单位设置的自动喷水灭火系统进行年度检测时发现，打开末端试水装置，达到规定的流量时水流指示器动作并发出信号，报警阀打开，压力开关正常动作，但水力警铃不响。对出现这种故障的原因进行分析，则原因最有可能是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"报警管路延迟器堵塞",{"key":24,"text":41,"correct":29},"水力警铃铃锤被卡住",{"key":27,"text":43,"correct":22},"报警管路堵塞",{"key":31,"text":45,"correct":22},"报警阀漏水",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},935989,"某消防设施检测机构的人员对一宾馆设置的湿式自动喷水灭火系统进行检测，打开测试阀，发现消防水泵不能正常启动，下列有关不能启动的原因分析中，不正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"高位消防水箱流量开关设定值不正确",{"key":24,"text":53,"correct":22},"消防水泵控制柜未打在“自动”状态",{"key":27,"text":55,"correct":22},"报警阀组压力开关设置不正确",{"key":31,"text":57,"correct":29},"消防联动控制器未打在“自动”状态",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},935990,"消防维保单位根据合同对某商场设置的自动喷水灭火系统进行维护管理，打开末端试水装置，水流指示器没有动作但报警阀组压力开关及时动作并发出了启泵信号，出现此种现象的原因不可能是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"水流指示器桨片被杂物卡阻",{"key":24,"text":65,"correct":29},"没有达到规定的放水流量",{"key":27,"text":67,"correct":22},"水流指示器与消防联动控制器之间的电路接线脱落",{"key":31,"text":69,"correct":22},"水流指示器的调整螺母与触头未调试到位",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},935991,"下列有关水力警铃验收测试时的说法，正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"水力警铃喷嘴处压力不应小于0．05MPa，且距水力警铃2m远处警铃声声强不应小于65dB",{"key":24,"text":77,"correct":29},"水力警铃喷嘴处压力不应小于0．05MPa，且距水力警铃3m远处警铃声声强不应小于70dB",{"key":27,"text":79,"correct":22},"水力警铃喷嘴处压力不小于0．1MPa，且距水力警铃3m远处警铃声声强不应小于70dB",{"key":31,"text":81,"correct":22},"水力警铃喷嘴处压力不大于0．1MPa，且距水力警铃2m远处警铃声声强不应小于65dB",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},935992,"自动喷水灭火系统中，末端试水装置应每（ ）进行一次放水试验。",[86,88,90,92],{"key":20,"text":87,"correct":22},"日",{"key":24,"text":89,"correct":22},"月",{"key":27,"text":91,"correct":29},"季度",{"key":31,"text":93,"correct":22},"年",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},935993,"根据《自动喷水灭火系统施工及验收规范》GB 50261—2017的要求，对自动喷水灭火系统进行竣工验收。下列不属于喷头验收内容的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":29},"喷头安装是否美观",{"key":24,"text":101,"correct":22},"喷头是否采取防护措施",{"key":27,"text":103,"correct":22},"喷头的安装间距",{"key":31,"text":105,"correct":22},"喷头是否有备品",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},935994,"消防技术服务机构对委托单位的自动喷水灭火系统进行验收，该系统设计喷头数量为300个。在检查喷头安装间距时，检查数量应不少于（ ）个。",[110,112,114,116],{"key":20,"text":111,"correct":22},"15",{"key":24,"text":113,"correct":29},"20",{"key":27,"text":115,"correct":22},"25",{"key":31,"text":117,"correct":22},"30",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},935995,"下列关于喷头选型的说法，错误的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"顶板为水平面的医院病房内采用边墙型喷头",{"key":24,"text":125,"correct":22},"预作用系统采用干式下垂型喷头",{"key":27,"text":127,"correct":22},"地下商场采用RTI=50（m·s）0．5的喷头",{"key":31,"text":129,"correct":29},"自动喷水防护冷却系统不应采用边墙型洒水喷头",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},935996,"自动喷水灭火系统施工安装前,相关组件需要进行进场现场检查,某消防安全机构对进场的水流指示器和末端试水装置进行检查时,下列说法正确的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"试验压力为 1.0MPa,流量为 15.0L,\u002Fmin,水流指示器报警",{"key":24,"text":137,"correct":29},"流量为 40L\u002Fmin 时,水流指示器报警",{"key":27,"text":139,"correct":22},"具当水流指示器入口前设置控制阀时，应采用蝶阀",{"key":31,"text":141,"correct":22},"实验压力为额定工作压力的1.1倍,保压时间为3min,末端试水装置试水阀关闭,测试结束时各组件无渗漏",{"id":143,"libraryId":5,"type":144,"typeLabel":145,"stem":146,"options":147,"answer":159,"analysis":33},935997,2,"多选题","对自动喷水灭火系统洒水喷头进行现场检测时，喷头溅水盘或者本体上应具有的永久性标识有（ ）。",[148,150,152,154,156],{"key":20,"text":149,"correct":29},"型号规格",{"key":24,"text":151,"correct":29},"商标",{"key":27,"text":153,"correct":29},"生产时间",{"key":31,"text":155,"correct":22},"玻璃球色标",{"key":157,"text":158,"correct":29},"E","响应时间指数","ABCE",{"id":161,"libraryId":5,"type":144,"typeLabel":145,"stem":162,"options":163,"answer":174,"analysis":33},935998,"某建筑采用湿式自动喷水灭火系统保护，该建筑内厨房环境温度为35℃，设置型号为XC1K-ZSTS15-79℃喷头，则关于该喷头的说法，正确的有（ ）。",[164,166,168,170,172],{"key":20,"text":165,"correct":22},"喷头的安装方式为直立型",{"key":24,"text":167,"correct":29},"该喷头为快速响应喷头",{"key":27,"text":169,"correct":29},"喷头公称口径为15mm",{"key":31,"text":171,"correct":22},"玻璃球色标为绿色",{"key":157,"text":173,"correct":22},"喷头公称动作温度与该场所相符","BC",{"id":176,"libraryId":5,"type":144,"typeLabel":145,"stem":177,"options":178,"answer":188,"analysis":33},935999,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017的规定，下列组件需有水流方向的永久性标志的有（ ）。",[179,180,182,184,186],{"key":20,"text":21,"correct":29},{"key":24,"text":181,"correct":29},"水泵接合器",{"key":27,"text":183,"correct":29},"止回阀",{"key":31,"text":185,"correct":22},"自动排气阀",{"key":157,"text":187,"correct":22},"压力开关","ABC",{"id":190,"libraryId":5,"type":144,"typeLabel":145,"stem":191,"options":192,"answer":159,"analysis":33},936000,"干式报警阀组在安装过程中，需要安装压力表的部位有（ ）。",[193,195,197,199,201],{"key":20,"text":194,"correct":29},"报警阀充水一侧",{"key":24,"text":196,"correct":29},"空气压缩机的气泵上",{"key":27,"text":198,"correct":29},"与空气压缩机配套使用的储气罐上",{"key":31,"text":200,"correct":22},"延迟器上",{"key":157,"text":202,"correct":29},"报警阀充气一侧",{"id":204,"libraryId":5,"type":144,"typeLabel":145,"stem":205,"options":206,"answer":174,"analysis":33},936001,"下列灭火系统中，需要进行气压试验的有（ ）。",[207,209,211,213,215],{"key":20,"text":208,"correct":22},"湿式自动喷水灭火系统",{"key":24,"text":210,"correct":29},"干式自动喷水灭火系统",{"key":27,"text":212,"correct":29},"预作用自动喷水灭火系统",{"key":31,"text":214,"correct":22},"雨淋系统",{"key":157,"text":216,"correct":22},"水幕系统",{"id":218,"libraryId":5,"type":144,"typeLabel":145,"stem":219,"options":220,"answer":231,"analysis":33},936002,"自动喷水灭火系统施工前对到场的400只闭式喷头进行密封性能试验，正确的做法有（ ）。",[221,223,225,227,229],{"key":20,"text":222,"correct":29},"密封性能试验的试验压力为3．0 MPa",{"key":24,"text":224,"correct":29},"密封性能试验的保压时间为5 min",{"key":27,"text":226,"correct":22},"随机从到场喷头中抽取1％，共4只作为试验喷头",{"key":31,"text":228,"correct":22},"当1只喷头试验不合格时，再抽取2％，共8只的到场喷头进行重复试验",{"key":157,"text":230,"correct":29},"累计2只喷头试验不合格时，拒绝使用该批喷头","ABE",{"id":233,"libraryId":5,"type":144,"typeLabel":145,"stem":234,"options":235,"answer":246,"analysis":33},936003,"对自动喷水灭火系统的干式报警阀组进行检查，下列关于干式报警阀组的安装方法中，符合规范要求的有（ ）。",[236,238,240,242,244],{"key":20,"text":237,"correct":29},"干式报警阀组宜安装在不发生冰冻的场所",{"key":24,"text":239,"correct":29},"低气压预报警装置安装在配水干管一侧",{"key":27,"text":241,"correct":22},"充气连接管路的接口安装在报警阀气室充注水位以上部位，充气连接管道的直径为13 mm",{"key":31,"text":243,"correct":29},"安装完成后，向报警阀气室注入高度为80 mm的清水",{"key":157,"text":245,"correct":29},"安全排气阀安装在气源与报警阀组之间，靠近报警阀组一侧","ABDE",{"id":248,"libraryId":5,"type":144,"typeLabel":145,"stem":249,"options":250,"answer":261,"analysis":33},936004,"对不同类型喷头进行安装时，安装方式正确的包括（ ）。",[251,253,255,257,259],{"key":20,"text":252,"correct":29},"隐蔽式喷头安装时，喷头根部螺纹及其部分或者全部本体嵌入顶棚护罩内，喷头下垂安装于配水支管上",{"key":24,"text":254,"correct":29},"干式喷头连接于特殊的短立管上，根据其保护区域结构特征和喷头型号、规格，直立向上、下垂或者水平安装于配水支管上",{"key":27,"text":256,"correct":29},"齐平式喷头安装时，喷头根部螺纹及其部分本体下垂安装于顶棚内配水支管上，部分或者全部热敏元件随部分喷头本体安装于吊顶下",{"key":31,"text":258,"correct":29},"边墙型喷头根据选定的型号、规格，水平安装于顶棚下的边墙上，或者直立向上、下垂安装于顶棚下",{"key":157,"text":260,"correct":22},"下垂型喷头连接DN25 mm的短立管或者直接向上直立安装于配水支管上","ABCD",{"id":263,"libraryId":5,"type":144,"typeLabel":145,"stem":264,"options":265,"answer":276,"analysis":33},936005,"对某商场设置的湿式自动喷水灭火系统进行年度检测。打开末端试水装置，水流指示器动作、压力开关动作、消防水泵启动、水力警铃报警。检查发现末端试水装置出水压力为 0.05MPa ，但水力警铃不能持续报警，下列关于水力警铃不能持续报警的原因分析，正确的是（ ）。",[266,268,270,272,274],{"key":20,"text":267,"correct":29},"水力警铃安装调试不符合要求",{"key":24,"text":269,"correct":22},"延迟器下部的出水孔被堵塞",{"key":27,"text":271,"correct":29},"产品质量问题",{"key":31,"text":273,"correct":29},"水力警铃铃锤机构被卡住",{"key":157,"text":275,"correct":22},"水泵供水压力不足","ACD",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},936006,"某建设单位对建筑内自动喷水灭火系统进行检查测试，下列结果不符合规范要求的是（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":29},"对系统减压阀进行压力流量测试，测试的排水通过DN80的排水管道排走",{"key":24,"text":284,"correct":22},"开启报警阀组模拟试验阀，水力警铃在50s内报警",{"key":27,"text":286,"correct":22},"压力开关直接启动消防喷淋泵",{"key":31,"text":288,"correct":22},"自动水灭火系统末端试水装置处的排水立管管径，应根据末端试水装置的泄流量确定，并不宜小于DN75",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":27,"analysis":33},936007,"下列自动喷水灭火系统的检查中，属于季度检查的是（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"水泵接合器完好性检查",{"key":24,"text":296,"correct":22},"内燃机驱动的消防水泵启动运行测试",{"key":27,"text":298,"correct":29},"末端试水阀放水试验",{"key":31,"text":300,"correct":22},"过滤器排渣、完好状态检查",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":31,"analysis":33},936008,"为确保管网安装后不出现漏水、管道及管件承压能力不足、杂质及污损物影响系统正常使用等问题出现，管网安装完毕后，应组织实施管网试验和冲洗。下列关于自动喷水灭火系统的试验与冲洗，说法错误的是（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"自动喷水灭火系统水压强度试验和水压严密性试验除对系统管网进行试验外，也可将回填的水源、进户管和室内埋地管道等一并纳入试验范围，所有管网全数测试",{"key":24,"text":308,"correct":22},"强度试验采用水作为介质进行试验",{"key":27,"text":310,"correct":22},"水压强度试验的测试点应设在系统管网的最低点",{"key":31,"text":312,"correct":29},"环境温度不宜低于4度，当低于4度时，应采取防冻措施，以确保水压试验正常进行",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":31,"analysis":33},936009,"某购物中心，地上5层，层高6m，每层建筑面积为4000m2，均采用不燃和难燃材料装修，建筑内设置干式自动喷水灭火系统保护，并采用直立型标准覆盖面积洒水喷头，则所设置的自动喷水灭火系统应至少设置（ ）台干式报警阀组。",[317,319,321,323],{"key":20,"text":318,"correct":22},"6",{"key":24,"text":320,"correct":22},"5",{"key":27,"text":322,"correct":22},"3",{"key":31,"text":324,"correct":29},"4",{"id":326,"libraryId":5,"type":144,"typeLabel":145,"stem":327,"options":328,"answer":339,"analysis":33},936010,"下列关于喷头的安装，说法正确的是（ ）。",[329,331,333,335,337],{"key":20,"text":330,"correct":22},"当喷头的公称直径小于15mm时，在系统配水干管、配水管上应安装过滤器",{"key":24,"text":332,"correct":29},"梁、通风管道、排管、桥架宽度大于1．2m时，在其腹面以下部位应增设喷头",{"key":27,"text":334,"correct":29},"除吊顶型洒水喷头及吊顶下喷头外，直立型、下垂型喷头其溅水盘与顶板的距离，不应小于75mm，不应大于150mm",{"key":31,"text":336,"correct":22},"装设通透性吊顶的场所，喷头应布置在顶板下",{"key":157,"text":338,"correct":29},"净空高度大于800mm的闷顶和技术夹层内有可燃物时，应设置喷头","BCE",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":31,"analysis":33},936011,"下列关于报警阀组的安装，不符合规范要求的是（ ）。",[344,346,348,350],{"key":20,"text":345,"correct":22},"报警阀阀体底边距室内地面高度为1．2m",{"key":24,"text":347,"correct":22},"报警阀组安装在室内时，室内地面增设排水设施",{"key":27,"text":349,"correct":22},"报警阀组的安装顺序为先安装水源控制阀、报警阀，再进行报警阀辅助管道的连接",{"key":31,"text":351,"correct":29},"采用公称直径为DN20长度为25m的镀锌钢管连接水力警铃",{"id":353,"libraryId":5,"type":144,"typeLabel":145,"stem":354,"options":355,"answer":261,"analysis":33},936012,"某消防技术服务机构对新建的综合楼配置自动喷水灭火系统，首先查阅消防设计文件，确定场所使用的喷头型号、规格，待系统试压、冲洗合格后，进行喷头安装。下列关于不同类型喷头的安装方式，正确的有（）。",[356,357,359,361,363],{"key":20,"text":252,"correct":29},{"key":24,"text":358,"correct":29},"齐平式喷头安装时，喷头根部螺纹及其部分本体下垂安装于吊顶内配水支管上，部分或者全部热敏元件随部分喷头本体安装于吊顶下",{"key":27,"text":360,"correct":29},"干式喷头连接于特殊的短立管上，根据其保护区域结构特征和喷头规格型号，直立向上、下垂或者水平安装于配水支管上",{"key":31,"text":362,"correct":29},"喷头安装在易受机械损伤处时，加设喷头防护罩",{"key":157,"text":364,"correct":22},"下垂型喷头连接DN25mm的短立管或者直接向上直立安装于配水支管上",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":31,"analysis":33},936014,"闭式自动喷水灭火系统的喷头，其公称动作温度宜高于环境最高温度（）℃。",[369,371,373,375],{"key":20,"text":370,"correct":22},"60",{"key":24,"text":372,"correct":22},"45",{"key":27,"text":374,"correct":22},"35",{"key":31,"text":117,"correct":29},{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":27,"analysis":33},936015,"下列不属于喷头现场检查内容的是（ ）。",[380,382,384,386],{"key":20,"text":381,"correct":22},"喷头外观",{"key":24,"text":383,"correct":22},"密封性能试验",{"key":27,"text":385,"correct":29},"水压强度试验",{"key":31,"text":387,"correct":22},"质量偏差",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":24,"analysis":33},936016,"自动喷水灭火系统中，通常采用减压阀来控制管道（ ）。",[392,394,396,398],{"key":20,"text":393,"correct":22},"动压",{"key":24,"text":395,"correct":29},"静压",{"key":27,"text":397,"correct":22},"泄压",{"key":31,"text":399,"correct":22},"水流方向",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":27,"analysis":33},936017,"下列关于喷头外观标志的检查说法中，正确的是（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":22},"喷头规格型号的标记由生产厂商名称、生产时间、响应时间指数（RTI）等部分组成",{"key":24,"text":407,"correct":22},"隐蔽式喷头的盖板上有水流方向标识",{"key":27,"text":409,"correct":29},"所有标识均为永久性标识，标识正确、清晰",{"key":31,"text":411,"correct":22},"边墙型喷头上有“不可涂覆”等文字标识",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":31,"analysis":33},936018,"某闭式喷头的玻璃球色标为橙色，则该喷头玻璃球对应的温度为（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"93℃",{"key":24,"text":419,"correct":22},"68℃",{"key":27,"text":421,"correct":22},"79℃",{"key":31,"text":423,"correct":29},"57℃",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":24,"analysis":33},936019,"下列关于末端试水装置的密封性能检查中，说法正确的是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":22},"试验压力应为额定工作压力1．5倍的静水压力，保压时间应不小于2min",{"key":24,"text":431,"correct":29},"试验压力应为额定工作压力1．1倍的静水压力，保压时间应不小于5min",{"key":27,"text":433,"correct":22},"试验压力应为额定工作压力1．5倍的静水压力，保压时间应不小于5min",{"key":31,"text":435,"correct":22},"试验压力应为额定工作压力1．1倍的静水压力，保压时间应不小于2min",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":20,"analysis":33},936020,"干式报警阀组安装完成后，应向报警阀气室注入高度为（ ）的清水。",[440,442,444,446],{"key":20,"text":441,"correct":29},"50～100mm",{"key":24,"text":443,"correct":22},"60～100mm",{"key":27,"text":445,"correct":22},"50～150mm",{"key":31,"text":447,"correct":22},"60～150mm",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":20,"analysis":33},936021,"某办公室安装红色的闭式玻璃球喷头，则可判断该场所最高环境温度约为（ ）℃。",[452,454,456,458],{"key":20,"text":453,"correct":29},"38",{"key":24,"text":455,"correct":22},"68",{"key":27,"text":457,"correct":22},"58",{"key":31,"text":459,"correct":22},"93",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},936022,"按照规范要求，对雨淋报警阀组进行调试时，当雨淋报警阀公称直径大于200mm时，该阀组应在（ ）s内启动。",[464,465,466,468],{"key":20,"text":117,"correct":22},{"key":24,"text":370,"correct":29},{"key":27,"text":467,"correct":22},"90",{"key":31,"text":469,"correct":22},"120",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":24,"analysis":33},936023,"下列关于自动喷水灭火系统管网试压和冲洗的说法中，错误的是（ ）。",[474,476,478,480],{"key":20,"text":475,"correct":22},"对不能参与试压的设备、仪表、阀门及附件应加以隔离或拆除",{"key":24,"text":477,"correct":29},"系统试压过程中，当出现泄漏时，应继续试验，以保持试验的连续性",{"key":27,"text":479,"correct":22},"管网冲洗宜用水进行，冲洗前，应对系统的仪表采取保护措施",{"key":31,"text":481,"correct":22},"水压试验和水冲洗宜采用生活用水进行，不得使用海水或含有腐蚀性化学物质的水",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":20,"analysis":33},936024,"某建设单位对预作用系统进行竣工验收，当系统由火灾自动报警系统和充气管道上设置的压力开关开启的预作用装置时，其配水管道充水时间不宜大于（ ）min。",[486,488,490,491],{"key":20,"text":487,"correct":29},"1",{"key":24,"text":489,"correct":22},"2",{"key":27,"text":322,"correct":22},{"key":31,"text":324,"correct":22},{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":33},936025,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，对灭火系统进行验收时，应对喷头型号、规格、设置场所进行抽查，抽查喷头的数量应为设计喷头数量的（ ），总数不少于（ ）个。",[496,498,500,502],{"key":20,"text":497,"correct":22},"10％，20",{"key":24,"text":499,"correct":29},"10％，40",{"key":27,"text":501,"correct":22},"20％，20",{"key":31,"text":503,"correct":22},"20％，40",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":20,"analysis":33},936026,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017要求，应每个季度对系统所有的末端试水阀和报警阀旁的放水试验阀进行一次放水试验，并应检查（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":29},"系统启动、报警功能以及出水情况是否正常",{"key":24,"text":511,"correct":22},"系统严密性是否正常",{"key":27,"text":513,"correct":22},"系统压力是否正常",{"key":31,"text":515,"correct":22},"系统水压强度是否正常",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":33},936027,"闭式喷头密封性能试验的试验压力为3．0MPa，保压时间不少于（ ）min。",[520,521,522,523],{"key":20,"text":489,"correct":22},{"key":24,"text":322,"correct":29},{"key":27,"text":320,"correct":22},{"key":31,"text":524,"correct":22},"10",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":20,"analysis":33},936028,"下列有关水力警铃安装要求的说法，不正确的是（ ）。",[529,531,533,535],{"key":20,"text":530,"correct":29},"水力警铃应安装在消防控制室或值班室附近的外墙上",{"key":24,"text":532,"correct":22},"水力警铃应安装检修、测试用的阀门",{"key":27,"text":534,"correct":22},"水力警铃和报警阀之间应采用热镀锌钢管连接",{"key":31,"text":536,"correct":22},"水力警铃启动时，警铃声强度应不小于70dB",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":27,"analysis":33},936029,"下列有关自动喷水灭火系统管网冲洗和试压的说法，错误的是（ ）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"管网安装完毕后，应对其进行强度试验、严密性试验和冲洗",{"key":24,"text":544,"correct":22},"强度试验和严密性试验宜用水进行",{"key":27,"text":546,"correct":29},"干式喷水灭火系统、湿式喷水灭火系统、预作用喷水灭火系统应做水压试验和气压试验",{"key":31,"text":548,"correct":22},"系统试压完成后，应及时拆除所有临时盲板及试验用的管道，并应与记录核对无误",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":20,"analysis":33},936030,"某工地在自动喷水灭火系统施工安装前进行检测，下列关于报警阀组现场检查验收项目中，属于报警阀组结构检查的是（ ）。",[553,555,557,559],{"key":20,"text":554,"correct":29},"阀体上设有放水口，放水口的公称直径不小于20mm",{"key":24,"text":556,"correct":22},"报警阀的商标、规格型号等标志齐全，阀体上有水流指示方向的永久性标识",{"key":27,"text":558,"correct":22},"水力警铃的铃锤转动灵活，无阻滞现象",{"key":31,"text":560,"correct":22},"报警阀的规格型号符合经消防设计审核合格或者备案的消防设计文件要求",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":27,"analysis":33},936031,"某工地现收到一批闭式喷头，规格如下：ZSTX15—93℃喷头500只，ZSTX15—68℃喷头700只，ZSTX15—68℃喷头300只，现对该批喷头进行密封性能试验，下列做法正确的是（ ）。",[565,567,569,571],{"key":20,"text":566,"correct":22},"随机抽取喷头共15只，试验压力为3．0MPa，保压3min，当一只不合格时，再随机抽取30只重新试验，有1只不合格时，该批喷头不能使用",{"key":24,"text":568,"correct":22},"随机抽取喷头共15只，试验压力为5．0MPa，保压5min，当一只不合格时，再随机抽取30只重新试验，有1只不合格时，该批喷头不能使用",{"key":27,"text":570,"correct":29},"随机抽取ZSTX15—93℃喷头10只，ZSTX15—68℃喷头7只，ZSTX15—68℃喷头5只，试验压力为3．0MPa，保压3min，当两只不合格时，该批喷头不能使用",{"key":31,"text":572,"correct":22},"随机抽取ZSTX15—93℃喷头10只，ZSTX15-68℃喷头7只，ZSTX15～68℃喷头5只，试验压力为5．0MPa，保压5min，当两只不合格时，该批喷头不能使用",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":31,"analysis":33},936032,"下列关于自动喷水灭火系统周期性维护管理的说法中，正确的是（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":22},"每季度对所有的末端试水阀和报警阀的放水实验阀进行一次放水实验，并应检查系统的压力是否正常",{"key":24,"text":580,"correct":22},"每季度对所有的末端试水阀和报警阀的放水实验阀进行一次放水实验，并应检查系统的出水情况是否正常",{"key":27,"text":582,"correct":22},"每季度对所有的末端试水阀和报警阀的放水实验阀进行一次放水实验，并应检查系统的严密性是否正常",{"key":31,"text":584,"correct":29},"每季度对所有的末端试水阀和报警阀的放水实验阀进行一次放水实验，并应检查系统的启动、报警功能以及出水情况是否正常",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":20,"analysis":33},936033,"某自动喷水灭火系统安装工地到新到场的末端试水装置进行进场检验。根据现行规范要求，末端试水装置密封性能试验的压力和保压时间分别是（ ）。",[589,591,593,595],{"key":20,"text":590,"correct":29},"额定工作压力的1.1倍和5min",{"key":24,"text":592,"correct":22},"额定工作压力的1.2倍和5min",{"key":27,"text":594,"correct":22},"额定工作压力的1.1倍和3min",{"key":31,"text":596,"correct":22},"额定工作压力的1.2倍和3min",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":24,"analysis":33},936034,"某消防工程施工现场新到一批喷头，其中用于湿式系统和雨淋系统的喷头分别为1500只和300只，施工单位根据规定对该批喷头进行现场检查，下列关于喷头现场检验的说法中，正确的是（ ）。",[601,603,605,607],{"key":20,"text":602,"correct":22},"至少抽取3只喷头进行密封性试验",{"key":24,"text":604,"correct":29},"至少抽取15只喷头进行密封性试验",{"key":27,"text":606,"correct":22},"至少抽取18只喷头进行密封性试验",{"key":31,"text":608,"correct":22},"至少抽取20只喷头进行密封性试验",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":24,"analysis":33},936035,"自动喷水灭火系统配水干管应做红色环圈标志，红色环圈标志的宽度不应小于（ ）mm。",[613,614,615,616],{"key":20,"text":524,"correct":22},{"key":24,"text":113,"correct":29},{"key":27,"text":117,"correct":22},{"key":31,"text":617,"correct":22},"50",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":20,"analysis":33},936036,"某消防工程施工单位对到场的干式报警阀组进行现场检查，关于干式报警阀组现场检查要求的说法中，不正确的是（ ）。",[622,624,626,628],{"key":20,"text":623,"correct":29},"阀体上应设有放水口，放水口的公称直径不小于25mm",{"key":24,"text":625,"correct":22},"阀体的阀瓣组件的供水侧，设有在不开启阀门的情况下测试报警装置的测试管路",{"key":27,"text":627,"correct":22},"应对报警阀组进行渗漏试验测试报警阀的密封性，试验压力为额定工作压力的2倍的静水压力，保压时间不小于5min",{"key":31,"text":629,"correct":22},"阀体内清洁、无异物堵塞，报警阀阀瓣开启后能够复位",{"id":631,"libraryId":5,"type":15,"typeLabel":16,"stem":632,"options":633,"answer":31,"analysis":33},936037,"下列关于自动喷水灭火系统报警阀组的设置要求中，正确的是（ ）。",[634,636,638,640],{"key":20,"text":635,"correct":22},"对于干式系统，一个报警阀组控制的喷头数不宜超过800个",{"key":24,"text":637,"correct":22},"对于预作用系统，一个报警阀组控制的喷头数不宜超过500个",{"key":27,"text":639,"correct":22},"报警阀组的报警管路总长度不宜大于30m",{"key":31,"text":641,"correct":29},"每个报警阀组供水的最高和最低位置的喷头高程差不宜大于50m",[643,646,649,652,655,658],{"id":15,"name":644,"category":7,"favorite":645},"领导干部任职前廉政法规知识测试题",92,{"id":647,"name":648,"category":7,"favorite":15},595,"建筑结构与设备",{"id":650,"name":651,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":653,"name":654,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":656,"name":657,"category":7,"favorite":8},534,"BIM工程师",{"id":659,"name":657,"category":7,"favorite":8},535]