[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":649},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,26,50,2974,[13,34,46,58,70,82,100,115,130,144,156,168,180,192,204,216,228,240,252,264,276,288,300,312,324,336,348,360,375,390,405,419,433,444,459,473,485,497,507,519,531,543,553,565,577,589,601,613,625,637],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},935937,1,"单选题","根据《消防给水及消火栓系统技术规范》GB50974—2014，消火栓进场时要进行进场检查，消火栓固定接口要进行密封性能试验，以无渗漏无损伤为合格，下列试验方法符合规范要求的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","试验数量宜从每批中抽查1％，但不应少于5个，应缓慢而均匀地升压1．6MPa，应保压2min。当两个及两个以上不合格时，不应使用该批消火栓",true,{"key":24,"text":25,"correct":26},"B","试验数量宜从每批中抽查1％，但不应少于10个，应缓慢而均匀地升压1．6MPa，应保压2min。当两个及两个以上不合格时，不应使用该批消火栓",false,{"key":28,"text":29,"correct":26},"C","试验数量宜从每批中抽查1％，但不应少于5个，应缓慢而均匀地升压1．6MPa，应保压5min。当两个及两个以上不合格时，不应使用该批消火栓",{"key":31,"text":32,"correct":26},"D","试验数量宜从每批中抽查1％，但不应少于10个，应缓慢而均匀地升压1．6MPa，应保压5min。当两个及两个以上不合格时，不应使用该批消火栓","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},935938,"下列关于消防给水系统采用减压阀减压分区供水时的设置要求正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"减压阀应设置在报警阀组后",{"key":24,"text":41,"correct":26},"减压阀的阀前阀后压力比值不宜大于4：1",{"key":28,"text":43,"correct":26},"比例式减压阀宜水平安装，可调式减压阀宜垂直安装",{"key":31,"text":45,"correct":22},"减压阀应设置流量检测测试接口或流量计",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},935939,"对某民用建筑设置的减压阀进行验收， 根据现行国家标准《消防给水及消火栓系统技术规范》GB 50974—2014，关于减压阀的验收要求中，不正确的有（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"减压阀的型号、规格、设计压力和设计流量应符合设计要求",{"key":24,"text":53,"correct":26},"减压阀在小流量、设计流量和设计流量的150％时不应出现噪声明显增加或管道出现喘振",{"key":28,"text":55,"correct":22},"减压阀的水头损失不应小于设计阀后静压和动压差",{"key":31,"text":57,"correct":26},"应按安装总量全数检查",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},935940,"下列关于建筑物消防给水设计流量的说法中，不正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"成组布置的建筑物室外消火栓设计流量，应按设计流量较大的两座建筑物的体积之和确定",{"key":24,"text":65,"correct":26},"当单座建筑的总建筑面积大于500000m2时，建筑物室外消火栓设计流量应按相应规定的最大值增加一倍",{"key":28,"text":67,"correct":26},"消防软管卷盘、轻便消防水龙及多层住宅楼梯间中的干式消防竖管，其消火栓设计流量可不计入室内消防给水设计流量",{"key":31,"text":69,"correct":26},"当一座多层建筑有多种使用功能时，室内消火栓设计流量应分别按不同功能计算，且应取最大值",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},935941,"室内消火栓箱体安装的垂直度允许偏差为（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"±2mm",{"key":24,"text":77,"correct":22},"±3mm",{"key":28,"text":79,"correct":26},"±4mm",{"key":31,"text":81,"correct":26},"±5mm",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},935942,2,"多选题","按喷嘴直径进行分类，消防球阀转换式消防多用水枪的喷嘴规格包括（）。",[88,90,92,94,96],{"key":20,"text":89,"correct":26},"6mm",{"key":24,"text":91,"correct":26},"8mm",{"key":28,"text":93,"correct":26},"10mm",{"key":31,"text":95,"correct":22},"16mm",{"key":97,"text":98,"correct":22},"E","19mm","DE",{"id":101,"libraryId":5,"type":84,"typeLabel":85,"stem":102,"options":103,"answer":114,"analysis":33},935943,"下列关于内扣式消防接口的抗跌落性能检测说法中，正确的有（ ）。",[104,106,108,110,112],{"key":20,"text":105,"correct":26},"内扣式接口以扣爪垂直朝上的位置，接口的最低点离地面（2．0±0．05）m高度自由跌落",{"key":24,"text":107,"correct":22},"内扣式接口以扣爪垂直朝下的位置，接口的最低点离地面（1．5±0．05）m高度自由跌落",{"key":28,"text":109,"correct":26},"需反复进行2次",{"key":31,"text":111,"correct":22},"需反复进行5次",{"key":97,"text":113,"correct":26},"需反复进行3次","BD",{"id":116,"libraryId":5,"type":84,"typeLabel":85,"stem":117,"options":118,"answer":129,"analysis":33},935944,"某超高层写字楼地上35层，地下3层，地下部分为汽车库和部分设备用房，其室内消火栓系统施工结束后，消防设施检查机构的人员对该建筑内安装的室内消火栓系统进行检查，检查结果如下，其中不符合规范要求的是（ ）。",[119,121,123,125,127],{"key":20,"text":120,"correct":22},"消防水泵房设置在地下三层，并设有防止水淹的技术措施",{"key":24,"text":122,"correct":26},"消防水泵控制柜与水泵房设置在同一房间内，水泵控制柜的防护等级为IP55",{"key":28,"text":124,"correct":22},"消防水泵双路电源自动切换时间为30s",{"key":31,"text":126,"correct":22},"系统采用消防水泵转输水箱分区供水，转输水箱的有效容积为18m3",{"key":97,"text":128,"correct":22},"地上部分消防电梯前室设有消火栓，地下部分消防电梯前室未设置消火栓","ACDE",{"id":131,"libraryId":5,"type":84,"typeLabel":85,"stem":132,"options":133,"answer":129,"analysis":33},935945,"下列关于室外消火栓的说法中，正确的有（）。",[134,136,138,140,142],{"key":20,"text":135,"correct":22},"室外消火栓按其安装场合可分为地上式、地下式和折叠式三种",{"key":24,"text":137,"correct":26},"同一建筑物设置的室外消火栓应采用同一厂家的栓口及配件",{"key":28,"text":139,"correct":22},"消火栓栓口安装高度允许偏差为±20mm",{"key":31,"text":141,"correct":22},"地下式消火栓顶部出水口应正对井口",{"key":97,"text":143,"correct":22},"地上干式室外消火栓和地下式室外消火栓适用于气温较寒冷的地区",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":24,"analysis":33},935946,"某场所新到一批闭式喷头，数量为1200只，按照规定应至少抽查（ ）只喷头进行密封性试验。",[148,150,152,154],{"key":20,"text":149,"correct":26},"6",{"key":24,"text":151,"correct":22},"12",{"key":28,"text":153,"correct":26},"24",{"key":31,"text":155,"correct":26},"48",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":28,"analysis":33},935947,"下列关于报警阀组安装要求的说法中，错误的是（ ）。",[160,162,164,166],{"key":20,"text":161,"correct":26},"报警阀阀体正面与墙的距离不应小于1．2m",{"key":24,"text":163,"correct":26},"采用传动管开启的雨淋阀组，水传动管的安装应符合湿式系统的有关要求",{"key":28,"text":165,"correct":22},"干式报警阀组的低气压报警装置应安装在供水管一侧",{"key":31,"text":167,"correct":26},"预作用系统雨淋阀组后的管道若需充气，其安装应按干式报警阀组有关要求进行",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":28,"analysis":33},935948,"某二类高层酒店设有湿式自动喷水灭火系统，系统施工结束后，某消防技术检测机构对其进行检查，下列检查结果中，不符合现行国家技术标准的是（ ）。",[172,174,176,178],{"key":20,"text":173,"correct":26},"顶板为水平面的客房采用边墙型喷头",{"key":24,"text":175,"correct":26},"每个报警阀组控制最不利点洒水喷头处都设有末端试水装置",{"key":28,"text":177,"correct":22},"在配水管与配水支管相接处的配水支管上设有水流指示器，水流指示器前安装止回阀",{"key":31,"text":179,"correct":26},"分别开启系统中的每一个试水阀，压力开关均能正常动作",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":31,"analysis":33},935949,"下列选项中不会造成湿式报警阀报警管路误报警的是（ ）。",[184,186,188,190],{"key":20,"text":185,"correct":26},"未按照安装图样安装",{"key":24,"text":187,"correct":26},"延迟器下部孔板堵塞",{"key":28,"text":189,"correct":26},"报警管路未按设计图纸",{"key":31,"text":191,"correct":22},"报警管路阀门关闭",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":28,"analysis":33},935950,"下列不属于自动喷水灭火系统调试内容的是（ ）。",[196,198,200,202],{"key":20,"text":197,"correct":26},"消防水泵调试",{"key":24,"text":199,"correct":26},"稳压泵调试",{"key":28,"text":201,"correct":22},"水源控制阀调试",{"key":31,"text":203,"correct":26},"排水设施调试",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":24,"analysis":33},935951,"雨淋报警阀组调试采用检测、试验管道进行供水，自动和手动方式启动的雨淋报警阀，在联动信号发出或者手动控制操作后15s内启动；公称直径大于200mm的雨淋报警阀，在60s之内启动。雨淋报警阀调试时，当报警水压为（ ）MPa，水力警铃发出报警铃声。",[208,210,212,214],{"key":20,"text":209,"correct":26},"0．03",{"key":24,"text":211,"correct":22},"0．05",{"key":28,"text":213,"correct":26},"0．07",{"key":31,"text":215,"correct":26},"0．09",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":31,"analysis":33},935952,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列不属于每月检查的是（ ）。",[220,222,224,226],{"key":20,"text":221,"correct":26},"喷头的备用量检查",{"key":24,"text":223,"correct":26},"水泵接合器的完好性检查",{"key":28,"text":225,"correct":26},"过滤器排渣",{"key":31,"text":227,"correct":22},"对消防储水设备进行检查，修补缺损",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":24,"analysis":33},935953,"对湿式自动喷水灭火系统进行年度检测，打开某个防火分区的试水阀，水流指示器和压力开关均未动作，消防水泵也未启动，现场检查压力开关和水流指示器及消防水泵均正常，出现这种情况的原因最有可能的是（ ）。",[232,234,236,238],{"key":20,"text":233,"correct":26},"水泵控制柜未设定在“自动”状态",{"key":24,"text":235,"correct":22},"水流指示器前的信号蝶阀关闭",{"key":28,"text":237,"correct":26},"报警管路控制阀关闭",{"key":31,"text":239,"correct":26},"消防联动控制器处于手动状态",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":28,"analysis":33},935954,"某综合楼的自动喷水灭火系统的设计工作压力为1．1 MPa，消防工程施工单位对系统的管道进行水压试验，则该系统的水压强度试验不应低于（ ）MPa。",[244,246,248,250],{"key":20,"text":245,"correct":26},"1．65",{"key":24,"text":247,"correct":26},"1．4",{"key":28,"text":249,"correct":22},"1．5",{"key":31,"text":251,"correct":26},"1．3",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":31,"analysis":33},935955,"某喷头标记为ZSTBX20—68℃，该喷头属于（ ）。",[256,258,260,262],{"key":20,"text":257,"correct":26},"吊顶隐蔽型喷头",{"key":24,"text":259,"correct":26},"下垂型喷头",{"key":28,"text":261,"correct":26},"干式直立型喷头",{"key":31,"text":263,"correct":22},"下垂边墙型喷头",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":31,"analysis":33},935956,"下列关于自动喷水灭火系统组件安装的说法，错误的是（ ）。",[268,270,272,274],{"key":20,"text":269,"correct":26},"报警阀和水力警铃的连接管当采用公称直径20mm的镀锌钢管时，长度不应超过20m",{"key":24,"text":271,"correct":26},"信号阀和水流指示器之间的间距不宜小于300mm",{"key":28,"text":273,"correct":26},"报警阀前的可调式减压阀宜水平安装，阀盖向上",{"key":31,"text":275,"correct":22},"干式报警阀充气管路上安全排气阀应安装在气源与报警阀之间，且应靠近气源侧",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":28,"analysis":33},935957,"对某商业中心内多栋建筑的自动喷水灭火系统进行检查，下列检查结果中不符合规范要求的是（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":26},"末端试水装置的连接管管径为25mm",{"key":24,"text":283,"correct":26},"干式自动喷水灭火系统的供气管道采用钢管，管径为15mm",{"key":28,"text":285,"correct":22},"短立管的管径为20mm",{"key":31,"text":287,"correct":26},"预作用系统的供气管道采用铜管，管径为10mm",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":28,"analysis":33},935958,"根据现行国家标准《自动喷水灭火系统施工及验收规范》G350261—2017，对自动喷水灭火系统的报警阀进行验收，下列关于自动喷水灭火系统管道充水时间的要求中，正确的是（ ）。",[292,294,296,298],{"key":20,"text":293,"correct":26},"干式系统配水管道充水时间不宜大于2min",{"key":24,"text":295,"correct":26},"由火灾自动报警系统和充气管道上设置的压力开关开启预作用装置的预作用系统，其管道充水时间不宜大于2min",{"key":28,"text":297,"correct":22},"雨淋系统的配水管道充水时间不宜大于2min",{"key":31,"text":299,"correct":26},"仅由火灾自动报警系统联动开启预作用装置的预作用系统，其配水管道充水时间不宜大于1min",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":31,"analysis":33},935959,"下列关于自动喷水灭火系统管网气压试验和冲洗的要求，正确的是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":26},"气压严密性试验压力应为0．28MPa，且稳压24h，压力降不应大于0．05MPa",{"key":24,"text":307,"correct":26},"气压试验的介质宜采用氮气或二氧化碳",{"key":28,"text":309,"correct":26},"管网冲洗的水流流速、流量应大于系统设计的水流流速、流量",{"key":31,"text":311,"correct":22},"水平管网冲洗时，其排水管位置应低于配水支管",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":20,"analysis":33},935960,"在自喷灭火系统中,各种不同规格的喷头均应有一定数量的备用品,其数量不应小于安装喷头总数的（ ）,且每种备用喷头不应少于（ ）个。",[316,318,320,322],{"key":20,"text":317,"correct":22},"1%,10",{"key":24,"text":319,"correct":26},"2%,10",{"key":28,"text":321,"correct":26},"1%,5",{"key":31,"text":323,"correct":26},"2%,5",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":24,"analysis":33},935961,"自动喷水灭火系统管网试压合格后，应采用生活用水进行冲洗。管网冲洗顺序为（ ）。",[328,330,332,334],{"key":20,"text":329,"correct":26},"先室外，后室内；先地上，后地下",{"key":24,"text":331,"correct":22},"先室外，后室内；先地下，后地上",{"key":28,"text":333,"correct":26},"先室内，后室外；先地上，后地下",{"key":31,"text":335,"correct":26},"先室内，后室外；先地下，后地上",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":33},935962,"自动喷水灭火系统在年度检测中，对湿式报警阀组进行检测时，在距离水力警铃（ ）处，采用声级计测量水力警铃声强值。",[340,342,344,346],{"key":20,"text":341,"correct":26},"2m",{"key":24,"text":343,"correct":22},"3m",{"key":28,"text":345,"correct":26},"4m",{"key":31,"text":347,"correct":26},"5m",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":20,"analysis":33},935963,"自动喷水灭火系统中湿式报警阀组漏水的原因不包括（ ）。",[352,354,356,358],{"key":20,"text":353,"correct":22},"限流装置过滤网被堵塞",{"key":24,"text":355,"correct":26},"排水阀门未完全关闭",{"key":28,"text":357,"correct":26},"阀瓣密封垫老化或者损坏",{"key":31,"text":359,"correct":26},"系统侧管道接口渗漏",{"id":361,"libraryId":5,"type":84,"typeLabel":85,"stem":362,"options":363,"answer":374,"analysis":33},935964,"自动喷水灭火系统因建筑高差较大造成的超压，通常在系统相应管段上安装设置（ ）以控制管道动压。",[364,366,368,370,372],{"key":20,"text":365,"correct":22},"减压孔板",{"key":24,"text":367,"correct":22},"节流管",{"key":28,"text":369,"correct":26},"减压阀",{"key":31,"text":371,"correct":26},"止回阀",{"key":97,"text":373,"correct":26},"报警阀","AB",{"id":376,"libraryId":5,"type":84,"typeLabel":85,"stem":377,"options":378,"answer":389,"analysis":33},935965,"某消防技术服务机构对已完工的湿式自动喷水灭火系统进行竣工验收检查，检查结果符合现行国家工程建设消防技术标准的是（ ）。",[379,381,383,385,387],{"key":20,"text":380,"correct":22},"在吊顶下安装了下垂型洒水喷头",{"key":24,"text":382,"correct":26},"通透面积占吊顶总面积的比例为80的场所，喷头安装在吊顶的下方",{"key":28,"text":384,"correct":22},"喷头备用品数量为20只，为安装喷头总数的1％",{"key":31,"text":386,"correct":26},"末端试水装置采用管道与排水管道直接相连",{"key":97,"text":388,"correct":26},"压力开关垂直安装于延迟器后面的竖向管道上","AC",{"id":391,"libraryId":5,"type":84,"typeLabel":85,"stem":392,"options":393,"answer":404,"analysis":33},935966,"某施工单位为保证报警阀组及其附件的安装质量和基本性能要求，对到场的报警阀组进行安装前检测，下列属于检查项目的有（ ）。",[394,396,398,400,402],{"key":20,"text":395,"correct":22},"外观质量",{"key":24,"text":397,"correct":22},"渗漏试验",{"key":28,"text":399,"correct":26},"阀门材质",{"key":31,"text":401,"correct":26},"压力等级",{"key":97,"text":403,"correct":22},"报警阀结构","ABE",{"id":406,"libraryId":5,"type":84,"typeLabel":85,"stem":407,"options":408,"answer":389,"analysis":33},935967,"某5层商场，每层层高5．4m，每层建筑面积为3500m2，消防设施检查机构对该商场设置的湿式自动喷水灭火系统进行验收前的消防设施检查。下列检查结果中，不符合现行国家消防技术标准的是（ ）。",[409,411,413,415,417],{"key":20,"text":410,"correct":22},"商场部分区域设置了隐蔽式喷头",{"key":24,"text":412,"correct":26},"打开末端试水装置，以1．5L／s的流量放水时，带延迟器的报警阀压力开关在60s内动作",{"key":28,"text":414,"correct":22},"屋顶高位消防水箱的有效容积为18m3",{"key":31,"text":416,"correct":26},"每层设置两个水流指示器",{"key":97,"text":418,"correct":26},"商场中庭环廊设置了快速响应洒水喷头",{"id":420,"libraryId":5,"type":84,"typeLabel":85,"stem":421,"options":422,"answer":404,"analysis":33},935968,"根据现行国家消防技术标准，对投入使用的自动喷水灭火系统需要每月进行检查维护的内容有（ ）。",[423,425,427,429,431],{"key":20,"text":424,"correct":22},"对控制阀门的铅封、锁链进行检查",{"key":24,"text":426,"correct":22},"消防水泵启动运转",{"key":28,"text":428,"correct":26},"对水源控制阀、报警阀组进行外观检查",{"key":31,"text":430,"correct":26},"利用末端试水装置对进行放水试验",{"key":97,"text":432,"correct":22},"检查电磁阀并做启动试验",{"id":434,"libraryId":5,"type":84,"typeLabel":85,"stem":435,"options":436,"answer":404,"analysis":33},935969,"在自动喷水灭火系统设备和组件安装完成后应对系统进行调试。根据《自动喷水灭火系统施工及验收规范》（GB 50261），系统调试主控项目应包括的内容有（ ）。",[437,439,440,441,443],{"key":20,"text":438,"correct":22},"水源测试",{"key":24,"text":197,"correct":22},{"key":28,"text":203,"correct":26},{"key":31,"text":442,"correct":26},"电动阀调试",{"key":97,"text":199,"correct":22},{"id":445,"libraryId":5,"type":84,"typeLabel":85,"stem":446,"options":447,"answer":458,"analysis":33},935970,"对自动喷水灭火系统进行水压试验，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于水压试验要求的说法中，正确的是（ ）。",[448,450,452,454,456],{"key":20,"text":449,"correct":26},"水压试验时环境温度不宜低于4℃",{"key":24,"text":451,"correct":26},"水压强度试验的测试点应设在系统管网的压力最不利点",{"key":28,"text":453,"correct":22},"对管网注水时应将管网内的空气排净，并应缓慢升压，达到试验压力后稳压30min后，管网应无泄漏、无变形，且压力降不应大于0．05MPa",{"key":31,"text":455,"correct":22},"自动喷水灭火系统的水源干管、进户管和室内埋地管道，应在回填前单独或与系统一起进行水压强度试验和水压严密性试验",{"key":97,"text":457,"correct":26},"水压严密性试验应在水压强度试验和管网冲洗合格后进行，试验压力应为设计工作压力，稳压24h，压力降不应大于0．01Mpa","CD",{"id":460,"libraryId":5,"type":84,"typeLabel":85,"stem":461,"options":462,"answer":114,"analysis":33},935971,"建筑高度为54m的18层住宅建筑，一梯4户，每户建筑面积98m2，每个单元设置一座防烟楼梯间，一部消防电梯。消防技术服务机构对该建筑进行检查，下列检查结果中不符合规范要求的是（ ）。",[463,465,467,469,471],{"key":20,"text":464,"correct":26},"最不利点消火栓栓口动压不应小于0．35Mpa",{"key":24,"text":466,"correct":22},"户内设置了轻便消防水龙，并配置了公称直径25mm有内衬里的消防水带，长度为25m",{"key":28,"text":468,"correct":26},"每层设置了一个室内消火栓",{"key":31,"text":470,"correct":22},"室内消火栓配置了喷嘴直径为13mm的消防水枪",{"key":97,"text":472,"correct":26},"最不利点消火栓的充实水柱不小于13m",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},935972,"某洒水喷头上标有GB 2K-ZSTBX20-68℃，则关于该喷头的说法，不正确的是（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":26},"该喷头是快速响应喷头",{"key":24,"text":480,"correct":26},"该喷头是下垂安装",{"key":28,"text":482,"correct":22},"该喷头要直立安装",{"key":31,"text":484,"correct":26},"该喷头公称口径为20mm",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":31,"analysis":33},935973,"某施工单位对新进场的800只闭式喷头进行密封性能试验，下列做法中错误的是（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":26},"随机抽取8只喷头进行试验",{"key":24,"text":492,"correct":26},"试验压力为3MPa",{"key":28,"text":494,"correct":26},"试验保压时间为4min",{"key":31,"text":496,"correct":22},"当有两只喷头不合格时，应再抽查16只喷头进行试验",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":31,"analysis":33},935974,"某施工单位对报警阀进行密封性试验，试验压力应为额定工作压力的（ ）倍，保压时间不应小于（ ）min。",[501,502,504,505],{"key":20,"text":251,"correct":26},{"key":24,"text":503,"correct":26},"2，3",{"key":28,"text":249,"correct":26},{"key":31,"text":506,"correct":22},"2，5",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":28,"analysis":33},935975,"下列关于报警阀结构检查的说法中，错误的是（ ）。",[511,513,515,517],{"key":20,"text":512,"correct":26},"阀体上应设有放水口，放水口的公称直径不小应于20mm",{"key":24,"text":514,"correct":26},"阀体内清洁、无异物堵塞，报警阀阀瓣开启后应能够复位",{"key":28,"text":516,"correct":22},"干式报警阀组、雨淋报警阀组应设有自动排气阀",{"key":31,"text":518,"correct":26},"阀体的阀瓣组件的供水侧，应设有在不开启阀门的情况下测试报警装置的测试管路",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":31,"analysis":33},935976,"某建筑设置湿式自动喷水灭火系统保护，建筑内共安装300只喷头。某消防技术服务机构根据《自动喷水灭火系统施工及验收规范》GB 50261—2017的规定对喷头的规格、型号是否符合设计要求进行检查，抽查的喷头数量和合格数量分别为（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":26},"15，14",{"key":24,"text":526,"correct":26},"20，30",{"key":28,"text":528,"correct":26},"30，30",{"key":31,"text":530,"correct":22},"40，40",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":31,"analysis":33},935977,"对水流指示器进行现场功能性检查，当试验压力为1．0MPa，流量达到（ ）L／min时，必须报警。",[535,537,539,541],{"key":20,"text":536,"correct":26},"15",{"key":24,"text":538,"correct":26},"20",{"key":28,"text":540,"correct":26},"27．5",{"key":31,"text":542,"correct":22},"37．5",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":20,"analysis":33},935978,"当自动喷水灭火系统喷头的公称直径小于10mm时，应在自动喷水灭火系统的配水干管或配水管上安装（ ）。",[547,549,550,552],{"key":20,"text":548,"correct":22},"过滤器",{"key":24,"text":369,"correct":26},{"key":28,"text":551,"correct":26},"水流指示器",{"key":31,"text":365,"correct":26},{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":28,"analysis":33},935979,"按照施工过程质量控制要求，自动喷水灭火系统施工前应对采用的系统组件、管件及其他设备、材料进行现场检查。根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017的规定，下列说法中错误的是（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":26},"报警阀组应经国家消防产品质量监督检验中心检测合格",{"key":24,"text":560,"correct":26},"压力开关应经国家消防产品质量监督检验中心检测合格",{"key":28,"text":562,"correct":22},"自动排气阀应经国家消防产品质量监督检验中心检测合格",{"key":31,"text":564,"correct":26},"水流指示器应经国家消防产品质量监督检验中心检测合格",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":28,"analysis":33},935980,"下列有关自动喷水灭火系统组件安装要求的说法中，不正确的是（ ）。",[569,571,573,575],{"key":20,"text":570,"correct":26},"在宽度为1．4m的通风管道腹面下部增设喷头时，若喷头的上方有孔洞，可在喷头的上方设置挡水板",{"key":24,"text":572,"correct":26},"报警阀安装在室内时，室内地面应增设排水设施",{"key":28,"text":574,"correct":22},"干式报警阀组充气管道的直径不应大于15mm",{"key":31,"text":576,"correct":26},"湿式报警阀组的报警水流通路上的过滤器应安装在延迟器前",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":31,"analysis":33},935981,"下列关于干式报警阀组组件安装位置的说法中，错误的是（ ）。",[581,583,585,587],{"key":20,"text":582,"correct":26},"加速器应安装在靠近报警阀的位置",{"key":24,"text":584,"correct":26},"安全排气阀应安装在气源与报警阀之间，且应靠近报警阀",{"key":28,"text":586,"correct":26},"低气压预报警装置应安装在配水干管一侧",{"key":31,"text":588,"correct":22},"充气连接管接口应在报警阀气室充注水位以下部位且充气连接管的直径不应小于15mm",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":20,"analysis":33},935982,"在湿式自动喷水灭火系统中，过滤器安装在报警水流管路上时，应安装在（ ）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"延迟器前",{"key":24,"text":596,"correct":26},"延迟器后",{"key":28,"text":598,"correct":26},"压力开关后",{"key":31,"text":600,"correct":26},"水力警铃后",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":24,"analysis":33},935983,"下列关于水流指示器安装要求的说法中，错误的是（ ）。",[605,607,609,611],{"key":20,"text":606,"correct":26},"管道试压和冲洗合格后，方可安装水流指示器",{"key":24,"text":608,"correct":22},"水流指示器安装后，应使其浆片、膜片固定牢靠，不应摆动，并不应与管壁发生碰擦",{"key":28,"text":610,"correct":26},"水流指示器电器元件部位竖直安装在水平管道上侧，其动作方向与水流方向一致",{"key":31,"text":612,"correct":26},"信号阀安装在水流指示器前的管道上，与水流指示器间的距离不宜小于300mm",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":28,"analysis":33},935984,"某消防工程施工单位对安装完成的湿式自动喷水灭火系统进行检测，检测结果如下，其中不符合现行国家技术标准的是（ ）。",[617,619,621,623],{"key":20,"text":618,"correct":26},"打开末端试水装置，水泵在3min内启动",{"key":24,"text":620,"correct":26},"按下手动控制盘上启泵按钮，消防水泵在50s内投入正常运行",{"key":28,"text":622,"correct":22},"以备用泵切换启动消防水泵时，消防水泵在5min内投入使用",{"key":31,"text":624,"correct":26},"消防水泵停泵时，水锤消除设施后的压力为水泵出口额定压力的1．2倍",{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":28,"analysis":33},935985,"自动喷水灭火系统的喷头应有一定的备用量，喷头的备用量应不少于系统安装喷头总数的（ ），且每种备用喷头数量不应少于（ ）个。",[629,631,633,635],{"key":20,"text":630,"correct":26},"1％，5",{"key":24,"text":632,"correct":26},"2％，5",{"key":28,"text":634,"correct":22},"1％，10",{"key":31,"text":636,"correct":26},"2％，10",{"id":638,"libraryId":5,"type":15,"typeLabel":16,"stem":639,"options":640,"answer":24,"analysis":33},935986,"在自动喷水灭火系统周期性检查维护管理中，下列不属于月度检查的是（ ）。",[641,643,645,647],{"key":20,"text":642,"correct":26},"系统控制阀门铅封、锁链的检查",{"key":24,"text":644,"correct":22},"室外阀门井中进水管上的控制阀门检查",{"key":28,"text":646,"correct":26},"电磁阀的启动测试",{"key":31,"text":648,"correct":26},"消防水泵启动测试",[650,653,656,659,662,665],{"id":15,"name":651,"category":7,"favorite":652},"领导干部任职前廉政法规知识测试题",92,{"id":654,"name":655,"category":7,"favorite":15},595,"建筑结构与设备",{"id":657,"name":658,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":660,"name":661,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":663,"name":664,"category":7,"favorite":8},534,"BIM工程师",{"id":666,"name":664,"category":7,"favorite":8},535]