[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":643},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,25,50,2974,[13,34,52,67,82,96,111,126,138,150,162,172,184,196,208,220,232,244,256,270,282,293,305,317,329,341,353,365,373,385,397,409,419,434,448,460,472,484,496,511,523,535,547,559,571,583,595,607,619,631],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},935887,1,"单选题","水泵机组基础的顶面标高，无隔振安装时应高出泵房地面不小于（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","0．05m",false,{"key":24,"text":25,"correct":26},"B","0．10m",true,{"key":28,"text":29,"correct":22},"C","0．20m",{"key":31,"text":32,"correct":22},"D","0．25m","",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":51,"analysis":33},935888,2,"多选题","某建筑，室内消防采用临时高压消防给水系统联合供水，室外供水管道采用DN200球墨铸铁管道，埋地敷设，长度为3000m。经检测，室外管网漏水率为3．6L／（min·km），室内管网漏水量为0．2L／s，则该系统管网总泄漏量和稳压泵设计流量正确的有（ ）。",[40,42,44,46,48],{"key":20,"text":41,"correct":26},"管网泄漏量0．38L／s，稳压泵设计流量1 L／s",{"key":24,"text":43,"correct":22},"管网泄漏量0．20L／s，稳压泵设计流量0．79L／s",{"key":28,"text":45,"correct":22},"管网泄漏量0．38L／s，稳压泵设计流量0．56L／s",{"key":31,"text":47,"correct":26},"管网泄漏量0．38L／s，稳压泵设计流量1．5L／s",{"key":49,"text":50,"correct":22},"E","管网泄漏量0．20L／s，稳压泵设计流量1L／s","AD",{"id":53,"libraryId":5,"type":36,"typeLabel":37,"stem":54,"options":55,"answer":66,"analysis":33},935889,"某消防检测机构对消防水泵和稳压泵等供水设施进行维护管理时，下列检查项目中属于月度检查内容的有（ ）。",[56,58,60,62,64],{"key":20,"text":57,"correct":26},"手动启动消防水泵运转一次",{"key":24,"text":59,"correct":26},"手动启动柴油机消防水泵运行一次",{"key":28,"text":61,"correct":22},"对柴油机消防水泵的启动电池的电量进行检测",{"key":31,"text":63,"correct":22},"稳压泵的停泵启泵压力和启泵次数进行检查和记录运行情况",{"key":49,"text":65,"correct":26},"气压水罐的压力和有效容积进行一次检测","ABE",{"id":68,"libraryId":5,"type":36,"typeLabel":37,"stem":69,"options":70,"answer":81,"analysis":33},935890,"阀门是控制消防系统管道内水的流动方向、流量及压力的，是具有可动机构的机械，是消防给水系统中不可缺少的部件。在消防给水管网的安装过程中，阀门的选用应根据（ ）来选择。",[71,73,75,77,79],{"key":20,"text":72,"correct":26},"介质的性质",{"key":24,"text":74,"correct":26},"最大工作压力",{"key":28,"text":76,"correct":26},"最高工作温度",{"key":31,"text":78,"correct":26},"介质的流量",{"key":49,"text":80,"correct":22},"介质的流动方向","ABCD",{"id":83,"libraryId":5,"type":36,"typeLabel":37,"stem":84,"options":85,"answer":81,"analysis":33},935891,"根据《消防给水及消火栓系统技术规范》GB 50974—2014，下列关于架空管道的施工安装要求中，正确的是（ ）。",[86,88,90,92,94],{"key":20,"text":87,"correct":26},"消防给水管穿过地下室外墙、构筑物墙壁以及屋面等有防水要求处时，应设防水套管",{"key":24,"text":89,"correct":26},"消防给水管穿过建筑物承重墙或基础时，应预留洞口，洞口高度应保证管顶上部净空不小于建筑物的沉降量，不宜小于0．1m",{"key":28,"text":91,"correct":26},"消防给水管穿过墙体或楼板时应加设套管，套管长度不应小于墙体厚度，或应高出楼面或地面50mm",{"key":31,"text":93,"correct":26},"消防给水管必须穿过伸缩缝及沉降缝时，应采用波纹管和补偿器等技术措施",{"key":49,"text":95,"correct":22},"所有的消防给水管均应采取防冻技术措施",{"id":97,"libraryId":5,"type":36,"typeLabel":37,"stem":98,"options":99,"answer":110,"analysis":33},935892,"某商业中心有五栋建筑，分别为 A、 B、 C、 D、 E，五栋建筑均采用消防水泵串联分区供水形式，分高、低两个分区，维保单位对该商业中心进行检查，下列检查不符合规范要求的是（ ）。",[100,102,104,106,108],{"key":20,"text":101,"correct":26},"建筑采用消防水泵直接串联分区供水，检测时消防水泵从高区到低区依次顺序启动",{"key":24,"text":103,"correct":26},"建筑采用消防水泵直接串联分区供水，在串联消防水泵吸水管上设置了减压型倒流防止器",{"key":28,"text":105,"correct":26},"中间转输水箱的有效储水容积为18m3",{"key":31,"text":107,"correct":22},"转输水箱兼做低区的高位消防水箱",{"key":49,"text":109,"correct":22},"串联转输水箱的溢流管连接到底部的消防水池","ABC",{"id":112,"libraryId":5,"type":36,"typeLabel":37,"stem":113,"options":114,"answer":125,"analysis":33},935893,"根据《消防给水及消火栓系统技术规范》GB 50974—2014，下列关于沟槽连接件（卡箍）的施工安装要求中，正确的是（ ）。",[115,117,119,121,123],{"key":20,"text":116,"correct":26},"配水干管（立管）与配水管（水平管）连接，应采用沟槽式管件，不应采用机械三通",{"key":24,"text":118,"correct":22},"埋地的沟槽式管件的螺栓、螺帽应做防腐处理，水泵房内的埋地管道连接不应采用挠性接头",{"key":28,"text":120,"correct":22},"沟槽式管件的凸边应卡进沟槽后再紧固螺栓，应先紧固一边后，再紧固另一边，紧固时发现橡胶圈起皱应更换新橡胶圈",{"key":31,"text":122,"correct":26},"机械三通开孔间距不应小于1m，机械四通开孔间距不应小于2m",{"key":49,"text":124,"correct":26},"有振动的场所和埋地管道应采用柔性接头，当采用刚性接头时，每隔4个～5个刚性接头应设置一个挠性接头","ADE",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":31,"analysis":33},935894,"对于重点部位消火栓，（ ）应逐一进行一次出水试验，出水应满足压力要求。",[130,132,134,136],{"key":20,"text":131,"correct":22},"每日",{"key":24,"text":133,"correct":22},"每月",{"key":28,"text":135,"correct":22},"每季",{"key":31,"text":137,"correct":26},"每年",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},935895,"下列关于消防给水及消火栓系统安装完毕后检查数量的说法，不正确的是（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":26},"消防水泵接合器按数量抽查30％，但不应小于10个",{"key":24,"text":145,"correct":22},"室外消火栓按数量抽查30％，但不应小于10个",{"key":28,"text":147,"correct":22},"室内消火栓按数量抽查30％，但不应小于10个",{"key":31,"text":149,"correct":22},"消火栓箱按数量抽查30％，但不应小于10个",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},935896,"根据《消防给水及消火栓系统技术规范》（GB 50974）的规定，下列日常维护管理正确的是（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"每年应监测市政给水管网的压力和供水能力",{"key":24,"text":157,"correct":26},"每季度应该对消火栓进行一次外观和漏水检查，发现有不正常的消火栓应及时更换",{"key":28,"text":159,"correct":22},"在冬季每月应对消防储水设施进行室内温度和水温检测，当结冰或室内温度低于5℃时，应采取确保不结冰和室温不低于5℃的措施",{"key":31,"text":161,"correct":22},"每季度应该对消火栓进行一次水压强度试验检查，发现有不正常的消火栓应及时更换",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":24,"analysis":33},935897,"对室内消火栓箱内的消防水枪、消防水带、消防卷盘及其他配件应（ ）进行一次检查，全部附件应齐全完好，卷盘转动灵活，发现存在问题的应及时修复、更换或补充。",[166,167,169,171],{"key":20,"text":133,"correct":22},{"key":24,"text":168,"correct":26},"每半年",{"key":28,"text":170,"correct":22},"每季度",{"key":31,"text":137,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},935898,"对某建筑内安装完毕的室内消火栓系统进行验收，下列验收结果中，符合相关规范规定的是（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"建筑物内设置的消火栓只能采用同一品牌",{"key":24,"text":179,"correct":26},"水泵控制柜打在自动状态，按下水泵控制柜上的启动按钮，水泵启动",{"key":28,"text":181,"correct":22},"设有试验用消火栓，但栓口处未设置压力表",{"key":31,"text":183,"correct":22},"消火栓栓口中心距地面的高度为1．1m，并设置在靠近门轴的一侧",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":24,"analysis":33},935899,"某高层综合楼内设置消火栓系统，消火栓总数为140个，消防机构对该建筑内消火栓进行验收，根据《消防给水及消火栓系统技术规范》GB 50974—2014，应至少抽查（ ）个消火栓。",[188,190,192,194],{"key":20,"text":189,"correct":22},"10",{"key":24,"text":191,"correct":26},"14",{"key":28,"text":193,"correct":22},"16",{"key":31,"text":195,"correct":22},"28",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":31,"analysis":33},935900,"下面关于消防水带、水枪、消火栓固定接口的说法，错误的是（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":22},"设计工作压力为1．0MPa的消防水带在压力试验时，爆破压力低于3．0MPa则认为水带压力试验不合格",{"key":24,"text":203,"correct":22},"消防水枪的抗跌落性能试验应以喷嘴垂直朝上、喷嘴垂直朝下、消防水枪轴线水平三个位置从离地2．0±0．02m的高度自由跌落到混凝土地面，每个位置跌落两次",{"key":28,"text":205,"correct":22},"消火栓固定接口密封性能试验，试验压力为1．6MPa，保压时间2min",{"key":31,"text":207,"correct":26},"水枪密封性能试验，试验压力为最大工作压力的2倍，保压时间2min",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":20,"analysis":33},935901,"某服装仓库，地上3层，仓库平面尺寸为25×15m,建筑高度12m，则该仓库至少需要设置（ ）个室内消火栓。",[212,214,216,218],{"key":20,"text":213,"correct":26},"3",{"key":24,"text":215,"correct":22},"6",{"key":28,"text":217,"correct":22},"9",{"key":31,"text":219,"correct":22},"12",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":31,"analysis":33},935902,"某工程室内消火栓施工完毕后，对消火栓进行施工质量检查，发现的以下情况不符合消防技术标准的是（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"栓口与设置消火栓的墙面垂直",{"key":24,"text":227,"correct":22},"消火栓栓口中心距地高度为1．1 m",{"key":28,"text":229,"correct":22},"消火栓箱门的开启角度为125°",{"key":31,"text":231,"correct":26},"消火栓栓口安装在门轴侧",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":24,"analysis":33},935903,"室内消火栓管井的消防立管安装采用（ ）的安装方法。",[236,238,240,242],{"key":20,"text":237,"correct":22},"从上至下",{"key":24,"text":239,"correct":26},"从下至上",{"key":28,"text":241,"correct":22},"从左至右",{"key":31,"text":243,"correct":22},"从右至左",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":28,"analysis":33},935904,"常用的SN65型手轮直径不小于（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"100mm",{"key":24,"text":251,"correct":22},"110mm",{"key":28,"text":253,"correct":26},"120mm",{"key":31,"text":255,"correct":22},"130mm",{"id":257,"libraryId":5,"type":36,"typeLabel":37,"stem":258,"options":259,"answer":81,"analysis":33},935905,"某消防设施检测机构对某二类高层公共建筑内安装结束的消火栓系统进行验收前的检测，下列检查结果中，不符合现行国家消防技术标准的是（ ）。",[260,262,264,266,268],{"key":20,"text":261,"correct":26},"消火栓栓口安装在门轴侧，并与墙面成90°角",{"key":24,"text":263,"correct":26},"室内管网上涂有红色环圈标志，环圈之间间隔距离为6m",{"key":28,"text":265,"correct":26},"首层外墙上安装有墙壁式消防水泵接合器，接合器距地面的高度为0．7m，距左侧窗的距离为1m",{"key":31,"text":267,"correct":26},"室内采用DN65的消火栓和喷嘴为13mm的消防水枪",{"key":49,"text":269,"correct":22},"消防水泵出水管上安装水锤消除器",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":28,"analysis":33},935906,"下列不属于按消防水带使用功能分类的是（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"消防湿水带",{"key":24,"text":277,"correct":22},"抗静电消防水带",{"key":28,"text":279,"correct":26},"平纹消防水带",{"key":31,"text":281,"correct":22},"水幕水带",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":28,"analysis":33},935907,"某有衬里消防水带设计工作压力为1．6MPa，对该水带进行压力试验，则其最小爆破压力应为（ ）MPa。",[286,288,289,291],{"key":20,"text":287,"correct":22},"2．4",{"key":24,"text":213,"correct":22},{"key":28,"text":290,"correct":26},"4．8",{"key":31,"text":292,"correct":22},"5",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":28,"analysis":33},935908,"下列关于室内消火栓系统管网试压和冲洗的顺序，正确的是（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":22},"严密性试验—强度试验—冲洗",{"key":24,"text":300,"correct":22},"冲洗—强度试验—严密性试验",{"key":28,"text":302,"correct":26},"强度试验—冲洗—严密性试验",{"key":31,"text":304,"correct":22},"强度试验—严密性试验—冲洗",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":28,"analysis":33},935909,"每（ ）应对消火栓进行一次外观和漏水检查，发现有不正常的消火栓应及时更换。",[309,311,313,315],{"key":20,"text":310,"correct":22},"日",{"key":24,"text":312,"correct":22},"月",{"key":28,"text":314,"correct":26},"季度",{"key":31,"text":316,"correct":22},"年",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":33},935910,"下列有关消火栓的现场检验说法中，不正确的是（ ）。",[321,323,325,327],{"key":20,"text":322,"correct":22},"消火栓螺纹密封面应无伤痕、毛刺、缺丝或断丝现象",{"key":24,"text":324,"correct":26},"旋转型消火栓其内部构造应合理，转动部件应为球墨铸铁",{"key":28,"text":326,"correct":22},"减压稳压消火栓应保证可靠、无堵塞现象",{"key":31,"text":328,"correct":22},"活动部件应转动灵活，材料应耐腐蚀，不应卡涩或脱扣",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":28,"analysis":33},935911,"下列关于室内消火栓维护管理的说法中，错误的是（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"每半年对消火栓、供水阀门及消防卷盘等所有转动部位应定期加注润滑油",{"key":24,"text":336,"correct":22},"每半年检查消火栓和消防卷盘供水闸阀是否渗漏水，若渗漏水及时更换密封圈",{"key":28,"text":338,"correct":26},"每年对消防水枪、水带、消防卷盘及其他进行检查，全部附件应齐全完好，卷盘转动灵活",{"key":31,"text":340,"correct":22},"每半年对报警按钮、指示灯及控制线路进行检查，其功能应正常、无故障",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":20,"analysis":33},935912,"下列关于室内消火栓及栓箱的说法，不正确的是（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":26},"一般室内消火栓的栓座材料性能不应低于铅黄铜，阀杆本体材料的性能不低于黄铜",{"key":24,"text":348,"correct":22},"室内消火栓的箱门材料可以采用全钢型也可以采用铝合金框玻璃型",{"key":28,"text":350,"correct":22},"消防水带可以采用拖架式置于消火栓箱中",{"key":31,"text":352,"correct":22},"室内消火栓常用的SN65型手轮的直径不小于120mm",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":28,"analysis":33},935913,"在检查消防水枪的抗跌落性能时，应将水枪以喷嘴垂直朝上、喷嘴垂直朝下，以及水枪轴线处于水平三个位置，从离地（ ）m高处自由跌落到混凝土地面上。",[357,359,361,363],{"key":20,"text":358,"correct":22},"1．0±0．01",{"key":24,"text":360,"correct":22},"1．5±0．02",{"key":28,"text":362,"correct":26},"2．0±0．02",{"key":31,"text":364,"correct":22},"3．0±0．03",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},935914,"根据《消防给水及消火栓系统技术规范》（GB 50974），对室内消火栓应（ ）进行一次外观和漏水检查，发现存在问题的消火栓应及时修复或更换。",[369,370,371,372],{"key":20,"text":170,"correct":26},{"key":24,"text":133,"correct":22},{"key":28,"text":168,"correct":22},{"key":31,"text":137,"correct":22},{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":28,"analysis":33},935915,"室外消火栓的分类按其进水口连接形式可分为承插式和法兰式两种，其中承插式的消火栓公称压力为（ ）MPa。",[377,379,381,383],{"key":20,"text":378,"correct":22},"0．5",{"key":24,"text":380,"correct":22},"0．7",{"key":28,"text":382,"correct":26},"1．0",{"key":31,"text":384,"correct":22},"1．6",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":31,"analysis":33},935916,"下列不属于消防水枪按照喷水方式分类的是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":22},"直流水枪",{"key":24,"text":392,"correct":22},"喷雾水枪",{"key":28,"text":394,"correct":22},"多用途水枪",{"key":31,"text":396,"correct":26},"高压水枪",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},935917,"根据《消防给水及消火栓系统技术规范》下列关于消火栓箱安装的说法中，错误的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"消火栓箱门上应用注明“消火栓”字样",{"key":24,"text":404,"correct":22},"消火栓的启闭阀门设置位置应便于操作使用，阀门的中心距箱侧面应为140mm，距箱后内表面应为100mm，允许偏差±5mm",{"key":28,"text":406,"correct":26},"消火栓箱只能采用明装，不能采用暗装",{"key":31,"text":408,"correct":22},"消火栓箱门的开启不应小于120°",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":31,"analysis":33},935918,"在对消防接口进行安装前检查时，应进行抗跌落性能试验，反复进行（ ）次后，检查接口是否有断裂现象，并进行操作，如消防接口跌落后出现断裂或不能正常操纵使用的，则判定该产品不合格。",[413,415,416,418],{"key":20,"text":414,"correct":22},"2",{"key":24,"text":213,"correct":22},{"key":28,"text":417,"correct":22},"4",{"key":31,"text":292,"correct":26},{"id":420,"libraryId":5,"type":36,"typeLabel":37,"stem":421,"options":422,"answer":433,"analysis":33},935919,"下列有关消火栓箱的分类中，按箱门型式分类的有（ ）。",[423,425,427,429,431],{"key":20,"text":424,"correct":26},"左开门式",{"key":24,"text":426,"correct":26},"右开门式",{"key":28,"text":428,"correct":26},"双开门式",{"key":31,"text":430,"correct":22},"上下开门式",{"key":49,"text":432,"correct":26},"前后开门式","ABCE",{"id":435,"libraryId":5,"type":36,"typeLabel":37,"stem":436,"options":437,"answer":51,"analysis":33},935920,"某多层商场建筑高度为22．5m，每层建筑面积为1500㎡，屋顶设有高位消防水箱及增压稳压设施，某消防服务机构的工作人员对建筑内安装完成的湿式室内消火栓系统进行检测，下列检测结果中，符合现行国家技术标准的是（ ）。",[438,440,442,444,446],{"key":20,"text":439,"correct":26},"打开试验消火栓放水，消防水泵在90s内启动",{"key":24,"text":441,"correct":22},"查看消防水泵出水管上的压力表，发现压力表的量程为设计工作压力的1．2倍",{"key":28,"text":443,"correct":22},"测试最不利点消火栓处的静水压力为0．1 MPa",{"key":31,"text":445,"correct":26},"高位消防水箱出水管上旋流防止器的淹没深度为200mm",{"key":49,"text":447,"correct":22},"配水干管与配水管之间采用机械三通连接",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":28,"analysis":33},935921,"下列关于室内消火栓的施工安装要求的说法中，不正确的是（ ）。",[452,454,456,458],{"key":20,"text":453,"correct":22},"消火栓栓口出水方向宜向下或与设置消火栓的墙面成90。角",{"key":24,"text":455,"correct":22},"消火栓栓口中心距地面应为1．1m，允许偏差±20mm",{"key":28,"text":457,"correct":26},"同一建筑物内设置的消火栓、消防软管卷盘和轻便水龙应采用同一品牌的栓口、消防水枪和水带及配件",{"key":31,"text":459,"correct":22},"试验用消火栓栓口处应设置压力表",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},935922,"某消防工程施工单位对消火栓系统进行施工前的经常检验，根据《消防给水及消火栓系统技术规范》（GB50974—2014），关于消火栓固定接口密封性能现场试验的说法中，正确的是（）。",[464,466,468,470],{"key":20,"text":465,"correct":22},"试验数量宜从每批中抽查1％，但不应少于3个",{"key":24,"text":467,"correct":26},"当仅有1个不合格时，应再抽查2％，但不应少于10个",{"key":28,"text":469,"correct":22},"应缓慢而均匀地升压1．6MPa，并应保压1min",{"key":31,"text":471,"correct":22},"当第2次抽查仍有不合格时，应继续进行批量抽查，抽查数量按前次递增",{"id":473,"libraryId":5,"type":36,"typeLabel":37,"stem":474,"options":475,"answer":81,"analysis":33},935923,"消防水带按承受工作压力可分为（）MPa、2．0MPa、2．5MPa工作压力的消防水带。",[476,478,479,481,482],{"key":20,"text":477,"correct":26},"0．8",{"key":24,"text":382,"correct":26},{"key":28,"text":480,"correct":26},"1．3",{"key":31,"text":384,"correct":26},{"key":49,"text":483,"correct":22},"1．8",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":31,"analysis":33},935924,"某建筑安装的室内消火栓系统的设计工作压力为0．8MPa，现在对此系统给水网管进行水压测试。检测人员的下列做法中，错误的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"水压强度试验的试验压力为1．4MPa",{"key":24,"text":491,"correct":22},"水压强度试验的测试点设在系统管网的最低点",{"key":28,"text":493,"correct":22},"对管网注水时，应将管网内的空气排净，缓慢升压，达到试验压力后，稳压30min后观察管网的泄露变形情况",{"key":31,"text":495,"correct":26},"进行水压严密性试验的试验压力为0．8MPa，稳压12h后观察泄露情况",{"id":497,"libraryId":5,"type":36,"typeLabel":37,"stem":498,"options":499,"answer":510,"analysis":33},935925,"下列关于消防给水系统采用减压阀减压分区供水时的设置要求中，不正确的是（ ）。",[500,502,504,506,508],{"key":20,"text":501,"correct":22},"减压阀前后应设压力表",{"key":24,"text":503,"correct":26},"减压阀前应设置安全阀",{"key":28,"text":505,"correct":26},"减压阀前后应设置过滤器",{"key":31,"text":507,"correct":22},"过滤器前和减压阀后应设置控制阀门",{"key":49,"text":509,"correct":26},"减压阀前应设置压力试验排水阀","BCE",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":20,"analysis":33},935926,"下列有关室外消火栓检查的说法中，错误的是（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":26},"外螺纹固定接口和吸水管接口的本体材料应由球墨铸铁制造",{"key":24,"text":518,"correct":22},"合格的室外消火栓应在阀体或阀盖上铸出型号、规格和商标且与检验报告描述一致",{"key":28,"text":520,"correct":22},"室外消火栓应有自动排放余水装置",{"key":31,"text":522,"correct":22},"栓阀座应用铸造铜合金，阀杆螺母材料性能应不低于黄铜",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},935927,"按照施工过程质量控制要求，消火栓系统安装前应对采用的主要设备、系统组件、管材管件及其他设备、材料进行现场检验。根据现行国家标准《消防给水及消火栓系统技术规范》（GB 50974—2014）规定，下列说法中错误的是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":26},"消火栓管材管件应经国家消防产品质量监督检验中心检验合格",{"key":24,"text":530,"correct":22},"消防水枪应经国家消防产品质量监督检验中心检验合格",{"key":28,"text":532,"correct":22},"消防水带应经国家消防产品质量监督检验中心检验合格",{"key":31,"text":534,"correct":22},"消火栓应经国家消防产品质量监督检验中心检验合格",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},935928,"某施工单位对一批室内消火栓系统组件、管件及其他设备进行安装前检查，下列检查结果中不符合规范要求的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"室内消火栓阀体和阀盖上铸出型号、规格和商标，与检验报告描述一致",{"key":24,"text":542,"correct":26},"采用SN65型手轮直径为100mm",{"key":28,"text":544,"correct":22},"室内消火栓手轮轮缘上铸有标示开关方向的箭头和字样",{"key":31,"text":546,"correct":22},"室内消火栓阀座材料为铜合金铸造",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":31,"analysis":33},935929,"对消火栓箱箱体外观质量和标志进行检查，下列不属于消火栓箱箱体耐久铭牌上内容的是（ ）。",[551,553,555,557],{"key":20,"text":552,"correct":22},"产品型号",{"key":24,"text":554,"correct":22},"注册商标或厂名",{"key":28,"text":556,"correct":22},"生产日期",{"key":31,"text":558,"correct":26},"使用单位名称",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":33},935930,"下列关于消防水枪抗跌落性能检测时的做法中，符合规范规定的是（ ）。",[563,565,567,569],{"key":20,"text":564,"correct":22},"水枪以喷嘴垂直朝上从距地（2．0±0．02）m高处自由跌落一次",{"key":24,"text":566,"correct":26},"喷嘴垂直朝下距地（2．0±0．02）m高处自由跌落两次",{"key":28,"text":568,"correct":22},"水枪轴线处于水平位置距地（2．0±0．02）m高处自由跌落一次",{"key":31,"text":570,"correct":22},"水枪随机从距地（2．2±0．02）m高处自由跌落一次",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":28,"analysis":33},935931,"某高层综合楼，地上14层，层高4．2m，设有高位消防水箱，室内消火栓设计流量为35L／s，对室内消火栓系统进行检查和检测时，下列情况符合规定的是（ ）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"打开试验消火栓时，测得动压为0．3MPa",{"key":24,"text":578,"correct":22},"消火栓箱门打开时，开启角度为100°",{"key":28,"text":580,"correct":26},"测得最不利点消火栓处的静压为0．12MPa",{"key":31,"text":582,"correct":22},"消火栓栓口到每层楼板的高度为0．7m",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":24,"analysis":33},935932,"室内消火栓按结构型式分类时，不包括（ ）。",[587,589,591,593],{"key":20,"text":588,"correct":22},"直角出口型室内消火栓",{"key":24,"text":590,"correct":26},"双出口室内消火栓",{"key":28,"text":592,"correct":22},"45°出口型室内消火栓",{"key":31,"text":594,"correct":22},"旋转减压型室内消火栓",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":24,"analysis":33},935933,"下列关于消防水枪抗跌落性能检查的说法中，正确的是（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"水枪应从距地（1．5±0．02）m高处自由跌落",{"key":24,"text":602,"correct":26},"水枪应从距地（2．0±0．02）m高处自由跌落",{"key":28,"text":604,"correct":22},"水枪应从距地（1．8±0．02）m高处自由跌落",{"key":31,"text":606,"correct":22},"水枪应从距地（2．2±0．02）m高处自由跌落",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":20,"analysis":33},935934,"地下式室外消火栓适用于（ ）地区。",[611,613,615,617],{"key":20,"text":612,"correct":26},"较寒冷",{"key":24,"text":614,"correct":22},"较潮湿",{"key":28,"text":616,"correct":22},"气温较高",{"key":31,"text":618,"correct":22},"较干燥",{"id":620,"libraryId":5,"type":15,"typeLabel":16,"stem":621,"options":622,"answer":28,"analysis":33},935935,"下列有关消防水带检查的说法中，错误的是（ ）。",[623,625,627,629],{"key":20,"text":624,"correct":22},"对照水带的3C认证型式检验报告，看该产品名称、型号、规格是否一致",{"key":24,"text":626,"correct":22},"合格水带的织物层应编织均匀，表面整洁，无跳双经、断双经、跳纬及划伤",{"key":28,"text":628,"correct":26},"水带长度检查时，水带长度小于水带长度规格0．5m以上的，则可以判该产品为不合格",{"key":31,"text":630,"correct":22},"消防水带的压力试验应截取1．2m长的水带，使用手动试压泵或电动试压泵平稳加压至试验压力，保压5min，检查是否有渗漏现象",{"id":632,"libraryId":5,"type":15,"typeLabel":16,"stem":633,"options":634,"answer":31,"analysis":33},935936,"下列有关室内消火栓管道安装的说法中，错误的是（ ）。",[635,637,639,641],{"key":20,"text":636,"correct":22},"水压强度试验的测试点应设在系统管网的最低点",{"key":24,"text":638,"correct":22},"水压严密性试验应在水压强度试验和管网冲洗合格后进行",{"key":28,"text":640,"correct":22},"管道穿梁及地下室剪力墙、水池等，应在预埋金属管中穿过",{"key":31,"text":642,"correct":26},"安装顺序一般是主干管、干管、分支管、垂直管、横管",[644,647,650,653,656,659],{"id":15,"name":645,"category":7,"favorite":646},"领导干部任职前廉政法规知识测试题",92,{"id":648,"name":649,"category":7,"favorite":15},595,"建筑结构与设备",{"id":651,"name":652,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":654,"name":655,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":657,"name":658,"category":7,"favorite":8},534,"BIM工程师",{"id":660,"name":658,"category":7,"favorite":8},535]