[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-24":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":651},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,24,50,2974,[13,34,46,58,70,82,94,106,124,139,154,169,183,196,211,223,235,247,259,271,283,298,313,325,337,352,366,378,390,402,414,426,438,450,462,474,485,497,509,521,532,544,556,568,580,592,604,616,627,639],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},935837,1,"单选题","消防给水系统的维护管理是确保系统正常完好、有效使用的基本保障。对消防水源进行维护管理时，下列做法不符合要求的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","每季度监测市政给水管网的压力和供水能力",false,{"key":24,"text":25,"correct":22},"B","每年对水井等地下水消防水源的常水位、最低水位、最高水位和出水量等进行一次测定",{"key":27,"text":28,"correct":29},"C","消防水池（箱）玻璃水位计两端的角阀在不进行水位观察时应开启",true,{"key":31,"text":32,"correct":22},"D","当结冰或室内温度低于5℃时，要采取确保不结冰和室温不低于5℃的措施","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},935838,"在消防给水管网的安装过程中，下列关于防晃支架设置的说法，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"管径大于DN50mm的管道拐弯、三通及四通位置处应设1个防晃支架",{"key":24,"text":41,"correct":22},"配水管宜在中点设一个防晃支架，当管径小于DN50mm时可不设",{"key":27,"text":43,"correct":22},"配水干管及配水管、配水支管的长度超过15m，每15m长度内应至少设1个防晃支架，当管径不大于DN40mm可不设",{"key":31,"text":45,"correct":29},"防晃支架的强度应满足管道、配件及管内水的重量再加20％的水平方向推力时不损坏或不产生永久变形",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},935839,"根据《消防给水及消火栓系统技术规范》（GB 50974—2014）的规定，每（ ）应对减压阀的流量和压力进行一次试验。",[50,52,54,56],{"key":20,"text":51,"correct":22},"日",{"key":24,"text":53,"correct":22},"月",{"key":27,"text":55,"correct":22},"季度",{"key":31,"text":57,"correct":29},"年",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},935840,"消防给水管道穿过建筑物承重墙或基础时，应预留洞口，洞口的高度应保证管顶上部净空不小于建筑物的沉降量，不宜小于（ ）m，并应填充不透水的弹性材料。",[62,64,66,68],{"key":20,"text":63,"correct":29},"0．1",{"key":24,"text":65,"correct":22},"0．2",{"key":27,"text":67,"correct":22},"0．3",{"key":31,"text":69,"correct":22},"0．5",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},935841,"下列设施设备在进场检查时需要检查是否经国家消防产品质量监督检验中心检测合格的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"倒流防止器",{"key":24,"text":77,"correct":22},"消防水箱",{"key":27,"text":79,"correct":29},"压力开关",{"key":31,"text":81,"correct":22},"压力表",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},935842,"根据《消防给水及消火栓系统技术规范》（GB 50974-2014）的要求，下列关于消防给水和消火栓系统维护管理的说法中，错误的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"每季度应对消火栓进行一次外观和漏水检查，发现有不正常的消火栓应及时更换",{"key":24,"text":89,"correct":29},"每半年应对消防水泵接合器的接口及附件进行一次检查，并应保证接口完好、无渗漏、闷盖齐全",{"key":27,"text":91,"correct":22},"每年应对系统过滤器进行至少一次排渣，并应检查过滤器是否处于完好状态，当堵塞或损坏时应及时检修",{"key":31,"text":93,"correct":22},"每年应检查消防水池、消防水箱等蓄水设施的结构材料是否完好，发现问题时应及时处理",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},935843,"消防水泵接合器可以补充消防水量,也可用于提高消防给水管网的水压,下列有关消防水泵接合器设置要求的说法,错误的是（ ）",[98,100,102,104],{"key":20,"text":99,"correct":22},"消防水泵接合器处应设置永久性标志铭牌,并应标明供水系统、供水范围和额定压力",{"key":24,"text":101,"correct":22},"墙壁消防水泵接合器与墙面上的门、窗、孔、洞的净距离不应小于 2.0m",{"key":27,"text":103,"correct":22},"消防水泵接合器距室外消火栓或消防水池的距离不宜小于 15m,并不宜大于 40m",{"key":31,"text":105,"correct":29},"消防水泵接合器设置的数量应按系统设计流量经计算确定,但不应超过 3 个",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},935844,2,"多选题","维护管理人员应掌握和熟悉消防给水系统的（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":29},"工作原理",{"key":24,"text":115,"correct":29},"系统性能",{"key":27,"text":117,"correct":22},"灭火机理",{"key":31,"text":119,"correct":22},"运行规律",{"key":121,"text":122,"correct":29},"E","操作规程","ABE",{"id":125,"libraryId":5,"type":108,"typeLabel":109,"stem":126,"options":127,"answer":138,"analysis":33},935845,"下列有关消防给水系统减压阀安装的说法中，正确的有（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":29},"减压阀处应有压力试验用排水设施",{"key":24,"text":131,"correct":29},"减压阀前后应安装压力表",{"key":27,"text":133,"correct":29},"减压阀前应有过滤器",{"key":31,"text":135,"correct":29},"减压阀水流方向应与供水管网水流方向一致",{"key":121,"text":137,"correct":22},"供水管网应在减压阀安装后进行试压冲洗","ABCD",{"id":140,"libraryId":5,"type":108,"typeLabel":109,"stem":141,"options":142,"answer":153,"analysis":33},935846,"下列关于消防管道安装的说法中，正确的有（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":29},"消防给水管必须穿过伸缩缝及沉降缝时，应采用波纹管和补偿器等技术措施",{"key":24,"text":146,"correct":29},"消防给水管可能发生冰冻时，应采取防冻技术措施",{"key":27,"text":148,"correct":29},"消防给水管穿过墙体或楼板时应加设套管，套管长度不应小于墙体厚度，或应高出楼面或地面50mm",{"key":31,"text":150,"correct":22},"套管与管道的间隙应采用难燃材料填塞，管道的接口不应位于套管内",{"key":121,"text":152,"correct":29},"消防给水管穿过地下室外墙、构筑物墙壁以及屋面等有防水要求处时，应设防水套管","ABCE",{"id":155,"libraryId":5,"type":108,"typeLabel":109,"stem":156,"options":157,"answer":168,"analysis":33},935847,"下列有关消防水箱检测验收的说法中，正确的有（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":29},"对照图样，用测量工具检查水池容量是否符合要求，观察有无补水措施、防冻措施以及消防用水的保证措施",{"key":24,"text":161,"correct":29},"封闭水箱在试验压力下保持10min，压力不降、不渗不漏则封闭水箱的水压试验合格",{"key":27,"text":163,"correct":22},"敞口水箱装满水静置48h后观察，若不渗不漏，则敞口水箱的满水试验合格",{"key":31,"text":165,"correct":29},"观察检查水箱溢流管和泄放管应设置在排水地点附近，但不得与排水管直接连接",{"key":121,"text":167,"correct":29},"用测量工具检查水箱安装位置及支架或底座安装情况，其尺寸及位置应符合设计要求，埋设平整牢固","ABDE",{"id":170,"libraryId":5,"type":108,"typeLabel":109,"stem":171,"options":172,"answer":153,"analysis":33},935848,"消防给水系统和各类水灭火设施测试的时候需要有排水功能，下列关于测试排水要求的说法中，正确的有（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":29},"末端试水装置处的排水立管管径，应根据末端试水装置的泄流量确定，并不宜小于DN75",{"key":24,"text":176,"correct":29},"报警阀处的排水立管宜为DN100",{"key":27,"text":178,"correct":29},"减压阀处的压力试验排水管道直径应根据减压阀流量确定，但不应小于DN100",{"key":31,"text":180,"correct":22},"每台消防水泵出水管上应设置DN75的试水管，并应采取排水措施",{"key":121,"text":182,"correct":29},"试验排水可回收部分宜排入专用消防水池循环再利用",{"id":184,"libraryId":5,"type":108,"typeLabel":109,"stem":185,"options":186,"answer":195,"analysis":33},935849,"下列关于消防给水系统减压阀的安装要求的说法中，正确的有（ ）。",[187,189,190,192,193],{"key":20,"text":188,"correct":29},"减压阀安装应在供水管网试压、冲洗合格后进行",{"key":24,"text":135,"correct":29},{"key":27,"text":191,"correct":22},"减压阀后应有过滤器",{"key":31,"text":131,"correct":29},{"key":121,"text":194,"correct":22},"减压阀处应有压力试验用排水设施，排水管直径不应小于DN75","ABD",{"id":197,"libraryId":5,"type":108,"typeLabel":109,"stem":198,"options":199,"answer":210,"analysis":33},935850,"下列关于稳压泵设置的说法中，不符合规定的有（ ）。",[200,202,204,206,208],{"key":20,"text":201,"correct":29},"稳压泵的设计流量应满足系统自动启动和管网充满水的要求",{"key":24,"text":203,"correct":22},"稳压泵的设计流量宜按消防给水系统设计流量的 1%~3%计，且不宜小于 1L\u002Fs",{"key":27,"text":205,"correct":22},"稳压泵设计压力应保持系统最不利点处灭火设施在准工作状态时的静水压力大于 0.15MPa",{"key":31,"text":207,"correct":22},"当采用气压水罐时，气压水罐有效容积不宜小于 150L",{"key":121,"text":209,"correct":29},"稳压泵吸水管应设置消声止回阀和明杆闸阀","AE",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":31,"analysis":33},935851,"某综合楼的自动喷水灭火系统的设计工作压力为0．9MPa，消防工程施工单位对系统的钢管管道进行水压试验，则该系统的水压强度试验不应低于（ ）MPa。",[215,217,219,221],{"key":20,"text":216,"correct":22},"1．35",{"key":24,"text":218,"correct":22},"1．5",{"key":27,"text":220,"correct":22},"1．3",{"key":31,"text":222,"correct":29},"1．4",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":31,"analysis":33},935852,"下列关于扑救一起火灾灭火所需的消防用水设计流量的说法中，正确的是（ ）。",[227,229,231,233],{"key":20,"text":228,"correct":22},"当消防给水与生活、生产给水合用时，合用系统的给水设计流量应按消防给水设计流量与生活、生产用水中的较大者确定",{"key":24,"text":230,"correct":22},"当消防给水与生活、生产给水合用时，计算生活用水最大小时流量时，淋浴用水量可不计",{"key":27,"text":232,"correct":22},"当消防给水与生活、生产给水合用时，计算生活用水最大小时流量时，浇洒及洗刷的用水量可按15％计入",{"key":31,"text":234,"correct":29},"建筑内同时设有室内消火栓、室外消火栓、自动喷水灭火系统时，应按需要同时作用的各种水灭火系统最大设计流量之和确定",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":27,"analysis":33},935853,"下列不属于消防水池作为消防水源条件的是（ ）。",[239,241,243,245],{"key":20,"text":240,"correct":22},"消防水池有足够的有效容积",{"key":24,"text":242,"correct":22},"在与生活或其他用水合用时，消防水池应采取确保消防用水量不作他用的技术措施",{"key":27,"text":244,"correct":29},"消防水池应采取相应的防冻措施",{"key":31,"text":246,"correct":22},"供消防车取水的消防水池应设取水口",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},935854,"根据《消防给水及消火栓系统技术规范》（GB50974—2014）的规定，室内消火栓系统管网安装完成后，对其进行水压试验和冲洗的正确顺序是（）。",[251,253,255,257],{"key":20,"text":252,"correct":22},"强度试验—严密性试验—冲洗",{"key":24,"text":254,"correct":29},"强度试验—冲洗—严密性试验",{"key":27,"text":256,"correct":22},"冲洗—强度试验—严密性试验",{"key":31,"text":258,"correct":22},"冲洗—严密性试验—强度试验",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":31,"analysis":33},935855,"某工地按《通用阀门压力试验》（GB／T13927）、《自动喷水灭火系统第6部分：通用阀门》（GB5135．6）的要求，对消防用蝶阀开展进场检验。下列检查项目中，不属于进场检验项目的是（）。",[263,265,267,269],{"key":20,"text":264,"correct":22},"外观质量检查",{"key":24,"text":266,"correct":22},"型号规格检查",{"key":27,"text":268,"correct":22},"开关指示标志",{"key":31,"text":270,"correct":29},"水头损失检查",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":27,"analysis":33},935856,"某建筑采用临时高压消防给水系统，在屋顶设置消防增压稳压设施，水箱采用封闭消防水箱，材质为不锈钢，下列关于消防水箱的施工，错误的是（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":22},"消防水箱的进出水管道采用法兰连接",{"key":24,"text":278,"correct":22},"水箱支墩高度为700mm",{"key":27,"text":280,"correct":29},"水箱要进行满水试验和水压试验",{"key":31,"text":282,"correct":22},"气压水罐四周设检修通道，其宽度为0．9m",{"id":284,"libraryId":5,"type":108,"typeLabel":109,"stem":285,"options":286,"answer":297,"analysis":33},935857,"供水设施的维护管理规定包括（）。",[287,289,291,293,295],{"key":20,"text":288,"correct":22},"每季度应手动启动消防水泵运转一次，并检查供电电源的情况",{"key":24,"text":290,"correct":29},"每周应模拟消防水泵自动控制的条件自动启动消防水泵运转一次，且自动记录自动巡检情况，每月应检测记录",{"key":27,"text":292,"correct":29},"每日对稳压泵的停泵启泵压力和启泵次数等进行检查和记录运行情况",{"key":31,"text":294,"correct":29},"每日对柴油机消防水泵的启动电池的电量进行检测，每周检查储油箱的储油量，每月应手动启动柴油机消防水泵运行一次",{"key":121,"text":296,"correct":22},"每月应对消防水泵的出流量和压力进行一次试验","BCD",{"id":299,"libraryId":5,"type":108,"typeLabel":109,"stem":300,"options":301,"answer":312,"analysis":33},935858,"某住宅小区，有18栋20层的住宅，建筑高度为57m，20层楼板标高为54．2m，高位消防水箱底标高为62．6m，室内消防采用联合供水的临时高压消防给水系统，设计流量57L／s，室外埋地供水干管采用DN200mm球墨铸铁管，长2000m，漏水率为1．40L／min ·km，室内管网总的漏水量为0．25L／s。下列关于该系统稳压设施的设置和参数的设计的做法中，符合安全可靠、经济合理要求的有（）。",[302,304,306,308,310],{"key":20,"text":303,"correct":22},"临时高压消防给水系统采用高位消防水箱加稳压泵稳压的方式",{"key":24,"text":305,"correct":29},"高位消防水箱出水管的流量开关启动流量设计值为1．2L／s",{"key":27,"text":307,"correct":22},"高位消防水箱出水管的流量开关启动流量设计值为0．25L／s",{"key":31,"text":309,"correct":22},"高位消防水箱出水管的流量开关启动流量设计值为0．30L／s",{"key":121,"text":311,"correct":29},"临时高压消防给水系统采用高位消防水箱稳压的方式","BE",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},935859,"下列关于水泵接合器做法，正确的是（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":29},"水泵接合器距室外消火栓30m",{"key":24,"text":320,"correct":22},"地下水泵接合器进水口和井盖地面的距离不小于0．4m，且不应小于井盖半径",{"key":27,"text":322,"correct":22},"安装高度距地面为0．9m",{"key":31,"text":324,"correct":22},"组装式水泵接合器按接口、本体、连接管、安全阀、止回阀、放空管、控制阀的顺序进行",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":24,"analysis":33},935860,"在下列给水管网中，可以不设固定支架或防晃支架的部位是（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":22},"公称直径为DN50的管道的中点",{"key":24,"text":332,"correct":29},"长度为15m公称直径为DN40的配水干管",{"key":27,"text":334,"correct":22},"公称直径为DN65的弯头处",{"key":31,"text":336,"correct":22},"公称直径为DN80的三通处",{"id":338,"libraryId":5,"type":108,"typeLabel":109,"stem":339,"options":340,"answer":351,"analysis":33},935861,"下列关于某建筑内消防水泵的调试情况，不符合规范要求的是（ ）。",[341,343,345,347,349],{"key":20,"text":342,"correct":22},"以自动直接启动或手动直接启动消防水泵时，消防水泵在50s内投入正常运行，无不良噪声和振动",{"key":24,"text":344,"correct":22},"以备用电源切换方式切换启动消防水泵时，消防水泵在50s内正常运行",{"key":27,"text":346,"correct":22},"机械应急启动消防水泵时，消防水泵在报警后3．0min内正常工作",{"key":31,"text":348,"correct":29},"消防水泵能自动和手动启停",{"key":121,"text":350,"correct":29},"消防水泵从接到启泵信号到水泵正常运转的自动启动时间为2．5min","DE",{"id":353,"libraryId":5,"type":108,"typeLabel":109,"stem":354,"options":355,"answer":153,"analysis":33},935862,"根据《消防给水及消火栓规范》，下列关于消防给水系统管道试压说法正确的有（ ）。",[356,358,360,362,364],{"key":20,"text":357,"correct":29},"水压试验时环境温度不宜低于 5℃，当低于 5℃时，应采取防冻措施",{"key":24,"text":359,"correct":29},"对于钢管，系统工作压力不大于 1.0MPa 时，水压强度试验压力为系统工作压力的 1.5 倍，且不应小于 1.4MPa",{"key":27,"text":361,"correct":29},"对于钢管，系统工作压力大于 1.0MPa 的，水压强度试验压力为系统工作压力加 0.4MPa",{"key":31,"text":363,"correct":22},"水压强度试验应在水压严密性试验后进行",{"key":121,"text":365,"correct":29},"水压强度试验的测试点应设在系统管网的最低点",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":27,"analysis":33},935863,"消防给水管网冲洗管道直径大于DN（）时，应对其死角和底部进行敲打，但不得损伤管道。",[370,372,374,376],{"key":20,"text":371,"correct":22},"50",{"key":24,"text":373,"correct":22},"75",{"key":27,"text":375,"correct":29},"100",{"key":31,"text":377,"correct":22},"150",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},935864,"在消防给水系统中，在灭火时靠消防车的消防泵来加压，以满足最不利点处消防用水点的水压和流量达到灭火要求的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"高压消防给水系统",{"key":24,"text":385,"correct":22},"临时高压消防给水系统",{"key":27,"text":387,"correct":22},"稳高压消防给水系统",{"key":31,"text":389,"correct":29},"低压消防给水系统",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":27,"analysis":33},935865,"在消防给水系统中，室内消防给水系统是按照（ ）进行分类的。",[394,396,398,400],{"key":20,"text":395,"correct":22},"管网形式",{"key":24,"text":397,"correct":22},"范围",{"key":27,"text":399,"correct":29},"位置",{"key":31,"text":401,"correct":22},"灭火方式",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":27,"analysis":33},935866,"下列关于消防水源的说法中，错误的是（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"消防给水管道内平时所充水的pH值应为6．0～9．0",{"key":24,"text":409,"correct":22},"天然水源可作为消防水源",{"key":27,"text":411,"correct":29},"雨水清水池不应作为备用消防水源",{"key":31,"text":413,"correct":22},"游泳池中的水可作为备用消防水源",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":20,"analysis":33},935867,"下列关于消防水源的维护管理的说法中，正确的是（ ）。",[418,420,422,424],{"key":20,"text":419,"correct":29},"在冬季每天应对消防储水设施进行室内温度和水温检测",{"key":24,"text":421,"correct":22},"每年应监测市政给水管网的压力和供水能力",{"key":27,"text":423,"correct":22},"每季度应对天然河湖等地表水消防水源的常水位、枯水位、洪水位，以及枯水位流量或蓄水量等进行一次检测",{"key":31,"text":425,"correct":22},"消防水池用作消防水源设施时应每周进行一次检测",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},935868,"某公共建筑内设置280个消火栓，对该建筑内的消火栓进行验收，据《消防给水及消火栓系统技术规范》GB 50974—2014的规定，至少应抽查（ ）个消火栓。",[430,432,434,436],{"key":20,"text":431,"correct":22},"10",{"key":24,"text":433,"correct":29},"28",{"key":27,"text":435,"correct":22},"14",{"key":31,"text":437,"correct":22},"56",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},935869,"消防给水管网（钢管）设计工作压力1．2MPa，施工完成后进行试压和冲洗，下列不正确的是（）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"消防给水系统管网水压严密性试验压力为1．2MPa",{"key":24,"text":445,"correct":29},"消防给水系统管网水压强度试验压力为1．4MPa",{"key":27,"text":447,"correct":22},"消防给水系统气压严密性试验压力为0．28MPa",{"key":31,"text":449,"correct":22},"管网冲洗设临时专用排水管道，排水管道的截面面积是冲洗管道截面面积的60％",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},935870,"在某高层写字楼的施工工地，安装室外消防水泵接合器的过程中，下列做法不符合规范要求的是（ ）。",[454,456,458,460],{"key":20,"text":455,"correct":29},"对组装式水泵接合器进行安装时，施工人员应按接口、本体、连接管、安全阀、止回阀、放空管、控制阀的顺序进行",{"key":24,"text":457,"correct":22},"地下水泵接合器井盖的半径为0．3m，进水口与井盖底面的距离为0．4 m",{"key":27,"text":459,"correct":22},"水泵接合器接口的位置应方便操作，安装在便于消防车接近的人行道或非机动车行驶地段，距离消防水池20m",{"key":31,"text":461,"correct":22},"地下水泵接合器井盖应采用铸铁井盖，并铸有“消防水泵接合器”标志",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":20,"analysis":33},935871,"在安装水泵接合器的过程中，错误的做法是（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":29},"墙壁水泵接合器安装在玻璃幕墙下方",{"key":24,"text":469,"correct":22},"组装式水泵接合器的安装，按接口、本体、连接管、止回阀、安全阀、放空管、控制阀的顺序进行",{"key":27,"text":471,"correct":22},"水泵接合器接口的位置安装在距离消防水池30m处",{"key":31,"text":473,"correct":22},"井盖半径为0．3m，在安装地下消防水泵接合器时，进水口与井盖底面的距离为0．4m",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":20,"analysis":33},935872,"根据《消防给水及消火栓系统技术规范》（GB50974—2014），干式消火栓系统允许的最大充水时间是（）min。",[478,480,481,483],{"key":20,"text":479,"correct":29},"5",{"key":24,"text":431,"correct":22},{"key":27,"text":482,"correct":22},"2",{"key":31,"text":484,"correct":22},"3",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":27,"analysis":33},935873,"管径大于DN50的消防管道水平架空安装时，应按规定设置防晃支架。下列位置中，可不设置防晃支架的是（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"管道三通位置处",{"key":24,"text":492,"correct":22},"管道拐弯位置处",{"key":27,"text":494,"correct":29},"管道末端位置处",{"key":31,"text":496,"correct":22},"管道四通位置处",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":27,"analysis":33},935874,"消防设施检测机构的人员对某建筑内消火栓系统进行检测，下列关于管道检查的结果，符合现行国家消防技术标准要求的是（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"DN80的管道采用螺纹活接头连接",{"key":24,"text":504,"correct":22},"配水干管与配水管采用机械三通连接",{"key":27,"text":506,"correct":29},"机械四通开孔间距为2．5m",{"key":31,"text":508,"correct":22},"架空管道上刷红色环圈，红色环圈的宽度为10mm",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":27,"analysis":33},935875,"对建筑内的消防给水系统定期进行维护保养，根据《消防给水及消火栓系统技术规范》GB 50974—2014的规定，下列属于月度检查内容的是（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"消防水泵的出流量和压力试验",{"key":24,"text":516,"correct":22},"柴油机消防水泵的启动电池的电量检查",{"key":27,"text":518,"correct":29},"电动阀和电磁阀的供电和启闭性能检查",{"key":31,"text":520,"correct":22},"稳压泵的启泵次数检查",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":27,"analysis":33},935876,"根据《消防给水及消火栓系统技术规范》（GB50974—2014），下列关于消防水泵的维护管理，说法错误的是（ ）。",[525,527,529,530],{"key":20,"text":526,"correct":22},"每月应手动启动消防水泵运转一次，并检查供电电源的情况",{"key":24,"text":528,"correct":22},"每周应模拟消防水泵自动控制的条件自动启动消防水泵运转一次",{"key":27,"text":296,"correct":29},{"key":31,"text":531,"correct":22},"每周检查柴油机消防水泵储油箱的储油量",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":27,"analysis":33},935877,"维保单位对某高层写字楼内设置的减压水箱进行检查，下列检查结果中符合相关规范要求的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"减压水箱设置了一条进水管",{"key":24,"text":539,"correct":22},"减压水箱设置了一条出水管",{"key":27,"text":541,"correct":29},"减压水箱采用防止旋流器，其出水管喇叭口的保护高度为150mm",{"key":31,"text":543,"correct":22},"减压水箱设置了就地水位显示装置，消防控制中心仅能查看最高和最低报警水位",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":27,"analysis":33},935878,"下列关于消防水泵的施工安装的说法中，错误的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"消防水泵吸水管上的控制阀应在消防水泵固定于基础上后再进行安装，其直径不应小于消防水泵吸水口直径",{"key":24,"text":551,"correct":22},"消防水泵出水管上应安装消声止回阀、控制阀和压力表",{"key":27,"text":553,"correct":29},"吸水管水平管段上不应有气囊和漏气现象，变径连接时，应采用同心异径管件",{"key":31,"text":555,"correct":22},"当消防水泵和消防水池位于独立的两个基础上且相互为刚性连接时，吸水管上应加设柔性连接管",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":24,"analysis":33},935879,"某新建写字楼，建筑高度为48m，每层划分为一个防火分区，消防技术服务机构对该写字楼内自动喷水灭火系统的安装情况进行检查，下列关于末端试水装置的做法中，不正确的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"末端试水装置由试水阀、压力表以及试水接头组成",{"key":24,"text":563,"correct":29},"末端试水装置距地面的高度为1．2m，并采取了不被他用的措施",{"key":27,"text":565,"correct":22},"末端试水装置的出水采取孔口出流的方式排入排水管道",{"key":31,"text":567,"correct":22},"末端试水装置试水接头出水口的流量系数与同楼层内的最小流量系数洒水喷头相等",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":24,"analysis":33},935880,"关于消防水箱的设置，以下说法错误的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"寒冷地区设置的非采暖水箱间，冬季时应保证室温或消防水箱水温不低于5℃",{"key":24,"text":575,"correct":29},"水箱设置在水箱间内时，水箱有管道的侧面与水箱间墙壁的净距不宜小于0．8m",{"key":27,"text":577,"correct":22},"钢板制作的消防水箱的进出水管道宜采用法兰连接，有振动的管道应增设柔性接头",{"key":31,"text":579,"correct":22},"消防水箱的出水管应满足最低有效水位出水不掺气",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":20,"analysis":33},935881,"对自动喷水灭火系统的组件进行调试，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于系统组件调试的要求说法中，不正确的是（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":29},"以手动方式启动消防水泵时，消防水泵应在30s内投入正常运行",{"key":24,"text":587,"correct":22},"以备用泵切换启动消防水泵时，消防水泵应在2min内投入正常运行",{"key":27,"text":589,"correct":22},"稳压泵应能自动启停",{"key":31,"text":591,"correct":22},"以备用电源切换方式启动消防水泵时，消防水泵应在1min内投入正常运行",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":27,"analysis":33},935882,"根据《消防给水及消火栓系统技术规范》GB 50974—2014，下列关于水泵接合器的施工安装要求中，不正确的是（ ）。",[596,598,600,602],{"key":20,"text":597,"correct":22},"墙壁消防水泵接合器的安装应符合设计要求，设计无要求时，其安装高度距地面宜为0．7m",{"key":24,"text":599,"correct":22},"应按接口、本体、连接管、止回阀、安全阀、放空管、控制阀的顺序进行安装",{"key":27,"text":601,"correct":29},"地下消防水泵接合器的安装，应使进水口与井盖底面的距离不大于0．4m，且不应小于井盖的直径",{"key":31,"text":603,"correct":22},"地下消防水泵接合器井的砌筑应有防水和排水措施",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":24,"analysis":33},935883,"某民用建筑采用临时高压消防给水系统，并设置有稳压泵，消防机构对稳压泵进行验收，下列关于稳压泵的验收要求，不正确的是（ ）。",[608,610,612,614],{"key":20,"text":609,"correct":22},"稳压泵在1h内的启停次数应符合设计要求，并不宜大于15次／h",{"key":24,"text":611,"correct":29},"应在消防联动控制器的手动控制盘上设置直接手动控制稳压泵启动、停止的按钮，并采用专线连接",{"key":27,"text":613,"correct":22},"气压水罐的有效储水容积不宜小于150L",{"key":31,"text":615,"correct":22},"关掉主电源，主、备电源应能正常切换",{"id":617,"libraryId":5,"type":15,"typeLabel":16,"stem":618,"options":619,"answer":31,"analysis":33},935884,"某办公楼建筑采用临时高压消防给水系统,屋顶设有高位消防水箱和增压稳压设施。下列关于系统维护管理,不正确的是（ ）。",[620,621,623,625],{"key":20,"text":292,"correct":22},{"key":24,"text":622,"correct":22},"每月对气压水罐的压力和有效容积等进行一次检测",{"key":27,"text":624,"correct":22},"每季度对消防水泵的出流量和压力进行一次试验",{"key":31,"text":626,"correct":29},"每季度对电动阀和电磁阀的供电和启闭性能进行检测",{"id":628,"libraryId":5,"type":15,"typeLabel":16,"stem":629,"options":630,"answer":20,"analysis":33},935885,"下列有关水泵机组的安装要求的说法中,正确的是（ ）。",[631,633,635,637],{"key":20,"text":632,"correct":29},"水泵机组基础的平面尺寸,无隔振安装应比水泵机组底座四周各宽出 100~150mm",{"key":24,"text":634,"correct":22},"水泵机组基础的顶面标高,无隔振安装时应高出泵房地面不小于 0.05m",{"key":27,"text":636,"correct":22},"当管径 DN≤150m 时,泵房内管道管外底距地面的距离不应小于 0.25m",{"key":31,"text":638,"correct":22},"水泵吸水管水平段同心大小头应采用管顶平接",{"id":640,"libraryId":5,"type":15,"typeLabel":16,"stem":641,"options":642,"answer":27,"analysis":33},935886,"消防水池和消防水箱出水管或水泵吸水管要满足（ ）的技术要求。",[643,645,647,649],{"key":20,"text":644,"correct":22},"最低有效水位出水掺气",{"key":24,"text":646,"correct":22},"最高有效水位出水掺气",{"key":27,"text":648,"correct":29},"最低有效水位出水不掺气",{"key":31,"text":650,"correct":22},"最高有效水位出水不掺气",[652,655,658,661,664,667],{"id":15,"name":653,"category":7,"favorite":654},"领导干部任职前廉政法规知识测试题",92,{"id":656,"name":657,"category":7,"favorite":15},595,"建筑结构与设备",{"id":659,"name":660,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":662,"name":663,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":665,"name":666,"category":7,"favorite":8},534,"BIM工程师",{"id":668,"name":666,"category":7,"favorite":8},535]