[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":639},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,23,50,2974,[13,34,46,58,70,82,97,109,121,136,148,160,172,184,196,208,220,232,247,262,277,289,301,313,325,337,349,361,373,385,397,409,421,433,445,457,469,481,496,508,520,532,544,556,568,580,592,603,615,627],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},935784,1,"单选题","某宾馆消防控制室先后接到不同防火分区的2个感烟探测器传来动作信号，灭火系统尚未启动，下列值班人员的工作程序中，正确的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","立即拨打119报警",false,{"key":24,"text":25,"correct":22},"B","立即启动单位应急疏散预案",{"key":27,"text":28,"correct":22},"C","立即报告消防安全责任人",{"key":30,"text":31,"correct":32},"D","以最快方式确认火灾",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},935785,"对防烟排烟系统进行验收的过程中，竣工验收判定结论为合格的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"A=0，B=3，B+C=4",{"key":24,"text":41,"correct":22},"A=0，B=2，B+C=8",{"key":27,"text":43,"correct":32},"A=0，B=2，B+C=5",{"key":30,"text":45,"correct":22},"A=1，B=2，B+C=3",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},935786,"各类消防设施的设备、组件及材料等消防产品到达施工现场后，施工单位应当组织实施现场检查，其中检查消防产品的型号规格是否与设计文件相符属于（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"合法性检查",{"key":24,"text":53,"correct":32},"一致性检查",{"key":27,"text":55,"correct":22},"产品质量检查",{"key":30,"text":57,"correct":22},"产品合规检查",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},935787,"泡沫灭火系统按照《泡沫灭火系统施工及验收规范》（GB502831-2006）的规定内容进行竣工验收,当其（ ）验收不合格时,系统验收判定为不合格（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":32},"功能",{"key":24,"text":65,"correct":22},"组件",{"key":27,"text":67,"correct":22},"管件",{"key":30,"text":69,"correct":22},"灭火剂",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},935788,"消防给水及消火栓系统、自动喷水灭火系统、防烟排烟系统和火灾自动报警系统等工程施工质量缺陷划分为严重缺陷项 （A）、重缺陷项 （B）和轻缺陷项 （C），当（ ）时，消防给水及消火栓系统的工程竣工验收判定为合格。",[74,76,78,80],{"key":20,"text":75,"correct":22},"A=1，且B≤1，且B+C≤5",{"key":24,"text":77,"correct":22},"A=1，且B≤1，且B+C≤6",{"key":27,"text":79,"correct":32},"A=0，且B≤2，且B+C≤6",{"key":30,"text":81,"correct":22},"A=0，且B≤2，且B+C≤5%",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":96,"analysis":33},935789,2,"多选题","施工单位采购的各类消防设施的设备、组件以及材料等到达施工现场后，施工单位组织实施现场检查，消防设施现场检查包括（ ）。",[88,89,91,93,94],{"key":20,"text":51,"correct":32},{"key":24,"text":90,"correct":22},"施工详图检查",{"key":27,"text":92,"correct":22},"组件安装检查说明书",{"key":30,"text":53,"correct":32},{"key":95,"text":55,"correct":32},"E","ADE",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":30,"analysis":33},935790,"关于消防设施现场检查中的合法性检查，下列描述正确的是（）。",[101,103,105,107],{"key":20,"text":102,"correct":22},"纳入强制性产品认证的消防产品，查验其依法获得的技术鉴定证书",{"key":24,"text":104,"correct":22},"新研制的尚未制定国家或者行业标准的消防产品，不需要进行查验",{"key":27,"text":106,"correct":22},"查验个别消防产品的型式检验报告",{"key":30,"text":108,"correct":32},"查验所有消防产品、管材管件以及其他设备的出厂检验报告或者出厂合格证",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":30,"analysis":33},935791,"根据《自动喷水灭火系统施工及验收规范》（GB50261—2017）的规定，自动喷水灭火系统的验收缺陷项分为严重缺陷项、重缺陷项和轻缺陷项，下列检查结果属于重缺陷项的是（ ）。",[113,115,117,119],{"key":20,"text":114,"correct":22},"消防水箱的容量不符合设计要求",{"key":24,"text":116,"correct":22},"喷头设置场所、规格、型号、公称动作温度、响应时间指数（RTI）不符合设计要求。",{"key":27,"text":118,"correct":22},"通过系统流量压力检测装置进行放水试验，系统流量、压力不符合设计要求",{"key":30,"text":120,"correct":32},"管网不同部位安装的报警阀组不符合设计要求",{"id":122,"libraryId":5,"type":84,"typeLabel":85,"stem":123,"options":124,"answer":135,"analysis":33},935792,"为了确保施工质量，施工中要建立健全施工质量管理体系和工程质量检验制度，施工现场配备必要的施工技术标准。消防设施施工过程质量应该按照下列哪些要求组织实施（）。",[125,127,129,131,133],{"key":20,"text":126,"correct":32},"对到场的各类消防设施的设备、组件以及材料进行现场检查，经检查合格后方可用于施工",{"key":24,"text":128,"correct":22},"各工序按照施工技术标准进行质量控制，每道工序完成后进行检查，检查后即可进入下一道工序",{"key":27,"text":130,"correct":32},"相关各专业工种之间交接时，进行检验认可，经监理工程师签证后，方可进行下一道工序",{"key":30,"text":132,"correct":32},"消防设施安装完毕，施工单位按照相关专业调试规定进行调试",{"key":95,"text":134,"correct":32},"调试结束后，施工单位向建设单位提供质量控制资料和各类消防设施施工过程质量检查记录","ACDE",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},935793,"下列属于灭火器严重缺陷项级别 （ ）的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":32},"同一配置单元内存在ABBC两种类型的灭火器",{"key":24,"text":143,"correct":22},"灭火器设置点附近有障碍物",{"key":27,"text":145,"correct":22},"翻盖型灭火器箱的翻盖开启角度为90&deg;",{"key":30,"text":147,"correct":22},"开门型灭火器箱箱门的开启角度为150&deg;",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":27,"analysis":33},935794,"消防控制室内的图形显示装置、火灾报警控制器、消防联动控制设备，其功能既相互独立，又互相关联，准确把控其功能是充分发挥消防控制室监控与管理作用的关键。下列消防控制室图形显示装置，不符合国家工程技术标准的是（）。",[152,154,156,158],{"key":20,"text":153,"correct":22},"采用中文标注和中文界面的消防控制室图形显示装置",{"key":24,"text":155,"correct":22},"其界面对角线长度不得小于430mm",{"key":27,"text":157,"correct":32},"100s内能够显示输入的火灾报警信号和反馈信号的状态信息",{"key":30,"text":159,"correct":22},"100s内能够显示其他输入信号的状态信息",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":30,"analysis":33},935795,"按照国家相关法律法规规定，在产品市场准入文件检查中，对目前尚未纳入强制性产品认证的非新产品类的消防产品，查验其经国家法定消防产品检验机构检验合格的（ ）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"技术鉴定证书",{"key":24,"text":167,"correct":22},"强制认证证书",{"key":27,"text":169,"correct":22},"法定质量保证文件",{"key":30,"text":171,"correct":32},"型式检验报告",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},935796,"下列关于消防设施的设备及其组件、材料等产品质量检查的做法中，错误的是（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"自动喷水灭火系统重点对其设备、组件以及管件、管材的外观（尺寸）、组件结构及其操作性能进行检查",{"key":24,"text":179,"correct":32},"火灾应急照明以及疏散指示系统重点对其设备及其组件进行性能检查",{"key":27,"text":181,"correct":22},"干粉灭火系统除重点对其设备、组件以及管件、管材的外观（尺寸）、组件结构及其操作性能进行检查外，还要对灭火剂储存容器的充装量、充装压力等进行检查",{"key":30,"text":183,"correct":22},"防烟排烟设施重点检查风机、风管及其部件的外观（尺寸）、材料燃烧性能和操作性能",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":30,"analysis":33},935797,"巡查是指建筑使用管理单位对建筑消防设施直观属性的检查，下列关于巡查频次的说法中，错误的是（ ）。",[188,190,192,194],{"key":20,"text":189,"correct":22},"消防安全重点单位每日至少对消防设施巡查1次",{"key":24,"text":191,"correct":22},"公共娱乐场所营业期间，每2h组织1次综合巡查",{"key":27,"text":193,"correct":22},"其他社会单位每周至少对消防设施巡查1次",{"key":30,"text":195,"correct":32},"举办具有火灾危险性的大型群众性活动的，承办单位每2h组织1次综合巡查",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":30,"analysis":33},935799,"《建筑消防设施检测记录表》《建筑消防设施故障维修记录表》《建筑消防设施维护保养计划表》《建筑消防设施维护保养记录表》的存档时间不少于（ ）年。",[200,202,204,206],{"key":20,"text":201,"correct":22},"二",{"key":24,"text":203,"correct":22},"三",{"key":27,"text":205,"correct":22},"四",{"key":30,"text":207,"correct":32},"五",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},935800,"某建筑消防给水系统使用2台型号一致的消防水泵组成泵组（一用一备），单台设计流量35L\u002Fs，设计工作压力为0.90MPa。该泵组设置的压力检测装置的最大量程至少应大于（ ）MPa。",[212,214,216,218],{"key":20,"text":213,"correct":22},"1.80",{"key":24,"text":215,"correct":32},"1.98",{"key":27,"text":217,"correct":22},"2.25",{"key":30,"text":219,"correct":22},"2.70",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":33},935802,"2012 年建成的某大型综合楼,至今己经有很多关于消防方面的记录表。下列关于该大型综合楼的存档资料中,存档时间不应少于 1 年的有（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":32},"《建筑消防设施巡查记录表》",{"key":24,"text":227,"correct":22},"《建筑消防设施维护保养记录表》",{"key":27,"text":229,"correct":22},"《建筑消防设施故障维修记录表》",{"key":30,"text":231,"correct":22},"《建筑消防设施检测记录表》",{"id":233,"libraryId":5,"type":84,"typeLabel":85,"stem":234,"options":235,"answer":246,"analysis":33},935803,"消防设施施工前，需要将经批准的消防设计文件以及其他技术资料准备齐全，其中其他技术资料包括（ ）。",[236,238,240,242,244],{"key":20,"text":237,"correct":32},"消防设施产品明细表",{"key":24,"text":239,"correct":32},"主要组件安装使用说明书及施工技术要求",{"key":27,"text":241,"correct":22},"消防设施设计施工图",{"key":30,"text":243,"correct":32},"工程质量管理资料",{"key":95,"text":245,"correct":32},"产品出厂合格证书","ABDE",{"id":248,"libraryId":5,"type":84,"typeLabel":85,"stem":249,"options":250,"answer":261,"analysis":33},935804,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于报警阀组的安装要求中，不正确的是（ ）。",[251,253,255,257,259],{"key":20,"text":252,"correct":32},"安装时应先安装报警阀，然后安装水源控制阀并进行报警阀辅助管道的连接",{"key":24,"text":254,"correct":22},"报警阀组的安装应在供水管网试压、冲洗合格后进行",{"key":27,"text":256,"correct":22},"距室内地面高度宜为1．2m",{"key":30,"text":258,"correct":22},"两侧与墙的距离不应小于0．5m",{"key":95,"text":260,"correct":32},"正面与墙的距离不应小于1．5m","AE",{"id":263,"libraryId":5,"type":84,"typeLabel":85,"stem":264,"options":265,"answer":276,"analysis":33},935805,"下列关于消防设施维护管理人员从业资格要求的叙述中，正确的有（ ）。",[266,268,270,272,274],{"key":20,"text":267,"correct":22},"消防设施维修人员，必须经消防行业特有工种职业技能鉴定合格，持有高级技能以上等级职业资格证书",{"key":24,"text":269,"correct":32},"消防设施检测、维护保养等消防技术服务机构的项目经理、技术人员，必须经注册消防工程师考试合格，持有一级或者二级注册消防工程师的执业资格证书",{"key":27,"text":271,"correct":32},"消防设施操作、值班、巡查的人员，经消防行业特有工种职业技能鉴定合格，持有初级技能（含）以上等级的职业资格证书，能够熟练操作消防设施",{"key":30,"text":273,"correct":32},"消防设施维修人员，必须经消防行业特有工种职业技能鉴定合格，持有技师以上等级职业资格证书",{"key":95,"text":275,"correct":32},"消防设施检测、保养人员，必须经消防行业特有工种职业技能鉴定合格，持有高级技能以上等级职业资格证书","BCDE",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":30,"analysis":33},935806,"对某建筑设置的消防水池进行检查，下列检查结果中可以判定不符合相关规定的是（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"消防水池进水管管径为DN125",{"key":24,"text":284,"correct":22},"消防水池的取水口与水泵房之间的距离为10m",{"key":27,"text":286,"correct":22},"消防水池设置有溢流水管和排水设施，并采用间接排水",{"key":30,"text":288,"correct":32},"供消防车取水的消防水池取水口高度为8．0m",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":30,"analysis":33},935807,"某消防检测机构对消防水泵进行验收时，验收结果如下，其中不符合规范要求的是（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"吸水管、出水管上的控制阀锁定在常开位置，且有明显标记",{"key":24,"text":296,"correct":22},"打开消防水泵出水管上试水阀，当采用主电源启动消防水泵时，消防水泵启动正常",{"key":27,"text":298,"correct":22},"消防水泵启动控制置于自动启动挡",{"key":30,"text":300,"correct":32},"消防水泵停泵时，水锤消除设施后的压力超过水泵出口设计压力的1．4倍",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":20,"analysis":33},935808,"下列有关消防水泵接合器安装的说法中，错误的是（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":32},"墙壁水泵接合器安装高度距地面宜为1．1m",{"key":24,"text":308,"correct":22},"组装式消防水泵接合器的安装，应按接口、本体、连接管、止回阀、安全阀、放空管、控制阀的顺序进行",{"key":27,"text":310,"correct":22},"止回阀的安装方向应使消防用水能从消防水泵接合器进入系统",{"key":30,"text":312,"correct":22},"消防水泵接合器接口与室外消火栓或消防水池的距离宜为15～40m",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},935809,"下列关于稳压泵的设计、安装及调试要求的说法中，不符合现行国家消防技术标准的是（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":32},"稳压泵不需要设置备用工作泵",{"key":24,"text":320,"correct":22},"当稳压泵达到设计启动或停止的压力时，稳压泵应能自动启动或自动停止",{"key":27,"text":322,"correct":22},"稳压泵在正常工作时每小时的启停次数不应大于15次\u002Fh",{"key":30,"text":324,"correct":22},"应能满足系统自动启动要求，且当消防主泵启动时，稳压泵应停止运行",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":27,"analysis":33},935810,"对地下2层，每层建筑面积为2000m2的商场设置的消防水泵接合器进行检查，下列检查结果不符合相关规定的是（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":22},"消防水泵接合器接口距离室外消火栓的距离为25m",{"key":24,"text":332,"correct":22},"消防水泵接合器安装的位置便于消防车接近使用",{"key":27,"text":334,"correct":32},"消火栓水泵接合器与消防通道之间设有用于展示商场商品信息的大型电子广告牌",{"key":30,"text":336,"correct":22},"水泵接合器处设有永久性标志铭牌，并标有相应的信息",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":24,"analysis":33},935811,"在消防给水系统中，灭火时启动消防泵，使管网中最不利处消防用水点的水压和流量达到灭火要求的是（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":22},"低压消防给水系统",{"key":24,"text":344,"correct":32},"临时高压消防给水系统",{"key":27,"text":346,"correct":22},"稳高压消防给水系统",{"key":30,"text":348,"correct":22},"高压消防给水系统",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":33},935813,"对某地上3层的KTV进行消防检查，有关湿式自动喷水灭火系统喷头安装的检查结果如下，其中不符合规范要求的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":32},"喷头与管道支、吊架之间的最小距离为150mm",{"key":24,"text":356,"correct":22},"为追求美观效果，KTV内部分位置安装隐蔽式洒水喷头",{"key":27,"text":358,"correct":22},"末端洒水喷头与管道支、吊架之间的最大距离为500mm",{"key":30,"text":360,"correct":22},"KTV内采用快速响应洒水喷头",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":33},935814,"用作两路消防供水的市政给水管应符合的条件表述错误的是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":32},"应至少有两个市政给水厂上的两条输水干管向市政给水管网输水",{"key":24,"text":368,"correct":22},"市政给水管网应为环状管网",{"key":27,"text":370,"correct":22},"应至少有两条不同的市政给水干管上不少于两条引入管向消防给水系统供水",{"key":30,"text":372,"correct":22},"市政给水管网可以连续供水",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},935815,"关于消防给水管道的安装，以下说法错误的是（ ）",[377,379,381,383],{"key":20,"text":378,"correct":22},"管径小于DN50时配水管中点可不设防晃支架",{"key":24,"text":380,"correct":32},"管道变径当采用补芯时，三通上可用二个，四通上不应超过三个",{"key":27,"text":382,"correct":22},"消防给水管穿过楼板时应加套管，套管应高出地面50mm",{"key":30,"text":384,"correct":22},"公称直径大于50mm的管道不宜使用活接头",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":30,"analysis":33},935816,"分区供水形式应根据系统压力、建筑特征，经技术经济和安全可靠性等综合因素确定，某消火栓系统当系统工作压力大于2．4MPa时，应采用（ ）形式。",[389,391,393,395],{"key":20,"text":390,"correct":22},"消防水泵并行",{"key":24,"text":392,"correct":22},"减压稳压消火栓",{"key":27,"text":394,"correct":22},"减压阀减压",{"key":30,"text":396,"correct":32},"消防水泵直接串联",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":27,"analysis":33},935817,"下列关于消防水泵的流量和压力测试装置的设置中，不正确的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"单台消防水泵的流量不大于20L／s、设计工作压力不大于0．50MPa时，泵组应预留测量用流量计和压力计接口",{"key":24,"text":404,"correct":22},"消防水泵流量检测装置的计量精度应为0．4级，最大量程的75％应大于最大一台消防水泵设计流量值的175％",{"key":27,"text":406,"correct":32},"每台消防水泵吸水管上应设置DN65的试水管，并应采取排水措施",{"key":30,"text":408,"correct":22},"消防水泵压力检测装置的计量精度应为0．5级，最大量程的75％应大于最大一台消防水泵设计压力值的165％",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":20,"analysis":33},935818,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于自动喷水灭火系统试验前应具备的条件，不正确的是（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":32},"试压用的压力表不应少于2只，精度不应低于1．5级，量程应为试验压力值的2．0倍～2．5倍",{"key":24,"text":416,"correct":22},"试压冲洗方案已经批准",{"key":27,"text":418,"correct":22},"埋地管道的位置及管道基础、支墩等经复查应符合设计要求",{"key":30,"text":420,"correct":22},"对不能参与试压的设备、仪表、阀门及附件应加以隔离或拆除",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},935819,"下列关于消防给水管道的设置要求中，不正确的是（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":32},"消防水泵出水管压力表的最大量程应为系统工作压力的1．6～2倍",{"key":24,"text":428,"correct":22},"消防水泵吸水管宜设置真空表、压力表或真空压力表",{"key":27,"text":430,"correct":22},"消防水泵吸水管上的压力表的最大量程应根据工程具体情况确定，但不应低于0．70MPa",{"key":30,"text":432,"correct":22},"消防水泵出水管压力表的直径不应小于100mm，应采用直径不小于6mm的管道与消防水泵进出口管相接，并应设置关断阀门",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":30,"analysis":33},935820,"下列关于架空管道支吊架的施工安装要求中，正确的是（ ）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"管径大于DN40的管道拐弯、三通及四通位置处应设1个防晃支架",{"key":24,"text":440,"correct":22},"配水干管及配水管，配水支管的长度超过15m，每15m长度内应至少设1个防晃支架，但当管径不大于DN50可不设",{"key":27,"text":442,"correct":22},"配水管宜在中点设一个防晃支架，但当管径不大于DN50时可不设",{"key":30,"text":444,"correct":32},"当管道穿梁安装时，管道再用紧固件固定于混凝土结构上，宜可作为1个防晃支架",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":33},935821,"消防水池的施工安装，要注意消防水池的外壁与建筑本体结构墙面或其他池壁之间的净距。无管道的侧面，净距不宜小于 0.7 m；有管道的侧面，净距不宜小于（ ） m，且管道外壁与建筑本体墙面之间的通道宽度不宜小于（ ） m。",[449,451,453,455],{"key":20,"text":450,"correct":22},"0.9， 0.6",{"key":24,"text":452,"correct":32},"1.0， 0.6",{"key":27,"text":454,"correct":22},"0.9， 0.5",{"key":30,"text":456,"correct":22},"1.0， 0.5",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},935822,"某炼铁厂高炉车间为保证在消防泵岀现故障的紧急情况下应急供水,设有高位消防水箱。由于受紫外线照射时强度有变化,选择消防水箱时不推荐使用（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"碳素钢板水箱",{"key":24,"text":464,"correct":32},"玻璃钢水箱",{"key":27,"text":466,"correct":22},"不锈钢水箱",{"key":30,"text":468,"correct":22},"钢筋混凝土水箱",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},935823,"在寒冷的场所，消防水箱应采取保温措施或在水箱间设置采暖使室内温度大于（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":32},"5℃",{"key":24,"text":476,"correct":22},"10℃",{"key":27,"text":478,"correct":22},"15℃",{"key":30,"text":480,"correct":22},"20℃",{"id":482,"libraryId":5,"type":84,"typeLabel":85,"stem":483,"options":484,"answer":495,"analysis":33},935824,"维保单位对某综合楼内消防给水系统设置的消防水泵进行检查，下列做法和检查结果中符合规范要求的是（ ）。",[485,487,489,491,493],{"key":20,"text":486,"correct":32},"自动喷水灭火系统的消防水泵配用电机功率为132kW，采用工频启动消防水泵，从接通电路到水泵达到额定转速的时间为28s",{"key":24,"text":488,"correct":32},"消火栓系统的消防水泵从接到启泵信号到水泵正常运转的自动启动时间为90s",{"key":27,"text":490,"correct":32},"消防水泵控制柜均设置机械应急启泵功能，采用机械应急方式启动时，消防水泵在报警后3min内正常工作",{"key":30,"text":492,"correct":22},"检查人员采用电动驱动消防水泵自动巡检时，以低频交流电源逐台驱动消防水泵，使每台消防水泵低速转动的时间为1min",{"key":95,"text":494,"correct":32},"消火栓系统的消防水泵配用电机功率为150KW，采用工频启动消防水泵，从接通电路到水泵达到额定转速的时间为32s","ABCE",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":27,"analysis":33},935825,"下列有关市政给水管网作为两路消防供水条件的说法，不正确的是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"有不同市政给水干管上不少于两条引入管向消防给水系统供水",{"key":24,"text":503,"correct":22},"市政给水管网布置成环状管网",{"key":27,"text":505,"correct":32},"市政给水厂至少有一条输水干管向市政给水管网输水",{"key":30,"text":507,"correct":22},"市政给水管网应连续供水",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":24,"analysis":33},935826,"下列有关消防水泵安装的说法，错误的是（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":22},"当消防水泵和消防水池位于独立的两个基础上且相互为刚性连接时，吸水管上应加设柔性连接管",{"key":24,"text":515,"correct":32},"消防水泵吸水管变径时应采用偏心异径管件并应采用管底平接",{"key":27,"text":517,"correct":22},"消防水泵的规格、型号等应与设计要求一致，并应根据说明书的要求进行安装",{"key":30,"text":519,"correct":22},"消防水泵出水管上应安装消声止回阀、控制阀和压力表",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":24,"analysis":33},935827,"安装单位技术人员对某商场稳压泵进行调试，调试结果如下，其中不符合现行国家消防技术标准的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"当稳压泵达到设计启动压力时，稳压泵启动",{"key":24,"text":527,"correct":32},"当系统消防主泵启动时，稳压泵继续运行",{"key":27,"text":529,"correct":22},"启停次数为10次／h",{"key":30,"text":531,"correct":22},"稳压泵启动和停止时系统压力平稳",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":24,"analysis":33},935828,"下列有关减压阀调试的说法中，错误的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"减压阀达到设计流量的150％时不应出现噪声明显增加",{"key":24,"text":539,"correct":32},"减压阀的出流量为设计流量的150％时，阀后动压应小于额定设计工作压力的65％",{"key":27,"text":541,"correct":22},"测试减压阀的阀后动静压差应符合设计要求",{"key":30,"text":543,"correct":22},"减压阀的阀前阀后动静压力应满足设计要求",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":20,"analysis":33},935829,"下列有关高位消防水箱的施工、安装说法中，错误的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":32},"安装有管道的侧面，消防水箱的外壁与建筑本体结构墙面净距不宜小于0．9m",{"key":24,"text":551,"correct":22},"设有人孔的池顶，顶板面与上面建筑本体板底的净空不应小于0．8m",{"key":27,"text":553,"correct":22},"无管道的侧面，消防水箱的外壁与建筑本体结构墙面净距不宜小于0．7m",{"key":30,"text":555,"correct":22},"安装有管道的侧面，管道外壁与建筑本体墙面之间的通道宽度不宜小于0．6m",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":24,"analysis":33},935830,"下列有关消防给水系统试压冲洗的说法中，错误的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"管网冲洗应在试压合格后分段进行",{"key":24,"text":563,"correct":32},"室内部分的冲洗应按立管、水平管和供水干管的顺序进行",{"key":27,"text":565,"correct":22},"冲洗顺序应先室外，后室内先地下，后地上",{"key":30,"text":567,"correct":22},"强度试验和严密性试验宜用水进行",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":30,"analysis":33},935831,"下列有关消防供水设施、设备安装要求的说法中，不正确的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"消防水泵在安装前应复核消防水泵之间，以及消防水泵与墙或其他设备之间的间距",{"key":24,"text":575,"correct":22},"地下式消防水泵接合器的安装，应使进水口与井盖地面的距离不大于0．4m，且不应小于井盖的半径",{"key":27,"text":577,"correct":22},"气压水罐宜有有效水容积指示器",{"key":30,"text":579,"correct":32},"稳压泵的吸水管上应设置暗杆闸阀",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":24,"analysis":33},935832,"根据现行国家标准《消防给水及消火栓系统技术规范》GB 50974—2014的规定，应每（ ）对系统所有的末端试水阀和报警阀的放水试验阀进行一次放水试验，并应检查系统启动、报警功能以及出水情况是否正常。",[584,586,588,590],{"key":20,"text":585,"correct":22},"月",{"key":24,"text":587,"correct":32},"季度",{"key":27,"text":589,"correct":22},"半年",{"key":30,"text":591,"correct":22},"年",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":30,"analysis":33},935833,"关于消防水泵安装时应符合的要求，下列说法不正确的是（ ）。",[596,598,599,601],{"key":20,"text":597,"correct":22},"消防水泵吸水管上的控制阀应在消防水泵固定于基础上后再进行安装",{"key":24,"text":513,"correct":22},{"key":27,"text":600,"correct":22},"消防水泵不宜设置在有防振要求房间的下一层，当必须设置时应采取降噪减振措施",{"key":30,"text":602,"correct":32},"消防水泵的吸水管水平管段上采用变径连接时，应采用同心异径管件并采用管顶平接",{"id":604,"libraryId":5,"type":15,"typeLabel":16,"stem":605,"options":606,"answer":30,"analysis":33},935834,"在地震烈度在7度及7度以上安装架空管道时，对供水主管，竖向支撑的间距不应大于（ ）m。",[607,609,611,613],{"key":20,"text":608,"correct":22},"10",{"key":24,"text":610,"correct":22},"14",{"key":27,"text":612,"correct":22},"20",{"key":30,"text":614,"correct":32},"24",{"id":616,"libraryId":5,"type":15,"typeLabel":16,"stem":617,"options":618,"answer":24,"analysis":33},935835,"根据《消防给水及消火栓系统技术规范》GB 50974—2014的规定，消防给水管网试压前准备试压用的压力表不应少于（ ）只，精度不应低于（ ）级。",[619,621,623,625],{"key":20,"text":620,"correct":22},"1．1．2",{"key":24,"text":622,"correct":32},"2．1．5",{"key":27,"text":624,"correct":22},"1．1．5",{"key":30,"text":626,"correct":22},"2，2",{"id":628,"libraryId":5,"type":15,"typeLabel":16,"stem":629,"options":630,"answer":30,"analysis":33},935836,"对消防给水系统管网进行气压严密性试验，下列关于试验压力和保压时间的说法，正确的是（ ）。",[631,633,635,637],{"key":20,"text":632,"correct":22},"试验压力为3．0MPa，保压时间为3min",{"key":24,"text":634,"correct":22},"试验压力为0．05MPa，保压时间为30min",{"key":27,"text":636,"correct":22},"试验压力为1．0MPa，保压时间为24h",{"key":30,"text":638,"correct":32},"试验压力为0．28MPa，保压时间为24h",[640,643,646,649,652,655],{"id":15,"name":641,"category":7,"favorite":642},"领导干部任职前廉政法规知识测试题",92,{"id":644,"name":645,"category":7,"favorite":15},595,"建筑结构与设备",{"id":647,"name":648,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":650,"name":651,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":653,"name":654,"category":7,"favorite":8},534,"BIM工程师",{"id":656,"name":654,"category":7,"favorite":8},535]