[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-22":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":661},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,22,50,2974,[13,34,46,58,70,82,94,106,124,139,154,169,184,198,210,222,234,246,258,269,281,293,308,323,338,350,358,370,382,394,406,418,430,440,455,470,484,499,511,523,535,547,559,571,583,592,606,620,634,649],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},935733,1,"单选题","在对建筑外墙保温系统进行防火检查时，下列做法不符合现行国家消防技术标准要求的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","建筑高度为24m的办公楼，基层墙体与装饰层之间有空腔，外墙外保温系统采用燃烧性能为B1级的保温材料",false,{"key":24,"text":25,"correct":22},"B","建筑高度为54m的住宅楼，基层墙体与装饰层之间无空腔，外墙外保温系统采用燃烧性能为B1级的保温材料",{"key":27,"text":28,"correct":29},"C","建筑高度为15m的学生宿舍楼，基层与墙体装饰层之间无空腔，外墙外保温系统采用燃烧性能为B1级的保温材料",true,{"key":31,"text":32,"correct":22},"D","建筑高度为15m的办公楼，基层墙体与装饰层之间无空腔，外墙外保温系统采用燃烧性能为B1级的保温材料","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},935734,"在对中庭装修进行检查时，其连通部位地面的装修材料燃烧性能等级不应低于（ ）级，顶棚装修材料燃烧性能等级不应低于（ ）级",[38,40,42,44],{"key":20,"text":39,"correct":22},"B1",{"key":24,"text":41,"correct":22},"B1，B1",{"key":27,"text":43,"correct":29},"B1，A",{"key":31,"text":45,"correct":22},"B1，B2",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},935735,"下列关于建筑外墙外保温系统与建筑屋面外保温系统的说法，不正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":29},"建筑外墙外保温系统与基层墙体、装饰层之间的空腔，应每隔一层楼板采用防火封堵材料封堵",{"key":24,"text":53,"correct":22},"建筑的屋面外保温系统，当屋面板的耐火极限不低于1．00h时，保温材料的燃烧性能不应低于B2级",{"key":27,"text":55,"correct":22},"建筑的屋面外保温系统，当屋面板的耐火极限低于1．00h时，不应低于B1级",{"key":31,"text":57,"correct":22},"采用B1、B2级保温材料的屋面外保温系统应采用不燃材料作防护层，防护层的厚度不应小于10mm",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},935736,"下列装修材料中，属于A级装修材料的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"铝箔复合材料",{"key":24,"text":65,"correct":22},"玻璃棉板",{"key":27,"text":67,"correct":29},"硅酸钙板",{"key":31,"text":69,"correct":22},"难燃玻璃钢",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},935737,"某民用建筑，首层为商业服务网点，二到九层为住宅，住宅平屋面面层标高为27．2m，室外设计地面标高为-0．500m，首层地面标高为0．200m，外墙外保温材料的燃烧性能等级为B1级，下列做法，正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"建筑的外墙外保温系统采用不燃材料在其表面设置防护层，防护层首层厚度为10mm",{"key":24,"text":77,"correct":22},"建筑的外墙外保温系统采用不燃材料在其表面设置防护层，建筑二层及以上防护层的厚度为3mm",{"key":27,"text":79,"correct":22},"每层设置水平防火隔离带，防护隔离带高度为200rnm",{"key":31,"text":81,"correct":29},"外墙上的门、窗耐火完整性为0．25h",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},935738,"对设备用房进行防火检查，应注意设备用房的内部装修材料燃烧性能等级，下列设备用房中，内部装修材料的燃烧性能等级与其他选项不同的（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"消防水泵房",{"key":24,"text":89,"correct":29},"消防控制室",{"key":27,"text":91,"correct":22},"变压器室",{"key":31,"text":93,"correct":22},"机械加压送风机房",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},935739,"对某多层医院综合楼进行防火检查，查阅资料得知，该医院综合楼耐火等级为一级，首层为诊疗区，二层到三层为手术区，四层及以上为住院区，建筑内部设置了自动喷水灭火系统和火灾自动报警系统。下列关于该大楼装修材料的检查结果如下，其中不符合规范要求的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"该医院诊疗区墙面装修材料采用防火塑料装饰板",{"key":24,"text":101,"correct":22},"该医院手术区地面装修材料采用PVC卷材地板",{"key":27,"text":103,"correct":29},"该医院疏散走道顶板装修材料采用矿棉板",{"key":31,"text":105,"correct":22},"该医院病房内顶板装修材料采用难燃胶合板",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},935740,2,"多选题","下列特殊部位室内装修的说法中，正确的是（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":22},"疏散楼梯间的顶棚、墙面应采用A级装修材料，其余部位应不低于B1级装修材料",{"key":24,"text":115,"correct":29},"中庭顶棚、墙面应采用A级装修材料，其余部位应不低于B1级装修材料",{"key":27,"text":117,"correct":22},"公共厨房顶棚、墙面应采用A级装修材料，其余部位应不低于B1级装修材料",{"key":31,"text":119,"correct":22},"避难走道、防火隔间顶棚、墙面、地面应采用A级装修材料，其余部位应不低于B1级装修材料",{"key":121,"text":122,"correct":29},"E","水泵房、空调机房、配电室所有部位均应采用A级装修材料","BE",{"id":125,"libraryId":5,"type":108,"typeLabel":109,"stem":126,"options":127,"answer":138,"analysis":33},935741,"下列关于多层建筑室内装修材料的说法，正确的是（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":22},"观众厅、多功能厅的顶棚、墙面装修材料不应低于A级，其它不低于B1级",{"key":24,"text":131,"correct":29},"养老院、幼儿院的顶棚、墙面装修材料不应低于A级，地面不应低于B1级",{"key":27,"text":133,"correct":29},"B级信息机房的顶棚、墙面装修材料不应低于A级，其它不低于B1级",{"key":31,"text":135,"correct":29},"存放文物、贵重图书档案的场所的顶棚、墙面装修材料不应低于A级，地面不应低于B1级",{"key":121,"text":137,"correct":22},"歌舞娱乐场所的顶棚、墙面装修材料不应低于A级，地面不应低于B1级","BCD",{"id":140,"libraryId":5,"type":108,"typeLabel":109,"stem":141,"options":142,"answer":153,"analysis":33},935742,"某购物中心，地上7层，层高4m，建筑高度28m，每层建筑而积均为4000㎡，设置符合规范要求的条件后，每层划分为一个防火分区，下列有关其商店营业厅选用的内部装修材料描述中，表述正确的是（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":29},"顶棚采用安装在钢龙骨上的矿棉吸声板",{"key":24,"text":146,"correct":22},"顶棚采用铝箔复合材料",{"key":27,"text":148,"correct":29},"墙面采用防火塑料装饰板",{"key":31,"text":150,"correct":22},"墙面采用塑料贴面装饰板",{"key":121,"text":152,"correct":29},"地面采用水泥木丝板","ACE",{"id":155,"libraryId":5,"type":108,"typeLabel":109,"stem":156,"options":157,"answer":168,"analysis":33},935743,"下列关于建筑的外墙保温系统防护层的做法正确的是（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":22},"某建筑采用内保温系统，保温材料为A级，未设置防护层",{"key":24,"text":161,"correct":22},"某建筑采用内保温系统，保温材料为B2级，防护层厚度10mm",{"key":27,"text":163,"correct":22},"某建筑采用外保温系统，保温材料为B2级，首层的防护层厚度10mm",{"key":31,"text":165,"correct":29},"某建筑采用外保温系统，保温材料为B1级，非首层的防护层厚度5mm",{"key":121,"text":167,"correct":29},"某建筑的屋面保温系统，采用B2级保温材料，防护层厚度10mm","DE",{"id":170,"libraryId":5,"type":108,"typeLabel":109,"stem":171,"options":172,"answer":183,"analysis":33},935744,"关于建筑的外墙保温系统的说法不符合规范的是（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"采用A级材料外墙内保温系统可不设防火隔离带",{"key":24,"text":176,"correct":22},"采用非A级材料的外保温系统应设置防火隔离带",{"key":27,"text":178,"correct":29},"采用非A级材料的屋面外保温系统，屋面与外墙之间应设置宽度不小于500mm的防火隔离带",{"key":31,"text":180,"correct":22},"采用非A级材料的外墙外保温系统，每层应设置高度不小于300mm不燃的防火隔离带",{"key":121,"text":182,"correct":29},"建筑外墙的装饰层应采用A级材料","CE",{"id":185,"libraryId":5,"type":108,"typeLabel":109,"stem":186,"options":187,"answer":153,"analysis":33},935745,"某建筑高度为62m的宾馆，附没裙房，地上5层，层高4m，每层建筑面积1600m2，裙房首层为商店营业厅，采用耐火极限为2．0h的防火隔墙分隔为多个建筑面积为120m2-450m2的商铺，每个商铺与商场的连通处均采用乙级防火门分隔，该裙房按照国家规定设置了相应的消防设施，则下列关于该裙房内有窗商铺内部装修的做法中，符合规范要求的有（ ）。",[188,190,192,194,196],{"key":20,"text":189,"correct":29},"墙面采用多彩涂料装修",{"key":24,"text":191,"correct":22},"地面铺装半硬质PVC塑料地板",{"key":27,"text":193,"correct":29},"窗帘采用经阻燃处理的难燃织物",{"key":31,"text":195,"correct":22},"顶棚采用矿棉板装修",{"key":121,"text":197,"correct":29},"隔断采用彩色阻燃人造板装修",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},935746,"关于地下建筑的室内装修材料燃烧性能等级的说法，下列表述正确的是（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":29},"地下歌舞娱乐场所的内部装修材料燃烧性能，顶棚、墙面不应低于A级，地面不应低于B1级",{"key":24,"text":205,"correct":22},"地下观众厅的内部装修材料燃烧性能等级中，顶棚、墙面不应低于A级，地面不应低于B1级",{"key":27,"text":207,"correct":22},"地下存放文物场所的内部装修材料燃烧性能等级中，顶棚、墙面不应低于A级，地面不应低于B1级",{"key":31,"text":209,"correct":22},"地下餐饮场所的内部装修材料燃烧性能等级中，顶棚、墙面不应低于A级，地面不应低于B1级",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":31,"analysis":33},935747,"下列装修材料进场应进行抽样检验的是（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"B2级装修材料",{"key":24,"text":217,"correct":22},"B1级装修材料",{"key":27,"text":219,"correct":22},"现场阻燃处理所使用的阻燃剂及防火涂料",{"key":31,"text":221,"correct":29},"现场进行阻燃处理的复合材料",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":31,"analysis":33},935748,"某商业建筑，建筑高度为24m，建筑外墙采用外保温系统，保温材料的燃烧性能为B1级，下列做法中错误的（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"建筑外墙上门、窗的耐火完整性为0．50h",{"key":24,"text":229,"correct":22},"在保温系统中每层设置防火隔离带，防火隔离带的燃烧性能为A级",{"key":27,"text":231,"correct":22},"设置的防火隔离带的高度为300mm",{"key":31,"text":233,"correct":29},"保温层外设防护层，首层采用厚度为10mm的B1级材料",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":33},935749,"下列建筑外墙所采用的装饰材料不符合相关规范要求的是（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":29},"建筑高度为20m的办公楼，外墙采用B2级装修材料",{"key":24,"text":241,"correct":22},"建筑高度为18 m的商场，外墙采用B1级装修材料",{"key":27,"text":243,"correct":22},"建筑高度为54 m的高级酒店，外墙采用A级装修材料",{"key":31,"text":245,"correct":22},"建筑高度为28 m的展览馆，外墙采用B1级装修材料",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},935750,"当开关、插座、配电箱的基座材料燃烧性能等级为B2级时，为防止电气火灾，必须采用具有良好隔热性能的（ ）进行隔绝。",[250,252,254,256],{"key":20,"text":251,"correct":22},"易燃材料",{"key":24,"text":253,"correct":22},"可燃材料",{"key":27,"text":255,"correct":22},"难燃材料",{"key":31,"text":257,"correct":29},"不燃材料",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":33},935751,"根据《建筑内部装修设计防火规范》（GB50222），对商场设置的防烟楼梯间的内装修材料进行检查时，符合规范要求的做法是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":29},"顶棚、墙面和地面的装修材料的燃烧性能等级分别为 A、 A、A",{"key":24,"text":265,"correct":22},"顶棚、墙面和地面的装修材料的燃烧性能等级分别为 A、 A、B1",{"key":27,"text":267,"correct":22},"顶棚、墙面和地面的装修材料的燃烧性能等级分别为B1、A",{"key":31,"text":267,"correct":22},{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":27,"analysis":33},935752,"在建筑内部装修施工过程中，应分阶段对所选用的防火装修材料按规定进行抽样检验，对于在现场进行阻燃处理的施工，应（ ）进行抽样检验。",[273,275,277,279],{"key":20,"text":274,"correct":22},"在相应的施工作业前",{"key":24,"text":276,"correct":22},"在相应的施工作业中",{"key":27,"text":278,"correct":29},"在相应的施工作业完成后",{"key":31,"text":280,"correct":22},"由监理工程师根据施工作业进度",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":33},935753,"下列建筑均采用与基层墙体、装饰层之间无空腔的建筑外墙外保温系统，保温材料的选择不符合规范要求的是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"建筑高度24m的住宅建筑，建筑外墙外保温材料采用EPS板",{"key":24,"text":288,"correct":29},"建筑高度为52m的办公建筑，建筑外墙外保温材料采用硬泡聚氨酯",{"key":27,"text":290,"correct":22},"建筑高度为70m的住宅建筑，建筑外墙外保温材料采用胶粉聚苯颗粒保温浆料",{"key":31,"text":292,"correct":22},"建筑高度为23．8m的办公建筑，建筑外墙外保温材料采用XPS板",{"id":294,"libraryId":5,"type":108,"typeLabel":109,"stem":295,"options":296,"answer":307,"analysis":33},935754,"除了不允许放宽的场所外，下列关于室内装修材料燃烧性能等级放宽条件的说法，符合规范的是（ ）。",[297,299,301,303,305],{"key":20,"text":298,"correct":29},"面积小于100㎡的单、多层民用建筑的房间，当采用耐火极限不低于2.00h的防火隔墙和甲级防火门、窗与其他部位分隔时，其装修材料的燃烧性能等级可降低一级",{"key":24,"text":300,"correct":29},"当单层、多层民用建筑内的场所设置自动灭火系统时，除顶棚外，其装修材料的燃烧性能等级可降低一级",{"key":27,"text":302,"correct":29},"当单层、多层民用建筑内的场所同时设置自动灭火系统和火灾自动报警系统时，其装修材料的燃烧性能等级均可降低一级",{"key":31,"text":304,"correct":22},"高层层民用建筑内的场所同时设置自动灭火系统和火灾自动报警系统时，其装修材料的燃烧性能等级均可降低一级",{"key":121,"text":306,"correct":22},"高层民用建筑的裙房内面积500㎡的房间，当设有自动灭火系统，并且采用耐火极限不低于2．00h的防火隔墙和甲级防火门、窗与其他部位分隔时，其装修材料的燃烧性能等级均可降低一级","ABC",{"id":309,"libraryId":5,"type":108,"typeLabel":109,"stem":310,"options":311,"answer":322,"analysis":33},935755,"建筑外墙外保温系统按规定采用B1、B2级保温材料时，下列选项中符合规定的有（ ）。",[312,314,316,318,320],{"key":20,"text":313,"correct":29},"采用B2级保温材料的建筑，建筑外墙上的门、窗的耐火完整性不应低于0．5h",{"key":24,"text":315,"correct":22},"采用B1级保温材料且建筑高度不大于27m的住宅建筑，建筑外墙上的门、窗的耐火完整性不应低于0．50h",{"key":27,"text":317,"correct":22},"采用B1级保温材料且建筑高度不大于24m的公共建筑，建筑外墙上的门、窗的耐火完整性不应低于0．50h",{"key":31,"text":319,"correct":29},"采用B1级保温材料且建筑高度大于27m的住宅建筑，建筑外墙上的门、窗的耐火完整性不应低于0．50h",{"key":121,"text":321,"correct":29},"采用B1级保温材料且建筑高度大于24m的公共建筑，建筑外墙上的门、窗的耐火完整性不应低于0．50h","ADE",{"id":324,"libraryId":5,"type":108,"typeLabel":109,"stem":325,"options":326,"answer":337,"analysis":33},935756,"某大型商场地下二层，每层建筑面积为10000m2，地下二层室内地面与室外出入口地坪高差为12m，地下商场均设有火灾自动报警系统和自动灭火系统，装修材料均采用不燃或难燃材料。下列关于该商场消防设计的说法中，符合规定的是（ ）。",[327,329,331,333,335],{"key":20,"text":328,"correct":29},"该商场的疏散楼梯采用防烟楼梯间",{"key":24,"text":330,"correct":29},"该商场每层划分5个防火分区",{"key":27,"text":332,"correct":29},"位于该商场地下一层的游艺厅顶棚采用A级装修材料，地面采用A级装修材料",{"key":31,"text":334,"correct":22},"该商场的建筑构件均采用不燃性材料，疏散楼梯的耐火极限为1．00h",{"key":121,"text":336,"correct":29},"位于该商场地下一层的游艺厅顶棚、墙面采用A级装修材料，地面采用B1级装修材料","ABCE",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},935757,"某民用建筑要对其内部进行装修，则对其内部的装修材料选择的最低要求，不正确的是（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"设置在地下一层的消防水泵房内部装修采用A级材料",{"key":24,"text":345,"correct":29},"地上无窗的封闭楼梯间顶棚采用A级装修材料，地面采用B1级装修材料",{"key":27,"text":347,"correct":22},"空调机房全部采用A级装修材料",{"key":31,"text":349,"correct":22},"中庭顶棚采用A级装修材料，地面采用B1级装修材料",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":31,"analysis":33},935758,"在对建筑外墙装饰材料进行的防火检查中，下列不符合相关规范要求的是（）。 某综合楼，地上10层，建筑外墙采用铝扣板装饰 某超高层办公楼的裙房建筑外墙采用木纹金属板装饰 某档案馆，建筑高度40m，地上一至四层的建筑外墙采用PVC塑料板墙板装饰 某星级酒店，地上20层，建筑外墙采用难燃仿花岗岩装饰板装饰",[354,355,356,357],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},935759,"下列关于多层养老院的内部装修材料中，说法错误的是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"顶棚采用安装在钢龙骨上的纸面石膏板",{"key":24,"text":365,"correct":29},"墙面采用表面涂覆一级饰面型防火涂料的胶合板",{"key":27,"text":367,"correct":22},"地面采用瓷砖",{"key":31,"text":369,"correct":22},"隔断采用阻燃模压木质复合板材",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":31,"analysis":33},935760,"某存放国家级重要档案的建筑，建筑高度为26m，已按现行相关国家工程建设消防技术标准的有关规定设置了消防设施，下列关于其内部装修材料燃烧性能的说法正确的是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"所有部位均可降一级",{"key":24,"text":377,"correct":22},"除顶棚外，其他部位可降一级",{"key":27,"text":379,"correct":22},"顶棚降一级，其他部位不限",{"key":31,"text":381,"correct":29},"所有部位均不应降级",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":24,"analysis":33},935761,"某施工单位对多功能厅进行装修，其中吊顶采用钢龙骨矿棉吸声板，地面铺设地毯，墙面采用不同装修材料进行分层装修，关于该多功能厅内部装饰的说法中错误的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"矿棉吸声板装在钢龙骨上时，可作为A级材料使用",{"key":24,"text":389,"correct":29},"墙面分层装修材料除表面层的燃烧性能等级应符合规范要求外，其余各层的燃烧性能等级不限",{"key":27,"text":391,"correct":22},"地毯应使用阻燃制品，并加贴阻燃标识",{"key":31,"text":393,"correct":22},"进入施工现场的装修材料应按要求进行见证取样检验",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":31,"analysis":33},935762,"下列关于建筑内部装修材料的检查，不符合规范要求的是（ ）",[398,400,402,404],{"key":20,"text":399,"correct":22},"配电箱直接安装在B1级的装修材料上",{"key":24,"text":401,"correct":22},"灯饰所用材料的燃烧性能等级为B1级",{"key":27,"text":403,"correct":22},"把表面涂覆一级饰面型防火涂料的胶合板作为B1级装修材料使用",{"key":31,"text":405,"correct":29},"当胶合板用于顶棚和墙面装修并且内含有电器、电线等物体时，对隐蔽层检查时，应查阅隐蔽工程验收记录，根据情况确定是否进行现场核查",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},935763,"对民用建筑进行防火检查，应注意该场所各个不同部位所使用装修材料的燃烧性能等级是否符合要求，下列场所中，墙面、地面和顶棚的装修材料的燃烧性能等级与其它选项不同的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":29},"某建筑高度为26m的医院门诊楼疏散走道",{"key":24,"text":413,"correct":22},"某地下一层的商场疏散走道",{"key":27,"text":415,"correct":22},"某建筑高度为54m办公楼的防烟楼梯间前室",{"key":31,"text":417,"correct":22},"某建筑高度为32m的住宅建筑的封闭楼梯间",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":24,"analysis":33},935764,"一个长 10m,宽 8m,高 3m 的房间,门窗面积共 8 ㎡,现采用厚度为15mm多孔塑料板装修,顶棚已使用了4㎡，墙面最多还可以使用（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":22},"14.8 ㎡",{"key":24,"text":425,"correct":29},"10.8 ㎡",{"key":27,"text":427,"correct":22},"14 ㎡",{"key":31,"text":429,"correct":22},"10 ㎡",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":20,"analysis":33},935765,"当外墙体保温材料选用非（ ）级材料时，应检查其外侧是否按要求设置不燃材料制作的防护层。",[434,435,436,438],{"key":20,"text":20,"correct":29},{"key":24,"text":39,"correct":22},{"key":27,"text":437,"correct":22},"B2",{"key":31,"text":439,"correct":22},"B3",{"id":441,"libraryId":5,"type":108,"typeLabel":109,"stem":442,"options":443,"answer":454,"analysis":33},935766,"下列关于建筑内部装修材料燃烧性能等级分类的说法中，错误的是（ ）。",[444,446,448,450,452],{"key":20,"text":445,"correct":22},"玻璃属于A级装修材料，岩棉装饰板属于B1级装修材料",{"key":24,"text":447,"correct":29},"难燃刨花板属于B2级装修材料，水泥刨花板属于B1级装修材料",{"key":27,"text":449,"correct":29},"PVC塑料护墙板、半硬PVC塑料地板属于B1级装修材料",{"key":31,"text":451,"correct":22},"阻燃聚氨酯属于B2级装修材料，复合壁纸属于B2级装修材料",{"key":121,"text":453,"correct":29},"难燃仿花岗岩装饰板、经阻燃处理的聚乙烯属于B1级装修材料","BCE",{"id":456,"libraryId":5,"type":108,"typeLabel":109,"stem":457,"options":458,"answer":469,"analysis":33},935767,"下列关于多层民用建筑各部位所使用的室内装修材料，表述正确的是（ ）。",[459,461,463,465,467],{"key":20,"text":460,"correct":29},"图书馆的顶棚装修材料不应低于A级，墙面、地面装修材料不应低于B1级",{"key":24,"text":462,"correct":29},"商场营业厅的顶棚装修材料不应低于A级，墙面、地面装修材料不应低于B1级",{"key":27,"text":464,"correct":22},"餐饮场所的顶棚装修材料不应低于A级，墙面、地面装修材料不应低于B1级",{"key":31,"text":466,"correct":22},"教学实验场所的顶棚装修材料不应低于A级，墙面、地面装修材料不应低于B1级",{"key":121,"text":468,"correct":22},"办公场所的顶棚装修材料不应低于A级，墙面、地面装修材料不应低于B1级","AB",{"id":471,"libraryId":5,"type":108,"typeLabel":109,"stem":472,"options":473,"answer":483,"analysis":33},935768,"对于（ ），以及各类建筑内的避难走道、避难间、避难层等场所或部位，建筑外墙内保温系统应采用燃烧性能为A级的保温材料。",[474,476,478,479,481],{"key":20,"text":475,"correct":29},"人员密集场所",{"key":24,"text":477,"correct":29},"用火、燃油、燃气等具有火灾危险性的场所",{"key":27,"text":89,"correct":22},{"key":31,"text":480,"correct":22},"民用建筑内的疏散走道",{"key":121,"text":482,"correct":29},"敞开楼梯间","ABE",{"id":485,"libraryId":5,"type":108,"typeLabel":109,"stem":486,"options":487,"answer":498,"analysis":33},935769,"某办公楼建筑，二级耐火等级，首层地面标高为±0．000m，室外地坪标高为-0．400m，平屋面面层标高为49．600m。对该办公楼外墙外保温系统进行设计，下列提议符合规范要求的有（ ）。",[488,490,492,494,496],{"key":20,"text":489,"correct":29},"外保温体系与基层墙体无空腔，保温材料采用矿棉板",{"key":24,"text":491,"correct":29},"当保温材料采用难燃聚氨酯泡沫板时，建筑二层及以上防护层厚度为5mm",{"key":27,"text":493,"correct":22},"当保温材料采用难燃聚氨酯泡沫板时，建筑防护层首层厚度为10mm",{"key":31,"text":495,"correct":29},"外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B1级的聚氨酯泡沫板",{"key":121,"text":497,"correct":22},"外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B2级的聚苯乙烯泡沫板","ABD",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":27,"analysis":33},935770,"消防产品一致性检查是防止使用假冒伪劣消防产品施工、降低消防设施施工安装质量的有效手段，下列检查内容不是消防产品一致性检查的是（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"逐一登记到场的各类消防设施的设备及其组件名称、批次、规格型号、数量和生产厂名、地址和产地，与其设备清单、使用说明书等核对无误",{"key":24,"text":506,"correct":22},"查验各类消防设施的设备及其组件的规格型号、组件配置及其数量、性能参数、生产厂名及其地址与产地，以及标志、外观、材料、产品实物等，与经国家消防产品法定检验机构检验合格的型式检验报告一致",{"key":27,"text":508,"correct":29},"查验所有消防产品、管材管件及其他设备的出厂检验报告或者出厂合格证",{"key":31,"text":510,"correct":22},"查验各类消防设施的设备及其组件规格型号，符合经法定机构批准或者备案的消防设计文件要求",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":20,"analysis":33},935771,"《消防控制室值班记录表》和《建筑消防设施巡查记录表》的存档时间不少于（ ）年。",[515,517,519,521],{"key":20,"text":516,"correct":29},"一",{"key":24,"text":518,"correct":22},"二",{"key":27,"text":520,"correct":22},"三",{"key":31,"text":522,"correct":22},"四",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":31,"analysis":33},935772,"消防设施施工结束后，由建设单位组织设计、施工、监理等单位进行包括消防设施在内的建设工程竣工验收。消防设施竣工验收前，施工单位需要提交的竣工验收资料不包括（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"竣工验收申请报告",{"key":24,"text":530,"correct":22},"消防设计审核意见书和设计变更通知书",{"key":27,"text":532,"correct":22},"施工现场质量管理检查记录、施工过程质量管理检查记录以及工程质量事故处理报告",{"key":31,"text":534,"correct":29},"施工许可证",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":27,"analysis":33},935773,"消防机构对某综合楼设置的自动喷水灭火系统进行竣工验收，发现报警阀组无法实现报警功能，下列关于该质量问题处理的说法不正确的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"调整报警阀相关组件后，重新组织竣工验收",{"key":24,"text":542,"correct":22},"经过重新安装后仍然无法实现报警功能，判定竣工验收不合格",{"key":27,"text":544,"correct":29},"经检查报警管路未按图纸进行安装，重新按照图纸安装后判定验收合格",{"key":31,"text":546,"correct":22},"更换一台新的报警阀，但是安装前应重新组织现场检查",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":31,"analysis":33},935774,"某施工单位对采购的消防设备进行现场检查，下列不属于消防设施现场检查内容的是（ ）。",[551,553,555,557],{"key":20,"text":552,"correct":22},"市场准入文件检查",{"key":24,"text":554,"correct":22},"消防设备规格型号检查",{"key":27,"text":556,"correct":22},"组件装配及其结构检查",{"key":31,"text":558,"correct":29},"系统施工详图检查",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":31,"analysis":33},935775,"灭火器验收检查时对发现的缺陷项按规定可划分为严重缺陷项、重缺陷项和轻缺陷项，下列属于重缺陷项的是（ ）。",[563,565,567,569],{"key":20,"text":564,"correct":22},"计算单元配置内采用不同的灭火器，其灭火剂不相容",{"key":24,"text":566,"correct":22},"计算单元配置的灭火级别不够",{"key":27,"text":568,"correct":22},"灭火器选型不符合设计要求",{"key":31,"text":570,"correct":29},"灭火器设置点附近有影响人员疏散的障碍物",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":27,"analysis":33},935776,"消防控制室图形显示装置（ ）s 内能够显示输入的火灾报警信号和反馈信号的状态信息。采用中文标注和中文界面的消防控制室图形显示装置,其界面对角线长度不得小于（ ）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"3,430",{"key":24,"text":578,"correct":22},"5,430",{"key":27,"text":580,"correct":29},"10,430",{"key":31,"text":582,"correct":22},"15,430",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":24,"analysis":33},935777,"建筑使用管理单位在安排消防控制室值班时，实行每日24h专人值班制度，每班不少于（ ）人，值班人员持有规定的消防专业技能鉴定证书。",[587,588,590,591],{"key":20,"text":516,"correct":22},{"key":24,"text":589,"correct":29},"两",{"key":27,"text":520,"correct":22},{"key":31,"text":522,"correct":22},{"id":593,"libraryId":5,"type":108,"typeLabel":109,"stem":594,"options":595,"answer":337,"analysis":33},935779,"消防设计文件包括消防设施设计施工图以及设计说明，其中消防设施施工图包括（ ）。",[596,598,600,602,604],{"key":20,"text":597,"correct":29},"平面图",{"key":24,"text":599,"correct":29},"系统图",{"key":27,"text":601,"correct":29},"设备表",{"key":31,"text":603,"correct":22},"消防设施检测记录表",{"key":121,"text":605,"correct":29},"材料表",{"id":607,"libraryId":5,"type":108,"typeLabel":109,"stem":608,"options":609,"answer":337,"analysis":33},935780,"消防产品合法性检查，要重点查验其符合国家市场准入规定的相关合法性文件和产品质量检验文件，下列关于合法性检查的说法中，正确的有（ ）。",[610,612,614,616,618],{"key":20,"text":611,"correct":29},"纳入强制性产品认证的消防产品，查验其依法获得的强制认证证书",{"key":24,"text":613,"correct":29},"新研制的尚未制定国家或者行业标准的消防产品，查验其依法获得的技术鉴定证书",{"key":27,"text":615,"correct":29},"尚未纳入强制性产品认证的非新产品类的消防产品，查验其经国家法定消防产品检验机构检验合格的型式检验报告",{"key":31,"text":617,"correct":22},"非消防产品类的管材管件以及其他设备查验其出厂质保文件",{"key":121,"text":619,"correct":29},"查验所有消防产品、管材管件以及其他设备的出厂检验报告或者出厂合格证",{"id":621,"libraryId":5,"type":108,"typeLabel":109,"stem":622,"options":623,"answer":337,"analysis":33},935781,"为确保施工质量，施工过程中要建立健全施工质量管理体系和工程质量检验制度，下列施工过程中关于质量控制要求的说法中，不正确的是（ ）。",[624,626,628,630,632],{"key":20,"text":625,"correct":29},"消防设施安装完毕，建设单位应按照相关专业调试规定进行调试",{"key":24,"text":627,"correct":29},"各工序严格按照施工技术标准的顺序，每道工序完成后可直接进入下一道工序",{"key":27,"text":629,"correct":29},"对到场的各类消防设施的设备、组件以及材料进行外观检查合格后，后方可施工",{"key":31,"text":631,"correct":22},"调试结束后，施工单位向建设单位提供质量控制资料和各类消防设施施工过程质量检查记录",{"key":121,"text":633,"correct":29},"相关各专业工种之间交接时，进行检验认可，经项目经理签证后，方可进行下一道工序",{"id":635,"libraryId":5,"type":108,"typeLabel":109,"stem":636,"options":637,"answer":648,"analysis":33},935782,"下列关于消防系统质量验收判定的说法中，不正确的是（ ）。",[638,640,642,644,646],{"key":20,"text":639,"correct":22},"防排烟系统当A=0，且B=2，且B+C=4时，竣工验收判定为合格",{"key":24,"text":641,"correct":29},"灭火器的配置验收当A=0，且B=2，B+C=4时，竣工验收判定为合格",{"key":27,"text":643,"correct":29},"自动喷水灭火系统当A=0，且B=3，且B+C=6时，竣工验收判定为合格",{"key":31,"text":645,"correct":29},"泡沫灭火系统当A=0，且B=0，C=1时，竣工验收判定为合格",{"key":121,"text":647,"correct":29},"火灾自动报警系统当A=0，且B=2，且B+C=检查项的5％时，竣工验收判定为不合格","BCDE",{"id":650,"libraryId":5,"type":15,"typeLabel":16,"stem":651,"options":652,"answer":20,"analysis":33},935783,"建筑消防设施档案有一定的保存期限，其中《消防控制室值班记录表》的存档时间为（ ）。",[653,655,657,659],{"key":20,"text":654,"correct":29},"不少于1年",{"key":24,"text":656,"correct":22},"不少于5年",{"key":27,"text":658,"correct":22},"不少于10年",{"key":31,"text":660,"correct":22},"永久",[662,665,668,671,674,677],{"id":15,"name":663,"category":7,"favorite":664},"领导干部任职前廉政法规知识测试题",92,{"id":666,"name":667,"category":7,"favorite":15},595,"建筑结构与设备",{"id":669,"name":670,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":672,"name":673,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":675,"name":676,"category":7,"favorite":8},534,"BIM工程师",{"id":678,"name":676,"category":7,"favorite":8},535]