[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":668},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,21,50,2974,[13,34,46,58,70,82,94,106,118,130,142,160,174,189,204,219,234,248,263,277,292,306,318,330,342,354,366,378,390,402,416,430,441,453,465,477,486,501,514,529,540,555,567,578,590,602,614,628,642,656],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},935683,1,"单选题","对多层煤粉厂房进行防火检查，查阅资料得知，该厂房耐火等级一级，设置自动喷水灭火系统，则该厂房内任意一点到最近安全出口的直线距离不应大于（ ）m。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","30",false,{"key":24,"text":25,"correct":26},"B","50",true,{"key":28,"text":29,"correct":22},"C","75",{"key":31,"text":32,"correct":22},"D","60","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},935684,"某建筑高度为22 m的办公楼，地上6层，耐火等级为二级，第四层使用人数最多，为400人，第五、六层每层的人数均为200人，则第四层和第五层楼梯的最小疏散总宽度分别不小于（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"2．0m、2．0m",{"key":24,"text":41,"correct":22},"4．0m、3．0m",{"key":28,"text":43,"correct":22},"5．0m、2．0m",{"key":31,"text":45,"correct":22},"5．0m、3．0m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},935685,"某建筑高度为180m的超高层综合楼，关于它的避难层的设置，下列说法错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"采用燃烧性能为A级的保温材料",{"key":24,"text":53,"correct":22},"当兼做设备层时，设备管道区采用耐火极限不低于3．00h的防火隔墙与避难区分隔",{"key":28,"text":55,"correct":26},"避难层内疏散照明的地面水平照度为1．0lx",{"key":31,"text":57,"correct":22},"设置直接对外可开启的乙级防火窗",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},935686,"疏散门的形式根据建筑类别、使用性质进行确定，下列关于不同类型建筑疏散门形式选用的说法中，正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"住宅建筑的疏散门可以采用吊门",{"key":24,"text":65,"correct":22},"剧场的疏散门可以采用甲级自动推闩式内开门",{"key":28,"text":67,"correct":22},"丁类厂房的疏散门可以采用卷帘门",{"key":31,"text":69,"correct":26},"丙类仓库首层靠墙的外侧疏散门可以采用推拉门",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},935687,"进出医院门诊大厅的疏散门，其净宽度和数量应根据疏散人数通过计算确定，并应满足每个疏散门不应小于（ ）m的要求。",[74,76,78,80],{"key":20,"text":75,"correct":22},"1．1",{"key":24,"text":77,"correct":22},"1．3",{"key":28,"text":79,"correct":22},"1．5",{"key":31,"text":81,"correct":26},"1．4",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},935688,"对于民用建筑进行防火检查，下列关于建筑内疏散门的检查结果中，符合规范要求的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"位于地下一层的KTV疏散走道两侧的一个房间，建筑面积为40m2，可容纳10人，设1个疏散门",{"key":24,"text":89,"correct":22},"位于地上二层袋形走道两侧的幼儿园房间，建筑面积65m2，设1个疏散门",{"key":28,"text":91,"correct":22},"教学楼地上三层袋形走道尽端的教室，建筑面积40m2，设1个疏散门",{"key":31,"text":93,"correct":22},"医院地上四层疏散走道两侧的病房，建筑面积80m2，设1个疏散门",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},935689,"对民用建筑进行防火检查，下列关于安全出口和疏散楼梯的检查结果，符合规范要求的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"某独立建造的地上3层KTV，每层建筑面积200m2且使用人数为25人，设一部疏散楼梯",{"key":24,"text":101,"correct":22},"某三级耐火等级的地上2层餐馆，每层建筑面积180m2，二层使用人数30人，设一部疏散楼梯",{"key":28,"text":103,"correct":22},"某单层商店，建筑面积220m2，使用人数为50人，设一个安全出口",{"key":31,"text":105,"correct":26},"某地上8层办公楼，层高3m，每层建筑面积1200m2且使用人数为120人，设2部净宽度为1．2m的封闭楼梯间",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},935690,"对建筑进行防火检查，下列场所疏散门或疏散楼梯间的设置，符合规范要求的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"某建筑面积为500m2的地下一层录像厅，室内外高差4．5m，设置3部净宽度均为1．5m的封闭楼梯间",{"key":24,"text":113,"correct":22},"某地上3层的纺织厂，每层为一个防火分区且使用人数为190人，设2部净宽度为0．9m的封闭楼梯间",{"key":28,"text":115,"correct":26},"某高层办公楼，每层为一个防火分区且使用人数为260人，设2部净宽为1．4m的防烟楼梯间",{"key":31,"text":117,"correct":22},"某地上4层门诊楼，首层门诊大厅设置的疏散门净宽度为1．3m",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},935691,"对下列建筑进行防火检查，关于安全出口和疏散门的检查结果，不符合相关规范要求的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"某地上6层的综合楼，封闭楼梯间采用乙级防火门，并向疏散方向开启",{"key":24,"text":125,"correct":26},"某单层服装加工厂房，首层靠墙的外侧采用金属卷帘门",{"key":28,"text":127,"correct":22},"某木器加工厂房的室外楼梯采用向外开启的乙级防火门，疏散门不正对梯段",{"key":31,"text":129,"correct":22},"某建筑高度24m的住宅建筑，设置敞开式楼梯间，户门采用乙级防火门",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},935692,"当仓库仅设一个安全出口时，检查要求正确的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"仓库占地面积不大于400m2",{"key":24,"text":137,"correct":22},"仓库防火分区的建筑面积小于等于120m2",{"key":28,"text":139,"correct":22},"地下、半地下仓库的建筑面积小于等于120m2",{"key":31,"text":141,"correct":26},"仓库的地下室、半地下室的建筑面积小于等于100m2",{"id":143,"libraryId":5,"type":144,"typeLabel":145,"stem":146,"options":147,"answer":159,"analysis":33},935693,2,"多选题","厂房、库房中关于疏散楼梯的选用，说法正确的是（ ）",[148,150,152,154,156],{"key":20,"text":149,"correct":26},"甲、乙、丙类多层厂房和高层厂房的疏散楼梯采用封闭楼梯间或室外楼梯",{"key":24,"text":151,"correct":26},"建筑高度大于32m且任一层人数超过10人的高层厂房，采用防烟楼梯间或室外楼梯",{"key":28,"text":153,"correct":22},"建筑高度大于50m且任一层人数超过15人的高层厂房，采用封闭楼梯间",{"key":31,"text":155,"correct":26},"高层仓库采用封闭楼梯间",{"key":157,"text":158,"correct":22},"E","甲、乙类多层厂房和高层厂房的疏散楼梯应采用防烟楼梯间","ABD",{"id":161,"libraryId":5,"type":144,"typeLabel":145,"stem":162,"options":163,"answer":159,"analysis":33},935694,"下列可以设置一个安全出口或一部疏散楼梯的有（）。",[164,166,168,170,172],{"key":20,"text":165,"correct":26},"除歌舞娱乐放映游艺场所外，防火分区建筑面积不大于200m2的地下或半地下设备房间、防火分区建筑面积不大于50m2且经常停留人数不超过15人的其他地下或半地下建筑（室）",{"key":24,"text":167,"correct":26},"除托儿所、幼儿园外单层公共建筑或多层公共建筑的首层，建筑面积小于等于200m2且人数不超过50人",{"key":28,"text":169,"correct":22},"建筑高度不大于27m的住宅，每个单元任一层的建筑面积小于650m2且任一户门至最近安全出口的距离小于20m",{"key":31,"text":171,"correct":26},"除医疗建筑，老年人建筑，托儿所、幼儿园的儿童用房，儿童游乐厅等儿童活动场所和歌舞娱乐放映游艺场所等外，耐火等级、建筑层数、每层最大建筑面积和使用人数符合相关规定的公共建筑",{"key":157,"text":173,"correct":22},"建筑高度大于27m、不大于54m的住宅，每个单元任一层的建筑面积小于650m2，且任一户门至最近安全出口的距离小于10m",{"id":175,"libraryId":5,"type":144,"typeLabel":145,"stem":176,"options":177,"answer":188,"analysis":33},935695,"下列建筑应设置封闭楼梯间的是（ ）。",[178,180,182,184,186],{"key":20,"text":179,"correct":22},"某建筑高度33m设有敞开式外廊的旅馆",{"key":24,"text":181,"correct":26},"某建筑高度32m设有敞开式外廊的教学楼",{"key":28,"text":183,"correct":22},"某建筑高度21m的住宅，楼梯间与电梯井相邻，住宅户门采用乙级防火门",{"key":31,"text":185,"correct":26},"地下两层的服装仓库，每层层高3．8m",{"key":157,"text":187,"correct":22},"地下一、二层为商场，地下三层为汽车库的建筑","BD",{"id":190,"libraryId":5,"type":144,"typeLabel":145,"stem":191,"options":192,"answer":203,"analysis":33},935696,"下列选项中使用面积不应小于6㎡的有（ ）。",[193,195,197,199,201],{"key":20,"text":194,"correct":26},"公共建筑防烟楼梯间前室",{"key":24,"text":196,"correct":22},"防火隔间",{"key":28,"text":198,"correct":26},"消防电梯前室",{"key":31,"text":200,"correct":26},"住宅建筑剪刀楼梯间的共用前室",{"key":157,"text":202,"correct":22},"住宅建筑的防烟楼梯间前室","ACD",{"id":205,"libraryId":5,"type":144,"typeLabel":145,"stem":206,"options":207,"answer":218,"analysis":33},935697,"下列建筑可设置一部疏散楼梯的是（ ）。",[208,210,212,214,216],{"key":20,"text":209,"correct":26},"一级耐火等级的公共建筑，设有2部疏散楼梯，建筑为高度15m的教学建筑，该建筑局部高出部分为2层，每层建筑面积为200㎡，每层使用人数25人，设置1个直通建筑主体上人平屋面的安全出口，且上人屋面符合人员安全疏散的要求",{"key":24,"text":211,"correct":22},"某建筑高度为28m的旅馆的局部高出部分，局部高出2层，每层建筑面积为200㎡，每层人数25人，设置1个直通建筑主体以平屋面的安全出口",{"key":28,"text":213,"correct":26},"某建筑高度为27m的住宅，每个单元每层建筑面积均为650㎡，且任一户门至最近安全出口的不大于13m",{"key":31,"text":215,"correct":22},"某建筑高度为34m的住宅，每个单元每层建筑面积均为650㎡，且任一户门至最近安全出口的距离不大于1m",{"key":157,"text":217,"correct":22},"某建筑高度为55m的住宅，每个单元每层建筑面积均650㎡，且任一户门至最近安全出口的距离不大于9m，且楼梯能通至屋面并与相邻单元楼梯连通，户门采用乙级防火门","AC",{"id":220,"libraryId":5,"type":144,"typeLabel":145,"stem":221,"options":222,"answer":233,"analysis":33},935698,"消防机构对下列场所的安全疏散设施进行检查，其中符合要求的是（ ）。",[223,225,227,229,231],{"key":20,"text":224,"correct":26},"某占地面积为250㎡的氯酸钠仓库，设置一个安全出口",{"key":24,"text":226,"correct":26},"某建筑面积为100㎡的地下糖醛仓库，设置一部疏散楼梯",{"key":28,"text":228,"correct":26},"某建筑面积为300㎡的地下面粉仓库，采用防火墙划分为两个防火分区，较大的防火分区设置一个直通室外的安全出口，利用防火墙上通向相邻防火分区的甲级防火门作为第二安全出口",{"key":31,"text":230,"correct":22},"某建筑面积为300㎡的地下服装仓库，设置一部疏散楼梯",{"key":157,"text":232,"correct":22},"某粮食筒仓上层面积为1000㎡，作业人数为2人，设置1个安全出口。","ABC",{"id":235,"libraryId":5,"type":144,"typeLabel":145,"stem":236,"options":237,"answer":203,"analysis":33},935699,"疏散楼梯间作为竖向疏散通道，其防火及疏散能力的大小直接影响着人员的生命安全与消防队员的救灾工作，下列关于疏散楼梯间防火检查的说法中，错误的有（ ）。",[238,240,242,244,246],{"key":20,"text":239,"correct":26},"在设计人数最多的楼层，沿楼梯检查安全性和畅通性",{"key":24,"text":241,"correct":22},"在设计人数最多的楼层，选择疏散楼梯扶手与楼梯隔墙之间相对较窄处测量疏散楼梯的净宽度，并核查与消防设计文件的一致性",{"key":28,"text":243,"correct":26},"测量净宽度时，每部楼梯的测量点不少于3个，宽度测量值的允许负偏差不得大于规定值的5%",{"key":31,"text":245,"correct":26},"测量前室（合用前室）使用面积，测量值的允许正偏差不得大于规定值的5%",{"key":157,"text":247,"correct":22},"测量楼梯间（前室）疏散门的宽度，测量值的允许负偏差不得大于规定值的5%",{"id":249,"libraryId":5,"type":144,"typeLabel":145,"stem":250,"options":251,"answer":262,"analysis":33},935700,"下列各类建筑的疏散楼梯间设置形式，符合现行国家消防技术标准要求的有（ ）。",[252,254,256,258,260],{"key":20,"text":253,"correct":22},"某医院病房楼，建筑高度为26m，设置封闭楼梯间",{"key":24,"text":255,"correct":26},"某高档写字楼，建筑高度为110m，其裙房设置封闭楼梯间",{"key":28,"text":257,"correct":26},"某地下商场，地下共2层，且地下二层地面与室外地坪高差为9m，设置封闭楼梯间",{"key":31,"text":259,"correct":26},"某住宅建筑，建筑高度为32m且户门采用乙级防火门，设置敞开楼梯间",{"key":157,"text":261,"correct":26},"某单位地下汽车库，室内地面与室外地坪高差为6m，设置封闭楼梯间","BCDE",{"id":264,"libraryId":5,"type":144,"typeLabel":145,"stem":265,"options":266,"answer":203,"analysis":33},935701,"某高层写字楼主楼地上 20 层，建筑高度 90m，主要使用功能为办公室；裙房地上 5 层，建筑高度 24m，主要使用功能为商场。耐火等级为一级，裙房与高层主体之间设有防火墙，每个营业厅均设有2个安全出口，已按现行有关国家工程技术标准设置了消防设施。对于裙房的防火设计要求，下列表述正确的是（ ）。",[267,269,271,273,275],{"key":20,"text":268,"correct":26},"裙房的每个防火分区最大允许建筑面积不超过 5000 ㎡",{"key":24,"text":270,"correct":22},"裙房可采用防火卷帘划分防火分区，而且不受宽度的限制",{"key":28,"text":272,"correct":26},"该裙房的商场营业厅内任一点至最近的疏散门或安全出口的直线距离不应大于 37.5m；当疏散门不能直通室外地面或疏散楼梯间时，应采用长度不大于 12.5m 的疏散走道通至最近的安全出口",{"key":31,"text":274,"correct":26},"裙房应采用封闭楼梯间或防烟楼梯间",{"key":157,"text":276,"correct":22},"裙房应设消防电梯",{"id":278,"libraryId":5,"type":144,"typeLabel":145,"stem":279,"options":280,"answer":291,"analysis":33},935702,"某一级耐火等级影剧院观众厅，容纳人数为 2500 人，百人宽度指标为 0.65m\u002F百人，在防火检查中，下列做法符合规定的（ ）。",[281,283,285,287,289],{"key":20,"text":282,"correct":26},"该观众厅设了 10 个疏散门，每个疏散门的宽度为 1.8m",{"key":24,"text":284,"correct":22},"观众厅内，横走道之间的座位排数为 22 排",{"key":28,"text":286,"correct":26},"纵走道之间的座位数每排为 22 个",{"key":31,"text":288,"correct":26},"仅一侧有纵走道的座区，每排座位数为 10 个",{"key":157,"text":290,"correct":26},"观众厅内疏散走道的最小净宽为 1m","ACDE",{"id":293,"libraryId":5,"type":144,"typeLabel":145,"stem":294,"options":295,"answer":188,"analysis":33},935703,"下列关于疏散出口检查内容的叙述中，错误的是（ ）。",[296,298,300,302,304],{"key":20,"text":297,"correct":22},"公共建筑内各房间疏散门的数量不少于2个",{"key":24,"text":299,"correct":26},"对于公共建筑内的疏散门和住宅建筑户门，其净宽度不小于1m",{"key":28,"text":301,"correct":22},"疏散门的形式根据建筑类别、使用性质进行确定",{"key":31,"text":303,"correct":26},"每个房间相邻的两个疏散门最近边缘之间的水平距离不小于6m",{"key":157,"text":305,"correct":22},"除甲、乙类生产车间外，人数不超过60人且每道门的平均疏散人数不超过30人的房间，其疏散门的开启方向不限",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":31,"analysis":33},935704,"下列关于建筑防爆采取的措施中，属于减轻性技术措施的是（ ）。",[310,312,314,316],{"key":20,"text":311,"correct":22},"乙炔站采用塑胶板做整体面层，并设置防静电措施",{"key":24,"text":313,"correct":22},"白兰地蒸馏车间采用不发火花的地面",{"key":28,"text":315,"correct":22},"面粉碾磨车间设置地沟，并用盖板盖严",{"key":31,"text":317,"correct":26},"氢气站采用半敞开式钢框架结构",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":20,"analysis":33},935705,"消防机构对某工业区进行消防安全检查，检查结果如下，其中不符合规范要求的是（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":26},"某谷物加工厂房循环使用厂房内的空气，并通过净化处理设备将空气中的含尘浓度降至其爆炸下限的30％",{"key":24,"text":325,"correct":22},"某燃气锅炉房采用防爆型的事故排风机，设定正常通风量的换气次数为8次／h",{"key":28,"text":327,"correct":22},"某多层木器厂房的送风管道分层布置，并在进入生产车间处设置防火阀，该厂房的每层送风管共用一个送风系统",{"key":31,"text":329,"correct":22},"某单层碳化钙厂房的排风机前安装不产生火花的干式除尘器",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":24,"analysis":33},935706,"下列甲醇生产车间内电线、导线的选型及敷设的做法中，不符合现行国家消防技术标准要求的是（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"低压电力线路绝缘导线的额定电压等于工作电压",{"key":24,"text":337,"correct":26},"在1区内的供电线路采用铝芯电线",{"key":28,"text":339,"correct":22},"接线箱内的供配电线路采用无护套的电线",{"key":31,"text":341,"correct":22},"电气线路在较高处敷设",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":28,"analysis":33},935707,"根据现行国家消防技术标准，下列关于除尘器、过滤器等设施设置的说法，错误的是（ ）。",[346,348,350,352],{"key":20,"text":347,"correct":22},"净化有爆炸危险粉尘的干式除尘器应布置在系统的负压段上",{"key":24,"text":349,"correct":22},"净化或输送有爆炸危险粉尘和碎屑的除尘器应设置泄压装置",{"key":28,"text":351,"correct":26},"净化有爆炸危险粉尘的干式除尘器和过滤器宜布置在厂房内的独立房间",{"key":31,"text":353,"correct":22},"对于遇水可能形成爆炸的粉尘，严禁采用湿式除尘器",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":20,"analysis":33},935708,"对地下采用机械通风系统的燃油锅炉房进行防火检查时，应检查风机排风量换气次数是否符合规范要求，其中下列关于燃油锅炉房风机通风量的说法，正确的是（ ）。",[358,360,362,364],{"key":20,"text":359,"correct":26},"正常通风量应按换气次数不少于3次／h确定",{"key":24,"text":361,"correct":22},"事故排风量应按换气次数不少于5次／h确定",{"key":28,"text":363,"correct":22},"事故排风量应按换气次数不少于9次／h确定",{"key":31,"text":365,"correct":22},"正常通风量应按换气次数不少于6次／h确定",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":28,"analysis":33},935709,"对有爆炸危险性的厂房进行检查时，应注意泄压设施的设置是否合理，下列关于泄压设施的说法，不正确的是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"泄压设施宜采用轻质屋面板",{"key":24,"text":373,"correct":22},"泄压门、窗应采用在爆炸时不产生尖锐碎片的安全玻璃",{"key":28,"text":375,"correct":26},"泄压设施应避开人员密集场所、有爆炸危险的部位和主要交通道路",{"key":31,"text":377,"correct":22},"屋顶上的泄压设施应采取防冰雪积聚措施",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},935710,"对爆炸环境电器线路进行检查时，应注意该线路选择是否符合相关环境，下列关于爆炸环境电气线路选择的做法，符合相关规定的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"在爆炸性粉尘环境21区内有剧烈振动区域的回路，采用截面为25mm2铝芯绝缘导线或电缆",{"key":24,"text":385,"correct":22},"低压电力、照明线路采用的绝缘导线和电缆的额定电压小于工作电压",{"key":28,"text":387,"correct":22},"在爆炸危险区域为1区的爆炸性环境采用截面积为2．0mm2的铜芯照明电缆",{"key":31,"text":389,"correct":26},"在爆炸危险区域2区的爆炸性环境采用截面积为18mm2的铝芯电力电缆",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":31,"analysis":33},935711,"某焦化厂煤气压缩厂房采取了防爆技术措施，以下（ ）属于减轻性技术措施。",[394,396,398,400],{"key":20,"text":395,"correct":22},"压缩机尽量保持密闭状态",{"key":24,"text":397,"correct":22},"严禁明火",{"key":28,"text":399,"correct":22},"预防燃气泄漏，设置可燃气体浓度报警装置",{"key":31,"text":401,"correct":26},"采用轻质屋顶增加泄压面积",{"id":403,"libraryId":5,"type":144,"typeLabel":145,"stem":404,"options":405,"answer":291,"analysis":33},935712,"某2层甲醇合成厂房，其中不符合规范要求的有（ ）。",[406,408,410,412,414],{"key":20,"text":407,"correct":26},"厂房采用砖混结构",{"key":24,"text":409,"correct":22},"封闭楼梯间设门斗，门斗上的甲级防火门与楼梯间的疏散门错位布置",{"key":28,"text":411,"correct":26},"厂房内不同方向接地干线有两处与接地体相连",{"key":31,"text":413,"correct":26},"采用光滑的水泥地面",{"key":157,"text":415,"correct":26},"车间设置独立地沟与下水道相通，并设置了水封设施",{"id":417,"libraryId":5,"type":144,"typeLabel":145,"stem":418,"options":419,"answer":159,"analysis":33},935713,"下列有爆炸危险的甲、乙类厂房防爆措施描述正确的是（ ）。",[420,422,424,426,428],{"key":20,"text":421,"correct":26},"有爆炸危险的甲、乙类生产部位,宜布置在单层厂房靠外墙的泄压设施或多层厂房顶层靠外墙的泄压设施附近",{"key":24,"text":423,"correct":26},"有爆炸危险的设备宜避开厂房的梁、柱等主要承重构件布置",{"key":28,"text":425,"correct":22},"门斗的隔墙应为耐火极限不应低于 2.00h 的防火隔墙,门应采用乙级防火门并应与楼梯间的门错位设置",{"key":31,"text":427,"correct":26},"丙类厂房内含有燃烧或爆炸危险粉尘、纤维的空气,在循环使用前应经净化处理,并应使空气中的含尘浓度低于其爆炸下限的 25%",{"key":157,"text":429,"correct":22},"散发较空气重的可燃气体、可燃蒸气的甲类厂房和有粉尘、纤维爆炸危险的乙类厂房,宜采用轻质屋面板作为泄压面积。顶棚应尽量平整、无死角,厂房上部空间应通风良好",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},935714,"在爆炸危险环境电缆的配线技术要求中，爆炸危险区域2区内用于电力的电缆应采用铜芯电缆，其最小截面不应小于（ ）mm2。",[434,436,437,439],{"key":20,"text":435,"correct":22},"1．0",{"key":24,"text":79,"correct":26},{"key":28,"text":438,"correct":22},"2．5",{"key":31,"text":440,"correct":22},"4．0",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":28,"analysis":33},935715,"某建筑地上5层，建筑面积为5800m2，燃气锅炉房采用机械通风，应检查该风机的事故排风量是否不少于（ ）次／h。",[445,447,449,451],{"key":20,"text":446,"correct":22},"6",{"key":24,"text":448,"correct":22},"10",{"key":28,"text":450,"correct":26},"12",{"key":31,"text":452,"correct":22},"15",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":33},935716,"下列内容中，不属于电气防爆检查的是（ ）。",[457,459,461,463],{"key":20,"text":458,"correct":26},"可燃粉尘干式除尘器是否布置在系统的负压段上",{"key":24,"text":460,"correct":22},"导线材质",{"key":28,"text":462,"correct":22},"电气线路敷设方式",{"key":31,"text":464,"correct":22},"带电部件的接地",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":31,"analysis":33},935717,"电气防爆中，线路的敷设主要检查电气线路的敷设方式是否与爆炸环境中气体、蒸气的密度相适应，下面关于电气线路敷设的做法，不符合规范要求的是（ ）。",[469,471,473,475],{"key":20,"text":470,"correct":22},"当爆炸环境中气体、蒸气的密度比空气大时，电气线路敷设可选择埋入地下",{"key":24,"text":472,"correct":22},"当爆炸环境中气体、蒸气的密度比空气小时，电气线路敷设在较低处；当电缆沟敷设时，内部应填沙",{"key":28,"text":474,"correct":22},"铜铝线相接时，采用铜铝过渡接头",{"key":31,"text":476,"correct":26},"敷设电气线路的沟道、钢管或电缆，在穿过不同区域之间的墙或楼板的孔洞时，应采用难燃材料封堵，以防止爆炸性混合物或蒸气沿沟道、电缆管道流动",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":24,"analysis":33},935718,"净化有爆炸危险粉尘的干式除尘器和过滤器宜布置在厂房外的独立建筑内，且建筑外墙与所属厂房的防火间距不小于（ ）m。",[481,482,483,485],{"key":20,"text":446,"correct":22},{"key":24,"text":448,"correct":26},{"key":28,"text":484,"correct":22},"13",{"key":31,"text":452,"correct":22},{"id":487,"libraryId":5,"type":144,"typeLabel":145,"stem":488,"options":489,"answer":500,"analysis":33},935719,"建筑防爆的基本技术措施分为预防性技术措施和减轻性技术措施，下列不属于减轻性技术措施的有（ ）。",[490,492,494,496,498],{"key":20,"text":491,"correct":22},"采取泄压措施",{"key":24,"text":493,"correct":22},"采取合理的建筑布置",{"key":28,"text":495,"correct":26},"排除能引起爆炸的各类可燃物质",{"key":31,"text":497,"correct":22},"采用抗爆性能良好的建筑结构体系",{"key":157,"text":499,"correct":26},"消除或控制能引起爆炸的各种引火源","CE",{"id":502,"libraryId":5,"type":144,"typeLabel":145,"stem":503,"options":504,"answer":291,"analysis":33},935720,"爆炸危险场所的通风、空调系统，因排出有火灾爆炸危险物质没有采取有效措施或由于排风机与电机不配套等引起火灾爆炸的事故时有发生。在对爆炸危险场所进行通风空调系统检查的过程中，符合现行国家工程消防技术标准的做法包括（ ）。",[505,507,509,511,512],{"key":20,"text":506,"correct":26},"甲类厂房内的空气不循环使用",{"key":24,"text":508,"correct":22},"丙类厂房内含有燃烧或爆炸危险粉尘、纤维的空气，在循环使用前应经净化处理，并使空气中的含尘浓度低于其爆炸下限的50％",{"key":28,"text":510,"correct":26},"对空气中含有易燃易爆危险物质的房间，其送、排风系统选用防爆型的通风设备",{"key":31,"text":353,"correct":26},{"key":157,"text":513,"correct":26},"排除有爆炸危险粉尘的排风系统，设置导除静电的接地装置",{"id":515,"libraryId":5,"type":144,"typeLabel":145,"stem":516,"options":517,"answer":528,"analysis":33},935721,"在对容易发生火灾或爆炸的厂房进行防火检查时，应注意检查其供暖系统的设置情况，下列做法中，不符合现行国家消防技术标准要求的有（ ）。",[518,520,522,524,526],{"key":20,"text":519,"correct":26},"在散发可燃纤维的厂房内，散热器表面的平均温度为83.5℃",{"key":24,"text":521,"correct":22},"在散发可燃粉尘的厂房内，输煤廊的散热器表面平均温度为130℃",{"key":28,"text":523,"correct":22},"甲类厂房内的供暖管道和设备的绝热材料采用不燃材料",{"key":31,"text":525,"correct":26},"外壁温度为120℃的供暖管道与可燃构件之间的最近距离为90mm",{"key":157,"text":527,"correct":26},"外壁温度为90℃的供暖管道与可燃构件之间的最近距离为35mm","ADE",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":28,"analysis":33},935722,"在供暖管道的敷设中，当温度大于100℃时，供暖管道与可燃物之间保持的距离不应小于（）mm。",[533,535,536,538],{"key":20,"text":534,"correct":22},"80",{"key":24,"text":32,"correct":22},{"key":28,"text":537,"correct":26},"100",{"key":31,"text":539,"correct":22},"120",{"id":541,"libraryId":5,"type":144,"typeLabel":145,"stem":542,"options":543,"answer":554,"analysis":33},935723,"下列关于建筑防爆采取的防爆措施检查要求的叙述中，正确的是（ ）。",[544,546,548,550,552],{"key":20,"text":545,"correct":22},"有爆炸危险的甲、乙类厂房宜独立设置",{"key":24,"text":547,"correct":22},"有爆炸危险的设备应避开厂房的梁、柱等主要承重构件布置",{"key":28,"text":549,"correct":26},"散发可燃粉尘、纤维的厂房内地面应平整、光滑，并易于清扫",{"key":31,"text":551,"correct":26},"甲、乙、丙类液体仓库设置防止液体流散的设施",{"key":157,"text":553,"correct":26},"遇湿会发生燃烧爆炸的物品仓库应采取防止水浸渍的措施","CDE",{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":31,"analysis":33},935724,"为避免过载、防止短路把电线烧坏或过热形成火源，绝缘电线和电缆的允许载流量不得小于熔断器熔体额定电流的（）倍。",[559,561,563,565],{"key":20,"text":560,"correct":22},"0．75",{"key":24,"text":562,"correct":22},"0．85",{"key":28,"text":564,"correct":22},"1．15",{"key":31,"text":566,"correct":26},"1．25",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":28,"analysis":33},935725,"下列关于有爆炸危险的厂房的总体布局说法中，错误的是（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"有爆炸危险的甲、乙类厂房的总控制室应独立设置",{"key":24,"text":574,"correct":22},"分控制室宜独立设置，当贴邻厂房外墙设置时，应采用耐火极限不低于3．00h的防火隔墙与其他部位分隔",{"key":28,"text":576,"correct":26},"净化有爆炸危险粉尘的干式除尘器和过滤器宜布置在厂房内靠外墙一侧",{"key":31,"text":545,"correct":22},{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":31,"analysis":33},935726,"下列关于有爆炸危险的厂房的平面布置说法中，正确的是（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":22},"有爆炸危险的甲、乙类生产部位，宜布置在单层厂房靠外墙的泄压设施或多层厂房底层靠外墙的泄压设施附近",{"key":24,"text":585,"correct":22},"办公室、休息室不应布置在有爆炸危险的甲、乙类厂房内，如必须贴邻本厂房设置时，建筑耐火等级不得低于二级，并采用耐火极限不低3．00h的防火墙与厂房分隔",{"key":28,"text":587,"correct":22},"排除有燃烧或爆炸危险气体、蒸气和粉尘的排风系统的排风设备应设在地下或半地下室",{"key":31,"text":589,"correct":26},"在爆炸危险区域内的楼梯间、室外楼梯或与相邻区域连通处，设置门斗等防护措施",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":28,"analysis":33},935727,"下列关于爆炸危险区域的检查，说法错误的是（ ）",[594,596,598,600],{"key":20,"text":595,"correct":22},"爆炸危险环境不能选用铝质导线",{"key":24,"text":597,"correct":22},"导线的连接不能采用绕接",{"key":28,"text":599,"correct":26},"安装在已接地的金属结构上的电气设备不须重复接地",{"key":31,"text":601,"correct":22},"接地干线要设置不少于两处与接地体相连",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":24,"analysis":33},935728,"对有燃烧或爆炸危险气体、蒸气和粉尘的厂房进行防火检查，应注意排风系统的设置情况，下列关于该类型厂房排风系统设置的说法，不正确的是（ ）。",[606,608,610,612],{"key":20,"text":607,"correct":22},"排风系统应设置导除静电的接地装置",{"key":24,"text":609,"correct":26},"排风设备应布置厂房首层和地下一层",{"key":28,"text":611,"correct":22},"排风管应采用金属管道",{"key":31,"text":613,"correct":22},"排风管应直接通向室外安全地点，不应暗设",{"id":615,"libraryId":5,"type":144,"typeLabel":145,"stem":616,"options":617,"answer":627,"analysis":33},935729,"某多层金属部件加工厂的滤芯抛光车间内设有地沟。消防机构对该厂房进行检查，下列措施不符合要求的是（ ）。",[618,620,622,624,625],{"key":20,"text":619,"correct":22},"用盖板将车间内的地沟封闭严密",{"key":24,"text":621,"correct":22},"厂房承重结构采用钢框架",{"key":28,"text":623,"correct":26},"抛光部位布置在厂房首层中间区域",{"key":31,"text":413,"correct":26},{"key":157,"text":626,"correct":22},"厂房采用矩形布置","CD",{"id":629,"libraryId":5,"type":144,"typeLabel":145,"stem":630,"options":631,"answer":641,"analysis":33},935730,"下列关于通风、空调设备的防火防爆说法正确的有（ ）。",[632,634,636,638,640],{"key":20,"text":633,"correct":26},"两条输送气体的管道上下布置时，表面温度70℃的管道设在表面温度120℃的管道下方",{"key":24,"text":635,"correct":26},"燃油锅炉房采用机械通风时的正常通风量应按换气次数不少于3次／h",{"key":28,"text":637,"correct":22},"燃气锅炉房采用机械通风时事故排风量应按换气次数不少于6次／h确定",{"key":31,"text":639,"correct":26},"燃气锅炉房应选用防爆型的事故排风机",{"key":157,"text":607,"correct":26},"ABDE",{"id":643,"libraryId":5,"type":144,"typeLabel":145,"stem":644,"options":645,"answer":159,"analysis":33},935731,"下列建筑或部位的供暖设施的设置不符合规定的是（ ）。",[646,648,650,652,654],{"key":20,"text":647,"correct":26},"某面粉生产车间内的散热器表面平均温度 83 摄氏度",{"key":24,"text":649,"correct":26},"在甲酚厂房里使用电热散热器供暖",{"key":28,"text":651,"correct":22},"某生产过程中使用黄磷做原料的厂房采用不循环使用的热风供暖",{"key":31,"text":653,"correct":26},"氢化钠生产车间采用热水管道供暖",{"key":157,"text":655,"correct":22},"某输煤廊的散热器表面最高温度为 130 摄氏度",{"id":657,"libraryId":5,"type":15,"typeLabel":16,"stem":658,"options":659,"answer":24,"analysis":33},935732,"某公共建筑，层高3．8m，地上3层，地下1层，标准层建筑面积500㎡，未设自动灭火系统和中央空调系统，下列关于该公共建筑所选用的室内装修材料，说法正确的是（ ）。",[660,662,664,666],{"key":20,"text":661,"correct":22},"设在地上二层的托儿所的墙面采用彩色阻燃人造板装修",{"key":24,"text":663,"correct":26},"设在地下一层的B级信息机房的墙面采用木纹金属板",{"key":28,"text":665,"correct":22},"设在地下一层的自选超市的地面采用硬PVC地板",{"key":31,"text":667,"correct":22},"设在地下一层的教室的墙面采用钢龙骨纤维石膏板",[669,672,675,678,681,684],{"id":15,"name":670,"category":7,"favorite":671},"领导干部任职前廉政法规知识测试题",92,{"id":673,"name":674,"category":7,"favorite":15},595,"建筑结构与设备",{"id":676,"name":677,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":679,"name":680,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":682,"name":683,"category":7,"favorite":8},534,"BIM工程师",{"id":685,"name":683,"category":7,"favorite":8},535]