[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":658},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,20,50,2974,[13,34,46,58,70,82,94,106,124,139,154,169,184,198,213,227,241,253,265,277,289,299,311,323,335,347,359,371,383,392,404,416,428,442,456,468,483,498,512,527,539,551,563,575,587,599,610,622,634,646],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},935633,1,"单选题","某建筑高度为25m的5层商场，每层建筑面积1200m2，首层至二层为灯饰商场，三层为通讯器材商场（商场人员密度指标二层0．6人／m2，三层0．54人／m2），四层为歌舞厅，五层为商场办公区和餐厅共230人，该建筑一层内的疏散楼梯总净宽应按（ ）部分确定。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","灯饰商场",true,{"key":24,"text":25,"correct":26},"B","通讯器材商场",false,{"key":28,"text":29,"correct":26},"C","歌舞厅",{"key":31,"text":32,"correct":26},"D","商场办公区","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},935634,"对下列建筑进行防火检查，关于疏散门的检查结果，不符含规定的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"多层石棉加工厂房封闭楼梯间的门采用双向弹簧门",{"key":24,"text":41,"correct":26},"高度为23．4m的办公楼采用封闭楼梯间，楼梯间的门为双向弹簧门",{"key":28,"text":43,"correct":22},"某单层农药生产车间，使用人数为5人，设置向内开启的平开门",{"key":31,"text":45,"correct":26},"某多层搪瓷工艺品存储仓库，首层靠墙的外侧门采用推拉门",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},935635,"某多层办公楼，耐火等级二级，未设置自动喷水灭火系统，位于 2 个安全出口之间的房间内的任一点至最近安全出口的直线距离最大为（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":26},"22",{"key":24,"text":53,"correct":26},"40",{"key":28,"text":55,"correct":22},"62",{"key":31,"text":57,"correct":26},"80",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},935636,"对高层医院住院楼进行防火检查，下列关于避难间的说法不符合相关规定的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"避难间应靠近楼梯间，出入口设置明显的指示标志",{"key":24,"text":65,"correct":22},"该住院楼每层均应设置避难间",{"key":28,"text":67,"correct":26},"避难间服务的护理单元最多为2个",{"key":31,"text":69,"correct":26},"避难间应设置直接对外可开启的乙级防火窗",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},935637,"一座容纳人数为2400人的剧场，需要设置的疏散门数量为（ ）个。",[74,76,78,80],{"key":20,"text":75,"correct":26},"8",{"key":24,"text":77,"correct":22},"9",{"key":28,"text":79,"correct":26},"10",{"key":31,"text":81,"correct":26},"11",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},935638,"通向避难走道的各防火分区人数不等时，避难走道的净宽不得小于设计容纳人数最多的一个防火分区通向避难走道各安全出口最小净宽（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"之和",{"key":24,"text":89,"correct":26},"之积",{"key":28,"text":91,"correct":26},"之差",{"key":31,"text":93,"correct":26},"最大值",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},935639,"建筑物内全部设置自动喷淋灭火系统时，安全疏散距离可按规定增加（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"10％",{"key":24,"text":101,"correct":26},"15％",{"key":28,"text":103,"correct":26},"20％",{"key":31,"text":105,"correct":22},"25％",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},935640,2,"多选题","下列民用建筑的安全疏散距离，符合规范要求的是（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":22},"位于高层医院病房楼两个安全出口之间的房间，房间疏散门至最近安全出口的直线距离为30m",{"key":24,"text":115,"correct":22},"位于多层教学楼（耐火等级为二级）两个安全出口之间的房间，房间疏散门至最近安全出口的直线距离为35m",{"key":28,"text":117,"correct":22},"位于多层商店建筑（耐火等级为二级）的两个安全出口之间的房间，房间疏散门至最近安全出口的直线距离为35m",{"key":31,"text":119,"correct":22},"位于高层办公楼袋形走道尽端的房间，房间疏散门至最近安全出口的直线距离为20m",{"key":121,"text":122,"correct":26},"E","位于多层医疗建筑（耐火等级为二级）两个安全出口之间房间疏散门至最近安全出口的直线距离为40m","ABCD",{"id":125,"libraryId":5,"type":108,"typeLabel":109,"stem":126,"options":127,"answer":138,"analysis":33},935641,"下列工业建筑的疏散楼梯应采用封闭楼梯间的有（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":26},"地上2层，建筑高度9m的工业成型硫磺仓库",{"key":24,"text":131,"correct":22},"地上3层，建筑高度15m的焦化厂焦油厂房",{"key":28,"text":133,"correct":22},"地上6层，建筑高度33m的桐油制备厂房",{"key":31,"text":135,"correct":26},"地上7层，建筑高度33m且任一层人数超过10人的厂房",{"key":121,"text":137,"correct":22},"地上6层，建筑高度26m的酚醛泡沫塑料仓库","BCE",{"id":140,"libraryId":5,"type":108,"typeLabel":109,"stem":141,"options":142,"answer":153,"analysis":33},935642,"下列关于疏散走道最小净宽度的说法，符合现行国家技术标准的有（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":26},"高层病房楼双面布房时的疏散走道最小净宽度不应小于1．40m",{"key":24,"text":146,"correct":22},"高层办公建筑单面布房时的疏散走道的最小净宽度不应小于1．30m",{"key":28,"text":148,"correct":22},"厂房内疏散走道的最小净宽度不宜小于1．40m",{"key":31,"text":150,"correct":22},"人防工程内商场单面布房疏散走道的净宽度不应小于1．50m",{"key":121,"text":152,"correct":26},"剧场观众厅内疏散走道的净宽度不应小于1．10m","BCD",{"id":155,"libraryId":5,"type":108,"typeLabel":109,"stem":156,"options":157,"answer":168,"analysis":33},935643,"疏散走道是疏散时人员从房间门至疏散楼梯或外部出口等安全出口的通道。防火检查中，不符合规范要求的有（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":26},"丙类厂房疏散走道的净宽度为1．50 m",{"key":24,"text":161,"correct":22},"高层医疗病房双面布房疏散走道的净宽度为1．40 m",{"key":28,"text":163,"correct":26},"三层住宅疏散走道的净宽度为1．10 m",{"key":31,"text":165,"correct":26},"电影院观众厅边走道的净宽度为0．90 m",{"key":121,"text":167,"correct":22},"高层办公楼单面布房疏散走道的净宽度为1．20 m","BE",{"id":170,"libraryId":5,"type":108,"typeLabel":109,"stem":171,"options":172,"answer":183,"analysis":33},935644,"对某高层病房楼进行防火检查，下列关于该病房楼的检查结果，不符合规范要求的（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"该病房楼每个防火分区设置2部封闭楼梯间，楼梯间采用乙级防火门",{"key":24,"text":176,"correct":22},"该病房楼病房内最远点距房间疏散门的距离为16m",{"key":28,"text":178,"correct":26},"该病房楼病房位于两个楼梯间之间房间疏散门距最近疏散楼梯的距离为22m",{"key":31,"text":180,"correct":26},"该病房楼位于袋形走道尽端病房疏散门距最近楼梯的距离为12m",{"key":121,"text":182,"correct":26},"该病房楼内位于疏散走道两侧的病房，建筑面积50m2，使用人数为8人，设置1樘向内开启的平开门","AB",{"id":185,"libraryId":5,"type":108,"typeLabel":109,"stem":186,"options":187,"answer":168,"analysis":33},935645,"对工业建筑进行消防安全检查时，应注意场所安全出口的设置情况，下列生产场所仅设置一个安全出口，其中符合规范规定的有（ ）。",[188,190,192,194,196],{"key":20,"text":189,"correct":26},"某谷物加工厂的碾磨车间，每层建筑面积210m2，同一时间作业人数3人",{"key":24,"text":191,"correct":22},"某构件制作厂，每层建筑面积350m2，同一时间作业人数30人",{"key":28,"text":193,"correct":26},"某植物油加工厂的浸出车间，每层建筑面积150m2，同一时间作业人数5人",{"key":31,"text":195,"correct":26},"某酚醛泡沫加工厂，每层建筑面积410m2，同一时间作业人数15人",{"key":121,"text":197,"correct":22},"某卷烟厂的切丝车间，每层建筑面积240m2，同一时间作业人数18人",{"id":199,"libraryId":5,"type":108,"typeLabel":109,"stem":200,"options":201,"answer":212,"analysis":33},935646,"对某一类高层教学楼进行防火检查，查阅资料得知，该教学楼耐火等级一级，采用敞开式外廊连接疏散楼梯进行安全疏散，全部设有自动喷水灭火系统，防火分区符合规范要求。下列关于该教学楼安全疏散的说法，不符合规范要求的是（ ）。",[202,204,206,208,210],{"key":20,"text":203,"correct":22},"该教学楼教室内任意一点距疏散门的直线距离不应大于15m",{"key":24,"text":205,"correct":22},"该教学楼可以设置敞开式楼梯间",{"key":28,"text":207,"correct":26},"该教学楼位于袋形走道尽端的教室疏散门距最近安全出口的直线距离不应大于23．75m",{"key":31,"text":209,"correct":22},"该教学楼位于两个楼梯间之间的教室疏散门距最近安全出口的直线距离不应大于37．5m",{"key":121,"text":211,"correct":22},"位于两个安全出口之间的教室的两个疏散门中心线距离为5米","ABDE",{"id":214,"libraryId":5,"type":108,"typeLabel":109,"stem":215,"options":216,"answer":226,"analysis":33},935647,"对民用建筑进行防火检查时，检查人员应注意特殊场所的平面布置和安全疏散是否符合要求，下列场所布置在民用建筑内时，至少设1个独立安全出口和疏散楼梯的是（ ）。",[217,219,220,222,224],{"key":20,"text":218,"correct":22},"礼堂",{"key":24,"text":29,"correct":26},{"key":28,"text":221,"correct":26},"多功能厅",{"key":31,"text":223,"correct":26},"网吧",{"key":121,"text":225,"correct":22},"电影院","AE",{"id":228,"libraryId":5,"type":108,"typeLabel":109,"stem":229,"options":230,"answer":123,"analysis":33},935648,"某高层塔式住宅，建筑高度为 56m,一个单元分散设置两个疏散楼梯确有困难，所以采用的剪刀楼梯间，在防火检查中，下列做法符合规定的有（ ）。",[231,233,235,237,239],{"key":20,"text":232,"correct":22},"从任一户门至最近疏散楼梯间入口的距离不大于 10m",{"key":24,"text":234,"correct":22},"应采用防烟楼梯间",{"key":28,"text":236,"correct":22},"梯段之间应设置耐火极限不低于 1.00h 的防火隔墙",{"key":31,"text":238,"correct":22},"楼梯间的前室不宜共用，共用时，前室的使用面积不应小于 6.0 ㎡",{"key":121,"text":240,"correct":26},"楼梯间的前室或共用前室不宜与消防电梯的前室合用；合用时，合用前室的使用面积不应小于 10.0 ㎡，且短边不应小于 2.4m",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":20,"analysis":33},935649,"消防机构对某小区的多栋住宅楼进行检查，检查结果符合规范要求的是（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"建筑高度为27m，标准层面积为650㎡，任一户门至最近安全出口的距离均不大于15m，设置了一部疏散楼梯",{"key":24,"text":248,"correct":26},"建筑高度为24m，层数为7层，户门采用丙级防火门，设置了敞开楼梯间",{"key":28,"text":250,"correct":26},"建筑高度为34m，户门均采用乙级防火门，设置了敞开楼梯间",{"key":31,"text":252,"correct":26},"建筑高度为55m，任一户门至最近疏散楼梯间人口的距离最大为15m，设置了剪刀楼梯间",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":31,"analysis":33},935650,"某住宅建筑，建筑高度为54m，下列选项中不是该建筑设置一部疏散楼梯所需必要条件的是（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":26},"疏散楼梯能通至屋面",{"key":24,"text":260,"correct":26},"户门采用乙级防火门",{"key":28,"text":262,"correct":26},"单元之间的疏散楼梯能通过屋面相连",{"key":31,"text":264,"correct":22},"疏散楼梯是否与电梯井相邻布置",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":31,"analysis":33},935651,"下列厂房中可以设置一个安全出口的是（ ）。",[269,271,273,275],{"key":20,"text":270,"correct":26},"某单层电解水厂房，建筑面积为150㎡，同一时间作业人数4人",{"key":24,"text":272,"correct":26},"某4层焦化厂焦油厂房，每层建筑面积为400㎡，同一时间作业人数25人",{"key":28,"text":274,"correct":26},"某2层焦化厂精萘厂房，每层建筑面积为100㎡，同一时间作业人数15人",{"key":31,"text":276,"correct":22},"某地下氟利昂厂房，每层建筑面积为45㎡，同一时间作业人数为9人",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":28,"analysis":33},935652,"某体育馆观众厅容纳人数2500人，最少需要设置（ ）个疏散门。",[281,283,285,287],{"key":20,"text":282,"correct":26},"2",{"key":24,"text":284,"correct":26},"7",{"key":28,"text":286,"correct":22},"4",{"key":31,"text":288,"correct":26},"6",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":33},935653,"某剧场观众厅设计容纳人数为3600人，则最少需要设置（ ）个疏散门。",[293,294,295,297],{"key":20,"text":77,"correct":26},{"key":24,"text":288,"correct":26},{"key":28,"text":296,"correct":22},"12",{"key":31,"text":298,"correct":26},"14",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":28,"analysis":33},935654,"某展览厅设置在耐火等级为二级的建筑内，设有两个安全出口，建筑内全部设有自动喷水灭火系统。下列说法中，不符合现行国家消防技术标准要求的是（ ）。",[303,305,307,309],{"key":20,"text":304,"correct":26},"展览厅内室内任一点至最近的疏散门的距离最大为37．5m",{"key":24,"text":306,"correct":26},"当展览厅的疏散门不能直通疏散楼梯间时，可通过最长不超过12．5m的疏散走道通至楼梯间",{"key":28,"text":308,"correct":22},"当展览厅的疏散门不能直通疏散楼梯间时，可通过疏散走道通至楼梯间，其中展览厅内的疏散距离可为40m，疏散走道的长度可为10m",{"key":31,"text":310,"correct":26},"当展览厅的疏散门不能直通疏散楼梯间时，可通过疏散走道通至楼梯间，展览厅内任一点至疏散楼梯间的距离不能超过50m",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":33},935655,"某办公建筑，地上3层，耐火等级为三级，标准层建筑面积为1400㎡，该建筑按国家最低标准设置了消防设施，下列做法符合规范要求的是（ ）。",[315,317,319,321],{"key":20,"text":316,"correct":26},"每层划分为1个防火分区",{"key":24,"text":318,"correct":22},"其中位于2安全出口之间的一个办公室最大使用面积为50㎡，设置了1个疏散门",{"key":28,"text":320,"correct":26},"位于二层袋型走道尽端、面积400㎡的多功能厅，设置了1个1．4m的外开门",{"key":31,"text":322,"correct":26},"地上二、三层每层人数12人，设置1部疏散楼梯",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":20,"analysis":33},935656,"疏散走道是疏散时人员从房间门通行至疏散楼梯或者外部出口等安全出口的通道，通常作为火灾疏散时的第一安全通道。对某高层医疗建筑的疏散走道进行防火检查，下列设置不符合规范要求的是（ ）。",[327,329,331,333],{"key":20,"text":328,"correct":22},"单面布房的疏散走道净宽度为1．2 m，双面布房的疏散走道净宽度为1．4 m",{"key":24,"text":330,"correct":26},"疏散走道内未设置阶梯、门槛、门垛",{"key":28,"text":332,"correct":26},"疏散走道两侧隔墙的耐火极限为1．00 h",{"key":31,"text":334,"correct":26},"疏散走道地面为B1级材料装修",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":28,"analysis":33},935657,"某大型地下商场，建筑面积为40000 m2，采用兼作人员疏散的下沉式广场进行防火分隔。下列关于下沉式广场的做法中，正确的是（ ）。",[339,341,343,345],{"key":20,"text":340,"correct":26},"用于疏散的净面积为125 m2",{"key":24,"text":342,"correct":26},"设置防风雨棚，四周开口高度为0．5 m",{"key":28,"text":344,"correct":22},"有一部满足疏散宽度要求并直通地面的疏散楼梯",{"key":31,"text":346,"correct":26},"不同区域通向下沉式广场的开口之间的最大水平距离为10 m",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":24,"analysis":33},935658,"某购物中心，地下2层，建筑面积65000 m2，设置南、北2个开敞的下沉式广场，下列做法中正确的是（ ）。",[351,353,355,357],{"key":20,"text":352,"correct":26},"分割后的购物中心不同区域通向北下沉式广场开口最近边缘的水平距离宜为12 m",{"key":24,"text":354,"correct":22},"南、北下沉式广场各设置1部直通室外地面并满足疏散宽度指标的疏散通道",{"key":28,"text":356,"correct":26},"南下沉式广场上方设防雨棚，其开口面积为室外敞开空间地面面积的20％",{"key":31,"text":358,"correct":26},"下沉式广场设置商业零售点，但不影响人员疏散",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":28,"analysis":33},935659,"在对下列仓库的安全出口进行检查时，不符合规范要求的是（ ）。",[363,365,367,369],{"key":20,"text":364,"correct":26},"防火分区面积为100m2的地上锂电池仓库设置了一个安全出口",{"key":24,"text":366,"correct":26},"占地面积为400m2的地上白酒仓库设置了两个安全出口",{"key":28,"text":368,"correct":22},"地下建筑面积为400m2的陶瓷制品仓库设置了一个安全出口",{"key":31,"text":370,"correct":26},"占地面积为200m2的地上镁粉仓库设置了一个安全出口",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":28,"analysis":33},935660,"某地下商场的总建筑面积为50000m2，采用一个下沉式广场将商场分隔为 A、 B、C三个独立的区域。下列关于该下沉式广场设置的做法中，错误的是（ ）。",[375,377,379,381],{"key":20,"text":376,"correct":26},"直通地面的疏散楼梯一共设2部",{"key":24,"text":378,"correct":26},"A区域通向下沉式广场的开口与B区域通向下沉式广场的开口之间的水平距离为16m",{"key":28,"text":380,"correct":22},"下沉式广场的室外开敞空间用于疏散的净面积为144m2",{"key":31,"text":382,"correct":26},"防风雨棚四周开口部位均匀布置，开口的面积为室外开敞空间地面面积的30％",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":24,"analysis":33},935661,"设置剪刀楼梯是当相邻两个安全出口的间距难以满足不应小于5 m时的变通措施，对底部数层为商场和步行购物街、上部为塔楼的建筑进行防火检查时，检查人员应注意核对设置剪刀楼梯的合理性，任一门户或疏散门至最近疏散楼梯间入口的距离不应大于（ ）m。",[387,389,390,391],{"key":20,"text":388,"correct":26},"5",{"key":24,"text":79,"correct":22},{"key":28,"text":284,"correct":26},{"key":31,"text":296,"correct":26},{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":28,"analysis":33},935662,"疏散出口设置数量的检查，是建筑防火检查的一项重要内容。下列关于疏散出口设置的说法中，错误的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":26},"位于养老院一层，建筑面积为40m2且处于两个安全出口之间的房间可以设置1个疏散出口",{"key":24,"text":399,"correct":26},"某卡拉ＯＫ歌厅内，建筑面积为50m2且停留人数在15以下的练歌房可以设置1个疏散出口",{"key":28,"text":401,"correct":22},"某二层煤油灌装间，每层建筑面积为250m2，同时作业人数9人，可以设置1个疏散出口",{"key":31,"text":403,"correct":26},"某钢材冷轧厂的3层厂房，每层建筑面积400m2，同时作业人数10人，可以设置1个疏散出口",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":28,"analysis":33},935663,"某市中心医院的病房楼共11层，根据规定该病房楼在二层及以上各层靠近楼梯间的部位设置了避难间，每个避难间服务的护理单元为2个。公安消防机构在防火检查时，抽查了其中间的净面积，结果分别是：1号避难间净面积为50.6m2；2号避难间净面积为47.3m2；3号避难间净面积为47.9m2；4号避难间净面积为48.2m2。根据上述结果，下列说法中正确的是（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":26},"只有1号避难间的净面积符合要求",{"key":24,"text":411,"correct":26},"只有1号和4号避难间的净面积符合要求",{"key":28,"text":413,"correct":22},"只有2号避难间的净面积不符合要求",{"key":31,"text":415,"correct":26},"2号和3号避难间的净面积都不符合要求",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":28,"analysis":33},935664,"避难走道是指设置防烟设施且两侧采用耐火极限不低于（ ）h的防火隔墙分隔，用于人员安全通行至室外的走道。",[420,422,424,426],{"key":20,"text":421,"correct":26},"2.00",{"key":24,"text":423,"correct":26},"2.50",{"key":28,"text":425,"correct":22},"3.00",{"key":31,"text":427,"correct":26},"4.00",{"id":429,"libraryId":5,"type":108,"typeLabel":109,"stem":430,"options":431,"answer":212,"analysis":33},935665,"某多层公共建筑，地上5层，地下1层，地上部分为商场，地下部分为KTV，KTV建筑总面积为200㎡，消防机构对该KTV进行消防安全检查，下列检查结果中符合规范要求的是（ ）。",[432,434,436,438,440],{"key":20,"text":433,"correct":22},"该KTV内建筑面积不大于50㎡且经常停留人数不超过15人的房间，设置了一个疏散门",{"key":24,"text":435,"correct":22},"该KTV内最大一个房间的面积为150㎡",{"key":28,"text":437,"correct":26},"该KTV设置一个安全出口",{"key":31,"text":439,"correct":22},"该KTV厅、室之间应采用耐火极限不低于2．00h的防火隔墙和1．50h不燃性楼板进行分隔，墙上设置的门采用乙级防火门",{"key":121,"text":441,"correct":22},"该KTV室内地面与室外出入口地坪的高差为10m",{"id":443,"libraryId":5,"type":108,"typeLabel":109,"stem":444,"options":445,"answer":212,"analysis":33},935666,"关于高层病房楼和手术部的避难间，说法不正确的是（ ）。",[446,448,450,452,454],{"key":20,"text":447,"correct":22},"高层病房楼应在每层设置避难间",{"key":24,"text":449,"correct":22},"避难间服务的护理单元不应超过2个，其净面积应按2个护理单元不小于25．0㎡确定",{"key":28,"text":451,"correct":26},"避难间兼作其他用途时，不得减少可供避难的净面积",{"key":31,"text":453,"correct":22},"避难间应设置消火栓、消防专线电话和消防应急广播",{"key":121,"text":455,"correct":22},"应靠近楼梯间，可利用防烟楼梯间和消防电梯合用前室做避难间，并应采用耐火极限不低于2．00h的防火隔墙和甲级防火门与其他部位分隔",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":24,"analysis":33},935667,"消防检测机构对某工业区进行检测评估，下列检测结果中，不符合规范要求的是（ ）。",[460,462,464,466],{"key":20,"text":461,"correct":26},"甲类厂房，每层建筑面积为100 m2，且同一时间的生产人数3人，设置一个安全出口",{"key":24,"text":463,"correct":22},"厂房的地下室不同防火分区之间可用开在墙上的甲级防火门作为第二安全出口",{"key":28,"text":465,"correct":26},"仓库的占地面积为250 m2设置一个安全出口",{"key":31,"text":467,"correct":26},"地下仓库的建筑面积100 m2设置一个安全出口",{"id":469,"libraryId":5,"type":108,"typeLabel":109,"stem":470,"options":471,"answer":482,"analysis":33},935668,"关于安全出口的说法，以下正确的是（）。",[472,474,476,478,480],{"key":20,"text":473,"correct":22},"安全出口是指供人员安全疏散用的楼梯间、室外楼梯的出入口或直通室内外安全区域的出口，保证在火灾时能够迅速安全地疏散人员和抢救物资，减少人员伤亡，降低火灾损失",{"key":24,"text":475,"correct":26},"安全出口的数量与安全出口总宽度、安全疏散距离没有直接关系",{"key":28,"text":477,"correct":26},"公共建筑内每个防火分区或一个防火分区的每个楼层，安全出口不少于3个",{"key":31,"text":479,"correct":22},"住宅建筑安全出口数量与建筑单元每层的建筑面积和户门到安全出口的距离有关，一般要求住宅单元每层的安全出口不少于2个",{"key":121,"text":481,"correct":22},"厂房每个防火分区或一个防火分区的每个楼层的安全出口不少于2个","ADE",{"id":484,"libraryId":5,"type":108,"typeLabel":109,"stem":485,"options":486,"answer":497,"analysis":33},935669,"封闭楼梯间的检查要求包括（）。",[487,489,491,493,495],{"key":20,"text":488,"correct":22},"楼梯间靠外墙布置，并能直接天然采光和自然通风",{"key":24,"text":490,"correct":22},"首层如将走道和门厅等包括在楼梯间内形成扩大的封闭楼梯间时，需采用乙级防火门等措施与其他走道和房间隔开",{"key":28,"text":492,"correct":22},"除楼梯间的门之外，楼梯间的内墙上不开设其他门窗洞口",{"key":31,"text":494,"correct":26},"高层建筑、人员密集的公共建筑、人员密集的多层丙类厂房、甲乙类厂房楼梯间的门为甲级防火门，并向疏散方向开启",{"key":121,"text":496,"correct":26},"楼梯间墙体采用耐火极限不低于3．00h的不燃体","ABC",{"id":499,"libraryId":5,"type":108,"typeLabel":109,"stem":500,"options":501,"answer":226,"analysis":33},935670,"室外楼梯的检查要求包括（）。",[502,504,506,508,510],{"key":20,"text":503,"correct":22},"室外楼梯和每层出口处平台，采用不燃烧材料制作，平台的耐火极限不低于1．00h",{"key":24,"text":505,"correct":26},"在楼梯周围2．0m内的墙面上不开设其他门窗洞口，疏散门为甲级防火门，且不正对楼梯段设置",{"key":28,"text":507,"correct":26},"楼梯段耐火极限不低于0．25h，楼梯的最小净宽不小于0．9m，倾斜角度不大于45°，栏杆扶手的高度不小于1．2m",{"key":31,"text":509,"correct":26},"公共建筑的疏散楼梯两段之间的水平净距不小于25cm",{"key":121,"text":511,"correct":22},"疏散楼梯不采用螺旋楼梯和扇形踏步，如踏步上下两级所形成的平面角不超过10°，每级离扶手25cm处的踏步深度超过22cm时可作疏散楼梯使用",{"id":513,"libraryId":5,"type":108,"typeLabel":109,"stem":514,"options":515,"answer":526,"analysis":33},935671,"下沉式广场等室外开敞空间能有效防止烟气积聚，足够宽度的室外空间，可以有效阻止火灾的蔓延。某大型地下商场采用下沉式广场分隔成多个相互独立的区域，在商场投入使用前，公安机关消防机构对该商场进行检查，下列检查结果符合规范要求的是（ ）。",[516,518,520,522,524],{"key":20,"text":517,"correct":22},"设置1部直通地面的疏散楼梯",{"key":24,"text":519,"correct":22},"室外开敞空间用于疏散的净面积为180 m2",{"key":28,"text":521,"correct":22},"防风雨棚开口面积为该空间地面面积的30％",{"key":31,"text":523,"correct":26},"防风雨棚开口高度为0．8m",{"key":121,"text":525,"correct":22},"不同区域通向下沉式广场开口最近边缘之间的水平距离为15m","ABCE",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":24,"analysis":33},935672,"下列关于疏散走道的净宽度，说法错误的是（ ）。",[531,533,535,537],{"key":20,"text":532,"correct":26},"造纸厂的疏散走道净宽度为1．50m",{"key":24,"text":534,"correct":22},"某建筑高度为20m的六层小区住宅楼疏散走道的净宽度为1．00m",{"key":28,"text":536,"correct":26},"体育馆观众厅疏散走道的净宽度为1．00m",{"key":31,"text":538,"correct":26},"某建筑高度为18m三层商场疏散走道的净宽度为1．20m",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":24,"analysis":33},935673,"下列民用建筑中，可以设置一个安全出口的情况是（）。",[543,545,547,549],{"key":20,"text":544,"correct":26},"一个老年人照料中心，采用二级耐火等级，一共二层，每层15人。",{"key":24,"text":546,"correct":22},"某歌舞娱乐场所，设置在某多层建筑的首层，面积200平米，人数48人。",{"key":28,"text":548,"correct":26},"某独立的三级耐火等级的办公楼，地上三层，每层190平米，二层三层人数之和为40人。",{"key":31,"text":550,"correct":26},"某耐火等级为一级的幼儿园，一共两层，总建面120平米，额定人数25人。",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":24,"analysis":33},935674,"某7层商业综合体建筑，层高5m，某裙房与综合体之间采用防火墙分隔，裙房地上3层，地下2层，建筑总面积30000㎡，耐火等级为一级，则商业综合体第三层的百人疏散宽度指标应为（ ）m／百人。",[555,557,559,561],{"key":20,"text":556,"correct":26},"0．65",{"key":24,"text":558,"correct":22},"1．00",{"key":28,"text":560,"correct":26},"0．75",{"key":31,"text":562,"correct":26},"0．85",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":20,"analysis":33},935675,"关于该下沉式广场的说法，错误是（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":22},"直通地面的疏散楼梯不应少于 1 部，防雨棚不应封闭，排烟面积不小于地面的 60%，设置百叶窗时百叶窗有效排烟面积按照 25%计算。",{"key":24,"text":570,"correct":26},"A 区域通向下沉式广场的开口与 B 区域通向下沉式广场的开口之间的水平距离为 16m",{"key":28,"text":572,"correct":26},"下沉式广场的室外开敞空间用于疏散的净面积不应小于 169 ㎡",{"key":31,"text":574,"correct":26},"防火分区利用下沉式广场进行疏散时，下沉式广场疏散楼梯的总净宽度不应小于任一防火分区通向室外开敞空间的设计疏散总净宽度",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":31,"analysis":33},935676,"某医院病房楼，建筑高度36m，每层建筑面积1600㎡，二层及以上设有避难间，消防服务机构受医院委托对该病房进行防火检查，下列结果中，不符合现行国家技术标准的是（ ）。",[579,581,583,585],{"key":20,"text":580,"correct":26},"病房楼避难间设有独立的机械防烟设施，外窗采用乙级防火窗",{"key":24,"text":582,"correct":26},"手术室采用耐火极限为2．50h的防火隔墙和1．50h的楼板与病房楼其他部位分隔，墙上连通处开设乙级防火门",{"key":28,"text":584,"correct":26},"重症监护室采用耐火极限为3．00h的防火隔墙和1．5h的楼板与病房楼做分隔，连通处开设甲级防火门",{"key":31,"text":586,"correct":22},"避难间采用耐火极限为2．00h的防火隔墙和乙级防火门与病房楼分隔",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":28,"analysis":33},935677,"下列场所可设置一个疏散门的是（ ）。",[591,593,595,597],{"key":20,"text":592,"correct":26},"某建筑面积为200㎡的电影院观众厅，观众厅内任一点至房间疏散门的距离为15m，疏散门的净宽度为1．4m",{"key":24,"text":594,"correct":26},"某办公室位于袋形走道尽端，建筑面积为120㎡，房间疏散门的净宽度为0．9m",{"key":28,"text":596,"correct":22},"某幼儿园教室位于袋形走道的两侧，建筑面积为50㎡，房间疏散门的净宽度为0．9m",{"key":31,"text":598,"correct":26},"某医院的病房位于袋形走道的两侧，建筑面积为100㎡",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":31,"analysis":33},935678,"某办公建筑地上12层，建筑高度38m，总建筑面积9000㎡，耐火等级为二级，楼内采用送回风管道的集中空气调节系统，并按现行有关国家消防技术标准设置了消防设施。则建筑内位于袋形走道两侧或尽端的办公室疏散门至最近楼梯间的直线距离不应大于（ ）m。",[603,605,606,608],{"key":20,"text":604,"correct":26},"27．5",{"key":24,"text":51,"correct":26},{"key":28,"text":607,"correct":26},"20",{"key":31,"text":609,"correct":22},"25",{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":28,"analysis":33},935679,"关于的幼儿园儿童用房的说法，符合规范要求的有（）。",[614,616,618,620],{"key":20,"text":615,"correct":26},"设置在15层高层建筑三层的幼儿园未设置独立的安全出口和疏散楼梯",{"key":24,"text":617,"correct":26},"设置在三级耐火等级建筑的三层",{"key":28,"text":619,"correct":22},"设置在二级的多层建筑三层的幼儿园设置了独立的安全出口和疏散楼梯",{"key":31,"text":621,"correct":26},"幼儿园不应设置在四级耐火等级建筑内",{"id":623,"libraryId":5,"type":15,"typeLabel":16,"stem":624,"options":625,"answer":20,"analysis":33},935680,"一类高层公共建筑和建筑高度大于32m的二类高层公共建筑应采用（ ）。",[626,628,630,632],{"key":20,"text":627,"correct":22},"防烟楼梯间",{"key":24,"text":629,"correct":26},"封闭楼梯间",{"key":28,"text":631,"correct":26},"敞开楼梯间",{"key":31,"text":633,"correct":26},"室外楼梯",{"id":635,"libraryId":5,"type":15,"typeLabel":16,"stem":636,"options":637,"answer":24,"analysis":33},935681,"某商场地上5层，地下2层，建筑高度为21 m，总建筑面积为9000 m2。每层建筑面积为1 500 m2，地下二层商场室内地面与室外出入口地坪高差为11 m。该商场地下部分消防设计不符合规范要求的是（ ）。",[638,640,642,644],{"key":20,"text":639,"correct":26},"未设置消防电梯",{"key":24,"text":641,"correct":22},"设置了封闭楼梯间",{"key":28,"text":643,"correct":26},"设置了自动喷水灭火系统",{"key":31,"text":645,"correct":26},"设置了防烟排烟设施",{"id":647,"libraryId":5,"type":15,"typeLabel":16,"stem":648,"options":649,"answer":28,"analysis":33},935682,"对某建筑高度为55 m的高层宾馆进行检查时，不符合规范要求的设置是（ ）。",[650,652,654,656],{"key":20,"text":651,"correct":26},"宾馆双面布房疏散走道的最小净宽度为1．4m",{"key":24,"text":653,"correct":26},"宾馆单面布房疏散走道的最小净宽度为1．3 m",{"key":28,"text":655,"correct":22},"宾馆设置的剪刀楼梯的合用前室和消防电梯前室合用，合用前室的建筑面积为10㎡",{"key":31,"text":657,"correct":26},"宾馆的顶棚采用燃烧性能等级为A级的装修材料",[659,662,665,668,671,674],{"id":15,"name":660,"category":7,"favorite":661},"领导干部任职前廉政法规知识测试题",92,{"id":663,"name":664,"category":7,"favorite":15},595,"建筑结构与设备",{"id":666,"name":667,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":669,"name":670,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":672,"name":673,"category":7,"favorite":8},534,"BIM工程师",{"id":675,"name":673,"category":7,"favorite":8},535]