[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":653},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,2,50,2974,[13,34,46,58,70,82,94,106,123,135,147,159,171,183,195,207,218,230,242,254,266,281,293,305,317,329,343,358,372,386,398,410,422,434,449,464,479,494,506,518,530,542,554,569,581,593,605,617,629,641],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},934623,1,"单选题","（2020年真题）某宾馆为消防安全重点单位，该宾馆的下列做法中，不符合《机关、团体、企业、事业单位消防安全管理规定》（公安部令第61号）要求的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","每月组织—次防火检查",false,{"key":24,"text":25,"correct":22},"B","每2h开展—次防火巡查",{"key":27,"text":28,"correct":29},"C","每年组织员工开展—次消防演练",true,{"key":31,"text":32,"correct":22},"D","每半年组织员工开展—次消防安全培训","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},934625,"（2020年真题）某博物馆拟对本单位职工开展消防安全教育培训。根据《社会消防安全教育培训规定》（公安部令第109号），下列培训内容中，应作为培训重点的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"全国消防安全面临的形式",{"key":24,"text":41,"correct":29},"本单位的防火灭火措施",{"key":27,"text":43,"correct":22},"本行业典型火灾案例",{"key":31,"text":45,"correct":22},"文保系统的消防工作有关文件",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},934627,"（2020年真题）某商场为消防安全重点单位。对该商场开展消防安全评估，检查单位的消防档案。根据《机关、团体、企业、事业单位消防安全管理规定》（公安部令第61号）不属于消防安全基本情况档案内容的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"商场最新更换的疏散指示标志的合格证明材料。",{"key":24,"text":53,"correct":29},"商场组织的灭火和应急疏散预案演练记录。",{"key":27,"text":55,"correct":22},"商场向当地消消防救援机构报告备案的消防安全管理员情况。",{"key":31,"text":57,"correct":22},"商场微型消防站，装备配备表。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},934629,"(2016年真题) 对工业建筑进行防火检查时，应注意检查工业建筑的火灾危险性，耐火等级和建筑面积，在检查的下列工业建筑中，可以采用三级耐火等级的是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"建筑面积为1500㎡的金属冶炼车间",{"key":24,"text":65,"correct":22},"建筑面积为350㎡的氨压缩机房",{"key":27,"text":67,"correct":22},"蒸发量为7t\u002Fh的燃煤锅炉房",{"key":31,"text":69,"correct":29},"独立建造的建筑面积为280㎡的单层制氧车间",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},934632,"(2015年真题) 南昌、衡阳和哈尔滨曾先后发生3起建筑火灾坍塌事故，建筑分别在火灾发生后115min、196min、537min时坍塌。坍塌建筑的底部或底部数层均为钢筋混凝土框架结构、上部均为砖混结构。实事上，下列建筑结构中，耐火性能相对较低的是（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"砖混结构",{"key":24,"text":77,"correct":22},"钢筋混凝结构",{"key":27,"text":79,"correct":29},"钢结构",{"key":31,"text":81,"correct":22},"钢筋混凝土排架结构",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},934634,"(2016年真题) 关于储存物品的火灾危险性，下列说法不正确的是（）",[86,88,90,92],{"key":20,"text":87,"correct":22},"同一座仓库同时存放不同物品时，存储过程中采用分区存储",{"key":24,"text":89,"correct":22},"同一座仓库放了汽油、机械零件、包装用的木箱，将仓库划分为甲类储存物品仓库",{"key":27,"text":91,"correct":29},"采用木箱包装的戊类物品，木箱总量大于物品本身重量的1\u002F4，将仓库的火灾危险性划分为丁类",{"key":31,"text":93,"correct":22},"储存电子元件的仓库，采用纸盒与泡沫塑料包装电子元件，包装材料的体积大于电子元件的体积1\u002F2，仓库的火灾危险性划分为丙类",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},934636,"(2017年真题) 某多层丙类仓库，采用预应力钢筋混凝土楼板，耐火极限0.85h；钢结构屋顶承重构件采用防火涂料保护，耐火极限为0.90h;吊顶采用轻钢龙骨石膏板，耐火极限0.15h;外墙采用难燃性墙体，耐火极限为0.50h;仓库内设有自动喷水灭火系统，该仓库的下列结构中，不满足二级耐火等级建筑要求的是()。",[98,100,102,104],{"key":20,"text":99,"correct":22},"预应力混凝土楼板",{"key":24,"text":101,"correct":29},"钢结构屋顶承重构件",{"key":27,"text":103,"correct":22},"轻钢龙骨石膏板吊项",{"key":31,"text":105,"correct":22},"难燃性外墙",{"id":107,"libraryId":5,"type":9,"typeLabel":108,"stem":109,"options":110,"answer":122,"analysis":33},934638,"多选题","(2017年真题) 对某动物饲料加工厂的谷物碾磨车间进行防火检查，查阅资料得知，该车间耐火等级为一级，防火分区划分符合规范要求。 该车间的下列做法中，符合现行国家消防技术标准要求的有（??）",[111,113,115,117,119],{"key":20,"text":112,"correct":22},"配电站设于厂房内的一层，采用防火墙和耐火极限1.50h的楼板与其他区域分隔，墙上的门为甲级防火门",{"key":24,"text":114,"correct":22},"位于厂房三层的运行调度监控室采用防火墙和耐火极限1.50h的楼板与其他部分分隔，且设有独立使用的防烟楼梯间",{"key":27,"text":116,"correct":22},"车间办公室帖邻厂房外墙设置，采用耐火极限4.00h的防火墙与厂房分隔，并设有独立的安全出口",{"key":31,"text":118,"correct":29},"设置在一层的产品临时存放仓库单独划分防火分区",{"key":120,"text":121,"correct":29},"E","位于二层的饲料添加剂仓库（丙类）采用防火墙和耐火极限为1.5h的楼板与其他部分分隔， 墙上的门为甲级防火门","DE",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":24,"analysis":33},934641,"(2017年真题)在对某化工厂的电解食盐车间进行防火检查时，查阅资料得知，该车间耐火等级为一级。该车间的下列做法中，不符合现行国家消防技术标准的是（??）",[127,129,131,133],{"key":20,"text":128,"correct":22},"丙类中间仓库设置在该车间的地上二层",{"key":24,"text":130,"correct":29},"该车间生产线贯通地下一层到地上三层",{"key":27,"text":132,"correct":22},"丙类中间仓库与其他部位的分隔墙为耐火极限3.00h的防火墙",{"key":31,"text":134,"correct":22},"丙类中间仓库无独立的安全出口",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":27,"analysis":33},934645,"(2018年真题)某单层建筑釆用经阻燃处理的木柱承重，承重墙体釆用砖墙。根据现行国家标准《建筑设计防火规范》（GB50016），该建筑的耐火等级为( )",[139,141,143,145],{"key":20,"text":140,"correct":22},"一级",{"key":24,"text":142,"correct":22},"二级",{"key":27,"text":144,"correct":29},"四级",{"key":31,"text":146,"correct":22},"三级",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":20,"analysis":33},934647,"(2016年真题)对厂房、仓库进行防火检查时，应检查厂房、仓库的平面布置情况。某家具厂的下列做法中，不符合规范要求的是（??）",[151,153,155,157],{"key":20,"text":152,"correct":29},"厂房内设置员工宿舍，采用防火墙和甲级防火门与生产车间分隔，并设置独立出口",{"key":24,"text":154,"correct":22},"厂房内设置办公室，并采用耐火极限为2.5h的防火墙与生产车间分隔",{"key":27,"text":156,"correct":22},"厂房内设置办公室，联通生产车间的门采用乙级防火门",{"key":31,"text":158,"correct":22},"靠外墙设置存放油漆的中间仓库，采用防火墙与生产区分隔，且设置直通室外的出口",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":31,"analysis":33},934649,"(2018年真题)某单位新建员工集体宿舍，室内地面标高±0.000m，室外地面标高-0.0450m，地上7层，局部8层，至七层为标准层，每层建筑面积 1200m2，七层屋面面层标高21.000m。8 层为设备用房，建筑面积 290㎡，八层屋面面层标高25.000m。 根据现行国家标准《建筑设计防火规范》(GB50016)，该建筑类别为( )。",[163,165,167,169],{"key":20,"text":164,"correct":22},"二类高层住宅建筑",{"key":24,"text":166,"correct":22},"二类高层公共建筑",{"key":27,"text":168,"correct":22},"多层住宅建筑",{"key":31,"text":170,"correct":29},"多层公共建筑",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":27,"analysis":33},934651,"（2020年真题）某住宅建筑，屋面建筑面积为1100m2。屋顶设有局部突出屋面的水箱间、风机房、楼梯间等辅助用房，建筑面积共计140。建筑室外地坪面标高为-0.450m，建筑屋面面层标高为26.650m，女儿墙顶部标高为27.850m，辅助用房顶部标高为29.00Om。住宅底部设有室内净高为2m的自行车车库和储藏室。对该建筑进行防火检查时应按（ ）的标准要求进行。",[175,177,179,181],{"key":20,"text":176,"correct":22},"—类高层建筑",{"key":24,"text":178,"correct":22},"二类高层住宅",{"key":27,"text":180,"correct":29},"多层住宅",{"key":31,"text":182,"correct":22},"三类高层住宅",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":27,"analysis":33},934653,"（2020年真题）对某工业园区进行防火检查时，发现下列仓库厂房的耐火等级均为三级，其中不符合现行国家标准要求的是（ ）。",[187,189,191,193],{"key":20,"text":188,"correct":22},"建筑面积为1000平方米的单层沥青加工厂房",{"key":24,"text":190,"correct":22},"总蒸发量为4t\u002Fh的燃煤锅炉房",{"key":27,"text":192,"correct":29},"建筑面积为500平方米的多层漂白粉仓库",{"key":31,"text":194,"correct":22},"建筑面积为300平方米的单层，独立式樟脑提炼厂房",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":31,"analysis":33},934655,"（2020年真题）某仓库内存放有煤油1m3.闪点65℃的柴油5m。某消防技术服务机构对该仓库进行消防安全评估。根据现行国家标准，该仓库的火灾危险性应判定为（。",[199,201,203,205],{"key":20,"text":200,"correct":22},"甲类",{"key":24,"text":202,"correct":22},"丙类",{"key":27,"text":204,"correct":22},"丁类",{"key":31,"text":206,"correct":29},"乙类",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":20,"analysis":33},934657,"(2016年真题) 对厂房仓库进行防火检查时，应检查厂房仓库的平面布局情况。某家具厂的下列做法中，不符合规范要求的是（）。",[211,212,214,216],{"key":20,"text":152,"correct":29},{"key":24,"text":213,"correct":22},"厂房内设置办公室，并采用耐火极限为2.5h的防火隔墙与生产车间分隔",{"key":27,"text":215,"correct":22},"厂房内设置办公室，连通生产车间的门采用乙级防火门",{"key":31,"text":217,"correct":22},"靠外墙设置存放油漆的中间仓库，采用防火墙与生产区域分隔，且设置直通室外的出口",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":31,"analysis":33},934659,"(2016年真题) 消防车登高操作场地是消防灭火救援的重要设施，下列关于消防车登高操作场地设置的说法中，错误的是（）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"高层建筑应至少沿一个长边或周边长度的1\u002F4且不小于一个长边长度的底边连续布置消防车登高操作场地",{"key":24,"text":225,"correct":22},"消防车登高操作场地靠建筑外墙一侧的边缘距离建筑外墙不应大于10m",{"key":27,"text":227,"correct":22},"消防车登高操作场地的坡度不宜大于3%",{"key":31,"text":229,"correct":29},"高层建筑的消防车登高面不应布置裙房",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":31,"analysis":33},934661,"(2015年真题) 下列关于消防电梯的说法中，正确的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"建筑高度大于24m的住宅应设置消防电梯",{"key":24,"text":237,"correct":22},"消防电梯轿厢的内部装修应采用难燃材料",{"key":27,"text":239,"correct":22},"消防电梯应专用于消防灭火救援",{"key":31,"text":241,"correct":29},"满足消防电梯要求的客梯或货梯可以兼做消防电梯",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":27,"analysis":33},934663,"(2015年真题) 某丙类火灾危险性厂房，地上4层，耐火等级为二级，建筑高度22.5m，建筑面积25000㎡，在第四层靠外墙部位设置成品喷漆工段，建筑面积120㎡。下列做法中，符合规定的是（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":22},"将厂房一层原150㎡的办公区改建为3间员工宿舍，并采用防火墙与其他部位分隔",{"key":24,"text":249,"correct":22},"在厂房二层新增4间办公室，该办公区采用耐火极限2.5h的防火隔墙1.0h的楼板与其他部分分隔，并通过相邻车间的封闭楼梯疏散",{"key":27,"text":251,"correct":29},"丙类润滑油中间储蓄罐容量为4.7m3，设置在厂房一层的单独房间内，该房间采用防火墙和耐火极限不低于1.5h的楼板与其他部位分隔",{"key":31,"text":253,"correct":22},"在厂房四层设置中间仓库，储存喷漆工段一昼夜生产所需的油漆，该仓库采用耐火极限为2.5h的防火隔墙和1.5h的楼板与其他部位分隔",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":20,"analysis":33},934665,"(2015年真题) 某石油化工企业的厂区设置办公区、动力设备用房、消防站、甲类和乙类液体储蓄罐、液体烃储存罐、装卸设施和桶装油品堆场。下列关于工厂总平面布置的做法中，正确的是（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":29},"全厂性的高架火炬设置在生产区全年最小频率风向的上风侧",{"key":24,"text":261,"correct":22},"采用架空电力线路进出厂区的总变电所布置在厂区中心",{"key":27,"text":263,"correct":22},"消防站位于生产区全年最小频率风向的上风侧",{"key":31,"text":265,"correct":22},"散发可燃气体的工艺装置和罐组布置在人员集中场所全年最小频率风向的下风侧",{"id":267,"libraryId":5,"type":9,"typeLabel":108,"stem":268,"options":269,"answer":280,"analysis":33},934667,"(2017年真题) 对某一类高层宾馆进行防火检查，查阅资料得知，该宾馆每层划分为2个防火分区，符合规范要求，下列检查结果中，不符合现行国家消防技术标准的有（）。",[270,272,274,276,278],{"key":20,"text":271,"correct":29},"消防电梯前室的建筑面积为6.0㎡,与防烟楼梯间合用前室的建筑面积为10㎡",{"key":24,"text":273,"correct":29},"兼做客梯用的消防电梯，其前室门采用耐火极限满足耐火完整性和耐火隔热性判定的防火卷帘",{"key":27,"text":275,"correct":22},"设有3台消防电梯，一个防火分区有2台，另一个防火分区有1台",{"key":31,"text":277,"correct":22},"消防电梯能够停靠每个楼层",{"key":120,"text":279,"correct":22},"消防电梯从首层到顶层的运行时间为59S","AB",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":33},934669,"(2017年真题) 在对某高层多功能组合建筑进行防火检查时，查阅资料得知，该建筑耐火等级为一级，十层至顶层为普通办公用房，九层及以下为培训、娱乐、商业等功能，防火分区划分符合规范要求。该建筑的下列做法中，不符合现行国家消防技术标准的是()。",[285,287,289,291],{"key":20,"text":286,"correct":22},"消防水泵房设为地下二层，其室内地面与室外出入口地坪高差为10m",{"key":24,"text":288,"correct":29},"主楼六层设有儿童早教培训班，设有独立的安全出口",{"key":27,"text":290,"correct":22},"常压燃气锅炉房布置在主楼层面上，使用管道天然气做燃料，距离通向屋面的安全出口10m",{"key":31,"text":292,"correct":22},"裙楼五层设歌舞厅，各厅室的建筑面积均小于200㎡，与其他区域公用安全出口",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":20,"analysis":33},934670,"(2017年真题) 在对某一类高层商业综合体进行检查时，查阅资料得知，该楼地上共6层，每层划分为12个防火分区，符合规范要求。该综合体外部的下列消防救援设施设置做法中，不符合现行国家消防技术标准要求的是()。",[297,299,301,303],{"key":20,"text":298,"correct":29},"由于该综合体外立面无窗，故在二至六层北侧外墙上每个防火分区分别设置2个消防救援窗口",{"key":24,"text":300,"correct":22},"仅在该楼的北侧沿长边连续布置宽度12m的消防车登高操作场地",{"key":27,"text":302,"correct":22},"消防车登高操作场地内侧与该商业综合体外墙之间的最近距离为9m",{"key":31,"text":304,"correct":22},"建筑物与消防车登高操作场地相对应范围内有6个直通室内防烟楼梯间的入口",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":31,"analysis":33},934671,"(2015年真题) 某机加工企业需在生产车间内设置中间仓库储存硝酸。下列设置要求中，符合规范规定的是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":22},"中间仓库靠外墙布置，采用防火墙及耐火极限不低于1.0h的楼板与其他部位分隔，硝酸储量不超过1昼夜用量",{"key":24,"text":312,"correct":22},"中间仓库靠外墙布置，采用耐火极限不低于2.5h的防火墙和1.5h的楼板与其他部位分隔，硝酸储量不超过1昼夜用量",{"key":27,"text":314,"correct":22},"中间仓库靠外墙布置，采用耐火极限不低于2.0h的防火墙和1.5h的楼板与生产部位分隔，硝酸储量不超过1昼夜用量",{"key":31,"text":316,"correct":29},"中间仓库靠外墙布置，采用防火墙及耐火极限不低于1.5h的不燃性楼板与其他部位分隔，硝酸储量不超过1昼夜用量",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":31,"analysis":33},934672,"(2016年真题) 对民用建筑的附属用房进行防火检查，下列检查结果中，不符合现行国家消防技术标准的是（）。",[321,323,325,327],{"key":20,"text":322,"correct":22},"住宅建筑地下车库的疏散楼梯与地上部分共用楼梯间，并按规范采取分隔措施",{"key":24,"text":324,"correct":22},"将常压燃油锅炉房设置在高层建筑地下二层",{"key":27,"text":326,"correct":22},"将柴油发电机房布置在商业建筑的地下二层",{"key":31,"text":328,"correct":29},"将油浸变压器室设置在剧场建筑的地下二层",{"id":330,"libraryId":5,"type":9,"typeLabel":108,"stem":331,"options":332,"answer":280,"analysis":33},934673,"(2015年真题) 某办公楼，设置一部消防电梯和2部防烟楼梯间，消防电梯单独设置。在检测消防电梯及其前室时，下列做法中，符合规定的有（ ）",[333,335,337,339,341],{"key":20,"text":334,"correct":29},"消防电梯从首层到顶层的运行时间为60s",{"key":24,"text":336,"correct":29},"在首层的消防电梯入口设置供消防队员专用的操作按钮",{"key":27,"text":338,"correct":22},"在消防电梯前室的消防入口处采用防火卷帘分隔",{"key":31,"text":340,"correct":22},"地下层为无人员经常停留的汽车库，消防电梯不停靠",{"key":120,"text":342,"correct":22},"消防电梯前室的建筑面积为5㎡",{"id":344,"libraryId":5,"type":9,"typeLabel":108,"stem":345,"options":346,"answer":357,"analysis":33},934674,"(2016年真题) 某丙类厂房建筑高度为45m，对其消防救援窗口进行防火检查。下列消防救援窗口设置的做法中，符合规范要求的有（）。",[347,349,351,353,355],{"key":20,"text":348,"correct":29},"消防救援窗口采取易碎安全玻璃，并在外侧设置明显标志",{"key":24,"text":350,"correct":22},"每个防火分区设置1个消防救援窗口",{"key":27,"text":352,"correct":22},"消防救援窗口设置在3层以上楼层",{"key":31,"text":354,"correct":29},"消防救援窗口的净高和净宽约为1.20m",{"key":120,"text":356,"correct":29},"消防救援窗口的下沿距地面室内高度为1.2m","ADE",{"id":359,"libraryId":5,"type":9,"typeLabel":108,"stem":360,"options":361,"answer":357,"analysis":33},934675,"(2015年真题) 对民用建筑实施防火检查时，检查人员应注意查看特殊功能场所设置情况。不应设置在地下或半地下,且不应设置在四层及四层以上的用房有()。",[362,364,366,368,370],{"key":20,"text":363,"correct":29},"托儿所.幼儿园的儿童用房",{"key":24,"text":365,"correct":22},"医院的住院部分",{"key":27,"text":367,"correct":22},"疗养院的住院部分",{"key":31,"text":369,"correct":29},"儿童游乐厅等儿童活动场所",{"key":120,"text":371,"correct":29},"老年人活动场所",{"id":373,"libraryId":5,"type":9,"typeLabel":108,"stem":374,"options":375,"answer":122,"analysis":33},934676,"(2016年真题) 对某地下一层A防工程进行消防安全检查，下列检查结果中，不符台现行国家消防技术标准要求的有（）。",[376,378,380,382,384],{"key":20,"text":377,"correct":22},"设置了排烟机房，且采用防火墙和常闭甲级防火门与其他场所隔开",{"key":24,"text":379,"correct":22},"设置了个建筑面积为200m2的电游戏厅，并采取了相应的防火分隔措施",{"key":27,"text":381,"correct":22},"设置了一个建筑面积为2000m2的超市.并采取了相应的防火分隔措施",{"key":31,"text":383,"correct":29},"设置了一十建筑面积为200m2的幼儿早数中心，并采取了相应的防火丹隔措施",{"key":120,"text":385,"correct":29},"设置了一个建筑面积为150m2的餐厅，其操怍间采用液化石油气燃料",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":27,"analysis":33},934677,"（2019年真题）某养老院，共5层，建筑高度为22m，每层建筑面积为1000㎡，对该养老院的下列防火检查结果中，符合现行国家标准要求的是（）。",[390,392,394,396],{"key":20,"text":391,"correct":22},"地下一层设有1间建筑面积为200㎡的健身房，有35人使用",{"key":24,"text":393,"correct":22},"地上四层设有1间有40个就餐座位的餐厅",{"key":27,"text":395,"correct":29},"地上三层设有1间建筑面积为300㎡的诊疗室",{"key":31,"text":397,"correct":22},"疏散门采用火灾时能自动开启的电动推拉门",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":33},934679,"（2019年真题）对某厂区进行防火检查，消防电梯设置的下列防火检查结果中，不符合现行国家标准要求的是（）",[402,404,406,408],{"key":20,"text":403,"correct":22},"设置在冷库穿堂区的消防电梯未设置前室",{"key":24,"text":405,"correct":29},"高层厂房兼做消防电梯的货梯在设备层不停靠",{"key":27,"text":407,"correct":22},"消防电梯前室的短边尺寸为2.40m",{"key":31,"text":409,"correct":22},"消防电梯井与相邻电梯井之间采用耐火极限为2.00h的防火隔墙分隔",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},934681,"（2019年真题）某松节油生产厂房专用的10kV变电站贴邻厂房设置。该厂房的下列防火防爆做法中，不符合现行国家标准要求的是（）。",[414,416,418,420],{"key":20,"text":415,"correct":22},"生产厂房贴邻变电站的墙体为防火墙",{"key":24,"text":417,"correct":22},"贴邻的防火墙设置了一扇不可开启的甲级防火窗",{"key":27,"text":419,"correct":22},"厂房的所有电器均采用防爆电器",{"key":31,"text":421,"correct":29},"厂房与变电站连通开口处设置了甲级防火门",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":31,"analysis":33},934683,"（2019年真题）某二级耐火等级的单层白酒联合厂房,设有自动喷水灭火系统和火灾自动报警系统,对该厂房进行防火检查时发现： 1.灌装车间与勾兑车间采用耐火极限为3.00h的隔墙分隔。 2.容量为20立方米的成品酒灌装罐设置在灌装车间内靠外墙部位。 3.最大防火分区建筑面积为7000平方米。 4.最大疏散距离为30米。 上述防火检查结果中,符合现行国家标准要求的共有（）",[426,428,430,432],{"key":20,"text":427,"correct":22},"1项",{"key":24,"text":429,"correct":22},"2项",{"key":27,"text":431,"correct":22},"4项",{"key":31,"text":433,"correct":29},"3项",{"id":435,"libraryId":5,"type":9,"typeLabel":108,"stem":436,"options":437,"answer":448,"analysis":33},934685,"（2019年真题）某6层商场，建筑高度为30m，东西长200m，南北宽80，每层划分为4个防火分区，对该商场的下列防火检查结果中，不符合现行国家标准要求的有（）",[438,440,442,444,446],{"key":20,"text":439,"correct":22},"供消防救援人员进入的窗口净高度为1.0m",{"key":24,"text":441,"correct":29},"在第六层南面外墙整层设置室外电子显示屏",{"key":27,"text":443,"correct":29},"供消防救援人员进入的窗口净宽度为0.5m",{"key":31,"text":445,"correct":29},"供消防救援人员进入的窗口在室内对应部位设置可破拆的广告灯箱",{"key":120,"text":447,"correct":22},"供消防救援人员进入的窗口下沿距室内地面1.0m","BCD",{"id":450,"libraryId":5,"type":9,"typeLabel":108,"stem":451,"options":452,"answer":463,"analysis":33},934688,"（2019年真题）对某车用乙醇生产厂房进行防火检查，下列防火检查结果中，符合现行国家标准《建筑设计防火规范》(GB50016)要求的有（）",[453,455,457,459,461],{"key":20,"text":454,"correct":29},"该厂房与二级耐火等级的单层氨压缩机房的间距为12m",{"key":24,"text":456,"correct":22},"该厂房与饲料加工厂房贴邻，相邻较高一面外墙为防火墙",{"key":27,"text":458,"correct":22},"该厂房与厂区内建筑高26m的办公楼间距为30m",{"key":31,"text":460,"correct":29},"该厂房建筑高度27m的造纸车间间距为13m",{"key":120,"text":462,"correct":22},"该厂房与厂外铁路线中心线的间距为20m","AD",{"id":465,"libraryId":5,"type":9,"typeLabel":108,"stem":466,"options":467,"answer":478,"analysis":33},934690,"（2019年真题）某二级耐火等级建筑，地上12层，地下2层，建筑总高度为3000m，一至二层为商业服务网点，三至十二层为住宅。对该建筑的下列防火检査结果中，符合现行国家标准《建筑设计防火规范》(GB50016)要求的有（）",[468,470,472,474,476],{"key":20,"text":469,"correct":29},"商业服务网点采用敞开楼梯间",{"key":24,"text":471,"correct":29},"商业服务网点内疏散楼梯净宽为1.1m",{"key":27,"text":473,"correct":22},"该楼梯间內的地下部分与地上部分在首层采用耐火极限为1.00h的隔墙分隔",{"key":31,"text":475,"correct":29},"商业服务网点内的最大疏散距离为22m",{"key":120,"text":477,"correct":22},"住宅的疏散楼梯采用封闭楼梯间","ABD",{"id":480,"libraryId":5,"type":9,"typeLabel":108,"stem":481,"options":482,"answer":493,"analysis":33},934692,"(2016年真题)南方某工业厂区，占地面积为180hm2，长方形地块，其宽度为1000m，消防水泵房为独立建筑且设置在地块的中心位置，消防给水系统采用室内外合用的临时高压系统，系统设计流量和压力分别为120L\u002Fs，1.0MPa，厂区消防控制室至消防水泵房行走距离为800m。验收时，下列检测结果中，符合现行国家消防技术标准的有（??）。",[483,485,487,489,491],{"key":20,"text":484,"correct":22},"消防水泵房地面与室外地坪相差50mm高差，没有挡水设施",{"key":24,"text":486,"correct":22},"室外最不利点消火栓到消防泵房的行走距离为1350m",{"key":27,"text":488,"correct":29},"稳压泵设计流量3L\u002Fs",{"key":31,"text":490,"correct":22},"消防水泵五用一备",{"key":120,"text":492,"correct":29},"消防水泵房不设置值班室","CE",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":27,"analysis":33},934694,"(2017年真题)某城市全年最小频率风向为东北风。 该市的一个大型化工企业内设有甲醛储罐区均为地上固定顶储罐， 储罐直径20m、 容量5000m3， 防火堤内不包括储罐占地的净面积5000m2,下列防火检查结果中，不符合现行国家消防技术标准的是（??）",[498,500,502,504],{"key":20,"text":499,"correct":22},"锅炉房位于甲醒储罐区南侧， 两者之间的防火间距为55m",{"key":24,"text":501,"correct":22},"甲醛储罐之间的间距为12.5m",{"key":27,"text":503,"correct":29},"甲醛储罐区防火堤高度为1.1m",{"key":31,"text":505,"correct":22},"罐区周围的环形消防车道有3%的坡度， 且上空有架空管道， 距车道净空高度为5m",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":24,"analysis":33},934696,"(2018年真题)对某建筑高度为 120m 的酒店进行消防验收检测，消防车道，消防车登高操作场地，消防救援窗口的实测结果中，不符合现行国家标准要求的是( )。",[510,512,514,516],{"key":20,"text":511,"correct":22},"建筑设置环形消防车道，车道净宽为 4.0m",{"key":24,"text":513,"correct":29},"消防车登高操作场地的长度和宽度分别为 15m 和 12m",{"key":27,"text":515,"correct":22},"消防车道的转弯半径为 15m",{"key":31,"text":517,"correct":22},"消防救援窗口的净高和净宽均为 1.1m，下沿距室内地面 1.1m",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":20,"analysis":33},934698,"(2018年真题)某大型冷库在建工程，施工现场需要进行防火作业，根据现行国家标淮《建设工程施工现场消防安全技术规范》(GB 50720)，氧气瓶与乙块瓶的工作间距，气瓶与明火作业点的最小距离分别不应小于( )。",[522,524,526,528],{"key":20,"text":523,"correct":29},"5m，10m",{"key":24,"text":525,"correct":22},"5m，8m",{"key":27,"text":527,"correct":22},"4m，9m",{"key":31,"text":529,"correct":22},"4m，10m",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":27,"analysis":33},934700,"(2018年真题)某耐火等级为一级的单层赛璐珞棉仓库，占地面积 360㎡，未设置防火分隔和自动消防设施，对该仓库提出的下列整改措施中，正确的是（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":22},"将该仓库作为 1 个防火分区，增设自动喷水灭火系统和火灾自动报警系统",{"key":24,"text":537,"correct":22},"将该仓库用耐火极限为 4.00h 的防火墙平均划分为 4 个防火分区，并增设火灾自动报警系统",{"key":27,"text":539,"correct":29},"将该仓库用耐火极限为 4.00h 的防火墙平均划分为 3 个防火分区，并增设自动喷水灭火系统",{"key":31,"text":541,"correct":22},"将该仓库用耐火极限为 4.00h 的防火墙平均划分为 6 个防火分区",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":27,"analysis":33},934702,"(2018年真题)某一级加油站与 LPG 加气合建站，站房建筑面积为 150 ㎡，该站的平面布置不符合现行国家标准《汽车加油加气站设计与施工规范》（GB50156）的是（ ）",[546,548,550,552],{"key":20,"text":547,"correct":22},"站房布置在加油加气作业区内",{"key":24,"text":549,"correct":22},"加油加气作业区外设有经营性餐饮、汽车服务等设施",{"key":27,"text":551,"correct":29},"电动汽车充电设施布置在加油加气作业区内",{"key":31,"text":553,"correct":22},"站区设置了高度 2.2m 的不燃烧实体围墙",{"id":555,"libraryId":5,"type":9,"typeLabel":108,"stem":556,"options":557,"answer":568,"analysis":33},934704,"（2020年真题）某老年人照料设施，建筑面积为1500m2，设置在耐火等级为二级的多层公共建筑的首层和二层，下列防火检查结果中，符合现行国家标准要求的有（ ）。",[558,560,562,564,566],{"key":20,"text":559,"correct":29},"吊顶采用耐火极限0.25h的不燃材料",{"key":24,"text":561,"correct":22},"房间隔墙采用耐火极限0.2h的不燃材料",{"key":27,"text":563,"correct":29},"与建筑其他功能区域采用耐火极限2.00h的防火隔墙和1.00h的楼板分隔",{"key":31,"text":565,"correct":29},"位于走道尽端的房间疏散门至最近安全出口的距离为20m",{"key":120,"text":567,"correct":29},"首层的老年人餐厅建筑面积为300m2，疏散门外1.40m范围内设置坡道","ACDE",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},934707,"（2020年真题）某地上老年人照料设施,总建筑面积为3600㎡,3层设置与款楼梯直接连通的开敞式外廊,下列防火检查结果中,不符合现行国家标准要求的是（ ）",[573,575,577,579],{"key":20,"text":574,"correct":22},"3层未设置避难间",{"key":24,"text":576,"correct":29},"2层设置的避难间内可供避难的净面积为10m2",{"key":27,"text":578,"correct":22},"避难间采用甲级防火门和耐火极限为2.00h的防火隔墙与其他部位分隔",{"key":31,"text":580,"correct":22},"避难间外窗采用以及防火窗",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":31,"analysis":33},934709,"（2020年真题）某建筑有4家使用单位:地上一层设有1个超市,建筑面积为800m2;地上二层设有1个游艺场和1个KTV,其中游艺场建筑面积为680㎡,KTV建筑面积525㎡;地上三至六层为宾馆,客房总数100间。上述4家单位中,不需要向当地消防救援机构申报消防安全重点单位备案的是（ ）。",[585,587,589,591],{"key":20,"text":586,"correct":22},"游艺场",{"key":24,"text":588,"correct":22},"KTV",{"key":27,"text":590,"correct":22},"宾馆",{"key":31,"text":592,"correct":29},"超市",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":20,"analysis":33},934711,"（2020年真题）某消防技术服务机构对某环氧丙烷产生厂房进行了防火防爆检查。下列检查结果中，不符合现行国家标准要求的是（ ）.",[597,599,601,603],{"key":20,"text":598,"correct":29},"厂房内设置的总控制室采用耐火极限为4.0Oh的防爆墙和耐火极限为2.5Oh的不燃烧体楼板与其他部位完全分隔，并设置独立的安全出口",{"key":24,"text":600,"correct":22},"楼梯间设置的门斗隔墙耐火极限为2.50h",{"key":27,"text":602,"correct":22},"贴邻厂房设置的休息室采用耐火极限为4.00h的防爆墙与厂房分隔，且设有独立的安全出口",{"key":31,"text":604,"correct":22},"厂房的承重结构采用钢筋混凝土排架结构",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":31,"analysis":33},934713,"（2020年真题）某市开展加油加气站防火专项检查。根据现行国家标注，下列加油加气站不应设置在城市中心区的是（ ）.",[609,611,613,615],{"key":20,"text":610,"correct":22},"加油站∶共设3个单罐容积30m3的汽油罐和3个单罐容积30m3的柴油罐",{"key":24,"text":612,"correct":22},"加气站︰共设2个单罐容积30m3的LNG储罐",{"key":27,"text":614,"correct":22},"合建站∶共设2单罐容积30m3的汽油罐和1个单罐容积30m3的LPG储罐",{"key":31,"text":616,"correct":29},"加气站:共设2个单罐容积30m3的LPG储罐",{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":24,"analysis":33},934715,"（2020年真题）某酒店建筑高度为96.5m，地上28层，每层建筑面积为3200m2，地下1层，功能为汽车库，建筑面积为2500m2。建筑设有自动灭火系统。下列检查结果中，不符合现行国家标准要求的是（ ）。",[621,623,625,627],{"key":20,"text":622,"correct":22},"地下汽车库设置1部消防电梯，并设独立的消防电梯前室",{"key":24,"text":624,"correct":29},"地上楼层设置1部消防电梯，且与防烟楼梯间合用前室",{"key":27,"text":626,"correct":22},"消防电梯机房与相邻电梯机房隔墙的耐火极限为2.00h，",{"key":31,"text":628,"correct":22},"消防电梯从最低层至顶层的运行时间为55s",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":20,"analysis":33},934717,"(2017年真题) 某建筑高度为33m，耐火等级为一级，地上10层，地下2层。一到二层为商业部分，三层至十层为办公区域，地下第二层为汽车库，建筑内全部设置了自动喷水灭火系统，该建筑的办公区域和汽车库防火分区的最大允许面积分别为（）。",[633,635,637,639],{"key":20,"text":634,"correct":29},"3000㎡，4000㎡",{"key":24,"text":636,"correct":22},"4000㎡，4000㎡",{"key":27,"text":638,"correct":22},"4000㎡，5000㎡",{"key":31,"text":640,"correct":22},"5000㎡，5000㎡",{"id":642,"libraryId":5,"type":15,"typeLabel":16,"stem":643,"options":644,"answer":31,"analysis":33},934719,"(2015年真题) 某百货大楼，地上4层，局部6层，建筑高度36m，建筑面积28700㎡，下列做法中，错误的是（）。",[645,647,649,651],{"key":20,"text":646,"correct":22},"防火墙上的防火门采用向疏散方向开启的平开门，并在关闭后能从任何一侧手动开启",{"key":24,"text":648,"correct":22},"办公区走道上的甲级防火门采用常开防火门，在火灾情况下能自行关闭并反馈信号",{"key":27,"text":650,"correct":22},"变形缝附近的防火门设置在六层建筑一侧",{"key":31,"text":652,"correct":29},"因消防电梯前室的门洞尺寸较大，防火门安装和使用不便，采用防火卷帘代替",[654,657,660,663,666,669],{"id":15,"name":655,"category":7,"favorite":656},"领导干部任职前廉政法规知识测试题",92,{"id":658,"name":659,"category":7,"favorite":15},595,"建筑结构与设备",{"id":661,"name":662,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":664,"name":665,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":667,"name":668,"category":7,"favorite":8},534,"BIM工程师",{"id":670,"name":668,"category":7,"favorite":8},535]