[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-19":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":667},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,19,50,2974,[13,38,53,68,83,98,113,128,143,157,171,183,195,209,221,233,245,257,269,281,293,305,317,329,340,352,364,376,385,397,409,421,433,448,463,478,493,508,522,536,548,560,572,584,596,607,619,631,643,655],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},935583,2,"多选题","下列关于商店营业厅防火分区的说法中，错误的是（ ）。",[19,23,26,29,33],{"key":20,"text":21,"correct":22},"A","某建筑高度为26m的综合楼，地上一、二层为商店营业厅，按要求设置了自动喷水灭火系统、火灾自动报警系统，则商店营业厅防火分区的最大允许建筑面积为4000㎡",true,{"key":24,"text":25,"correct":22},"B","某7层综合楼，层高4m、首层设置商店营业厅，并按要求设置了自动喷水灭火系统、火灾自动报警系统，装修材料均为不燃材料，则该商店营业厅防火分区的最大允许建筑面积为10000㎡",{"key":27,"text":28,"correct":22},"C","某商店建筑，地上2层，地下1层，耐火等级为二级，按要求设置了自动喷水灭火系统、火灾自动报警系统，装修材料均为不燃材料，则地上一层的防火分区的最大允许建筑面积为10000㎡",{"key":30,"text":31,"correct":32},"D","某多层建筑，耐火等级为二级，仅首层设商店营业厅，并按要求设置了自动喷水灭火系统及火灾自动报警系统，采用不燃、难燃材料装修则防火分区的最大允许建筑面积为10000㎡",false,{"key":34,"text":35,"correct":22},"E","某多层商店建筑，耐火等级为三级，地上2层，并按要求设置了自动喷水灭火系统、火灾自动报警系统，装修材料均为不燃材料，则地上一层防火分区的最大允许建筑面积为10000㎡","ABCE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},935584,"某商场地上5层，建筑高度28m，建筑内设置一个连通上、下各层且带有回廊的中庭，该中庭首层建筑面积10000㎡，二至五层建筑面积均为8000㎡。消防机构对该商场进行防火检查，下列检查结果不正确的有（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":32},"与中庭相连通的门、窗，采用火灾时自行关闭的甲级防火门、窗",{"key":24,"text":45,"correct":32},"中庭回廊设置自动喷水灭火系统和火灾自动报警系统",{"key":27,"text":47,"correct":22},"中庭设置防烟设施",{"key":30,"text":49,"correct":22},"中庭内布置有可燃物",{"key":34,"text":51,"correct":22},"中庭与周围连通的空间采用耐火极限为1．00h的防火卷帘进行防火分隔","CDE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},935585,"下列场所在防火分隔时不能使用防火卷帘等效替代的是（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":32},"甲、乙类生产部位",{"key":24,"text":60,"correct":32},"厂房内有明火和高温的部位",{"key":27,"text":62,"correct":32},"建筑内使用丙类液体的部位",{"key":30,"text":64,"correct":22},"乙醇厂房内划分防火分区的防火墙",{"key":34,"text":66,"correct":22},"儿童游乐厅与商场其它区域分隔的防火隔墙","DE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},935586,"下列关于防火卷帘设置的说法中正确的是（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":22},"设置在中庭的防火卷帘，其耐火极限不应低于3．00h",{"key":24,"text":75,"correct":32},"除中庭外，当防火分隔部位的宽度为72m时，防火卷帘的宽度为22m",{"key":27,"text":77,"correct":32},"除中庭外，当防火分隔部位的宽度为36m时，防火卷帘的宽度为13m",{"key":30,"text":79,"correct":22},"除中庭外，当防火分隔部位的宽度为24m时，防火卷帘的宽度为10m",{"key":34,"text":81,"correct":22},"需在火灾时自动降落的防火卷帘，应具有信号反馈功能","ADE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},935587,"下列关于防火墙的说法中，正确的是（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"当建筑外墙为可燃性的墙体时，防火墙应凸出墙体外表面0．4m以上",{"key":24,"text":90,"correct":22},"当建筑外墙为不燃性墙体时，防火墙可不凸出墙的外表面",{"key":27,"text":92,"correct":32},"当防火墙设置在转角处时，内转角两侧墙上的门、窗、洞口之间最近边缘的水平距离不应小于2．0m，采取设置乙级防火窗等防止火灾水平蔓延的措施时，该距离可不限",{"key":30,"text":94,"correct":32},"防火墙上应设置不可开启或火灾时能自动关闭的甲级防火门、窗",{"key":34,"text":96,"correct":32},"防火墙内可设置排气道，但应采用防火封堵材料将墙与管道之间的空隙紧密填实","AB",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":112,"analysis":37},935588,"下列关于防火门的说法错误的是（ ）。",[102,104,106,108,110],{"key":20,"text":103,"correct":32},"设置在建筑内经常有人通行处的防火门宜采用常开防火门，常开防火门应能在火灾时自行关闭，并应具有信号反馈的功能",{"key":24,"text":105,"correct":22},"防火门设置在建筑变形缝附近，当门扇开启跨越变形缝时，应开向楼层较多的一侧",{"key":27,"text":107,"correct":32},"双扇防火门应具有按顺序自行关闭的功能",{"key":30,"text":109,"correct":32},"除另有规定外，防火门应能在其内外两侧手动开启",{"key":34,"text":111,"correct":22},"防火门关闭后应具备排烟功能","BE",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":127,"analysis":37},935589,"通风空气调节系统的风管在下列部位应设置公称动作温度为70℃的防火阀的有（ ）。",[117,119,121,123,125],{"key":20,"text":118,"correct":22},"穿越空调机房的隔墙和楼板处",{"key":24,"text":120,"correct":32},"穿越防火分隔的变形缝的一侧",{"key":27,"text":122,"correct":32},"每个防火分区独立设置的空调系统的竖管与水平支管交接处的水平支管上",{"key":30,"text":124,"correct":22},"穿越危险性大和重要房间的隔墙和楼板处",{"key":34,"text":126,"correct":32},"公共建筑内厨房的排油烟管道与竖向排风管连接的支管处","AD",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":142,"analysis":37},935590,"某大型商业综合体，地上六层，地下两层，建筑高度 27m，每层建筑面积 10000 ㎡,在首层至三层设有室内步行街，两侧商铺通过有顶步行街进行安全疏散时，下列做法正确的是（ ）。",[132,134,136,138,140],{"key":20,"text":133,"correct":22},"步行街的长度不宜大于 300m",{"key":24,"text":135,"correct":22},"步行街两侧建筑的商铺之间应设置耐火极限不低于 2.00h 的防火隔墙，每间商铺的建筑面积不宜大于300 ㎡",{"key":27,"text":137,"correct":22},"步行街的顶棚材料应采用不燃或难燃材料，其承重结构的耐火极限不应低于 1.00h。步行街内不应布置可燃物",{"key":30,"text":139,"correct":22},"步行街的顶棚下檐距地面的高度不应小于 6.0m，顶棚应设置自然排烟设施并宜采用常开式的排烟口，且自然排烟口的有效面积不应小于步行街地面面积的 25%",{"key":34,"text":141,"correct":32},"步行街内任一点到达最近室外安全地点的步行距离不应大于 60m，步行街两侧建筑二层及以上各层商铺的疏散门至该层最近疏散楼梯口或其他安全出口的直线距离不应大于 30m","ABCD",{"id":144,"libraryId":5,"type":145,"typeLabel":146,"stem":147,"options":148,"answer":30,"analysis":37},935591,1,"单选题","一厂房，室内净空高度8m，且具有自然对流条件，下列该厂房防烟分区的长边设置不符合要求的是（）。",[149,151,153,155],{"key":20,"text":150,"correct":32},"50m",{"key":24,"text":152,"correct":32},"60m",{"key":27,"text":154,"correct":32},"40m",{"key":30,"text":156,"correct":22},"80m",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":36,"analysis":37},935592,"防火检查中，通过对防火门的（）等进行检查，核实防火门的设置是否符合现行国家工程建设消防技术标准的要求。",[161,163,165,167,169],{"key":20,"text":162,"correct":22},"选型",{"key":24,"text":164,"correct":22},"系统功能",{"key":27,"text":166,"correct":22},"外观",{"key":30,"text":168,"correct":32},"材质",{"key":34,"text":170,"correct":22},"安装质量",{"id":172,"libraryId":5,"type":145,"typeLabel":146,"stem":173,"options":174,"answer":24,"analysis":37},935593,"某大型建筑地下商店采用防火隔间分隔，下列关于防火隔间的检查结果，不符合规范要求的是（ ）。",[175,177,179,181],{"key":20,"text":176,"correct":32},"防火隔间的建筑面积为7．0 m2",{"key":24,"text":178,"correct":22},"防火隔间墙采用耐火极限3．00h的防火隔墙，门采用乙级防火门",{"key":27,"text":180,"correct":32},"不同防火分区通向防火隔间的门的最小间距为5m",{"key":30,"text":182,"correct":32},"防火隔间内部装修材料均采用A级材料",{"id":184,"libraryId":5,"type":145,"typeLabel":146,"stem":185,"options":186,"answer":30,"analysis":37},935594,"某超高层住宅，地上40层，地下2层，地下2层使用功能为汽车库。该建筑按规定设有相应的消防设施，则住宅部分每个防火分区的最大允许建筑面积不应大于（ ）㎡。",[187,189,191,193],{"key":20,"text":188,"correct":32},"1200",{"key":24,"text":190,"correct":32},"2500",{"key":27,"text":192,"correct":32},"1500",{"key":30,"text":194,"correct":22},"3000",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":36,"analysis":37},935595,"对防火墙设置位置的检查要求有（ ）。",[199,201,203,205,207],{"key":20,"text":200,"correct":22},"设置在建筑物的基础或钢筋混凝土框架、梁等承重结构上，从楼地面基层隔断至梁、楼板或屋面结构层的底面",{"key":24,"text":202,"correct":22},"如设置在转角附近，内转角两侧墙上的门、窗洞口之间最近边缘的水平距离不小于4．0m；当采取设置乙级防火窗等防止火灾水平蔓延的措施时，距离可不限",{"key":27,"text":204,"correct":22},"防火墙的构造在防火墙任意一侧的屋架、梁、楼板等受到火灾的影响而破坏时，不会导致防火墙倒塌",{"key":30,"text":206,"correct":32},"防火墙上一般不开设门、窗、洞口，必须开设时，需设置不可开启或火灾时能自动关闭的乙级防火门、窗，防止建筑内火灾的浓烟和火焰穿过门窗洞口蔓延扩散",{"key":34,"text":208,"correct":22},"紧靠防火墙两侧的门、窗、洞口之间最近边缘的水平距离不得小于2．0m；采取设置乙级防火窗等防止火灾水平蔓延的措施时，距离可不限",{"id":210,"libraryId":5,"type":145,"typeLabel":146,"stem":211,"options":212,"answer":27,"analysis":37},935596,"挡烟高度即指各类挡烟设施处于安装位置时，其底部与顶部之间的垂直高度，要求不得小于（）mm。",[213,215,217,219],{"key":20,"text":214,"correct":32},"300",{"key":24,"text":216,"correct":32},"400",{"key":27,"text":218,"correct":22},"500",{"key":30,"text":220,"correct":32},"600",{"id":222,"libraryId":5,"type":145,"typeLabel":146,"stem":223,"options":224,"answer":24,"analysis":37},935597,"以下关于防火墙的说法，正确的是（）。",[225,227,229,231],{"key":20,"text":226,"correct":32},"防火墙是防止火灾蔓延至相邻建筑或相邻水平防火分区且耐火极限不低于2．00h的不燃性实体墙",{"key":24,"text":228,"correct":22},"防火墙从建筑基础部分就要与建筑物完全断开，独立建造",{"key":27,"text":230,"correct":32},"防火墙能将火灾有效地限制在一定空间内，保证火灾肯定不会蔓延",{"key":30,"text":232,"correct":32},"采取设置乙级防火窗等防止火灾水平蔓延的措施时，距离需要限制",{"id":234,"libraryId":5,"type":145,"typeLabel":146,"stem":235,"options":236,"answer":20,"analysis":37},935598,"防火隔间内部装修材料的燃烧性能均采用（）材料。",[237,239,241,243],{"key":20,"text":238,"correct":22},"A级",{"key":24,"text":240,"correct":32},"B级",{"key":27,"text":242,"correct":32},"C级",{"key":30,"text":244,"correct":32},"D级",{"id":246,"libraryId":5,"type":145,"typeLabel":146,"stem":247,"options":248,"answer":30,"analysis":37},935599,"某难燃铝塑材料加工厂房，地上1层，耐火等级为四级，当设有自动喷水灭火系统时，每个防火分区的建筑面积（ ）。",[249,251,253,255],{"key":20,"text":250,"correct":32},"不应大于4000㎡",{"key":24,"text":252,"correct":32},"不应大于3000㎡",{"key":27,"text":254,"correct":32},"不应大于2000㎡",{"key":30,"text":256,"correct":22},"不限",{"id":258,"libraryId":5,"type":145,"typeLabel":146,"stem":259,"options":260,"answer":27,"analysis":37},935600,"某储存仓库，耐火等级为一级，地上3层，地下1层，层高4m，占地面积为1500㎡，首层储存物品为搪瓷制品、二层储存有成品服装，三层为针织原料，地下一层储存玻璃，消防机构对该仓库进行防火检查，检查结果如下，其中符合现行国家技术标准的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":32},"因工艺需要该建筑地下划分出100㎡做喷漆间，采用耐火极限为3.0h的防火墙与其他部位分隔",{"key":24,"text":264,"correct":32},"仓库首层防火分区之间采用耐火极限为3．0h的防火墙",{"key":27,"text":266,"correct":22},"仓库第二层划分为2个防火分区",{"key":30,"text":268,"correct":32},"仓库第三层防火分区之间采用耐火极限为3．0h防火卷帘代替",{"id":270,"libraryId":5,"type":145,"typeLabel":146,"stem":271,"options":272,"answer":30,"analysis":37},935601,"某一级耐火等级的2层商场，室内空间净高6m，标准层建筑面积为4500㎡，每层划分成面积均等的两个防火分区，该商场至少应划分（ ）个防烟分区。",[273,275,277,279],{"key":20,"text":274,"correct":32},"9",{"key":24,"text":276,"correct":32},"18",{"key":27,"text":278,"correct":32},"6",{"key":30,"text":280,"correct":22},"12",{"id":282,"libraryId":5,"type":145,"typeLabel":146,"stem":283,"options":284,"answer":27,"analysis":37},935602,"下列场所中，关于防烟分区的说法，错误的是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":32},"某商业中心，建筑高度为24m，室内空间净高为5．5m，其防烟分区最大允许面积为1000㎡",{"key":24,"text":288,"correct":32},"某停车位为151个的地下车库，室内空间净高为6．5m，其防烟分区最大允许面积为2000㎡",{"key":27,"text":290,"correct":22},"某办公建筑，建筑高度为50m，室内空间净高为3．0m，其防烟分区最大允许面积为1000㎡",{"key":30,"text":292,"correct":32},"某高层电石炉厂房，室内空间净高为9．5m，防烟分区之间可不设置挡烟设施",{"id":294,"libraryId":5,"type":145,"typeLabel":146,"stem":295,"options":296,"answer":20,"analysis":37},935603,"活动性挡烟垂壁采用连续性布置时，各块之间不应有缝隙，搭接宽度不应小于（ ）mm。",[297,299,301,303],{"key":20,"text":298,"correct":22},"100",{"key":24,"text":300,"correct":32},"150",{"key":27,"text":302,"correct":32},"200",{"key":30,"text":304,"correct":32},"250",{"id":306,"libraryId":5,"type":145,"typeLabel":146,"stem":307,"options":308,"answer":30,"analysis":37},935604,"某12层的住宅建筑，首层及二层为商业服务网点，下列说法不正确的是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":32},"住宅部分与商业网点之间应采用耐火极限2．00h且无门、窗、洞口的防火隔墙和1．50h的不燃性楼板完全分隔",{"key":24,"text":312,"correct":32},"各商业网点之间应采用耐火极限2．00h且无门、窗、洞口的防火隔墙相互分隔",{"key":27,"text":314,"correct":32},"住宅部分和商业网点的疏散楼梯应单独设置",{"key":30,"text":316,"correct":22},"商业网点单元内任一点至最近直通室外的出口的直线距离不允许超过20m",{"id":318,"libraryId":5,"type":145,"typeLabel":146,"stem":319,"options":320,"answer":20,"analysis":37},935605,"当中庭与周围连通空间的防火分隔采用防火玻璃时，防火玻璃与其固定部件整体的耐火极限不低于（ ）h。",[321,323,325,327],{"key":20,"text":322,"correct":22},"1．00",{"key":24,"text":324,"correct":32},"2．00",{"key":27,"text":326,"correct":32},"3．00",{"key":30,"text":328,"correct":32},"4．00",{"id":330,"libraryId":5,"type":145,"typeLabel":146,"stem":331,"options":332,"answer":30,"analysis":37},935606,"某三层内廊式办公楼，建筑高度为12．5 m，三级耐火等级，设置自动喷水灭火系统，每层建筑面积为1400 m2，有2部采用双向弹簧门的封闭式楼梯间。该办公楼每层一个防火分区的最大建筑面积为（ ）m2。",[333,334,336,338],{"key":20,"text":188,"correct":32},{"key":24,"text":335,"correct":32},"2400",{"key":27,"text":337,"correct":32},"2800",{"key":30,"text":339,"correct":22},"1400",{"id":341,"libraryId":5,"type":145,"typeLabel":146,"stem":342,"options":343,"answer":24,"analysis":37},935607,"进行防火分区检查时，符合现行国家工程消防技术标准要求的是（ ）。",[344,346,348,350],{"key":20,"text":345,"correct":32},"硫黄仓库位于地下一层，全部设置自动喷水灭火系统时，防火分区最大面积可为120m2",{"key":24,"text":347,"correct":22},"二级耐火等级建筑内的商店营业厅仅设置在五层建筑的首层，设置自动灭火系统和火灾自动报警系统并采用不燃或难燃装修材料时，防火分区的面积可为10000 m2",{"key":27,"text":349,"correct":32},"52°白酒仓库位于地下一层，全部设置自动喷水灭火系统时，防火分区最大面积可为250 m2",{"key":30,"text":351,"correct":32},"某办公楼设置在地下的设备用房的防火分区面积最大不应大于500m2，全部设置自动喷水灭火系统时可增至1000 m2",{"id":353,"libraryId":5,"type":145,"typeLabel":146,"stem":354,"options":355,"answer":20,"analysis":37},935608,"下列关于防火分区的做法中，错误的是（）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"建筑局部设有自动灭火系统，防火分区的增加面积按该局部面积增加0．5倍计算",{"key":24,"text":359,"correct":32},"建筑第一至三层设置自动扶梯，防火分区的建筑面积按连通3个楼层的建筑面积叠加计算，并按照规范规定划分防火分区",{"key":27,"text":361,"correct":32},"叠加计算错层式汽车库上下连通层的建筑面积，防火分区的最大允许建筑面积可按规范增加1倍",{"key":30,"text":363,"correct":32},"人防工程中的水泵房、污水泵房、水池、厕所等无可燃物的房间面积可不计入防火分区面积",{"id":365,"libraryId":5,"type":145,"typeLabel":146,"stem":366,"options":367,"answer":27,"analysis":37},935609,"下列关于人防工程的检查，错误的是（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":32},"卡拉OK厅设置在地下一层",{"key":24,"text":371,"correct":32},"水泵房没有计入防火分区的建筑面积",{"key":27,"text":373,"correct":22},"人防工程的地下二层旅店与员工宿舍划分为同一防火分区",{"key":30,"text":375,"correct":32},"游泳馆的游泳池其面积可不计入游泳馆的防火分区面积内，装修材料为A级",{"id":377,"libraryId":5,"type":145,"typeLabel":146,"stem":378,"options":379,"answer":24,"analysis":37},935610,"某三级耐火等级的5层办公建筑，当建筑内全部设置自动喷水灭火系统进行保护时，其每个防火分区的面积最多可增加（ ）m2",[380,381,382,383],{"key":20,"text":220,"correct":32},{"key":24,"text":188,"correct":22},{"key":27,"text":335,"correct":32},{"key":30,"text":384,"correct":32},"3600",{"id":386,"libraryId":5,"type":145,"typeLabel":146,"stem":387,"options":388,"answer":27,"analysis":37},935611,"某多层空分厂房，耐火等级二级，地上3层，设有自动喷水灭火系统，每层建筑面积均为3500m2，设有一部封闭楼梯间，一部室外楼梯。则该车间每层防火分区的最大建筑面积为（ ）m2。",[389,391,393,395],{"key":20,"text":390,"correct":32},"2000m2",{"key":24,"text":392,"correct":32},"7500m2",{"key":27,"text":394,"correct":22},"3500m2",{"key":30,"text":396,"correct":32},"6000m2",{"id":398,"libraryId":5,"type":145,"typeLabel":146,"stem":399,"options":400,"answer":24,"analysis":37},935612,"某地下一层商场划分为多个区域，各区域之间采用下沉式广场、防火隔间、防烟楼梯间等方式相连，下列关于防火隔间的说法，不正确的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":32},"防火隔间的建筑面积不小于 6.0 ㎡采用甲级防火门。",{"key":24,"text":404,"correct":22},"防火分区通向防火隔间的门可以计入该防火分区的安全出口",{"key":27,"text":406,"correct":32},"不同防火分区通向防火隔间的门的最小间距不应小于 4m",{"key":30,"text":408,"correct":32},"防火隔间内部装修材料的燃烧等级应为 A 级",{"id":410,"libraryId":5,"type":145,"typeLabel":146,"stem":411,"options":412,"answer":30,"analysis":37},935613,"公共建筑内厨房的排油烟管道与竖向风管连接的支管处设置的防火阀，公称动作温度为（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":32},"50℃",{"key":24,"text":416,"correct":32},"70℃",{"key":27,"text":418,"correct":32},"100℃",{"key":30,"text":420,"correct":22},"150℃",{"id":422,"libraryId":5,"type":145,"typeLabel":146,"stem":423,"options":424,"answer":24,"analysis":37},935614,"歌舞娱乐放映游艺场所与建筑内其他部位相通的门应为（ ）防火门。",[425,427,429,431],{"key":20,"text":426,"correct":32},"甲级",{"key":24,"text":428,"correct":22},"乙级",{"key":27,"text":430,"correct":32},"丙级",{"key":30,"text":432,"correct":32},"丁级",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":447,"analysis":37},935615,"民用建筑在划分防火分区时，确定防火分区面积的主要因素有（ ）。",[437,439,441,443,445],{"key":20,"text":438,"correct":22},"耐火等级",{"key":24,"text":440,"correct":22},"自动灭火系统设置情况",{"key":27,"text":442,"correct":22},"建筑高度",{"key":30,"text":444,"correct":32},"疏散距离",{"key":34,"text":446,"correct":32},"防火间距","ABC",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":462,"analysis":37},935616,"某商场地上4层，地下两层，地上部分为商场，地下一层为超市，地下二层为设备用房，建筑全部设置自动喷水灭火系统和火灾自动报警系统等，并采用不燃性材料进行内部装修。下列关于防火分区划分的做法中，正确的是（ ）。",[452,454,456,458,460],{"key":20,"text":453,"correct":22},"地上二层的防火分区中最大一个的建筑面积为4950㎡",{"key":24,"text":455,"correct":32},"地上一层的防火分区中最大一个的建筑面积为9900㎡",{"key":27,"text":457,"correct":22},"地上三层的防火分区中最大一个的建筑面积为1990㎡",{"key":30,"text":459,"correct":22},"地下一层的防火分区中最大一个的建筑面积为1980㎡",{"key":34,"text":461,"correct":22},"地下二层设备用房划分为一个防火分区，建筑面积1990㎡","ACDE",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":477,"analysis":37},935617,"某带顶棚的步行街，且步行街两侧的建筑需利用步行街进行安全疏散时，下列关于步行街两侧商铺的防火分隔措施的说法中，错误的是（ ）。",[467,469,471,473,475],{"key":20,"text":468,"correct":22},"商铺之间应采用防火墙进行防火分隔",{"key":24,"text":470,"correct":32},"每间商铺的建筑面积不宜大于300㎡",{"key":27,"text":472,"correct":22},"商铺面向步行街一侧的围护结构的耐火极限不应低于1．50h",{"key":30,"text":474,"correct":32},"商铺面向步行街一侧的围护结构可采用实体墙、防火玻璃墙",{"key":34,"text":476,"correct":32},"相邻商铺之间面向步行街一侧的实体墙，耐火极限不应低于1．00h","AC",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":492,"analysis":37},935618,"防火门在安装时，应注意门扇的活动间隙，下列说法中，错误的是（ ）。",[482,484,486,488,490],{"key":20,"text":483,"correct":32},"门扇与门框的搭接尺寸不应小于12mm",{"key":24,"text":485,"correct":22},"门扇与上框的配合活动间隙不应大于5mm",{"key":27,"text":487,"correct":22},"多扇门的门扇之间的间隙不应大于2mm",{"key":30,"text":489,"correct":32},"门扇与门框贴合面间隙不应大于3mm",{"key":34,"text":491,"correct":32},"门扇与下框或地面的活动间隙不应大于9mm","BC",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":507,"analysis":37},935619,"建筑内的管道和管道井是火灾烟气和火灾蔓延的通道之一，在对竖向井道进行检查时，符合规范要求的包括（ ）。",[497,499,501,503,505],{"key":20,"text":498,"correct":32},"电缆井在每层楼板处采用难燃材料封堵",{"key":24,"text":500,"correct":22},"电缆井道井壁耐火极限不低于1．00 h，井壁上的检查门为丙级防火门",{"key":27,"text":502,"correct":22},"电梯井独立设置，井内严禁敷设可燃气体和甲、乙、丙类液体管道",{"key":30,"text":504,"correct":22},"垃圾斗采用不燃烧材料制作，并能自行关闭",{"key":34,"text":506,"correct":22},"电梯门的耐火极限不低于1．00 h，并同时符合相关完整性和隔热性要求","BCDE",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":492,"analysis":37},935620,"近年来，很多餐饮、商店等商业设施都通过有顶棚的步行街连接，与步行街相连的商业设施内一旦发生火灾，如果控制不好，很容易造成火灾的蔓延。下列关于某步行街的设置，不符合规范要求的是（ ）。",[512,514,516,518,520],{"key":20,"text":513,"correct":32},"步行街两侧建筑的耐火等级不应低于二级",{"key":24,"text":515,"correct":22},"步行街两侧建筑的商铺之间设置耐火极限1.50h的防火隔墙，每间商铺的建筑面积200 m2",{"key":27,"text":517,"correct":22},"步行街内任一点到达最近室外安全地点的直线距离为70m",{"key":30,"text":519,"correct":32},"步行街两侧建筑的商铺面向步行街一侧围护构件的耐火极限为1．50h，采用乙级防火门",{"key":34,"text":521,"correct":32},"相邻商铺之间面向步行街一侧设置宽度为1．5m、耐火极限1．00h的实体墙",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":52,"analysis":37},935621,"某人防工程内设有商场、歌舞厅、电影院以及各类设备用房，下列关于部位之间防火分隔措施的做法中，错误的有（ ）。",[526,528,530,532,534],{"key":20,"text":527,"correct":32},"电影院的观众厅与舞台之间的隔墙，耐火极限为2.50h",{"key":24,"text":529,"correct":32},"消防控制室与其他部位之间的隔墙，耐火极限为2.00h，墙上设置常闭的甲级防火门",{"key":27,"text":531,"correct":22},"通信机房与其他部位之间的隔墙，耐火极限为2.00h，墙上设置常闭的乙级防火门",{"key":30,"text":533,"correct":22},"柴油发电机房的储油间，墙上设置常闭的甲级防火门，并设置高100mm的不燃烧、不渗漏的门槛",{"key":34,"text":535,"correct":22},"电影院放映室采用耐火极限为0.50的隔墙与其他部位分隔",{"id":537,"libraryId":5,"type":145,"typeLabel":146,"stem":538,"options":539,"answer":27,"analysis":37},935622,"某耐火等级为二级的办公建筑，地上3层，每层建筑面积为1400㎡，建筑未设置自动喷水灭火系统。对该办公楼进行防火检查，下列检查结果中，不符合现行国家消防技术标准的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":32},"每层划分为1个防火分区",{"key":24,"text":543,"correct":32},"建筑内位于袋形走道两侧的某个房间，建筑面积为100㎡，设置了1个疏散门",{"key":27,"text":545,"correct":22},"位于二层袋型走道尽端，建筑面积为400㎡的会议厅，设置了1个1．4m的疏散门",{"key":30,"text":547,"correct":32},"建筑采用封闭楼梯间",{"id":549,"libraryId":5,"type":145,"typeLabel":146,"stem":550,"options":551,"answer":30,"analysis":37},935623,"某体育馆观众厅设计疏散人数为3500人，观众厅内为阶梯地面，耐火等级为二级，观众厅内前后排座椅的排距为1．2m，则纵走道之间的座位数最多可设置（ ）个。",[552,554,556,558],{"key":20,"text":553,"correct":32},"22",{"key":24,"text":555,"correct":32},"20",{"key":27,"text":557,"correct":32},"26",{"key":30,"text":559,"correct":22},"50",{"id":561,"libraryId":5,"type":145,"typeLabel":146,"stem":562,"options":563,"answer":27,"analysis":37},935624,"某6层商场建筑高度为31．2m，每层层高为5．2m，每层建筑面积为3600㎡，按照要求设置了消防设施。对该商场进行防火检查，下列检查结果中可以确定不符合规范要求的是（ ）。",[564,566,568,570],{"key":20,"text":565,"correct":32},"商场楼梯间的首层疏散门的宽度为1．4m",{"key":24,"text":567,"correct":32},"三层位于两个安全出口之间的KTV的疏散门至最近的安全出口之间的距离为25m",{"key":27,"text":569,"correct":22},"建筑采用封闭楼梯间，楼梯间的门采用乙级防火门",{"key":30,"text":571,"correct":32},"位于二层两安全出口之间的建筑面积为400㎡网吧的疏散门至最近的安全出口之间的距离为30m",{"id":573,"libraryId":5,"type":145,"typeLabel":146,"stem":574,"options":575,"answer":24,"analysis":37},935625,"某三级耐火等级的2层丙类厂房，每层划分为一个防火分区。下列关于该厂房的做法，错误的是（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":32},"厂房内最远点到最近安全出口之间的直线距离为37m",{"key":24,"text":579,"correct":22},"二层设置两个安全出口，其中2个相邻的安全出口之间的距离最小为4m",{"key":27,"text":581,"correct":32},"厂房内疏散走道的最小净宽度为1．4m",{"key":30,"text":583,"correct":32},"厂房内设置封闭楼梯间",{"id":585,"libraryId":5,"type":145,"typeLabel":146,"stem":586,"options":587,"answer":30,"analysis":37},935626,"体育馆建筑均为一、二级耐火等级，依据容量的不同，人员从观众厅疏散出去的时间一般按3～4min控制，每个疏散门的平均疏散人数一般不超过（ ）人。",[588,590,592,594],{"key":20,"text":589,"correct":32},"300～500",{"key":24,"text":591,"correct":32},"300～600",{"key":27,"text":593,"correct":32},"400～600",{"key":30,"text":595,"correct":22},"400～700",{"id":597,"libraryId":5,"type":145,"typeLabel":146,"stem":598,"options":599,"answer":27,"analysis":37},935627,"除甲、乙类生产车间外，人数不超过（ ）人且每道门的平均疏散人数不超过30人的房间，其疏散门的开启方向不限。",[600,602,603,605],{"key":20,"text":601,"correct":32},"30",{"key":24,"text":559,"correct":32},{"key":27,"text":604,"correct":22},"60",{"key":30,"text":606,"correct":32},"80",{"id":608,"libraryId":5,"type":145,"typeLabel":146,"stem":609,"options":610,"answer":20,"analysis":37},935628,"直通疏散走道的房间疏散门至最近敞开楼梯间的距离，当房间位于两个楼梯间之间时，按规定减少（ ）m；当房间位于袋型走道两侧或尽端时，按规定减少（ ）m。",[611,613,615,617],{"key":20,"text":612,"correct":22},"5，2",{"key":24,"text":614,"correct":32},"3，2",{"key":27,"text":616,"correct":32},"4，2",{"key":30,"text":618,"correct":32},"6，3",{"id":620,"libraryId":5,"type":145,"typeLabel":146,"stem":621,"options":622,"answer":24,"analysis":37},935629,"裙房和建筑高度不大于32m的二类高层公共建筑应采用（ ）。",[623,625,627,629],{"key":20,"text":624,"correct":32},"防烟楼梯间",{"key":24,"text":626,"correct":22},"封闭楼梯间",{"key":27,"text":628,"correct":32},"敞开楼梯间",{"key":30,"text":630,"correct":32},"室外楼梯",{"id":632,"libraryId":5,"type":145,"typeLabel":146,"stem":633,"options":634,"answer":27,"analysis":37},935630,"对某建筑高度为280 m的综合商业楼进行检查，其避难层（间）设置不符合规范规定的是（ ）。",[635,637,639,641],{"key":20,"text":636,"correct":32},"避难层设置消防电梯出口",{"key":24,"text":638,"correct":32},"从首层到第一个避难层之间的高度为48 m，相邻避难层之间的高度为49 m",{"key":27,"text":640,"correct":22},"避难间位置靠近楼梯间并采用耐火极限不低于2．00 h的防火隔墙和乙级防火门与其他部位分隔",{"key":30,"text":642,"correct":32},"避难间的净面积能满足设计避难人员避难的要求，每个护理单元面积为30 m2",{"id":644,"libraryId":5,"type":145,"typeLabel":146,"stem":645,"options":646,"answer":27,"analysis":37},935631,"对某建筑高度为240m的办公大楼建筑进行防火检查，下列关于该建筑避难层的检查结果中，不符合现行国家消防技术标准的是（ ）。",[647,649,651,653],{"key":20,"text":648,"correct":32},"设置了可直接对外开启的乙级防火窗",{"key":24,"text":650,"correct":32},"避难层内疏散应急照明的地面最低水平照度为5．0lx",{"key":27,"text":652,"correct":22},"在避难层设置的设备用房与避难区之间采用防火墙分隔，墙上开设甲级防火门，距避难区出口距离为3m",{"key":30,"text":654,"correct":32},"在避难层设置消防专线电话、应急广播、消火栓和消防软管卷盘",{"id":656,"libraryId":5,"type":145,"typeLabel":146,"stem":657,"options":658,"answer":24,"analysis":37},935632,"对某高层公共建筑进行防火检查时，通过查阅资料得知，该建筑耐火等级为一级，建筑高度28m，每层建筑面积6000m2，使用功能为宾馆、办公室，设有自动喷水灭火系统。该建筑的下列做法中，不符合现行国家消防技术标准的是（ ）。",[659,661,663,665],{"key":20,"text":660,"correct":32},"设有2台消防电梯",{"key":24,"text":662,"correct":22},"消防电梯前室与楼梯间前室合用，合用前室建筑面积为10m2",{"key":27,"text":664,"correct":32},"合用前室的门采用乙级防火门",{"key":30,"text":666,"correct":32},"消防电梯兼做客梯",[668,671,674,677,680,683],{"id":145,"name":669,"category":7,"favorite":670},"领导干部任职前廉政法规知识测试题",92,{"id":672,"name":673,"category":7,"favorite":145},595,"建筑结构与设备",{"id":675,"name":676,"category":7,"favorite":145},715,"招标采购专业知识与法律法规",{"id":678,"name":679,"category":7,"favorite":145},848,"市政方向-通用基础",{"id":681,"name":682,"category":7,"favorite":8},534,"BIM工程师",{"id":684,"name":682,"category":7,"favorite":8},535]