[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":644},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,18,50,2974,[13,38,53,68,83,98,112,126,138,150,161,173,185,196,208,220,232,244,256,268,278,290,302,314,326,338,350,361,373,385,397,407,419,431,443,455,467,482,497,511,525,540,548,560,572,584,596,608,620,632],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},935533,2,"多选题","某甲类单层厂房，耐火等级为一级，建筑高度为18 m，建筑面积为3000 m2。下列做法中，符合规范规定的有（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","在厂房外与厂房一面贴邻设置办公室，贴邻面使用无门窗洞口的3．00 h防火墙和1．50h的楼板",false,{"key":24,"text":25,"correct":22},"B","在厂房外与厂房一面贴邻设置休息室，贴邻面使用无门窗洞口的4．00 h防火墙和1．50 h的楼板",{"key":27,"text":28,"correct":29},"C","厂房内设置丙类液体中间储罐的专用房间，采用耐火极限不低于3．00 h的防火隔墙和1．50 h的楼板与其他部位分隔，房间门应采用甲级防火门",true,{"key":31,"text":32,"correct":22},"D","厂房内设置的丙类中间仓库，采用防火墙和耐火极限为1．00 h的不燃性楼板与其他部位分隔",{"key":34,"text":35,"correct":29},"E","厂房内设置的甲类中间仓库，储量不宜超过一昼夜的需要量；靠外墙布置，并采用防火墙和耐火极限不低于1．50 h的不燃性楼板与其他部位隔开","CE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},935534,"某KTV设置在建筑高度为60 m的多功能组合建筑的第六层，设置了自动喷水灭火系统和火灾报警系统，其设计不符合相应规范要求的有（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":29},"最大房间建筑面积为220 m2",{"key":24,"text":45,"correct":22},"房间和房间之间采用了耐火极限为2．00 h的防火隔墙和1．50 h的楼板进行分隔",{"key":27,"text":47,"correct":29},"房间墙上的门为丙级防火门",{"key":31,"text":49,"correct":29},"顶棚采用了耐火等级为B1级的装修材料",{"key":34,"text":51,"correct":22},"布置在袋形走道尽端的最远房间的疏散门至最近安全出口的距离为11 m","ACD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},935535,"对某人防工程进行防火检查，其设置符合规范要求的有（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"地下一层设置油浸电力变压器，采用耐火极限不低于3．00h的不燃烧体墙和耐火极限不低于1．00h的楼板与其他场所隔开",{"key":24,"text":60,"correct":29},"地下二层设置商店营业厅，采用耐火极限不低于3．00 h的防火墙和耐火极限不低于2．00h的楼板与其他场所隔开",{"key":27,"text":62,"correct":22},"地下一层设置KTV，采用耐火极限不低于2．00 h的不燃烧体墙和耐火极限不低于1．00 h的楼板与其他场所隔开",{"key":31,"text":64,"correct":29},"消防控制室设置在地下一层，并邻近直接通向地面的安全出口，采用耐火极限不低于2．00 h的隔墙和耐火极限不低于1．50 h的楼板与其他部位隔开",{"key":34,"text":66,"correct":22},"地下一层商店营业厅销售袋装氧气","BD",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},935536,"对民用建筑实施防火检查时，检查人员应注意查看特殊功能场所不能设置在地下或半地下，且不应设置在四层及四层以上的用房有（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":29},"托儿所、幼儿园的儿童用房",{"key":24,"text":75,"correct":22},"医院的住院部分",{"key":27,"text":77,"correct":22},"疗养院的住院部分",{"key":31,"text":79,"correct":29},"儿童游乐厅等儿童活动场所",{"key":34,"text":81,"correct":22},"老年人活动场所","AD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},935537,"某汽车轮毂打磨厂房，地上2层，建筑高度为12 m，建筑面积为5600 m2。在防火检查时获取的下列信息中，正确的有（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":29},"屋顶钢承重构件涂刷防火涂料保护，耐火极限达到1．0 h",{"key":24,"text":90,"correct":29},"除尘管道避开厂房的梁、柱，沿外墙布置",{"key":27,"text":92,"correct":22},"一层设置办公室，并采用防火墙和耐火极限不低于1．5 h的楼板与其他部位分隔",{"key":31,"text":94,"correct":29},"厂房设封闭楼梯间，并采用乙级防火门",{"key":34,"text":96,"correct":29},"排风除尘设备集中布置在室外独立的建筑内，该建筑外墙与厂房的防火间距为10 m","ABDE",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":36,"analysis":37},935538,"南方某工业厂区，占地面积为180hm2，长方形地块，其宽度为1000m，消防水泵房为独立建筑且设置在地块的中心位置，消防给水系统采用室内外合用的临时高压系统，系统设计流量和压力分别为120L／s、1．0MPa，厂区消防控制室至消防水泵房行走距离为800m。验收时，下列检测结果中，符合现行国家消防技术标准的有（ ）。",[102,104,106,108,110],{"key":20,"text":103,"correct":22},"消防水泵房地面与室外地坪高差为50mm，没有挡水设施",{"key":24,"text":105,"correct":22},"室外最不利点消火栓到消防泵房的行走距离为1350m",{"key":27,"text":107,"correct":29},"稳压泵设计流量为3L／s",{"key":31,"text":109,"correct":22},"消防水泵“五用一备”",{"key":34,"text":111,"correct":29},"消防水泵房不设置值班室",{"id":113,"libraryId":5,"type":114,"typeLabel":115,"stem":116,"options":117,"answer":20,"analysis":37},935539,1,"单选题","防火卷帘的控制器和手动按钮盒分别安装在防火卷帘内外两侧的墙壁便于识别的位置，底边距地面高度宜为（ ）m，并标出上升、下降、停止等功能。",[118,120,122,124],{"key":20,"text":119,"correct":29},"1．3～1．5",{"key":24,"text":121,"correct":22},"1．0～1．3",{"key":27,"text":123,"correct":22},"1．2～1．5",{"key":31,"text":125,"correct":22},"1．5～2．0",{"id":127,"libraryId":5,"type":114,"typeLabel":115,"stem":128,"options":129,"answer":24,"analysis":37},935540,"一座占地面积2500㎡，存储石蜡的二级耐火等级多层仓库，其防火分区的建筑面积最大为（ ）㎡。",[130,132,134,136],{"key":20,"text":131,"correct":22},"1500",{"key":24,"text":133,"correct":29},"1400",{"key":27,"text":135,"correct":22},"700",{"key":31,"text":137,"correct":22},"950",{"id":139,"libraryId":5,"type":114,"typeLabel":115,"stem":140,"options":141,"answer":27,"analysis":37},935541,"某商店建筑，地上8层，建筑高度27m耐火等级为一级，建筑内设有连通上下各层的中庭，与中庭相连通的区域面积为4500㎡，下列关于中庭与周围连通空间防火分隔的说法，错误的是（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":22},"当采用防火卷帘时，其耐火极限不应低于3．00h",{"key":24,"text":145,"correct":22},"当采用防火玻璃墙时，其耐火隔热性和耐火完整性不应低于1．00h",{"key":27,"text":147,"correct":29},"当采用防火隔墙时，其耐火极限不应低于3．00h",{"key":31,"text":149,"correct":22},"与中庭相连通的门、窗，应采用火灾时能自行关闭的甲级防火门窗",{"id":151,"libraryId":5,"type":114,"typeLabel":115,"stem":152,"options":153,"answer":24,"analysis":37},935542,"某建筑高度24．2m的医疗建筑，设有两层裙房，裙房与主体用耐火极限为3．00h的防火卷帘完全分隔，则裙房的防火分区最大允许建筑面积可为（ ）㎡。",[154,156,158,160],{"key":20,"text":155,"correct":22},"2500",{"key":24,"text":157,"correct":29},"3000",{"key":27,"text":159,"correct":22},"5000",{"key":31,"text":131,"correct":22},{"id":162,"libraryId":5,"type":114,"typeLabel":115,"stem":163,"options":164,"answer":20,"analysis":37},935543,"下列关于防火分区的说法，错误的是（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":29},"民用建筑局部设有自动灭火系统，防火分区的增加面积按该局部面积增加2倍计算",{"key":24,"text":168,"correct":22},"建筑首层至三层设置自动扶梯，防火分区的建筑面积按连通3个楼层的建筑面积叠加计算，并按照规范规定划分防火分区",{"key":27,"text":170,"correct":22},"叠加计算错层式汽车库上、下连通层的建筑面积，防火分区的最大允许建筑面积可按规范增加1倍",{"key":31,"text":172,"correct":22},"人防工程中的水泵房、污水泵房、水池、厕所等无可燃物的房间面积可不计入防火分区面积",{"id":174,"libraryId":5,"type":114,"typeLabel":115,"stem":175,"options":176,"answer":27,"analysis":37},935544,"某服装加工厂房，二级耐火等级，地上3层，地下1层，层高6．2m，室内净空高为6．0m，每层建筑面积6000㎡，按照国家规定设有相应的消防设施，消防机构对该厂房进行防火检查，结果如下，其中不符合现行国家技术标准的是（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":22},"厂房地上每层划分为1个防火分区",{"key":24,"text":180,"correct":22},"地上三层防火分区之间采用耐火极限为3．0h的防火墙分隔",{"key":27,"text":182,"correct":29},"厂房地下部分划分为4个防烟分区",{"key":31,"text":184,"correct":22},"厂房首层因运输需要，防火分区之间采用耐火极限为3．0h的防火卷帘分隔",{"id":186,"libraryId":5,"type":114,"typeLabel":115,"stem":187,"options":188,"answer":24,"analysis":37},935545,"某2层自行车装配厂房，耐火等级为二级，层高5m，二层设置有一个单层润滑油中间仓库，库房内未设置自动喷水灭火系统，则该中间仓库每个防火分区的最大允许面积为（ ）㎡。",[189,191,192,194],{"key":20,"text":190,"correct":22},"1000",{"key":24,"text":135,"correct":29},{"key":27,"text":193,"correct":22},"2000",{"key":31,"text":195,"correct":22},"1200",{"id":197,"libraryId":5,"type":114,"typeLabel":115,"stem":198,"options":199,"answer":31,"analysis":37},935546,"某单层大型地下商场建筑面积为38000㎡，采用防火隔间将商场划分成2个建筑面积不大于20000㎡的相对独立的区域。下列关于防火隔间的做法，不符合规范要求的是（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":22},"防火隔间的建筑面积为6．0㎡",{"key":24,"text":203,"correct":22},"防火隔间的门采用甲级防火门",{"key":27,"text":205,"correct":22},"不应用于除人员通行外的其他用途",{"key":31,"text":207,"correct":29},"其中一个防火分区只有一个直通室外的安全出口，利用防火隔间的门作为第二个安全出口",{"id":209,"libraryId":5,"type":114,"typeLabel":115,"stem":210,"options":211,"answer":20,"analysis":37},935547,"下列设施可被当做挡烟垂壁的是（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":29},"楼板下凸出800mm金属板",{"key":24,"text":215,"correct":22},"楼板下凸出450mm的无机纤维织物",{"key":27,"text":217,"correct":22},"吊顶下凸出550mm的难燃烧体复合板",{"key":31,"text":219,"correct":22},"吊顶下凸出400mm的防火玻璃",{"id":221,"libraryId":5,"type":114,"typeLabel":115,"stem":222,"options":223,"answer":20,"analysis":37},935548,"某建筑高度为42m，耐火等级为一级，地上10层，地下2层。一到三层为商业部分，四层至十层为办公区域，地下第二层为汽车库，建筑内全部设置了自动喷水灭火系统，该建筑的办公区域和汽车库防火分区的最大允许面积分别为（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":29},"3000m2、4000m2",{"key":24,"text":227,"correct":22},"4000m2、4000m2",{"key":27,"text":229,"correct":22},"4000m2、5000m2",{"key":31,"text":231,"correct":22},"5000m2、5000m2",{"id":233,"libraryId":5,"type":114,"typeLabel":115,"stem":234,"options":235,"answer":20,"analysis":37},935549,"中庭是指建筑室内无楼板分隔，上下敞开相连通的建筑内部空间。中庭与周围连通空间的防火分隔措施有多种，当采用防火隔墙时，耐火极限不低于（ ）h。",[236,238,240,242],{"key":20,"text":237,"correct":29},"1．00",{"key":24,"text":239,"correct":22},"2．00",{"key":27,"text":241,"correct":22},"2．50",{"key":31,"text":243,"correct":22},"3．00",{"id":245,"libraryId":5,"type":114,"typeLabel":115,"stem":246,"options":247,"answer":27,"analysis":37},935550,"在对某住宅楼进行检查时，调阅相关图纸资料得知，该楼为钢筋混凝土框架结构，柱、梁、楼板的设计耐火极限分别为3．00h、2．00h、1．00h，每层划分为2个防火分区。下列检查结果中，不符合现行国家消防技术标准的是（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"将内走廊上原设计的常闭式甲级防火门改为常开式甲级防火门",{"key":24,"text":251,"correct":22},"一层的防火墙设置在框架上，框架的耐火极限比防火墙的高",{"key":27,"text":253,"correct":29},"天然气管道穿过防火墙",{"key":31,"text":255,"correct":22},"排烟防火阀处于开启状态，但能遇火灾报警系统联动和现场手动关闭",{"id":257,"libraryId":5,"type":114,"typeLabel":115,"stem":258,"options":259,"answer":24,"analysis":37},935551,"卷帘式挡烟垂壁挡烟部件由两块或两块以上织物缝制时，搭接宽度不得小于（ ）mm。",[260,262,264,266],{"key":20,"text":261,"correct":22},"10",{"key":24,"text":263,"correct":29},"20",{"key":27,"text":265,"correct":22},"30",{"key":31,"text":267,"correct":22},"40",{"id":269,"libraryId":5,"type":114,"typeLabel":115,"stem":270,"options":271,"answer":31,"analysis":37},935552,"防火墙的耐火极限一般要求为3．00h，对甲、乙类厂房和甲、乙、丙类仓库，因发生火灾时延续时间较长，燃烧过程中所释放的热量较大，用于防火分区分隔的防火墙耐火极限应保持不低于（ ）h。",[272,273,274,276],{"key":20,"text":239,"correct":22},{"key":24,"text":243,"correct":22},{"key":27,"text":275,"correct":22},"5．00",{"key":31,"text":277,"correct":29},"4．00",{"id":279,"libraryId":5,"type":114,"typeLabel":115,"stem":280,"options":281,"answer":31,"analysis":37},935553,"某小区物业对小区住宅楼防火门窗安装质量进行检查，其中钢质防火门门框内充填水泥砂浆，门框与墙体采用预埋钢件或膨胀螺栓等连接牢固，固定点间距不宜大于（ ）mm。",[282,284,286,288],{"key":20,"text":283,"correct":22},"300",{"key":24,"text":285,"correct":22},"400",{"key":27,"text":287,"correct":22},"500",{"key":31,"text":289,"correct":29},"600",{"id":291,"libraryId":5,"type":114,"typeLabel":115,"stem":292,"options":293,"answer":24,"analysis":37},935554,"防烟分区如果面积过大，会使烟气波及面积扩大，增加受灾面，不利于安全疏散和扑救；如果面积过小，不仅影响使用，还会提高工程造价。下列关于防烟分区划分的做法中，不符合国家相关技术标准要求的是（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":22},"净空高度为5 m的商城，最大防烟分区的面积为800m2",{"key":24,"text":297,"correct":29},"净空高度为2．9 m的办公楼，最大防烟分区的面积为600m2",{"key":27,"text":299,"correct":22},"净空高度为7 m的丁类厂房，最大防烟分区的面积为1 600m2",{"key":31,"text":301,"correct":22},"净空高度为6 m的会议室，最大防烟分区的面积为1000m2",{"id":303,"libraryId":5,"type":114,"typeLabel":115,"stem":304,"options":305,"answer":31,"analysis":37},935555,"某购物中心，地下2层，地上5层，建筑面积为35000m2，用防火墙对该建筑进行防火分区分隔。检查过程中，不符合规范要求的设置是（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"防火墙可直接设置在建筑的钢筋混凝土框架上",{"key":24,"text":309,"correct":22},"防火墙设置在从楼地面基层至梁的底面基层",{"key":27,"text":311,"correct":22},"当防火墙设置在转角，内转角两侧墙上设置乙级防火窗，两侧防火窗之间最近边缘水平距离为1m",{"key":31,"text":313,"correct":29},"当防火墙设置在转角，内转角两侧墙上设置普通窗户，两侧窗户之间最近边缘水平距离为3m",{"id":315,"libraryId":5,"type":114,"typeLabel":115,"stem":316,"options":317,"answer":31,"analysis":37},935556,"某地下一层商场总面积为48000m2，使用防火隔间划分为三个面积不超过20000m2的区域，在检查防火隔间设置的过程中，不正确的做法是（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":22},"防火隔间内部装修材料的燃烧性能等级应为A级",{"key":24,"text":321,"correct":22},"防火隔间的建筑面积为6．0m2",{"key":27,"text":323,"correct":22},"不同防火分区通向防火隔间的门的最小间距为4m",{"key":31,"text":325,"correct":29},"防火隔间墙采用耐火极限不低于3．00h的防火隔墙，门采用乙级防火门",{"id":327,"libraryId":5,"type":114,"typeLabel":115,"stem":328,"options":329,"answer":27,"analysis":37},935557,"某地上6层办公大楼，层高4m，每层划分为两个防火分区，当每个防火分区的通风、空气调节系统均独立设置时，该系统风管穿过建筑的哪个部位可不设置防火阀（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"穿越防火分区处",{"key":24,"text":333,"correct":22},"穿越防火分隔处的变形缝两侧",{"key":27,"text":335,"correct":29},"水平风管与竖向总管的交接处",{"key":31,"text":337,"correct":22},"穿越通风、空气调节机房的房间隔墙处",{"id":339,"libraryId":5,"type":114,"typeLabel":115,"stem":340,"options":341,"answer":20,"analysis":37},935558,"某高层建筑首层为商场，二层至十二层为办公，地下一层为汽车库，地下二层部分为汽车库，其余部分为设备区，室内全部采用不燃材料装修，设有自动喷水灭火系统和火灾自动报警系统。下列关于该建筑商场及设备区防火分区最大允许建筑面积的说法，正确的是（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":29},"商场营业厅4000m2；设备区2000m2",{"key":24,"text":345,"correct":22},"商场营业厅4000m2；设备区1000m2",{"key":27,"text":347,"correct":22},"商场营业厅10000m2；设备区2000m2",{"key":31,"text":349,"correct":22},"商场营业厅3000m2；设备区1000m2",{"id":351,"libraryId":5,"type":114,"typeLabel":115,"stem":352,"options":353,"answer":31,"analysis":37},935559,"对地下大型建筑防火隔间进行防火检查时，下列检查结果不符合现行国家消防技术标准的是（ ）。",[354,356,357,359],{"key":20,"text":355,"correct":22},"防火隔间的建筑面积为6m2",{"key":24,"text":203,"correct":22},{"key":27,"text":358,"correct":22},"防火隔间地面装修材料采用陶瓷砖",{"key":31,"text":360,"correct":29},"防火隔间内设置休息点",{"id":362,"libraryId":5,"type":114,"typeLabel":115,"stem":363,"options":364,"answer":24,"analysis":37},935560,"某独立建造的单层橡胶手套存储仓库，耐火等级为二级，占地面积2000m2，下列检查结果中，不符合现行国家消防技术标准的是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"仓库内设有员工休息室，采用2．50h的防火隔墙与其他部位分隔，隔墙上开乙级防火门，设有独立的安全出口",{"key":24,"text":368,"correct":29},"采用耐火极限为3．00h的防火墙平均划分为两个防火分区",{"key":27,"text":370,"correct":22},"防火分区之间的防火墙上因作业需要，开设甲级防火门，净宽和净高均为3．5m",{"key":31,"text":372,"correct":22},"防火墙直接从建筑的基层隔断至主梁的底面基层",{"id":374,"libraryId":5,"type":114,"typeLabel":115,"stem":375,"options":376,"answer":27,"analysis":37},935561,"在对设置排烟系统的建筑进行防烟分区检查时，应注意划分防烟分区的构件材质。下列构件不能划分防烟分区的是（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":22},"防火卷帘",{"key":24,"text":380,"correct":22},"防火隔墙",{"key":27,"text":382,"correct":29},"采用5mm厚普通玻璃制作的挡烟垂壁",{"key":31,"text":384,"correct":22},"高度为600mm的结构梁",{"id":386,"libraryId":5,"type":114,"typeLabel":115,"stem":387,"options":388,"answer":31,"analysis":37},935562,"对某设有顶棚的步行街进行防火检查，检查结果如下，其中不符合规范要求的是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":22},"步行街两侧建筑的商铺外每隔25m设置DN65的消火栓，并配备消防软管卷盘",{"key":24,"text":392,"correct":22},"步行街两侧建筑的商铺内外均设有疏散照明、灯光疏散指示标志和消防应急广播系统",{"key":27,"text":394,"correct":22},"步行街两侧建筑的商铺之间设置耐火极限为2．50h的防火隔墙",{"key":31,"text":396,"correct":29},"步行街的顶棚下檐距地面的高度为5．0m，顶棚采用常开式的排烟口，自然排烟口的有效面积为步行街地面面积的20％",{"id":398,"libraryId":5,"type":114,"typeLabel":115,"stem":399,"options":400,"answer":24,"analysis":37},935563,"某二级耐火等级的多层民用建筑，地上4层，地下2层，首层至三层为商店营业厅，四层为餐饮场所，地下一层为网吧，地下二层为设备用房，建筑内部装修全部采用不燃和难燃材料制作，设有自动喷水灭火系统和火灾自动报警系统。下列关于该建筑内各场所防火分区最大允许建筑面积的说法，正确的是（ ）。",[401,403,405,406],{"key":20,"text":402,"correct":22},"商场营业厅4000m2；网吧2000m2",{"key":24,"text":404,"correct":29},"商场营业厅5000m2；网吧1000m2",{"key":27,"text":347,"correct":22},{"key":31,"text":345,"correct":22},{"id":408,"libraryId":5,"type":114,"typeLabel":115,"stem":409,"options":410,"answer":24,"analysis":37},935564,"某带顶棚的地上 2 层步行街，总长度为 220m ，步行街两侧商铺之间的防火间距均为 10ｍ。下列说法中，错误的是（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":22},"步行街两侧建筑的耐火等级不应低于二级",{"key":24,"text":414,"correct":29},"步行街内最不利点一点到达最近室外安全地点的直线距离不应大于 60m",{"key":27,"text":416,"correct":22},"步行街顶棚采用难燃材料制成，其承重结构的耐火极限为 1.00h",{"key":31,"text":418,"correct":22},"该步行街顶棚设置的自然排烟口的有效面积不应小于 550 ㎡",{"id":420,"libraryId":5,"type":114,"typeLabel":115,"stem":421,"options":422,"answer":31,"analysis":37},935565,"某单层松节油仓库，耐火等级二级，占地面积为 2000 ㎡，其柱的耐火极限不应低于（ ）h。",[423,425,427,429],{"key":20,"text":424,"correct":22},"3.50",{"key":24,"text":426,"correct":22},"3.00",{"key":27,"text":428,"correct":22},"2.50",{"key":31,"text":430,"correct":29},"2.00",{"id":432,"libraryId":5,"type":114,"typeLabel":115,"stem":433,"options":434,"answer":27,"analysis":37},935566,"建筑的电缆井、管道井、排（气）烟道、垃圾道等竖向井道，井壁上的检查门为（ ）防火门。",[435,437,439,441],{"key":20,"text":436,"correct":22},"甲级",{"key":24,"text":438,"correct":22},"乙级",{"key":27,"text":440,"correct":29},"丙级",{"key":31,"text":442,"correct":22},"丁级",{"id":444,"libraryId":5,"type":114,"typeLabel":115,"stem":445,"options":446,"answer":20,"analysis":37},935567,"下列关于防烟分区的划分说法错误的是（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":29},"防烟分区可以跨越防火分区设置",{"key":24,"text":450,"correct":22},"有特殊用途的场所，如地下室、防烟楼梯间、消防电梯、避难层间等，必须独立划分防烟分区",{"key":27,"text":452,"correct":22},"当空间净高大于9m 时，防烟分区之间可以不设挡烟设施",{"key":31,"text":454,"correct":22},"设置排烟设施的建筑内，敞开楼梯穿越楼板的开口部位应设置挡烟垂壁",{"id":456,"libraryId":5,"type":114,"typeLabel":115,"stem":457,"options":458,"answer":24,"analysis":37},935568,"对建筑物的变形缝进行防火检查中，当通风、空气调节系统的风管穿越防火分隔处的变形缝时，应检查其两侧是否设置公称动作温度为（ ）℃的防火阀。",[459,461,463,465],{"key":20,"text":460,"correct":22},"75",{"key":24,"text":462,"correct":29},"70",{"key":27,"text":464,"correct":22},"65",{"key":31,"text":466,"correct":22},"60",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":481,"analysis":37},935569,"下列工业建筑中，划分防火分区的防火墙不可以采用防火卷帘或防火水幕替代的有（ ）。",[471,473,475,477,479],{"key":20,"text":472,"correct":29},"三级耐火等级的沥青、石蜡仓库",{"key":24,"text":474,"correct":29},"二级耐火等级的次氯酸钙生产厂房",{"key":27,"text":476,"correct":29},"二级耐火等级的硝酸铵仓库",{"key":31,"text":478,"correct":22},"二级耐火等级的松香提炼厂房",{"key":34,"text":480,"correct":29},"二级耐火等级的赛璐珞厂房","ABCE",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":496,"analysis":37},935570,"某消防服务机构对建筑面积为30000m2的大型地下商场进行安全评估，在对防火隔间进行检查时发现，防火分区通向防火隔间的门为乙级防火门，两个乙级防火门的间距为4m，隔间的装修为轻钢龙骨石膏板吊顶，阻燃壁纸装饰墙面，隔间内有几位顾客坐在座椅上休息。根据现行国家消防技术标准，该防火隔间不符合标准规定的有（ ）。",[486,488,490,492,494],{"key":20,"text":487,"correct":29},"防火隔间的门为乙级防火门",{"key":24,"text":489,"correct":22},"采用轻钢龙骨石膏板吊顶",{"key":27,"text":491,"correct":29},"设置供人员休息用的座椅",{"key":31,"text":493,"correct":22},"不同防火分区开向防火隔间门的距离为4m",{"key":34,"text":495,"correct":29},"采用阻燃壁纸装饰墙面","ACE",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":82,"analysis":37},935571,"对某金属加工厂的抛光车间进行防火检查，查阅资料得知，该车间耐火等级为一级，防火分区划分符合规范要求。该车间的下列做法中，符合现行国家消防技术标准要求的有（ ）。",[501,503,505,507,509],{"key":20,"text":502,"correct":29},"位于一层的丙类液体储罐间，采用防火墙和耐火极限为1．50h的楼板与其他部分分隔，墙上的门为甲级防火门",{"key":24,"text":504,"correct":22},"为全厂服务的配电站贴邻该车间建造，采用防火墙与车间分隔，墙上的门为甲级防火门",{"key":27,"text":506,"correct":22},"设在车间一层内的办公室采用耐火极限为3．00h的防爆墙与车间分隔，并设有独立的安全出口",{"key":31,"text":508,"correct":29},"地上二层因生产需要，在防火分区之间采用符合规定的防火卷帘分隔",{"key":34,"text":510,"correct":22},"位于车间三层的总控制室采用防火墙和耐火极限1．50h的楼板与其他部分分隔，且设有独立使用的防烟楼梯间…",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":496,"analysis":37},935572,"某一级耐火等级商业综合体，层高5m（室内净空高4．5m），地上6层，每层建筑面积为6000m2，地下2层，每层建筑面积为8000m2。首层为商场，二层及以上使用性质有餐饮、少儿培训、电影院等，地下一层设有KTV（建筑面积2000m2），部分为汽车库，地下二层为汽车库，部分为设备间，内部装修全部采用不燃材料，设有自动喷水灭火系统和火灾自动报警系统。下列关于该建筑防火分区和防烟分区的说法，正确的是（ ）。",[515,517,519,521,523],{"key":20,"text":516,"correct":29},"该建筑首层至少应划分为两个防火分区",{"key":24,"text":518,"correct":22},"该建筑地上二层至少应划分为3个防火分区",{"key":27,"text":520,"correct":29},"该建筑地上每层至少应划分6个防烟分区",{"key":31,"text":522,"correct":22},"该建筑地下KTV部分至少应划分为1个防火分区",{"key":34,"text":524,"correct":29},"该建筑地下二层至少应划分为4个防烟分区",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":539,"analysis":37},935573,"下列关于防烟分区划分的叙述中，正确的是（ ）。",[529,531,533,535,537],{"key":20,"text":530,"correct":29},"防烟分区一般结合建筑内部的功能分区和排烟系统的设置，按其用途、面积、楼层划分",{"key":24,"text":532,"correct":29},"防烟分区不得跨越防火分区",{"key":27,"text":534,"correct":29},"不设排烟设施的部位（包括地下室）可不划分防烟分区",{"key":31,"text":536,"correct":22},"防烟分区的长边一般不大于75m",{"key":34,"text":538,"correct":22},"当室内高度超过6m且具有自然对流条件时，长边可不大于75m","ABC",{"id":541,"libraryId":5,"type":114,"typeLabel":115,"stem":542,"options":543,"answer":31,"analysis":37},935574,"某多层仓库耐火等级为二级，占地面积1800㎡，仓库内存放有动物油500L，酚醛泡沫塑料200kg，钢材2t，该仓库防火分区建筑面积最大可为（ ）㎡。",[544,545,546,547],{"key":20,"text":131,"correct":22},{"key":24,"text":195,"correct":22},{"key":27,"text":135,"correct":22},{"key":31,"text":133,"correct":29},{"id":549,"libraryId":5,"type":114,"typeLabel":115,"stem":550,"options":551,"answer":20,"analysis":37},935575,"某综合楼，耐火等级为一级，地上6层，地下2层，层高4．3m，每层建筑面积8000㎡，首层为商场营业厅，二层设有电影院，三层设有餐饮场所，四层设有网吧，地下一层为超市，地下二层设有设备用房，内部装修材料全部采用不燃材料，设有自动喷水灭火系统和火灾自动报警系统保护，消防机构对该综合楼进行防火检查，下列结果，不符合现行国家技术标准的是（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":29},"首层划分为1个防火分区",{"key":24,"text":555,"correct":22},"地下二层划分为4个防火分区",{"key":27,"text":557,"correct":22},"第三层划分为3个防火分区",{"key":31,"text":559,"correct":22},"地下一层划分8个防火分区",{"id":561,"libraryId":5,"type":114,"typeLabel":115,"stem":562,"options":563,"answer":24,"analysis":37},935576,"某单层地下建材仓库，建筑面积为480㎡，储存有壁纸，岩棉吸声板等，按规范要求配置消防设施，该地下建材仓库至少应划分为（ ）个防火分区。",[564,566,568,570],{"key":20,"text":565,"correct":22},"1",{"key":24,"text":567,"correct":29},"2",{"key":27,"text":569,"correct":22},"3",{"key":31,"text":571,"correct":22},"4",{"id":573,"libraryId":5,"type":114,"typeLabel":115,"stem":574,"options":575,"answer":24,"analysis":37},935577,"消防机构对某高层商场的中庭进行检查，下列检查结果中，不符合规范要求的是（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":22},"中庭设置了排烟设施",{"key":24,"text":579,"correct":29},"中庭回廊仅设置了自动喷水灭火系统",{"key":27,"text":581,"correct":22},"中庭的顶棚采用石膏板进行装修",{"key":31,"text":583,"correct":22},"中庭的地面采用水泥木丝板进行装修",{"id":585,"libraryId":5,"type":114,"typeLabel":115,"stem":586,"options":587,"answer":24,"analysis":37},935578,"根据《建筑内部装修设计防火规范》（GB 50222），对不同建筑防烟楼梯间前室进行检查时，不符合规范要求的做法是（ ）。",[588,590,592,594],{"key":20,"text":589,"correct":22},"高层办公楼防烟楼梯间使用面积为6 m2",{"key":24,"text":591,"correct":29},"商场大楼防烟楼梯间建筑面积为6 m2",{"key":27,"text":593,"correct":22},"五层住宅楼防烟楼梯间使用面积为5 m2",{"key":31,"text":595,"correct":22},"高层厂房合用防烟楼梯间使用面积为11 m2",{"id":597,"libraryId":5,"type":114,"typeLabel":115,"stem":598,"options":599,"answer":20,"analysis":37},935579,"建筑幕墙是由金属构件和玻璃板等组成的建筑物外围护结构，建筑幕墙外立面开口之间的防火设置不符合规范要求的做法是（ ）。",[600,602,604,606],{"key":20,"text":601,"correct":29},"无自动喷水灭火系统下，设置耐火极限为1．0 h的不燃性实体墙，不燃性实体墙高度为1．0 m",{"key":24,"text":603,"correct":22},"无自动喷水灭火系统下，设置耐火完整性为1．0 h的防火玻璃墙，防火玻璃墙高度为1．2 m",{"key":27,"text":605,"correct":22},"室内设置自动喷水灭火系统，防火玻璃墙高度为0．8m",{"key":31,"text":607,"correct":22},"室内设置自动喷水灭火系统，不燃性实体墙高度为0．8 m",{"id":609,"libraryId":5,"type":114,"typeLabel":115,"stem":610,"options":611,"answer":24,"analysis":37},935580,"对挡烟垂壁进行检查时，需要注意搭接宽度，下列情况中不符合相关要求的是（ ）。",[612,614,616,618],{"key":20,"text":613,"correct":22},"卷帘式挡烟垂壁挡烟部件由两块或两块以上织物缝制，搭接宽度为30 mm",{"key":24,"text":615,"correct":29},"采用多节垂壁搭接的形式使用，卷帘式挡烟垂壁的搭接宽度为80 mm",{"key":27,"text":617,"correct":22},"翻板式挡烟垂壁的搭接宽度为20 mm",{"key":31,"text":619,"correct":22},"宽度测量值的允许负偏差为规定值的4％",{"id":621,"libraryId":5,"type":114,"typeLabel":115,"stem":622,"options":623,"answer":31,"analysis":37},935581,"某单层白酒仓库，占地面积900 m2。库房内未进行防火分隔，未设置自动灭火和火灾自动报警设施，储存陶坛装酒精度为38°及以上的白酒。防火检查时提出的下列防火分区的处理措施中正确的是（ ）。",[624,626,628,630],{"key":20,"text":625,"correct":22},"将该仓库作为一个防火分区，同时设置自动灭火系统和火灾自动报警系统",{"key":24,"text":627,"correct":22},"将该仓库用耐火极限为4．00 h的防火墙平均分成4个防火分区，并设置火灾自动报警系统",{"key":27,"text":629,"correct":22},"将该仓库用耐火极限为3．00 h且满足耐火完整性和耐火隔热性判定条件的防火卷帘划分为5个防火分区，最大防火分区面积不超过200 m2",{"key":31,"text":631,"correct":29},"将该仓库用耐火极限为4．00 h的防火墙平均分成2个防火分区，并设置火灾自动灭火系统",{"id":633,"libraryId":5,"type":114,"typeLabel":115,"stem":634,"options":635,"answer":31,"analysis":37},935582,"对某地下商场的避难走道进行防火检查，查阅资料得知，该商场耐火等级为一级，防火分区划分符合规范要求。下列检查结果中，不符合现行国家消防技术标准要求的有（ ）。",[636,638,640,642],{"key":20,"text":637,"correct":22},"避难走道防火隔墙的耐火极限为3．00h，楼板的耐火极限为1．50h",{"key":24,"text":639,"correct":22},"避难走道内部装修材料采用天然石材",{"key":27,"text":641,"correct":22},"防火分区至避难走道入口处应设置防烟前室，前室的使用面积为8．0m2",{"key":31,"text":643,"correct":29},"开向前室的门采用乙级防火门",[645,648,651,654,657,660],{"id":114,"name":646,"category":7,"favorite":647},"领导干部任职前廉政法规知识测试题",92,{"id":649,"name":650,"category":7,"favorite":114},595,"建筑结构与设备",{"id":652,"name":653,"category":7,"favorite":114},715,"招标采购专业知识与法律法规",{"id":655,"name":656,"category":7,"favorite":114},848,"市政方向-通用基础",{"id":658,"name":659,"category":7,"favorite":8},534,"BIM工程师",{"id":661,"name":659,"category":7,"favorite":8},535]