[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":651},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,14,50,2974,[13,34,46,58,76,91,106,121,133,145,157,169,181,193,205,217,229,241,253,261,276,291,306,321,336,348,360,372,384,396,408,420,432,444,456,468,483,498,512,524,536,548,559,571,582,594,608,619,631,642],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},935333,1,"单选题","下列各消防安全职责中，属于消防安全重点单位特有的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","对建筑消防设施每年至少进行一次全面检测，确保完好有效",false,{"key":24,"text":25,"correct":22},"B","按照国家标准、行业标准配置消防设施、器材，设置消防安全标志",{"key":27,"text":28,"correct":29},"C","对职工进行岗前消防安全培训，定期组织消防安全培训和消防演练",true,{"key":31,"text":32,"correct":22},"D","组织防火检查，及时消除火灾隐患","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},935334,"公众聚集场所对员工的消防安全培训应当至少每（ ）进行一次。",[38,40,42,44],{"key":20,"text":39,"correct":22},"年",{"key":24,"text":41,"correct":29},"半年",{"key":27,"text":43,"correct":22},"季度",{"key":31,"text":45,"correct":22},"月",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},935335,"下列属于消防安全管理人的消防安全管理职责的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"将消防工作与本单位的生产、科研、经营、管理等活动统筹安排，批准实施年度消防工作计划",{"key":24,"text":53,"correct":22},"为本单位的消防安全提供必要的经费和组织保障",{"key":27,"text":55,"correct":29},"在员工中组织开展消防知识、技能的宣传教育和培训，组织灭火和应急疏散预案的实施和演练",{"key":31,"text":57,"correct":22},"组织防火检查，督促落实火灾隐患整改，及时处理涉及消防安全的重大问题",{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":75,"analysis":33},935336,2,"多选题","《中华人民共和国建筑法》规定，工程监理单位与被监理工程的承包单位以及（）单位不得有隶属关系或者其他利害关系。",[64,66,68,70,72],{"key":20,"text":65,"correct":22},"施工单位",{"key":24,"text":67,"correct":29},"建筑材料",{"key":27,"text":69,"correct":29},"建筑构配件",{"key":31,"text":71,"correct":29},"设备供应",{"key":73,"text":74,"correct":22},"E","财务部门","BCD",{"id":77,"libraryId":5,"type":60,"typeLabel":61,"stem":78,"options":79,"answer":90,"analysis":33},935337,"下列关于公共娱乐场所安全管理的说法中，正确的有（）。",[80,82,84,86,88],{"key":20,"text":81,"correct":29},"公共娱乐场所内严禁带入和存放易燃、易爆物品",{"key":24,"text":83,"correct":22},"严禁在公共娱乐场所营业时进行设备调试作业",{"key":27,"text":85,"correct":29},"严禁在公共娱乐场所营业时进行电气焊作业、油漆粉刷作业",{"key":31,"text":87,"correct":22},"演出、放映场所的观众厅内禁止吸烟，但可以明火照明。",{"key":73,"text":89,"correct":29},"公共娱乐场所在营业时，不得超过额定人数","ACE",{"id":92,"libraryId":5,"type":60,"typeLabel":61,"stem":93,"options":94,"answer":105,"analysis":33},935338,"听证程序只适用于行政机关作出（）等行政处罚。",[95,97,99,101,103],{"key":20,"text":96,"correct":29},"较大数额罚款",{"key":24,"text":98,"correct":22},"警告",{"key":27,"text":100,"correct":29},"责令停产停业",{"key":31,"text":102,"correct":29},"吊销许可证或者执照",{"key":73,"text":104,"correct":22},"罚款","ACD",{"id":107,"libraryId":5,"type":60,"typeLabel":61,"stem":108,"options":109,"answer":120,"analysis":33},935339,"下列违法行为中，应责令停止施工、停止使用或者停产停业，并处一万元以上十万元以下罚款的有（ ）。",[110,112,114,116,118],{"key":20,"text":111,"correct":22},"消防设计经公安机关消防机构依法抽查不合格，不停止施工的",{"key":24,"text":113,"correct":29},"建筑施工企业不按照消防设计文件和消防技术标准施工，降低消防施工质量的",{"key":27,"text":115,"correct":22},"建设工程投入使用后经公安机关消防机构依法抽查不合格，不停止使用的",{"key":31,"text":117,"correct":22},"公众聚集场所未经消防安全检查或者经检查不符合消防安全要求，擅自投入使用、营业的",{"key":73,"text":119,"correct":29},"工程监理单位与建设单位或者建筑施工企业串通，弄虚作假，降低消防施工质量的","BE",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":27,"analysis":33},935340,"建筑高度大于（ ）m的住宅建筑和其他建筑高度大于24m的非单层建筑属于高层建筑。",[125,127,129,131],{"key":20,"text":126,"correct":22},"25",{"key":24,"text":128,"correct":22},"26",{"key":27,"text":130,"correct":29},"27",{"key":31,"text":132,"correct":22},"28",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":27,"analysis":33},935341,"某民用建筑，底部设有3个便民服务点，分别为理发店（280㎡），小商店（150㎡，邮政所（310㎡），室外设计地面至平屋面和女儿墙的高度分别为53．6m、54．4m，则该建筑为（ ）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"一类高层住宅建筑",{"key":24,"text":140,"correct":22},"二类高层住宅建筑",{"key":27,"text":142,"correct":29},"一类高层公共建筑",{"key":31,"text":144,"correct":22},"二类高层公共建筑",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":31,"analysis":33},935342,"某组合式公共建筑，建筑的三部分 A、 B、C分别位于不同地坪高度上，且建筑之间均用防火墙分隔，各自有符合规范规定的安全出口， A、 B、C的高度分别为22m、23m、25m，下列说法中正确的是（ ）。",[149,151,153,155],{"key":20,"text":150,"correct":22},"建筑B的建筑高度为23m",{"key":24,"text":152,"correct":22},"可分别确定各自的建筑高度",{"key":27,"text":154,"correct":22},"建筑A为单、多层公共建筑",{"key":31,"text":156,"correct":29},"应按建筑高度最大的，确定该组合建筑总高度",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":27,"analysis":33},935343,"某建筑地上18层，每层建筑面积为1000㎡，首层至三层划分为200～320㎡的小商铺，建筑四层至十八层为住宅，每层建筑面积为1000㎡，建筑屋面为平屋面，局部突出屋顶的辅助用房面积为250㎡，高度为4m。建筑室外设计地面标高为-0．3m，首层室内地面标高为±0．0m，屋面面层的标高为49．8m，下列关于该建筑的说法正确的是（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":22},"该建筑为一类高层住宅建筑",{"key":24,"text":164,"correct":22},"该建筑为二类高层公共建筑",{"key":27,"text":166,"correct":29},"该建筑为一类高层公共建筑",{"key":31,"text":168,"correct":22},"该建筑为二层高层住宅建筑",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":27,"analysis":33},935344,"下列建筑中，按照建筑分类属于一类高层公共建筑的是（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"建筑高度24m的医疗建筑",{"key":24,"text":176,"correct":22},"室外设计地面标高为0．2m，屋面面层的标高为24m的市级党政机关办公大楼",{"key":27,"text":178,"correct":29},"建筑高度为30m综合楼，标准层建筑面积1100m2的建筑，层高为5m，首层至三层为商业，四层至六层为办公室",{"key":31,"text":180,"correct":22},"建筑高度25m，层高5m，标准层建筑面积为1100m2的商场",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":27,"analysis":33},935345,"某二级耐火等级的单层木器厂房，建筑面积10000㎡，设有一间建筑面积450㎡的喷漆间，以及一间建筑面积50㎡的中间仓库（储存有甲苯稀释剂和油漆），并按规定采取有效的防火分隔，该厂房的火灾危险性为（ ）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"甲类",{"key":24,"text":188,"correct":22},"乙类",{"key":27,"text":190,"correct":29},"丙类",{"key":31,"text":192,"correct":22},"丁类",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":27,"analysis":33},935346,"以下关于工业建筑耐火等级的说法中，正确的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"地上2层的重油仓库耐火等级最低为三级",{"key":24,"text":200,"correct":22},"占地面积不大于300㎡的甲类仓库，耐火等级最低为三级",{"key":27,"text":202,"correct":29},"高架仓库耐火等级不应低于二级",{"key":31,"text":204,"correct":22},"单层中药仓库耐火等级最低为四级",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":31,"analysis":33},935347,"下列关于建筑层数和耐火等级的说法，不正确的是（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"甲类仓库最多允许建造单层",{"key":24,"text":212,"correct":22},"乙类厂房的耐火等级为一级时，其层数可不限",{"key":27,"text":214,"correct":22},"建筑面积为500㎡，使用丙类液体的单层丙类厂房，其耐火等级可为三级",{"key":31,"text":216,"correct":29},"某独立建造的电影院耐火等级为三级时，其层数最多为3层",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":31,"analysis":33},935348,"在对住宅建筑高度和建筑层数进行检查时，错误的做法是（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"局部凸出屋顶的瞭望塔、冷却塔等辅助用房占屋面面积为1／5时，不计入建筑高度",{"key":24,"text":224,"correct":22},"室内顶板面高出室外设计地面的高度为1．3 m的半地下室不计入建筑层数",{"key":27,"text":226,"correct":22},"建筑底部设置的室内高度为2 m的自行车库不计入建筑层数",{"key":31,"text":228,"correct":29},"对于台阶式地坪，建筑高度都按其中建筑高度最大者确定",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":31,"analysis":33},935349,"某住宅建筑的屋面为坡屋面，首层室内地面标高为±0.0m，室外设计地面标高为-0.6m，室外设计地面至檐口和屋脊的高度分别为49.8m和52.6m。则该住宅建筑的高度为（ ）m。",[233,235,237,239],{"key":20,"text":234,"correct":22},"49.8",{"key":24,"text":236,"correct":22},"52.6",{"key":27,"text":238,"correct":22},"51.2",{"key":31,"text":240,"correct":29},"50.6",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":31,"analysis":33},935350,"某单层渣油仓库，耐火等级二级，占地面积为2000m2，其柱、梁的耐火极限分别不应低于（ ）h。",[245,247,249,251],{"key":20,"text":246,"correct":22},"2．50、2．00",{"key":24,"text":248,"correct":22},"2．00、2．00",{"key":27,"text":250,"correct":22},"2．50、2．50",{"key":31,"text":252,"correct":29},"2．00、1．50",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":27,"analysis":33},935351,"仓库为丁戊类仓库，当可燃包装重量大于物品本身重量1／4或可燃包装体积大于物品本身体积的1／2时，按（ ）确定仓库的火灾危险性。",[257,258,259,260],{"key":20,"text":186,"correct":22},{"key":24,"text":188,"correct":22},{"key":27,"text":190,"correct":29},{"key":31,"text":192,"correct":22},{"id":262,"libraryId":5,"type":60,"typeLabel":61,"stem":263,"options":264,"answer":275,"analysis":33},935352,"下列民用建筑按照建筑高度和建筑层数分类，不属于高层建筑的是（ ）。",[265,267,269,271,273],{"key":20,"text":266,"correct":29},"建筑高度为27m，首层为商业服务网点的住宅建筑",{"key":24,"text":268,"correct":22},"地下一层至地上一层为超市，每层建筑面积350m2，地上二层及以上部分为住宅，建筑高度为27m的民用建筑",{"key":27,"text":270,"correct":29},"地下一层设有汽车库，建筑高度27m的住宅建筑",{"key":31,"text":272,"correct":29},"建筑高度27m的单层体育馆，附属建筑高度为24m，内部设有器材库和运动员休息室",{"key":73,"text":274,"correct":29},"建筑高度24m的市政府办公大楼","ACDE",{"id":277,"libraryId":5,"type":60,"typeLabel":61,"stem":278,"options":279,"answer":290,"analysis":33},935353,"下列建筑属于一类高层公共建筑的是（ ）。",[280,282,284,286,288],{"key":20,"text":281,"correct":22},"建筑高度为40m，层高3m，一至二层为商场，三层及以上为住宅，每层建筑面积均为1200㎡的建筑",{"key":24,"text":283,"correct":29},"建筑高度为32m的门诊楼",{"key":27,"text":285,"correct":22},"建筑高度为24m的学生宿舍，每层建筑面积均为1200㎡",{"key":31,"text":287,"correct":29},"建筑高度为40m的综合楼，地上8层，层高5m，使用性质为酒店和办公，每层建筑面积均为2600㎡",{"key":73,"text":289,"correct":22},"建筑高度为27m的商店建筑，地上9层，层高3m，每层建筑面积均为900㎡","BD",{"id":292,"libraryId":5,"type":60,"typeLabel":61,"stem":293,"options":294,"answer":305,"analysis":33},935354,"（ ）属于一类高层公共建筑。",[295,297,299,301,303],{"key":20,"text":296,"correct":29},"建筑高度为25m的医疗建筑",{"key":24,"text":298,"correct":22},"建筑高度为25m的藏书10万册的图书馆",{"key":27,"text":300,"correct":22},"建筑高度为24m的党政机关办公楼",{"key":31,"text":302,"correct":29},"建筑高度为54m且24m以上部分任一楼层建筑面积为1100㎡的多种功能组合的建筑",{"key":73,"text":304,"correct":22},"建筑高度为25m的5层办公建筑，每层建筑面积为1500㎡","AD",{"id":307,"libraryId":5,"type":60,"typeLabel":61,"stem":308,"options":309,"answer":320,"analysis":33},935355,"某新建的煤粉厂房，地上7层，层高3m，并采用自动灭火系统进行全保护。下列关于该厂房内建筑构件耐火极限的说法，正确的是（ ）。",[310,312,314,316,318],{"key":20,"text":311,"correct":22},"采用耐火极限为3．00h的防火墙",{"key":24,"text":313,"correct":29},"采用耐火极限为1．00h的屋顶承重构件",{"key":27,"text":315,"correct":29},"采用耐火极限为1．50h的楼板",{"key":31,"text":317,"correct":22},"采用耐火极限为2．50h的承重墙",{"key":73,"text":319,"correct":29},"采用耐火极限为1．50h的疏散楼梯","BCE",{"id":322,"libraryId":5,"type":60,"typeLabel":61,"stem":323,"options":324,"answer":335,"analysis":33},935356,"对厂房进行防爆检查时，应注意该厂房的性质和使用功能，其中下列厂房的管、沟不应与相邻厂房相通，且下水道应设置隔油设施的是（ ）。",[325,327,329,331,333],{"key":20,"text":326,"correct":29},"焦化厂的焦油厂房",{"key":24,"text":328,"correct":22},"氢气站",{"key":27,"text":330,"correct":29},"甲酚厂房",{"key":31,"text":332,"correct":22},"木器加工厂",{"key":73,"text":334,"correct":22},"空分厂房","AC",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":31,"analysis":33},935357,"按建筑使用性质，可分为民用建筑、工业建筑和（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"医疗建筑",{"key":24,"text":343,"correct":22},"军用建筑",{"key":27,"text":345,"correct":22},"仓储建筑",{"key":31,"text":347,"correct":29},"农业建筑",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":31,"analysis":33},935358,"下列选项中，属于建筑物的是（ ）。",[352,354,356,358],{"key":20,"text":353,"correct":22},"水塔",{"key":24,"text":355,"correct":22},"烟囱",{"key":27,"text":357,"correct":22},"堤坝",{"key":31,"text":359,"correct":29},"学校",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":20,"analysis":33},935359,"下列关于厂房火灾危险性分类的叙述中，错误的是（ ）。",[364,366,368,370],{"key":20,"text":365,"correct":29},"某2层木器厂房，一级耐火等级，首层建筑面积8000㎡，每层划分为一个防火分区其中喷漆间建筑面积为400㎡，该厂房火灾危险性为丙类",{"key":24,"text":367,"correct":22},"某2层木器厂房，一级耐火等级，首层建筑面积8000㎡，每层划分为一个防火分区其中油漆工段建筑面积为200㎡，采取了有效的防止火灾蔓延的措施，该厂房火灾危险性为丙类",{"key":27,"text":369,"correct":22},"某单层车辆装配车间，一级耐火等级，建筑面积为8000㎡，每层划分为一个防火分区其中油漆工段建筑面积为750㎡，且采取了有效的防止火灾蔓延的措施，则其火灾危险性为戊类",{"key":31,"text":371,"correct":22},"某单层车辆装配厂房，一级耐火等级，建筑面积为8000㎡，每层划分为一个防火分区其中油漆工段建筑面积为1600㎡，采用封闭喷漆工艺，封闭喷漆空间内保持负压，油漆工段设置可燃气体探测报警系统或自动抑爆系统，则其火灾危险性为戊类",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":20,"analysis":33},935360,"下列工业建筑中，可以采用三级耐火等级的是（ ）。",[376,378,380,382],{"key":20,"text":377,"correct":29},"建筑面积为1000㎡的单层转炉厂房",{"key":24,"text":379,"correct":22},"建筑面积为500㎡氨压缩机房",{"key":27,"text":381,"correct":22},"蒸发量为5t／h的燃煤锅炉房",{"key":31,"text":383,"correct":22},"建筑面积为500㎡的地上2层植物油加工厂的精炼部位",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":27,"analysis":33},935361,"某煤油仓库，耐火等级为一级，则其最多允许数为（ ）。",[388,390,392,394],{"key":20,"text":389,"correct":22},"不限",{"key":24,"text":391,"correct":22},"6层",{"key":27,"text":393,"correct":29},"3层",{"key":31,"text":395,"correct":22},"5层",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":24,"analysis":33},935362,"某单层水泥厂轮窑厂房，因生产需要在厂房靠外墙的位置设置了一座甲类液体中间仓库，其储量不超过1昼夜的需要量，则厂房最低可采用（ ）耐火等级。",[400,402,404,406],{"key":20,"text":401,"correct":22},"三级",{"key":24,"text":403,"correct":29},"二级",{"key":27,"text":405,"correct":22},"一级",{"key":31,"text":407,"correct":22},"四级",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":20,"analysis":33},935363,"对厂房和仓库进行耐火等级检查时，符合规范要求的是（ ）。",[412,414,416,418],{"key":20,"text":413,"correct":29},"储存精密实验仪器的仓库，其耐火等级不应低于二级",{"key":24,"text":415,"correct":22},"粮食筒仓的耐火等级为三级",{"key":27,"text":417,"correct":22},"某燃煤锅炉房锅炉的总蒸发量为6 t／h，锅炉房耐火等级为三级",{"key":31,"text":419,"correct":22},"建筑面积为380m2的独立乙类单层厂房耐火等级为三级",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":27,"analysis":33},935364,"甲市、乙市和丙市曾先后发生过3起建筑火灾坍塌事故，建筑分别在火灾发生后115min、196min、537min时坍塌。坍塌建筑的底部或底部数层均为钢筋混凝土框架结构、上部均为砖混结构。事实上，下列建筑结构中，耐火性能相对较低的是（ ）。",[424,426,428,430],{"key":20,"text":425,"correct":22},"砖混结构",{"key":24,"text":427,"correct":22},"钢筋混凝土结构",{"key":27,"text":429,"correct":29},"钢结构",{"key":31,"text":431,"correct":22},"钢筋混凝土排架结构",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},935365,"下列关于工业建筑的层数和耐火等级的说法中，错误的是（ ）。",[436,438,440,442],{"key":20,"text":437,"correct":22},"甲类仓库只能为单层建筑",{"key":24,"text":439,"correct":29},"乙类厂房的耐火等级为二级时，层数最多为5层",{"key":27,"text":441,"correct":22},"建筑面积为400m2的单层丙类厂房，其耐火等级可为三级",{"key":31,"text":443,"correct":22},"丁类厂房的耐火等级为三级时，层数最多为3层",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":27,"analysis":33},935366,"公安消防部门对某企业的钢结构厂房进行防火检查，其中对钢结构防火涂料检查时，下列做法中，错误的是（ ）。",[448,450,452,454],{"key":20,"text":449,"correct":22},"目测涂层颜色及漏涂和裂缝情况，用1kg榔头轻击涂层检测其强度",{"key":24,"text":451,"correct":22},"用1m直尺检测涂层平整度",{"key":27,"text":453,"correct":29},"用黑色平绒布轻擦薄涂型钢结构防火涂层表面3次，平绒布不变色",{"key":31,"text":455,"correct":22},"现场选取5个不同的涂层部位，用测厚仪分别测量其厚度",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":31,"analysis":33},935367,"某建筑地上 13 层,一级耐火等级, 地上一至二层为商业服务网点，地上三层至十八层为住宅。该建筑屋面采用带有女儿墙的平屋面，室外设计地面的标高为-0.30m ，平屋面和女儿墙的标高分别为 54.6m 和55.8m，首层室内地面的标高为 0.6m。下列关于该建筑的说法中正确的是（ ）。",[460,462,464,466],{"key":20,"text":461,"correct":22},"该建筑的高度应为一类高层住宅建筑",{"key":24,"text":463,"correct":22},"该建筑居住部分与商业服务网点之间应采用耐火极限不低于 2.50h 且无门、窗、洞口的防火隔墙和2.00h 的不燃性楼板完全分隔",{"key":27,"text":465,"correct":22},"商业服务网点中每个分隔单元之间应采用耐火极限不低于 2.50h 且无门、窗、洞口的防火隔墙相互分隔",{"key":31,"text":467,"correct":29},"该商业服务网点每个分隔单元内的任一点至最近直通室外的出口的直线距离不应大于 22m",{"id":469,"libraryId":5,"type":60,"typeLabel":61,"stem":470,"options":471,"answer":482,"analysis":33},935368,"下列关于建筑物内建筑构件的耐火极限的说法，符合规范要求的是（ ）。",[472,474,476,478,480],{"key":20,"text":473,"correct":29},"二级耐火等级的办公建筑，其吊顶采用不燃材料，耐火极限0．10h",{"key":24,"text":475,"correct":29},"三级耐火等级的儿童游乐厅，其吊顶采用难燃材料，耐火极限0．25h",{"key":27,"text":477,"correct":22},"二级耐火等级建筑的门厅的吊顶，采用难燃材料，耐火极限0．25h",{"key":31,"text":479,"correct":22},"三级耐火等级建筑的走道的吊顶，采用难燃材料，耐火极限0．25h",{"key":73,"text":481,"correct":29},"三级耐火等级的中学教学楼，其吊顶采用不燃材料，耐火极限0．25h","ABE",{"id":484,"libraryId":5,"type":60,"typeLabel":61,"stem":485,"options":486,"answer":497,"analysis":33},935369,"下列建筑的耐火等级不应低于二级的有（ ）。",[487,489,491,493,495],{"key":20,"text":488,"correct":29},"使用或储存特殊贵重的机器、仪器等设备或物品的建筑",{"key":24,"text":490,"correct":29},"甲、乙类厂房，使用或产生丙类液体的厂房和有火花、赤热表面、明火的丁类厂房",{"key":27,"text":492,"correct":29},"多层乙类仓库和储存可燃液体的多层丙类仓库",{"key":31,"text":494,"correct":22},"蒸发量为3t／h的燃煤锅炉房",{"key":73,"text":496,"correct":22},"粮食平房仓","ABC",{"id":499,"libraryId":5,"type":60,"typeLabel":61,"stem":500,"options":501,"answer":305,"analysis":33},935370,"建筑耐火等级指建筑物整体的耐火性能，是由组成建筑物的墙、柱、梁、楼板等主要构件的（ ）决定，分为一、二、三、四级。",[502,504,506,508,510],{"key":20,"text":503,"correct":29},"燃烧性能",{"key":24,"text":505,"correct":22},"材料材质",{"key":27,"text":507,"correct":22},"阻燃性能",{"key":31,"text":509,"correct":29},"最低耐火极限",{"key":73,"text":511,"correct":22},"阻燃级别",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":24,"analysis":33},935371,"局部凸出屋顶的瞭望塔、冷却塔、水箱间、微波天线间或设施、电梯机房、排风和排烟机房以及楼梯出口小间等辅助用房占屋面面积不大于（）时，不需计入建筑高度。",[516,518,520,522],{"key":20,"text":517,"correct":22},"1／3",{"key":24,"text":519,"correct":29},"1／4",{"key":27,"text":521,"correct":22},"1／5",{"key":31,"text":523,"correct":22},"2／5",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":31,"analysis":33},935372,"丁、戊类厂房内的油漆工段，当采用封闭喷漆工艺，封闭喷漆空间内保持负压、油漆工段设置可燃气体探测报警系统或自动抑爆系统，且油漆工段占其所在防火分区面积的比例不大于（）时，按火灾危险性较小的部分确定。",[528,530,532,534],{"key":20,"text":529,"correct":22},"5％",{"key":24,"text":531,"correct":22},"10％",{"key":27,"text":533,"correct":22},"15％",{"key":31,"text":535,"correct":29},"20％",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":31,"analysis":33},935373,"仓库的火灾危险性应根据储存物品的火灾危险性及储存量等因素确定，对储存场所进行防火检查时，应检查储存物品的火灾危险类别、数量和存放方式。某仓库的下列做法中，不符合现行国家消防技术标准要求的是（）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"同一座仓库同时存放数种物品时，存储过程中采用分区存储",{"key":24,"text":543,"correct":22},"同一座仓库同时存放了汽油、机械零件、包装用的木箱，将该仓库划分为甲类储存物品仓库",{"key":27,"text":545,"correct":22},"储存电子元件的仓库，采用纸盒与泡沫塑料包裹电子元件，包装材料的体积大于电子元件的体积的1／2，仓库的火灾危险陛划分为丙类",{"key":31,"text":547,"correct":29},"采用木箱包装的戊类物品，木箱重量大于物品本身重量的1／4，将仓库的火灾危险性划分为丁类",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":31,"analysis":33},935374,"某商业中心为坡屋面，室外设计地面标高为-0．2m，建筑首层室内地面标高为±0．00m，室外设计地面至坡屋面檐口和屋脊的高度分别为24．6m、25．4m，该公共建筑的高度为（ ）m。",[552,554,556,558],{"key":20,"text":553,"correct":22},"24．8",{"key":24,"text":555,"correct":22},"25．4",{"key":27,"text":557,"correct":22},"25．2",{"key":31,"text":126,"correct":29},{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":31,"analysis":33},935375,"某住宅建筑，室外设计地面至平屋面的高度为53．6m，室外设计地面标高为-0．2m，建筑首层室内地面标高为±0．00m，首层设置高度为1．5m的储藏室，该住宅建筑的高度为（ ）m。",[563,565,567,569],{"key":20,"text":564,"correct":22},"53．8",{"key":24,"text":566,"correct":22},"53．4",{"key":27,"text":568,"correct":22},"52．1",{"key":31,"text":570,"correct":29},"51．9",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":20,"analysis":33},935376,"某办公建筑，室外设计地面标高为-0．2m，建筑首层室内地面标高为±0．00m，平屋面的标高为24．6m，首层设置了高度为1．5m的储藏室，该公共建筑的高度为（ ）m。",[575,576,578,580],{"key":20,"text":553,"correct":29},{"key":24,"text":577,"correct":22},"24．6",{"key":27,"text":579,"correct":22},"23．3",{"key":31,"text":581,"correct":22},"23．1",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":20,"analysis":33},935377,"某公共建筑物甲、乙、丙，如下图所示，地坪是台阶式，位于不同高程地坪上的甲、乙和丙之间有防火墙分隔，各自有符合规范规定的安全出口，而且可以沿建筑的两个长边设置贯通式或尽头式消防车道时，甲高23m，乙高25m，丙高27m，下列关于建筑分类中，错误的是（）。",[586,588,590,592],{"key":20,"text":587,"correct":29},"建筑物甲属于高层建筑物",{"key":24,"text":589,"correct":22},"建筑物乙属于高层建筑物",{"key":27,"text":591,"correct":22},"建筑物丙属于高层建筑物",{"key":31,"text":593,"correct":22},"建筑物乙和丙属于高层建筑物",{"id":595,"libraryId":5,"type":60,"typeLabel":61,"stem":596,"options":597,"answer":275,"analysis":33},935378,"对某电解食盐厂进行防火检查，检查结果如下，其中不符合规范要求的是（ ）。",[598,600,602,604,606],{"key":20,"text":599,"correct":29},"该厂房的承重结构采用砖混结构",{"key":24,"text":601,"correct":22},"该厂房的总控制室独立设置",{"key":27,"text":603,"correct":29},"厂房内与楼梯间连通部位设置有门斗，门采用乙级防火门与楼梯间的门错位",{"key":31,"text":605,"correct":29},"采用热风循环供暖，循环使用前经净化处理，使空气中的含尘浓度低于其爆炸下限的25％",{"key":73,"text":607,"correct":29},"防火分区之间，采用耐火极限为4．00h的防火卷帘",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":27,"analysis":33},935379,"某综合办公大楼，建筑屋面一部分为坡屋面，其余部分为平屋面。坡屋面部分从综合办公大楼的地面至檐口与屋脊的平均高度为24．5m，平屋面从综合办公大楼地面至屋面面层的高度为22．5m。按照国家消防工程技术标准规定，该综合办公大楼的建筑高度为（）m。",[612,614,616,618],{"key":20,"text":613,"correct":22},"22．5",{"key":24,"text":615,"correct":22},"23．5",{"key":27,"text":617,"correct":29},"24．5",{"key":31,"text":130,"correct":22},{"id":620,"libraryId":5,"type":15,"typeLabel":16,"stem":621,"options":622,"answer":20,"analysis":33},935380,"一级耐火等级的单层、多层厂房（仓库），当采用自动喷水灭火系统能有效保护采用无防火保护的金属结构构件的全部部位时，其屋顶承重构件的耐火极限可不低于（）h。",[623,625,627,629],{"key":20,"text":624,"correct":29},"1．00",{"key":24,"text":626,"correct":22},"1．50",{"key":27,"text":628,"correct":22},"2．00",{"key":31,"text":630,"correct":22},"3．00",{"id":632,"libraryId":5,"type":15,"typeLabel":16,"stem":633,"options":634,"answer":31,"analysis":33},935381,"某办公建筑，标准层建筑面积为1000㎡，室外设计地面标高为-0．2m，建筑首层室内地面标高为1．5m，屋面面层的标高为24．6m，顶层设有高度为1．6m，面积为260㎡的排烟机房，该公共建筑的高度为（ ）m。",[635,636,638,640],{"key":20,"text":553,"correct":22},{"key":24,"text":637,"correct":22},"27．7",{"key":27,"text":639,"correct":22},"26．1",{"key":31,"text":641,"correct":29},"26．4",{"id":643,"libraryId":5,"type":15,"typeLabel":16,"stem":644,"options":645,"answer":20,"analysis":33},935382,"某仓库内存放润滑油1000L，乙醇汽油50L，水泥2吨，该仓库的火灾危险性属于（ ）。",[646,647,648,649],{"key":20,"text":186,"correct":29},{"key":24,"text":188,"correct":22},{"key":27,"text":190,"correct":22},{"key":31,"text":650,"correct":22},"戊类",[652,655,658,661,664,667],{"id":15,"name":653,"category":7,"favorite":654},"领导干部任职前廉政法规知识测试题",92,{"id":656,"name":657,"category":7,"favorite":15},595,"建筑结构与设备",{"id":659,"name":660,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":662,"name":663,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":665,"name":666,"category":7,"favorite":8},534,"BIM工程师",{"id":668,"name":666,"category":7,"favorite":8},535]