[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":652},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,11,50,2974,[13,34,46,58,76,91,103,115,127,139,151,163,175,187,199,214,226,238,250,264,276,288,302,317,329,343,355,367,379,391,406,418,432,446,458,470,482,494,509,521,535,550,562,574,586,598,610,618,630,640],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},935177,1,"单选题","(2016年真题) 消防设施检测机构对某厂房进行验收前的消防设施检测，检查了火灾探测器的类别、型号、适用场所、安装高度等。发现的下列情况中，不符合现行国家消防技术标准要求的是（??）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","类别为B的点型感温火灾控测器安装高度为6m",false,{"key":24,"text":25,"correct":22},"B","类别为A2的点型感温火灾控测器安装高度为7m",{"key":27,"text":28,"correct":29},"C","类别为C的点型感温火灾控测器安装高度为5m",true,{"key":31,"text":32,"correct":22},"D","类别为A1的点型感温火灾控测器安装高度为8m","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},935178,"(2016年真题)自动喷水灭火系统定期巡视检查测试时，下列关于湿式报警阀组检测试验的内容及要求的说法中错误的是（??）",[38,40,42,44],{"key":20,"text":39,"correct":29},"测试过程中系统排出的水应通过排水设施全部排走，湿式报警阀处的排水立管不宜小于DN75",{"key":24,"text":41,"correct":22},"开启末端试水装置，以1.2L\u002FS的流量放水，水流指示器，湿式报警阀，压力开关动作",{"key":27,"text":43,"correct":22},"消防联动控制器应准确接收并显示水流指示器，压力开关，水泵的反馈信号",{"key":31,"text":45,"correct":22},"压力开关应直接连锁启动消防水泵",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},935179,"(2016年真题)某建筑内安装的火灾自动报警系统进行检查时，发现部分模块的连接导线余量不够。根据现行国家消防技术标准，关于模块的连接导线余量的说法中，正确的是，应留有不小于（??）mm的余量",[50,52,54,56],{"key":20,"text":51,"correct":22},"100",{"key":24,"text":53,"correct":29},"150",{"key":27,"text":55,"correct":22},"200",{"key":31,"text":57,"correct":22},"250",{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":75,"analysis":33},935180,2,"多选题","（2020年真题）对某办公楼设置的火灾自动报警系统检测的下列结果中，符合现行《火灾自动报警系统施工及验收标准》（GB 50166）的有（ ）。",[64,66,68,70,72],{"key":20,"text":65,"correct":29},"采用减光率为10dB的减光片遮挡中庭线型光束感烟火灾探测器的火灾报警控制器在3s时发出火灾报警信号",{"key":24,"text":67,"correct":29},"在计算机房设置的管路采样式吸气烟感火灾探测器的采样管最未端加入试验烟后110s，火灾报警控制器发出火灾报警信号",{"key":27,"text":69,"correct":22},"按下走廊侧墙上的一只手动火灾报警按钮后30s，火灾报警控制器发出报警信号",{"key":31,"text":71,"correct":22},"采用发烟装置向会议室的一只感烟火灾探测器吹烟，该探测器的火警确点亮后30s，火灾报警控制器发出报警信号",{"key":73,"text":74,"correct":29},"E","采用发热装置加热配电柜内设置的测温式电气火灾监控探测器至其报警温度:探测器的报警确认灯在20s点亮并保持","ABE",{"id":77,"libraryId":5,"type":60,"typeLabel":61,"stem":78,"options":79,"answer":90,"analysis":33},935181,"（2020年真题）某4层商场，每层划分为1个防火分区、3个防烟分区。对该商场消防设施下列检测结果中，符合现行国家标准要求的有（ ）。",[80,82,84,86,88],{"key":20,"text":81,"correct":29},"按下消防联动控制器上的三层某排烟口的开启按钮，相应的排烟口开",{"key":24,"text":83,"correct":22},"按下四层的一只手动火灾报警按钮，四层的加压送风口打开，加压送风",{"key":27,"text":85,"correct":22},"使三层同一防烟分区内的两只独立的感烟火灾探测器发出火灾报警，三层的所有排烟口打开，相应排烟风机启动",{"key":31,"text":87,"correct":22},"使四层同一防烟分区内的一只感烟火灾探测器和一只手动火灾报警器火灾报警信号，相应的防烟分区内的电动挡烟垂壁下降",{"key":73,"text":89,"correct":29},"关闭排烟风机进口总管上的280℃排烟防火阀，相应的排烟风机停止","AE",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":31,"analysis":33},935183,"（2020年真题）某消防技术服务机构对某商业综合体中庭周围的防火卷帘进行了检测。下列检测结果中,不符合现行国家标准要求的是（ ）",[95,97,99,101],{"key":20,"text":96,"correct":22},"防火卷帘与楼板、梁、柱之间的空隙采用防火封堵材料封堵",{"key":24,"text":98,"correct":22},"启动防火卷帘下降按钮后,测得防火卷帝的下降速度为4m\u002Fmin",{"key":27,"text":100,"correct":22},"中庭顶部满足逻辑关系的两只独立的火灾探测器动作后自动下降至全闭",{"key":31,"text":102,"correct":29},"防火卷帘的温控释放装置动作后,防火卷帘自动下降至距地面1.8m处",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":20,"analysis":33},935184,"（2020年真题）对某建筑内设置的火灾自动报警进行维护管理的下列做法中,不符合现行国家标准《火灾自动报警系统施工及验收标准》（GB50166）的是（ ）",[107,109,111,113],{"key":20,"text":108,"correct":29},"每年对全部消防泵的手动控制功能进行一次检查",{"key":24,"text":110,"correct":22},"每半年年对所安装的全部探测器和手动报警装置报警功能进行一次检查",{"key":27,"text":112,"correct":22},"每月对全部电动防火门、防火卷帘联动控制功能进行一次检查",{"key":31,"text":114,"correct":22},"每季度对所安装的全部消火栓按钮报警功能",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":31,"analysis":33},935185,"（2020年真题）对某商场设置的自动消防设施进行检测时，操作人员将消防联动控制器设于自动控制状态，下列检测结果中，不符合现行国家标准《火灾自动报警系统施工与验收标准》（GB 50166）的是（ ）。",[119,121,123,125],{"key":20,"text":120,"correct":22},"使同一房间分区内两支独立的感烟火灾报警探测器报警空调系统的电动防火阀关闭",{"key":24,"text":122,"correct":22},"使某报警区內只感烟火灾探测器和一只手动火灾报警按钮,发出火灾报警信号,该报警区内的所有常开防火门关闭",{"key":27,"text":124,"correct":22},"使一只感烟火灾探测器发出火灾报警信号,并实施是自动喷水灭火系统报警阀组的压力开关动作相应喷淋泵启动。",{"key":31,"text":126,"correct":29},"按下一只手动火灾报警按钮,同时按下一支消火栓按钮,相应消火栓启动。",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":24,"analysis":33},935186,"（2020年真题）某消防技术服务机构对某大型综合商场内设置的火灾自动报警系统进行检测。下列检测方法和结果中,不符合现行国家标准《火灾自动报警系统施工及验收标准》（GB50166）的是（ ）。",[131,133,135,137],{"key":20,"text":132,"correct":22},"采用减光率为0.9dB的减光片遮挡线型光束感烟火灾探测的探测光路,火灾报警控制器未报警",{"key":24,"text":134,"correct":29},"采用加热装置对可恢复式缆式型感温探测器的一个点加热至其温度达到探测器报警阀值,火灾报警控制器在5s时发出火灾报警信号",{"key":27,"text":136,"correct":22},"对点型可燃气体探测器施加浓度为探测器报警设定值的可燃气体标准样气，探测器的报警确认灯在20s时点亮",{"key":31,"text":138,"correct":22},"釆用剩余电流发生器对剩余电流式电气火灾监控探测器施加其报警设定剩余电流,探测器的报警确认灯在20s时点亮",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":27,"analysis":33},935187,"（2020年真题）某单位对某多层办公楼设置的区域火灾报警系统进行检查。下列检查结果中，不符合现行国家标准《火灾自动报警系统设计规范》（GB50116）的是（ ）.",[143,145,147,149],{"key":20,"text":144,"correct":22},"系统未设置消防联动控制器",{"key":24,"text":146,"correct":22},"系统未设置消防控制室图形显示装置",{"key":27,"text":148,"correct":29},"系统未设置手动火灾报警按钮",{"key":31,"text":150,"correct":22},"系统未设置楼层显示器",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":33},935189,"(2017年真题) 各地在智慧消防建设过程中，积极推广应用 城市消防远程监控系统，根据现行国家标准《 城市消防远程监控系统技术规范》(GB 50440-2007)，下列系统和装置中， 属于城市消防远程监控系统构成部分是（??）。",[155,157,159,161],{"key":20,"text":156,"correct":29},"用户信息传输装置",{"key":24,"text":158,"correct":22},"火灾警报装置",{"key":27,"text":160,"correct":22},"火灾探测报警系统",{"key":31,"text":162,"correct":22},"消防联动控制系统",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":20,"analysis":33},935190,"(2018年真题)根据现行囯家标准《城市消防远程监控系统技术规范》(GB50440)，关于城市消防远程监控系统设计的说法，正确的是（）",[167,169,171,173],{"key":20,"text":168,"correct":29},"城市消防远程监控中心应能同时接收和不少于3个联网用户的火灾报警信息",{"key":24,"text":170,"correct":22},"监控中心向城市消防通信指挥中心转发经确认的火灾报警信息的时间不应大于5s",{"key":27,"text":172,"correct":22},"城市消防远程监控中心的火灾报警信息、建筑消防设施运行状态信息等记录应备份，其保存周期不应小于6个月",{"key":31,"text":174,"correct":22},"城市消防远程监控中心录音文件的保存周期不应少于3个月",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":31,"analysis":33},935191,"(2017年真题)进行区域火灾风险评估时，在明确火灾风险评估目的和内容的基础上，应进行信息采集，重点收集与区域安全相关的信息。下列信息中，不属于区域火灾风险评估时应采集的信息是（??）。",[179,181,183,185],{"key":20,"text":180,"correct":22},"区域内人口概况",{"key":24,"text":182,"correct":22},"消防安全规章制度",{"key":27,"text":184,"correct":22},"区域内经济概况",{"key":31,"text":186,"correct":29},"区域的环保概况",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":27,"analysis":33},935192,"(2018年真题)对某区域进行区域火灾风险评估时，应遵照系统性、实用性、可操作性原则进行评估。下列区域火灾风险评估的做法中，错误的是( )",[191,193,195,197],{"key":20,"text":192,"correct":22},"把评估范围确定为整个区域范围内的社会因素、建筑群和交通路网等",{"key":24,"text":194,"correct":22},"在信息采集时采集评估区域内的人口情况、经济情况和交通情况等",{"key":27,"text":196,"correct":29},"建立评估指标体系时将区域基础信息、火灾危险源作为二级指标",{"key":31,"text":198,"correct":22},"在进行风险识别时把火灾风险分为客观因素和人为因素两类",{"id":200,"libraryId":5,"type":60,"typeLabel":61,"stem":201,"options":202,"answer":213,"analysis":33},935193,"(2018年真题)进行区域消防安全评估时应对区域消防力量进行分析评估。对区域消防力量评估的主要内容有( )",[203,205,207,209,211],{"key":20,"text":204,"correct":29},"消防通信指挥调度能力",{"key":24,"text":206,"correct":22},"消防教育水平",{"key":27,"text":208,"correct":22},"火灾预警能力",{"key":31,"text":210,"correct":29},"消防装备配置水平",{"key":73,"text":212,"correct":29},"消防站数量","ADE",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},935194,"(2017年真题) 对建筑进行火灾风险评估时，应确定评估对象可能面临的火灾风险，关于火灾风险识别的说法中，错误的是（??）",[218,220,222,224],{"key":20,"text":219,"correct":22},"查找火灾风险来源的过程称为火灾风险识别",{"key":24,"text":221,"correct":22},"火灾风险识别是开展火灾风险评估工作所必需的基础环节",{"key":27,"text":223,"correct":22},"消防安全措施有效性分析包括专业队伍扑救能力",{"key":31,"text":225,"correct":29},"衡量火灾风险的高低主要考虑起火概率大小",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},935195,"(2018年真题) 大型体育中心，设有多个竞赛场馆和健身、商业、娱乐、办公等设施。中心进行火灾风险评估时，消防安全措施有效性分析属于（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"信息采集",{"key":24,"text":233,"correct":29},"风险识别",{"key":27,"text":235,"correct":22},"评估指标体系建立",{"key":31,"text":237,"correct":22},"风险分析与计算",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},935196,"(2018年真题)某3层大酒楼，营业面积8000㎡，可容纳2000人同时用餐，厨房用管道天然气作为热源。大酒楼制定了灭火和应急疏散预案，预案中关于处置燃气泄漏的程序和措施，第一步应是()",[242,244,246,248],{"key":20,"text":243,"correct":22},"打燃气公司电话报警",{"key":24,"text":245,"correct":22},"打119电话报警",{"key":27,"text":247,"correct":22},"立即关闭电源",{"key":31,"text":249,"correct":29},"立即关阀断气",{"id":251,"libraryId":5,"type":60,"typeLabel":61,"stem":252,"options":253,"answer":213,"analysis":33},935198,"(2016年真题)某丙类厂房建筑高度为45m，对齐消防救援窗口进行防火检查。下列消防救援窗口设置的做法中，符合规范要求的是（??）。",[254,256,258,260,262],{"key":20,"text":255,"correct":29},"消防救援窗口采用易碎安全玻璃，并在外侧设置明显标志",{"key":24,"text":257,"correct":22},"每个防火分区设置1个消防救援窗口",{"key":27,"text":259,"correct":22},"消防救援窗口设置在3层以上楼层",{"key":31,"text":261,"correct":29},"消防救援窗口的净高和净宽均为1.20m",{"key":73,"text":263,"correct":29},"消防救援窗口的下沿距地面室内高度为1.2m",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":27,"analysis":33},935199,"(2017年真题)外墙保温材料的传热方式( )",[268,270,272,274],{"key":20,"text":269,"correct":22},"绝热",{"key":24,"text":271,"correct":22},"热对流",{"key":27,"text":273,"correct":29},"热传导",{"key":31,"text":275,"correct":22},"热辐射",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":27,"analysis":33},935200,"（2020年真题）某商业综合体外墙设置了可供消防人员进入的窗口，下列对救援窗口的检查结果中，不符合现行国家标准要求的是（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":22},"每层均设置了救援窗口",{"key":24,"text":283,"correct":22},"救援窗口的净高和净宽均为1.0米",{"key":27,"text":285,"correct":29},"每个防火分区设置一个救援窗口",{"key":31,"text":287,"correct":22},"救援窗口的下沿距室内地面高度1.0m",{"id":289,"libraryId":5,"type":60,"typeLabel":61,"stem":290,"options":291,"answer":213,"analysis":33},935201,"（2019年真题）某大剧院设有自动喷水灭火系统和火灾自动报警系统，根据《人员密集场所消防安全评估导则》(GAT1369)，对于该剧院进行消防安全评估，下列检查结果中可直接判定，评估结论等级为差的有（）",[292,294,296,298,300],{"key":20,"text":293,"correct":29},"未确定消防安全评估管理人",{"key":24,"text":295,"correct":22},"在地下一层的一个储物间存放了演出用的大量服装和布景道具",{"key":27,"text":297,"correct":22},"有2具应急照明灯损坏",{"key":31,"text":299,"correct":29},"地下二层的楼梯间前室堆放了大量杂物",{"key":73,"text":301,"correct":29},"自动喷水灭火系统的消防水泵损坏",{"id":303,"libraryId":5,"type":60,"typeLabel":61,"stem":304,"options":305,"answer":316,"analysis":33},935202,"(2018年真题) 某城市天然气调配站建有 4 个储气罐，消防检查发现存在火灾隐患。根据现行国家标准《重大火灾隐患判定方法》（GB 35181），下列检查结果中，可以综合判定为重大火灾隐患的综合判定要素有（ ）。",[306,308,310,312,314],{"key":20,"text":307,"correct":22},"推车式干粉灭火器压力表指针位于黄区",{"key":24,"text":309,"correct":22},"有一个天然气储罐未设置固定喷水冷却装置",{"key":27,"text":311,"correct":29},"室外消火栓阀门关闭不严漏水",{"key":31,"text":313,"correct":29},"消防车道被堵塞",{"key":73,"text":315,"correct":29},"有一个天然气储罐已设置的固定喷水冷却装置不能正常使用","CDE",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":20,"analysis":33},935203,"(2018年真题)某星级宾馆属于消防安全重点单位，关于该星级宾馆消防安全重点部位的确定的说法，错误的是( )。",[321,323,325,327],{"key":20,"text":322,"correct":29},"应将空调机房确定为消防安全重点部位",{"key":24,"text":324,"correct":22},"应将厨房、发电机房确定为消防安全重点部位",{"key":27,"text":326,"correct":22},"应将夜总会确定为消防安全重点部位",{"key":31,"text":328,"correct":22},"应将变配电室、消防控制室确定为消防安全重点部位",{"id":330,"libraryId":5,"type":60,"typeLabel":61,"stem":331,"options":332,"answer":75,"analysis":33},935204,"(2015年真题) 根据《重大火灾隐患判定方法》（GB35181-2017），下列可直接判定为重大火灾隐患的有（）。",[333,335,337,339,341],{"key":20,"text":334,"correct":29},"甲类生产场所设在半地下室",{"key":24,"text":336,"correct":29},"某旅馆，地上5层，总建筑面积3600㎡，未设置自动喷水灭火系统",{"key":27,"text":338,"correct":22},"占地面积15000㎡的小商品市场，沿宽度为6m的消防车道上搭建长80m.宽3m彩钢夹芯板临时仓库",{"key":31,"text":340,"correct":22},"某公共娱乐场所位于多层建筑的第四层，设置封闭楼梯间",{"key":73,"text":342,"correct":29},"易燃易爆化学危险品仓库未设置在相对独立的安全地带",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":27,"analysis":33},935205,"(2017年真题) 关于消防安全管理人及其职责的说法，错误的是()。",[347,349,351,353],{"key":20,"text":348,"correct":22},"消防安全管理人应是单位中负有一定领导职责和权限的人员",{"key":24,"text":350,"correct":22},"消防安全管理人应负责拟定年度消防工作计划，组织制定消防安全制度",{"key":27,"text":352,"correct":29},"消防安全管理人应每日测试主要消防设施功能并及时排除故障",{"key":31,"text":354,"correct":22},"消防安全管理人应组织实施防火检查和火灾隐患整改工作",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":27,"analysis":33},935206,"（2019年真题）根据《机关、团体、企业、事业单位消防安全管理规定》(公安部令第61号)。某大型超市将仓库确定为消防安全重点部位，设置明显的防火标志，实行严格管理，该超市制定的下列管理规定中，属于加强严格管理措施的是（）。",[359,361,363,365],{"key":20,"text":360,"correct":22},"仓库内禁止吸烟和使用明火",{"key":24,"text":362,"correct":22},"不应使用碘钨灯和超过60W以上的白炽灯等高温照明灯具",{"key":27,"text":364,"correct":29},"应用电气火灾监测、物联网技术等技术消防措施",{"key":31,"text":366,"correct":22},"仓库内不得使用电热水器、电视机、电冰箱",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":27,"analysis":33},935207,"（2019年真题）根据《消防法》《公安部关于实验机关、团体、企业、事业单位消防安全管理规定有关问题的通知》(公通字(2001)97号)。下列单位中，应当界定为消防安全重点单位的是（）。",[371,373,375,377],{"key":20,"text":372,"correct":22},"建筑面积为190㎡的卡拉0K厅",{"key":24,"text":374,"correct":22},"住宿床位为40张的养老院",{"key":27,"text":376,"correct":29},"高层公共建筑的公寓楼",{"key":31,"text":378,"correct":22},"生产车间员工为150人的建筑钢磨具加工企业",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":33},935208,"（2019年真题）某商品批发中心建筑面积为3000㎡,地上3层、地下1层,经营服装、日用品、家具。根据一现行国家标准《重大火灾隐患判定方法》(8518),对该中心进行防火检查时发现的下列火灾隐患中,可以直接判定为重大火灾隐患的是（）",[383,385,387,389],{"key":20,"text":384,"correct":29},"日用品经营区销售15kg瓶装液化石油气",{"key":24,"text":386,"correct":22},"有商家在安全疏散通道上摆摊位,占用疏散通道",{"key":27,"text":388,"correct":22},"火灾自动报警系统有25个探测器显示故障",{"key":31,"text":390,"correct":22},"室内消火栓被广告牌遮挡",{"id":392,"libraryId":5,"type":60,"typeLabel":61,"stem":393,"options":394,"answer":405,"analysis":33},935209,"（2019年真题）对人员密集场所进行防火检查，根据现行国家标准《重大火灾隐患判定方法》(GB35181)，下列检查时发现的隐患中，可以作为重大火灾隐患综合判定要素的有（）",[395,397,399,401,403],{"key":20,"text":396,"correct":22},"防烟楼梯间的防火门损坏率为设置总数的15%",{"key":24,"text":398,"correct":29},"消防控制室值班操作人员未取得相应资格证",{"key":27,"text":400,"correct":29},"防烟、排烟设施不能正常运行",{"key":31,"text":402,"correct":29},"歌舞厅墙面采用聚氨酯材料装修",{"key":73,"text":404,"correct":29},"楼梯间设置栅栏","BCDE",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},935210,"(2017年真题) 单位在确定消防重点部位以后，应加强对消防重点部位的管理。下列管理措施中，不属于消防重点部位管理措施的是（??）",[410,412,414,416],{"key":20,"text":411,"correct":29},"隐患管理",{"key":24,"text":413,"correct":22},"制度管理",{"key":27,"text":415,"correct":22},"立牌管理",{"key":31,"text":417,"correct":22},"教育管理",{"id":419,"libraryId":5,"type":60,"typeLabel":61,"stem":420,"options":421,"answer":431,"analysis":33},935211,"(2017年真题) 对某城市综合体进行防火检查， 发现存在火灾隐患。 根据重大火灾隐患综合判定规则，下列火灾隐患中。 存在2条即可判定为重大火灾隐患的是（??）",[422,423,425,427,429],{"key":20,"text":301,"correct":22},{"key":24,"text":424,"correct":29},"设在四层的卡拉OK厅未按规定设置排烟措施",{"key":27,"text":426,"correct":22},"地下一层超市防火卷帘门不能正常落下",{"key":31,"text":428,"correct":29},"疏散走道的装修材料采用胶合板",{"key":73,"text":430,"correct":22},"消防用电设备末端不能自动切换","BD",{"id":433,"libraryId":5,"type":60,"typeLabel":61,"stem":434,"options":435,"answer":316,"analysis":33},935212,"(2016年真题)针对人员密集场所，在下列隐患情况，根据《重大火灾除患判定方法》的规定，可判定重大隐患要素的有（??）",[436,438,440,442,444],{"key":20,"text":437,"correct":22},"一个防火分区设置的6樘防火门有2樘损坏",{"key":24,"text":439,"correct":22},"商场营业厅内的疏散距离超过规定距离的20%",{"key":27,"text":441,"correct":29},"火灾自动报警系统处于故障设备，不能恢复正常运行",{"key":31,"text":443,"correct":29},"设置的防排烟系统不能正常使用",{"key":73,"text":445,"correct":29},"安全出口被封堵",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":20,"analysis":33},935213,"(2017年真题)某大型商场制定了消防应急预案，内容包括初期火灾处置程序和措施。下列处置程序和措施中，错误的是（??）。",[450,452,454,456],{"key":20,"text":451,"correct":29},"发现火灾时，起火部位现场员工应当于3min内形成灭火第一战斗力量",{"key":24,"text":453,"correct":22},"发现起火时，应立即打119电话报警",{"key":27,"text":455,"correct":22},"发现起火时，安全出口或通道附近的员工应在第一时间负责引导人员进行疏散",{"key":31,"text":457,"correct":22},"发现火灾时，消火栓附近的员工应立即利用消火栓灭火",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":27,"analysis":33},935214,"(2017年真题)消防安全重点单位 “ 三项 ” 报告备案制度中， 不包括（??）",[462,464,466,468],{"key":20,"text":463,"correct":22},"消防安全管理人员报告备案",{"key":24,"text":465,"correct":22},"消防设施维护保养报告备案",{"key":27,"text":467,"correct":29},"消防规章制度报告备案",{"key":31,"text":469,"correct":22},"消防安全自我评估报告备案",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":31,"analysis":33},935215,"(2017年真题)某公司拟在一体育馆举办大型周年庆典活动，根据相关要求成立了活动领导小组，并安排公司的一名副经理担任疏散引导组的组长。根据相关规定，疏散引导组职责中不包括（??）。",[474,476,478,480],{"key":20,"text":475,"correct":22},"熟悉体育馆所在安全通道、 出口的位置",{"key":24,"text":477,"correct":22},"在每个安全出口设置工作人员、 确保通道、 出口畅通",{"key":27,"text":479,"correct":22},"安排人员在发生火灾时第一时间引导参加活动的人员从最近的安全出口疏散",{"key":31,"text":481,"correct":29},"进行灭火和应急疏散预案的演练",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":20,"analysis":33},935217,"(2018年真题)某28层大厦，建筑面积5000㎡，分别由百货公司、宴会酒楼、温泉酒店使用，三家单位均符合消防安全重点单位界定标准，应当由()向当地消防部门申报消防安全重点单位备案。",[486,488,490,492],{"key":20,"text":487,"correct":29},"各单位分别",{"key":24,"text":489,"correct":22},"大厦物业管理单位",{"key":27,"text":491,"correct":22},"三家单位联合",{"key":31,"text":493,"correct":22},"大厦消防设施维保单位",{"id":495,"libraryId":5,"type":60,"typeLabel":61,"stem":496,"options":497,"answer":508,"analysis":33},935218,"(2018年真题)某箱包加工生产企业，厂房建筑5层，建筑面积5000㎡，员工600人，企业组织开展半年度灭火和应急疏散演练。根据《机关，团体、企业、事业单位消防安全管理规定》(公安部今第61号)，演练结束后，应当记录存档的内容有( )。",[498,500,502,504,506],{"key":20,"text":499,"correct":22},"演练方案概要、发现的问题与原因",{"key":24,"text":501,"correct":22},"经验教训以及改进工作建议",{"key":27,"text":503,"correct":22},"当地消防队情况",{"key":31,"text":505,"correct":29},"演练的内容、时间和地点",{"key":73,"text":507,"correct":29},"参加演练单位和人员","DE",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},935219,"(2016年真题) 《机关，团体，企业，事业单位消防安全管理规定》（公安部令第61号）规定，消防安全重点单位应当进行每日防火巡查，并确定巡查的内容和频次，公众聚集场所在营业期间的防火巡查，应当至少每（??）小时一次。",[513,515,517,519],{"key":20,"text":514,"correct":29},"2",{"key":24,"text":516,"correct":22},"1",{"key":27,"text":518,"correct":22},"3",{"key":31,"text":520,"correct":22},"4",{"id":522,"libraryId":5,"type":60,"typeLabel":61,"stem":523,"options":524,"answer":405,"analysis":33},935220,"（2020年真题）某宾馆，地上12层，地下3层，建筑高度为40m，每层建筑面积为3500m2。根据现行国家标准《重大火灾隐患判定方法》（GB 35181），检查发现的下列问题中，不属于重大火灾隐患判定要素中直接判定项的有（ ）。",[525,527,529,531,533],{"key":20,"text":526,"correct":22},"未设置火灾自动报警系统",{"key":24,"text":528,"correct":29},"地上二层未划分防火分区",{"key":27,"text":530,"correct":29},"消防车登高操作场地被占用",{"key":31,"text":532,"correct":29},"消防电梯无法正常运行",{"key":73,"text":534,"correct":29},"自动喷水灭火系统无法正常运行",{"id":536,"libraryId":5,"type":60,"typeLabel":61,"stem":537,"options":538,"answer":549,"analysis":33},935221,"（2020年真题）某历史博物馆有1幢博物馆楼和1幢木结构历史保护建筑。根据《机关、团体、企业、事业单位消防安全管理规定》（公安部令第61号），该博物馆的下列部位中，应确定为消防安全重点部位的有（ ）。",[539,541,543,545,547],{"key":20,"text":540,"correct":29},"消防水泵房",{"key":24,"text":542,"correct":29},"文物藏品库",{"key":27,"text":544,"correct":29},"消防控制室",{"key":31,"text":546,"correct":29},"总配电室",{"key":73,"text":548,"correct":22},"馆长办公室","ABCD",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":31,"analysis":33},935222,"（2020年真题）大厦属于高危单位,由物业服务单位对公用的疏散走道建筑消防设施和消防车道实施统一管理。根据《国务院办公厅关于印发消防安全责任制实施办法的通知》（国办发（2017）87号），该物业服务单位除履行消防安全重点单位的职责外，还需要履行的消防安全职责是（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":22},"建立消防档案",{"key":24,"text":557,"correct":22},"确定消防安全重点部位",{"key":27,"text":559,"correct":22},"确定消防安全管理人",{"key":31,"text":561,"correct":29},"定期组织消防安全评估",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":27,"analysis":33},935223,"(2017年真题) 根据《社会消防安全教育培训规定》公安部令109号，关于单位消防安全培训的主要内容和形式的说法，错误的是（??）",[566,568,570,572],{"key":20,"text":567,"correct":22},"各单位应对新上岗和进入新岗位的职工进行上岗前消防安全培训",{"key":24,"text":569,"correct":22},"各单位应对在岗的职工每年至少进行一次消防安全培训",{"key":27,"text":571,"correct":29},"各单位至少每年组织一次灭火、应急疏散演练",{"key":31,"text":573,"correct":22},"各单位职工应具备消除火灾隐患的能力、扑救初起火灾的能力、组织人员疏散逃生的能力",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":31,"analysis":33},935224,"(2016年真题)人员密集场所应当定期开展全员消防教育培训，提高全员的消防安全意识和消防安全能力，下列能力中，不属于员工通过教育培训必须具备的消防安全能力的是（??）。",[578,580,582,584],{"key":20,"text":579,"correct":22},"检查和消防火灾隐患的能力",{"key":24,"text":581,"correct":22},"扑救初期火灾的能力",{"key":27,"text":583,"correct":22},"组织人员疏散逃生的能力",{"key":31,"text":585,"correct":29},"救援被困人员的能力",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":24,"analysis":33},935225,"(2015年真题) 下列消防安全宣传教育培训，不属于社会单位组织开展的是（）。",[590,592,594,596],{"key":20,"text":591,"correct":22},"对新上岗的员工进行上岗前消防安全培训",{"key":24,"text":593,"correct":29},"在火灾多发季节.农业收获季节和重大节假日，组织开展有针对性的消防宣传教育",{"key":27,"text":595,"correct":22},"对在岗的员工每年至少进行一次消防安全培训，并通过多种形式开展经常性的消防安全宣传教育",{"key":31,"text":597,"correct":22},"对公众聚集场所员工每半年至少进行一次消防安全培训",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":24,"analysis":33},935226,"(2016年真题) 某建筑工程施工现场按照现行国家消防技术标准的规定，配置临时消防设施，临时消防应急照明灯具选用自备电源的应急照明灯具时，自备电源的连续供电时间不应小于（）min。",[602,604,606,608],{"key":20,"text":603,"correct":22},"30",{"key":24,"text":605,"correct":29},"60",{"key":27,"text":607,"correct":22},"40",{"key":31,"text":609,"correct":22},"50",{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":20,"analysis":33},935227,"(2017年真题) 某大型商场制定了消防应急预案，内容包括初期火灾处置程序和措施。下列处置程序和措施中，错误的是()。",[614,615,616,617],{"key":20,"text":451,"correct":29},{"key":24,"text":453,"correct":22},{"key":27,"text":455,"correct":22},{"key":31,"text":457,"correct":22},{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":20,"analysis":33},935228,"(2017年真题) 在建工程施工过程中，施工现场的消防安全负责人应定期组织消防安全管理人员对施工现场的消防安全进行检查。施工现场定期防火检查内容不包括()。",[622,624,626,628],{"key":20,"text":623,"correct":29},"防火巡查是否记录",{"key":24,"text":625,"correct":22},"动火作业的防火措施是否落实",{"key":27,"text":627,"correct":22},"临时消防设施是否有效",{"key":31,"text":629,"correct":22},"临时消防车道是否畅通",{"id":631,"libraryId":5,"type":15,"typeLabel":16,"stem":632,"options":633,"answer":31,"analysis":33},935230,"(2017年真题) 某公司拟在一体育馆举办大型周年庆典活动，根据相关要求成立了活动领导小组，并安排公司的一名副经理担任疏散引导组的组长。根据相关规定，疏散引导组职责中不包括()。",[634,636,638,639],{"key":20,"text":635,"correct":22},"熟悉体育馆所在安全通道、出口的位置",{"key":24,"text":637,"correct":22},"在每个安全出口设置工作人员、确保通道、出口畅通",{"key":27,"text":479,"correct":22},{"key":31,"text":481,"correct":29},{"id":641,"libraryId":5,"type":15,"typeLabel":16,"stem":642,"options":643,"answer":27,"analysis":33},935231,"(2016年真题) 根据《建设工程施工现场消防安全技术规范》GB50720，施工单位应编制现场灭火及应急疏散预案。下列内容中，不属于灭火及应急疏散预案主要内容的是（）。",[644,646,648,650],{"key":20,"text":645,"correct":22},"应急疏散及救援的程序和措施",{"key":24,"text":647,"correct":22},"应急灭火处置机构及各级人员应急处置职责",{"key":27,"text":649,"correct":29},"动火作业的防火措施",{"key":31,"text":651,"correct":22},"报警，接警处置的程序和通讯联络的方式",[653,656,659,662,665,668],{"id":15,"name":654,"category":7,"favorite":655},"领导干部任职前廉政法规知识测试题",92,{"id":657,"name":658,"category":7,"favorite":15},595,"建筑结构与设备",{"id":660,"name":661,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":663,"name":664,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":666,"name":667,"category":7,"favorite":8},534,"BIM工程师",{"id":669,"name":667,"category":7,"favorite":8},535]