[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-937512":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},937512,605,2,"多选题","水泵接合器的安装要求正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","水泵接合器接口距室外消火栓或消防水池的距离宜为10~40m",false,{"key":16,"text":17,"correct":18},"B","设计无要求时,墙壁水泵接合器安装高度距地面宜为0.7m",true,{"key":20,"text":21,"correct":18},"C","墙壁水泵接合器与墙面上的门、窗、孔、洞的净距离不应小于2.0m，且不应安装在玻璃幕墙下方",{"key":23,"text":24,"correct":18},"D","地下水泵接合器的安装，应使进水口与井盖底面的距离不大于0.4m，且不应小于井盖的半径",{"key":26,"text":27,"correct":18},"E","水泵接合器与给水系统之间不应设置除检修阀门以外其他的阀门","BCDE","2020新教材P161 本题考查的是水泵接合器的安装。A错，水泵接合器接口的位置应方便操作，安装在便于消防车接近的人行道或非机动车行驶地段，距室外消火栓或消防水池的距离宜为15~40m。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]