[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-937279":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},937279,605,2,"多选题","消防应急标志灯具安装在地面上时，下列设置正确的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","灯具的所有金属构件应采用耐腐蚀构件或做防腐处理",true,{"key":16,"text":17,"correct":14},"B","电源连接和控制线连接应采用密封胶密封",{"key":19,"text":20,"correct":14},"C","标志灯应安装在疏散走道、通道的中心位置",{"key":22,"text":23,"correct":24},"D","标志灯具表面与地面高度差不宜大于5mm",false,{"key":26,"text":27,"correct":14},"E","标志灯表面应与地面平行","ABCE","2020新教材P386 标志灯的所有金属构件应采用耐腐蚀构件或做防腐处理，标志灯配电、通信线路的连接应采用密封胶密封；AB正确。 标志灯应安装在疏散走道、通道的中心位置，C正确； 标志灯表面应与地面平行，高于地面距离不应大于3mm，D错误，E正确。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]