[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-937222":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},937222,605,2,"多选题","节日彩灯的检查应符合（ ）的规定。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","建筑物顶部彩灯采用有防雨性能的专用灯具，灯罩要拧紧",true,{"key":16,"text":17,"correct":18},"B","彩灯连接线路应采用绝缘铜导线，导线截面面积应满足载流量要求，且不应小于5mm2",false,{"key":20,"text":21,"correct":14},"C","悬挂式彩灯应采用防水吊线灯头，灯头线与干线的连接应牢固并绝缘包扎紧密",{"key":23,"text":24,"correct":18},"D","彩灯供电线路应采用橡胶多股铜芯软导线，截面面积不应小于5.0mm2，垂直敷设时，对地面的距离不小于4.0m",{"key":26,"text":27,"correct":14},"E","彩灯的电源除统一控制外，每个支路应有单独控制开关和熔断器保护，导线的支持物应安装牢固","ACE","2020新教材P376 节日彩灯的检查应符合下列规定:（1）建筑物顶部彩灯采用有防雨性能的专用灯具，灯罩要拧紧。（2）彩灯连接线路应采用绝缘铜导线，导线截面面积应满足载流量要求，且不应小于2.5mm2，灯头线截面面积不应小于1.0mm2。（3）悬挂式彩灯应采用防水吊线灯头，灯头线与干线的连接应牢固、绝缘包扎紧密。（4）彩灯供电线路应采用橡胶多股铜芯软导线，截面面积不应小于4.0mm2，垂直敷设时，对地面的距离不小于3.0m。（5）彩灯的电源除统一控制外，每个支路应有单独控制开关和熔断器保护，导线的支持物应安装牢固。 A、C、E正确，选项B的灯头线不应小于1.Omm2，故B错误：选项D的彩灯供电线路应采用橡胶多股铜芯软导线，截面积不应小于4.Omm2，故D错误。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]