[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-937069":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},937069,605,2,"多选题","灭火器配置场所的危险等级为中危险级的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","二类高层建筑的写字楼、公寓楼",true,{"key":16,"text":17,"correct":14},"B","百货楼、超市",{"key":19,"text":20,"correct":14},"C","民用燃气锅炉房",{"key":22,"text":23,"correct":24},"D","汽车加油站、加气站",false,{"key":26,"text":27,"correct":14},"E","地下汽车库","ABCE","GB 50140-2005 灭火器配置设计规范 附录C和附录D，选项A、B、C、E，二类高层建筑的写字楼、公寓楼，百货楼、超市，民用燃气锅炉房和地下汽车库危险等级为中危险级：选项D，汽车加油站、加气站的危险等级为严重危险级。故D错误。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]