[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-937019":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},937019,605,1,"单选题","自动喷水灭火系统设置场所的危险等级应根据建筑规模、高度以及火灾危险性、火灾荷载和保护对象的特点等确定。下列建筑中，自动喷水灭火系统设置场所的火灾危险等级为中危险级Ⅰ级的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","建筑高度为50m的办公楼",true,{"key":16,"text":17,"correct":18},"B","建筑高度为23m的四星级旅馆",false,{"key":20,"text":21,"correct":18},"C","2000个座位剧场的舞台",{"key":23,"text":24,"correct":18},"D","总建筑面积5600m2的商场","参考《自动喷水灭火设计规范》附录A：选项A，高层办公楼危险等级为中危险Ⅰ级，故A正确；选项B，建筑高度为24m及以下的旅馆为轻危险级，故B错误；选硕C。舞台为中危险Ⅱ级，故C错误；选项D，总建筑面积5000㎡及以上的商场为中危险Ⅱ级，故D错误。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]