[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-937015":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},937015,605,1,"单选题","下列（ ）自动喷水灭火系统的设置场所可不设置火灾报警系统。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","设置湿式系统的场所",true,{"key":16,"text":17,"correct":18},"B","设置预作用系统的场所",false,{"key":20,"text":21,"correct":18},"C","设置雨淋系统的场所",{"key":23,"text":24,"correct":18},"D","设置自动控制水幕系统的场所","选项A，湿式系统由闭式喷头动作喷水引起水流指示器动作联动报警，湿式报警阀打开、压力开关动作连锁启动喷淋泵供水灭火，可不设置火灾报警系统。故A正确；选项B，预作用系统由火灾报警系统联动开启雨淋阀组，故应设火灾报警系统。故B错误；选项C，规范推荐的雨淋系统由电气联动，即由火灾报警系统联动，故应设置火灾报警系统。故C错误；选项D，自动控制水幕系统由电气联动开启雨淋阀喷水灭火，故应设置火灾报警系统；人工操作的设置通用阀门即可。因此本选项应设置火灾报警系统。故D错误。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]