[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936975":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},936975,605,1,"单选题","某建筑高度为50m的宾馆，采用一路市政电源供电，柴油发电设备作为备用电源，建筑内的排烟风机采用主备电源自动切换装置。下列关于主备电源自动切换装置的设置中，不合理的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","自动切换装置设置在变电站内",true,{"key":16,"text":17,"correct":18},"B","自动切换装置设置在排烟风机房的风机控制配电箱内",false,{"key":20,"text":21,"correct":18},"C","主备电源自动切换时间为20s",{"key":23,"text":24,"correct":18},"D","主备电源自动切换时间为25s","选项A、B，参考《建筑设计防火规范》10.1.8：“消防控制室、消防水泵房、防烟和排烟风机房的消防用电设备及消防电梯等的供电，应在其配电线路的最末一级配电箱处设置自动切换装置”，故A错误，B正确：选项C、D，参考《建筑设计防火规范》10.1.4：“消防用电按一、二级负荷供电的建筑，当采用自备发电设备作备用电源时，自备发电设备应设置自动和手动启动装置。当采用自动启动方式时，应能保证在30s内供电”，故C、D正确。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]