[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936963":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},936963,605,1,"单选题","下列关于干粉灭火系统组成及其设置要求的说法中，不正确的是。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","储存装置的驱动气体应选用惰性气体，宜选用氮气",false,{"key":16,"text":17,"correct":18},"B","储存装置可设在耐火等级为三级的房间内",true,{"key":20,"text":21,"correct":14},"C","干粉储存容积设计压力可取1.6MPa或2.5MPa压力级",{"key":23,"text":24,"correct":14},"D","驱动压力不得大于干粉储存容器的最高工作压力。","选项A、D，参《干粉灭火设计规范》5.1.2：“驱动气体应选用惰性气体，宜选用氮气；二氧化碳含水率不应大于0.015%（m\u002Fm），其他气体含水率不得大于0.006%（m\u002Fm）；驱动压力不得大于干粉储存容器的最高工作压力”，故A、D说法正确：选项B，参《干粉灭火设计规范》5.1.4：“储存装置宜设在专用的储存装置间内。专用储存装置间的设置应符合下列规定：储存装置耐火等级不应低于二级”，故B错误；选项C，参《干粉灭火设计规范》5.1.1-2：“干粉储存容器设计压力可取1.6MPa或2.5MPa压力级”，故C正确。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]