[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936903":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},936903,605,1,"单选题","自喷系统喷头安装时操作错误的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","安装在易受机械损伤处的喷头，应加设喷头防护罩",false,{"key":16,"text":17,"correct":14},"B","喷头安装应使用专用扳手，严禁利用喷头的框架施拧；喷头的框架、溅水盘产生变形或释放原件损伤时，应采用规格、型号相同的喷头更换",{"key":19,"text":20,"correct":14},"C","喷头安装时，不得对喷头进行拆装、改动，并严禁给喷头附加任何装饰性涂层",{"key":22,"text":23,"correct":24},"D","喷头安装后应对自喷系统进行试压和冲洗",true,"选项A，参考《自动喷水灭火系统施工及验收规范》5.2.4：安装在易受机槭损伤处的喷头，应加设喷头防护罩。故A正确；选项B，参考《自动喷水灭火系统施工及验收规范》5.2.3：“喷头安装应使用扳手，严禁利用喷头的框架施拧；喷头的框架、溅水盘产生变形或释放原件损伤时，应采用规格、型号相同的喷头更换。故B正确；选项C，参考《自动喷水灭火系统施工及验收规范》5.2.2：喷头安装时，不得对喷头进行拆装、改动，并严禁给喷头附加任何装饰性涂层。故C正确；选项D，参考《自动喷水灭火系统施工及验收规范》5.2.1：喷头安装应在系统试压、冲洗合格后进行。故D错误。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]