[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936893":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},936893,605,1,"单选题","有关系统设备检测数量要求正确的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","实际安装数量在10台以下者，全部检验",false,{"key":16,"text":17,"correct":14},"B","实际安装数量在6—10台者，抽验3台",{"key":19,"text":20,"correct":14},"C","实际安装数量超过10台者，按比例进行抽检，抽验总数不应少于3台",{"key":22,"text":23,"correct":24},"D","实际安装数量超过10台者，按实际安装数量30%~50%的比例抽验， 但抽验总数不应少于5台",true,"本题考查的是系统设备检测数量要求。消防联动控制系统中其他各种用电设备、区域显示器应按下列要求进行功能检验：①实际安装数量在5台以下者：全部检验；②实际安装数量在6-10台者，抽验5台；③实际安装数量超过10台者，按实际安装数30%~50%的比例抽验、但抽验总数不应少于5台。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]