[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936858":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},936858,605,1,"单选题","下列关于自动喷水灭火系统的说法中，错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","雨淋系统与预作用系统均采用开式洒水喷头",true,{"key":16,"text":17,"correct":18},"B","干式系统和预作用系统的配水管道应设置快速排气阀",false,{"key":20,"text":21,"correct":18},"C","雨淋系统应能由配套的火灾自动报警系统或传动管控制并启动雨淋报警阀",{"key":23,"text":24,"correct":18},"D","预作用系统应由火灾自动报警系统自动开启雨淋报警阀，并转换为湿式系统","选项A，参考《喷规》6.1.4：“干式系统、预作用系统采用直立型喷头或干式下垂型喷头”，故A 错误，预作用系统不应采用开式洒水喷头；选项B。参考《喷规》4.2.9-4：“干式系统和预作用系统的配水管道应设快速排气阀。有压充气管道的快速排气阀入口前应设电动阀”，故B正确；选项C，参考《喷规》2.1.3：“雨淋系统：由火灾自动报警系统或传动管控制，自动开启雨淋报警阀和启动供水泵后，向开式洒水喷头供水的自动灭火系统。亦称开式系统”，故C正确；选项D，参考《喷规》11.0.1：“预作用系统、雨淋系统及自动控制的水幕系统，应在火灾报警系统报警后，立即自动向配水管道供水”，故D正确。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]