[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936843":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},936843,605,1,"单选题","下列关于水喷雾灭火系统水雾喷头选型和设置要求的说法中，错误的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","扑灭电器火灾所选用离心雾化型水雾喷头",false,{"key":16,"text":17,"correct":14},"B","室内散发粉尘的场所设置的水雾喷头配带防尘帽",{"key":19,"text":20,"correct":14},"C","保护可燃气体储罐时，水雾喷头距离保护储罐外壁不应大于0.7m",{"key":22,"text":23,"correct":24},"D","保护油浸式变压器时，水雾喷头之间的水平距离与垂直距离不应大于1.2m",true,"选项A、B，参考《水喷雾规》4.0.2：“水雾喷头的选型应符合下列要求：1扑救电气火灾，应选用离心雾化型水雾喷头；2室内粉尘场所设置的水雾喷头应带防尘帽，室外设置的水雾喷头宜带防尘帽；3离心雾化型水雾喷头应带柱状过滤网”，故A、B正确；选项C，参考《水喷雾规》312.6：“当保护对象为甲、乙、丙类液体和可燃气体储罐时，水雾喷头与保护储罐外壁之间的距离不应大于0.7m”，故C正确：选项D，参考《水喷雾规》3.2.5：“当保护对象为油浸式电力变压器时，水雾喷头的布置应符合下列要求：1.变压器绝缘子升高座孔口、油枕、散热器、集油坑应设水雾喷头保护；2.水雾喷头之间的水平距离与垂直距离应满足水雾锥相交的要求”，无1.2m的要求，故D错误；",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]