[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936841":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},936841,605,1,"单选题","下列关于水流指示器描述中不正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","水流指示器的作用是将水流信号转换成电信号，及时报告发生火灾的部位",false,{"key":16,"text":17,"correct":18},"B","每个防火分区和每个楼层均应设水流指示器",true,{"key":20,"text":21,"correct":14},"C","仓库内顶板下喷头与货架内喷头应分别设置",{"key":23,"text":24,"correct":14},"D","当水流指示器入口前设置控制阀时，应采用信号阀","选项A.水流指示器的作用是将水流信号转换成电信号，及时报告发生火灾的部位，故A正确。选项B，除报警阀组控制的喷头只保护不超过防火分区面积的同层场所外，每个防火分区和每个楼层均应设水流指示器，少了前提条件，故B错误。选项C，仓库内顶板下喷头与货架内喷头应分别设置，故C正确。选项D，当水流指示器入口前设置控制带时，应采用信号阀，故D正确。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]