[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936828":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},936828,605,1,"单选题","下列关于气体灭火的叙述中，（ ）是错误的。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","对一些大防护区、大设计用量的系统来说，采用两套或三套管网设计是有优势的",false,{"key":16,"text":17,"correct":18},"B","同一防护区，当设计两套管网时，集流管、启动瓶可分别设置",true,{"key":20,"text":21,"correct":14},"C","管网上不应采用四通管件进行分流",{"key":23,"text":24,"correct":14},"D","管网可以采用三通管件进行分流","选项A，参考《气体灭火规范》3.1.10：“同一防护区，当设计两套或三套管网时，集流管可分别设置，系统启动装置必须共用。各管网上喷头流量均应按同一灭火设计浓度、同一喷放时间进行设计”，条文说明：“对一些大防护区、大设计用量的系统来说，采用两套或三套管网设计，可减小管网管径，有利管道设备选用和安全”，可知，A正确：选项B，参考《气体灭火规范》3.1.10，强调“系统启动装置必须共用”，故B错误；选项C，参考《气体灭火规范》3.1.11可知，C正确；选项D，三通是均衡管网常用管件，D正确。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]