[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936726":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},936726,605,2,"多选题","过滤器是细水雾灭火系统的关键部件之一，安装过滤器可以防止水中杂质损坏设备和堵塞喷头，由于喷头一般均自带过滤网，因此，首先要在供水水源和供水管网上设置过滤器进行初级过滤。过滤器应符合下列规定。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","在储水箱进水口处应设置过滤器",true,{"key":16,"text":17,"correct":14},"B","出水口或控制阀前应设置过滤器",{"key":19,"text":20,"correct":14},"C","过滤器的网孔孔径不应大于喷头最小喷孔孔径的80%",{"key":22,"text":23,"correct":24},"D","在细水雾灭火系统中常用的过滤器是盘式过滤器",false,{"key":26,"text":27,"correct":14},"E","过滤器的材质应为不锈钢、铜合金，或其他耐腐蚀性能不低于不锈钢、铜合金的材料","ABCE","选项A、B，参考《细水雾规范》3.5.9：“在储水箱进水口处应设置过滤器，出水口或控制阀前应设置过滤器，过滤器的设置位置应便于维护、更换和清洗等”，故A、B正确；3.5.10过滤器应符合下列规定：1过滤器的材质应为不锈铜、铜合金，或其他耐腐蚀性能不低于不锈钢、铜合佥的材料；2过滤器的网孔孔径不应大于喷头最小喷孔孔径的80%。在细水雾灭火系统中常用的过滤器是Y型过滤器”。故C正确、D错误、E正确。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]