[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936648":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},936648,605,1,"单选题","下列关于消防施工现场的设置，不符合规范要求的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","固定动火作业点与在建工程的防火间距为10m",false,{"key":16,"text":17,"correct":14},"B","办公用房成组布置时，每组8栋，则组与组之间的防火间距10m。",{"key":19,"text":20,"correct":14},"C","临时的宿舍建筑层数为2层，每层建筑面积200 m2",{"key":22,"text":23,"correct":24},"D","临时的发电机房建筑层数为2层，每层建筑面积200 m2",true,"A正确，可燃材料堆场及其加工场、固定动火作业场与在建工程的防火间距不应小于10m。B正确，当办公用房、宿舍成组布置时，其防火问距可适当减小，但应符合以下要求：①每组临时用房的栋数不应超过10栋，组与组之间的防火间距不应小于8m。C正确，临时搭建的宿舍、办公用房建筑层数不应超过3层，每层建筑面积不应大于300 m2。D错，除办公、宿舍用房外，施工现场内诸如发电机房、变配电房、厨房操作间、锅炉房、可燃材料和易燃易爆危险品库房，建筑层数应为1层，建筑面积不应大于200 m2。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]