[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936463":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},936463,605,2,"多选题","根据《火灾自动报警系统施工及验收规范》GB 50166—2007的要求，下列关于火灾自动报警系统周期性维护保养的说法中，正确的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","每年检查消防电梯的联动控制功能",true,{"key":16,"text":17,"correct":18},"B","每年检查风机控制柜手动控制功能",false,{"key":20,"text":21,"correct":18},"C","每季度检查火灾警报器的报警功能",{"key":23,"text":24,"correct":18},"D","每月应检查火灾报警控制器的功能",{"key":26,"text":27,"correct":14},"E","每年对消防应急广播功能试验","AE","根据《火灾自动报警系统施工及验收规范》GB 50166—2019 每年检查消防电梯的联动控制功能，A选项正确；每月，季检查风机控制柜手动控制功能，B选项不正确；每年度检查火灾警报器的报警功能，C选项不正确；每年应检查火灾报警控制器的功能，D选项错误；每年对消防应急广播功能试验，E选项正确。本题答案为AE。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]