[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936430":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},936430,605,2,"多选题","根据国家标准《建筑消防设施的维护管理》GB 25201，对火灾自动报警系统消防联动控制器的检测内容，主要包括（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","控制器显示功能",true,{"key":16,"text":17,"correct":14},"B","备用电源充、放电功能",{"key":19,"text":20,"correct":21},"C","自检功能",false,{"key":23,"text":24,"correct":14},"D","消防联动控制器手、自动联动控制功能",{"key":26,"text":27,"correct":14},"E","主、备电切换功能","ABDE","根据《建筑消防设施的维护管理》GB 25201—2010附录D，消防联动控制器的检测内容包括：消防联动控制器及控制模块手、自动联动控制功能，主、备电切换功能，控制器显示功能，备用电源充、放电功能。本题答案为ABDE。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]