[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936428":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},936428,605,2,"多选题","对火灾自动报警系统实施检测维护，每年度应开展一次检查和试验的项目有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","火灾报警控制器报警功能",true,{"key":16,"text":17,"correct":14},"B","防火门监控器故障报警功能",{"key":19,"text":20,"correct":21},"C","风机控制柜手动控制功能",false,{"key":23,"text":24,"correct":14},"D","非消防电源联动控制功能",{"key":26,"text":27,"correct":14},"E","火灾显示盘报警显示功能","ABDE","根据《火灾自动报警系统施工及验收规范》GB 50166—2019 每年应检查和试验火灾自动报警系统下列功能： 1）火灾报警控制器报警功能。 2）防火门监控器故障报警功能。 3）非消防电源联动控制功能。 4）火灾显示盘报警显示功能。 每月，季对风机控制柜进行一次手动控制功能检查。 本题答案为ABDE。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]