[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936273":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},936273,605,1,"单选题","下列关于灭火器进场检查的说法，错误的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","灭火器的铭牌、生产日期和维修日期等标志应齐全",false,{"key":16,"text":17,"correct":14},"B","灭火器筒体应无明显缺陷和机械损伤",{"key":19,"text":20,"correct":21},"C","灭火器压力指示器的指针应在黄区范围内",true,{"key":23,"text":24,"correct":14},"D","灭火器的保险装置应完好","根据《建筑灭火器配置验收及检查规范》GB 50444—20082．2．1，灭火器的进场检查应符合下列要求： 1）灭火器应符合市场准入的规定，并应有出厂合格证和相关证书。 2）灭火器的铭牌、生产日期和维修日期等标志应齐全。 3）灭火器的类型、规格、灭火级别和数量应符合配置设计要求。 4）灭火器筒体应无明显缺陷和机械损伤。 5）灭火器的保险装置应完好。 6）灭火器压力指示器的指针应在绿区范围内。 7）推车式灭火器的行驶机构应完好。 本题答案为C。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]