[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936153":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},936153,605,1,"单选题","某施工单位承接了一项泡沫灭火系统的安装工程，下列关于泡沫灭火系统管网安装及冲洗、试压的说法中，错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","水平管道安装时要注意留有管道坡度，在防火堤内要以3‰的坡度坡向防火堤",false,{"key":16,"text":17,"correct":18},"B","管道穿过防火堤时要需要安装套管，套管的长度应大于防火堤厚度50mm",true,{"key":20,"text":21,"correct":14},"C","立管要用管卡固定在支架上，管卡间距不能大于3m",{"key":23,"text":24,"correct":14},"D","半固定式系统的泡沫管道，在防火堤外设置的高背压泡沫产生器快装接口要水平安装","管道穿过防火堤、防火墙、楼板时，需要安装套管。穿防火堤和防火墙套管的长度不能小于防火堤和防火墙的厚度;穿楼板套管的长度要高出楼板50mm ，底部要与楼板底面相平。管道与套管间的空隙需要采用防火材料封堵;管道穿过建筑物的变形缝时，要采取保护措施。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]