[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936141":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},936141,605,1,"单选题","某电信大楼中的计算机主机房、通讯设备间内设置了组合分配式七氟丙烷气体灭火系统。下列关于该系统设计的说法中，错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","同一集流管上的储存容器，其规格、充压压力和充装量应相同",false,{"key":16,"text":17,"correct":18},"B","同一防护区，当设计两套及以上管网时，系统启动装置可以分别设置，但集流管必须共用",true,{"key":20,"text":21,"correct":14},"C","管网上不应采用四通管件进行分流",{"key":23,"text":24,"correct":14},"D","喷头宜贴近防护区顶面安装，距顶面的最大距离不宜大于0.5m","根据《气体灭火系统设计规范》GB 50370—2005中3．1．9，同一集流管上的储存容器，其规格、充压压力和充装量应相同，A选项正确；根据3．1．10，同一防护区，当设计两套或三套管网时，集流管可分别设置，系统启动装置必须共用。各管网上喷头流量均应按同一灭火设计浓度、同一喷放时间进行设计，B选项错误；根据3．1．11，管网上不应采用四通管件进行分流，C选项正确；根据3．1．13，喷头宜贴近防护区顶面安装，距顸面的最大距离不宜大于0．5 m。D选项正确。本题答案为B。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]