[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936061":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},936061,605,1,"单选题","某消防技术服务机构应某企业要求，对企业所在大楼安装自动喷水灭火系统。下列有关报警阀组的安装顺序，描述正确的是（）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","先安装水源控制阀、报警阀，然后进行报警阀辅助管道的连接，水源控制阀、报警阀与配水干管的连接",true,{"key":16,"text":17,"correct":18},"B","先进行报警阀辅助管道的连接，水源控制阀、报警阀与配水干管的连接，然后安装水源控制阀、报警阀",false,{"key":20,"text":21,"correct":18},"C","先安装水源控制阀，然后进行报警阀辅助管道的连接，再安装报警阀，最后进行水源控制阀、报警阀与配水干管的连接",{"key":23,"text":24,"correct":18},"D","先进行水源控制阀、报警阀与配水干管的连接，再安装水源控制阀、报警阀，最后再进行报警阀辅助管道的连接","报警阀组安装前应对供水管网试压、冲洗合格。安装顺序应先安装水源控制阀、报警阀，然后进行报警阀辅助管道的连接，水源控制阀、报警阀与配水干管的连接，应使水流方向一致。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]