[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-936043":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},936043,605,2,"多选题","对自动喷水灭火系统实施检查维护，下列项目中，属于每月检查内容的有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","报警阀启动性能测试",true,{"key":16,"text":17,"correct":14},"B","消防水泵接合器完好性检查",{"key":19,"text":20,"correct":14},"C","喷头的完好状况、备用量",{"key":22,"text":23,"correct":24},"D","水源供水能力测试",false,{"key":26,"text":27,"correct":24},"E","报警阀旁的放水试验阀进行测试","ABC","下列项目至少每月进行一次检查与维护: （1）电动、内燃机驱动的消防水泵（稳压泵）启动运行测试。 （2）喷头完好状况、备用量及异物清除等检查。 （3）系统所有阀门状态及其铅封、锁链完好状况检查。 （4）消防气压给水设备的气压、水位测试，消防水池、消防水箱的水位以及消防用水不被挪用的技术措施检查。 （5）水泵接合器完好性检查。 （6）过滤器排渣、完好状况检查。 （7）报警阀启动性能测试。 （8）电磁阀启动试验。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]