[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935999":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},935999,605,2,"多选题","根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017的规定，下列组件需有水流方向的永久性标志的有（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","水流指示器",true,{"key":16,"text":17,"correct":14},"B","水泵接合器",{"key":19,"text":20,"correct":14},"C","止回阀",{"key":22,"text":23,"correct":24},"D","自动排气阀",false,{"key":26,"text":27,"correct":24},"E","压力开关","ABC","根据《自动喷水灭火系统施工及验收规范》GB 50261—20173．2．9，压力开关、水流指示器、自动排气阀、减压阀、泄压阀、多功能水泵控制阀、止回阀、信号阀、水泵接合器及水位、气压、阀门限位等自动监测装置应有清晰的铭牌、安全操作指示标志和产品说明书；水流指示器、水泵接合器、减压阀、止回阀、过滤器、泄压阀、多功能水泵控制阀尚应有水流方向的永久性标志；安装前应进行主要功能检查。本题答案为ABC。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]