[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935969":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},935969,605,2,"多选题","在自动喷水灭火系统设备和组件安装完成后应对系统进行调试。根据《自动喷水灭火系统施工及验收规范》（GB 50261），系统调试主控项目应包括的内容有（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","水源测试",true,{"key":16,"text":17,"correct":14},"B","消防水泵调试",{"key":19,"text":20,"correct":21},"C","排水设施调试",false,{"key":23,"text":24,"correct":21},"D","电动阀调试",{"key":26,"text":27,"correct":14},"E","稳压泵调试","ABE","自动喷水灭火系统调试包括水源测试、消防水泵调试、稳压泵调试、报警阀调试、排水设施调试和联动试验等内容。调试过程中，系统出水通过排水设施全部排走。主控项目不包括排水设施调试，排水设施调试属于一般项目。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]