[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935949":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},935949,605,1,"单选题","下列选项中不会造成湿式报警阀报警管路误报警的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","未按照安装图样安装",false,{"key":16,"text":17,"correct":14},"B","延迟器下部孔板堵塞",{"key":19,"text":20,"correct":14},"C","报警管路未按设计图纸",{"key":22,"text":23,"correct":24},"D","报警管路阀门关闭",true,"报警阀报警管路误报警故障原因分析：1）未按照安装图纸安装或者未按照调试要求进行调试；2）报警阀组渗漏通过报警管路流出；3）延迟器下部孔板溢出水孔堵塞,发生报警或者缩短延迟时间，ABC选项错误；报警管路阀门关闭，报警管路直接不能报警，所以D选项正确。本题答案为D。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]