[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935831":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},935831,605,1,"单选题","下列有关消防供水设施、设备安装要求的说法中，不正确的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","消防水泵在安装前应复核消防水泵之间，以及消防水泵与墙或其他设备之间的间距",false,{"key":16,"text":17,"correct":14},"B","地下式消防水泵接合器的安装，应使进水口与井盖地面的距离不大于0．4m，且不应小于井盖的半径",{"key":19,"text":20,"correct":14},"C","气压水罐宜有有效水容积指示器",{"key":22,"text":23,"correct":24},"D","稳压泵的吸水管上应设置暗杆闸阀",true,"根据《消防给水及消火栓系统技术规范》GB 50974—201412．3．2—4，消防水泵安装前应复核消防水泵之间，以及消防水泵与墙或其他设备之间的间距，并应满足安装、运行和维护管理的要求，A选项正确；根据12．3．6—6，地下消防水泵接合器的安装，应使进水口与井盖底面的距离不大于0．4m，且不应小于井盖的半径，B选项正确；根据12．3．4—3，气压水罐宜有有效水容积指示器，C选项正确；根据5．3．5，稳压泵吸水管应设置明杆闸阀，稳压泵出水管应设置消声止回阀和明杆闸阀，D选项错误。本题答案为D。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]